Search NASA⌕ Search

SEARCH · Search NASA

Results for “source configuration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Applications of radio interferometry to navigation

Radio astronomy experiments have demonstrated the feasibility of making precise position measurements using interferometry techniques. The application of this method to navigation and marine geodesy is discussed, and comparisons are made with existing navigation systems. The very long baseline technique, with a master station, can use either an artificial satellite or natural sources as position references; a high-speed data link is required. A completely ship-borne system is shown to be feasible, at the cost of poorer sensitivity for natural sources. A comparison of Doppler, delay and phase-track modes of operating a very long baseline configuration is made, as that between instantaneous measurements and those where a source can be tracked from horizon to transit. Geometric limitations in latitude and longitude coverage are discussed. The characteristics of natural radio sources, their flux, distribution on the sky, and apparent size are shown to provide a limit on position measurements precision. The atmosphere and frequency standard used both contribute to position measurement uncertainty by affecting interferometric phase.

Knowles, S. H.↗

The Effects of Surfaces on the Aerodynamics and Acoustics of Jet Flows

Aircraft noise mitigation is an ongoing challenge for the aeronautics research community. In response to this challenge, low-noise aircraft concepts have been developed that exhibit situations where the jet exhaust interacts with an airframe surface. Jet flows interacting with nearby surfaces manifest a complex behavior in which acoustic and aerodynamic characteristics are altered. In this paper, the variation of the aerodynamics, acoustic source, and far-field acoustic intensity are examined as a large at plate is positioned relative to the nozzle exit. Steady Reynolds-Averaged Navier-Stokes solutions are examined to study the aerodynamic changes in the field-variables and turbulence statistics. The mixing noise model of Tam and Auriault is used to predict the noise produced by the jet. To validate both the aerodynamic and the noise prediction models, results are compared with Particle Image Velocimetry (PIV) and free-field acoustic data respectively. The variation of the aerodynamic quantities and noise source are examined by comparing predictions from various jet and at plate configurations with an isolated jet. To quantify the propulsion airframe aeroacoustic installation effects on the aerodynamic noise source, a non-dimensional number is formed that contains the flow-conditions and airframe installation parameters.

Smith, Matthew J.↗

Design, Calibration, and Application of A Cryogenic Low-Background Infrared Radiometer for Spectral Irradiance and Radiance Measurements From 4- to 20-μm Wavelength

We have constructed, calibrated, and tested a cryogenic low-background infrared (IR) radiometer for both spectral radiance and irradiance measurements over the 4- to 20-μm wavelength range. The primary purpose of the Missile Defense Transfer Radiometer (MDXR) is to measure absolute irradiance or radiance from cryogenic IR test chamber sources using a photoconductive Si:As blocked-impurity band (BIB) detector and a set of spectral filters. The MDXR also includes an absolute cryogenic radiometer (ACR) and a Fourier-transform spectrometer (FTS). For irradiance measurements, the ACR is used to provide the primary power scale for the BIB detector in conjunction with spectral filters, whereas the FTS/BIB configuration derives its scale from an internal blackbody source. The two measurement scales show agreement for the irradiance of highly collimated (<1 mrad) IR beams from 10 -13 to 10 -8 W / μm / cm 2 within the combined relative uncertainties of 2.6% (coverage factor k = 1.) We have also calibrated the radiometer for radiance measurements using a large cavity fluid bath blackbody that overfills the spatial and angular extent of the radiometer entrance pupil. The radiometric calibration uncertainty analysis of the radiometer and its maintenance and stability are discussed.

radiometry↗

OBSERVATIONS OF A HIGH-MASS PROTOSTAR IN NGC 7538 S

We present high angular resolution continuum observations of the high-mass protostar NGC 7538 S with BIMA and CARMA at 3 and 1.4 mm, Very Large Array (VLA) observations at 1.3, 2, 3.5, and 6 cm, and archive Infrared Array Camera (IRAC) observations from the Spitzer Space Observatory, which detect the star at 4.5, 5.8, and 8 {mu}m. The star looks rather unremarkable in the mid-IR. The excellent positional agreement of the IRAC source with the VLA free-free emission, the OH, CH{sub 3}OH, H{sub 2}O masers, and the dust continuum confirms that this is the most luminous object in the NGC 7538 S core. The continuum emission at millimeter wavelengths is dominated by dust emission from the dense cold cloud core surrounding the protostar. Including all array configurations, the emission is dominated by an elliptical source with a size of {approx}8'' Multiplication-Sign 3''. If we filter out the extended emission we find three compact millimeter sources inside the elliptical core. The strongest one, S{sub A}, coincides with the VLA/IRAC source and resolves into a double source at 1.4 mm, where we have subarcsecond resolution. The measured spectral index, {alpha}, between 3 and 1.4 mm is {approx}2.3, and steeper at longer wavelengths, suggesting a low dust emissivity or that the dust is optically thick. We argue that the dust in these accretion disks is optically thick and estimate a mass of an accretion disk or infalling envelope surrounding S{sub A} to be {approx}60 M{sub Sun }.

79 ASTRONOMY AND ASTROPHYSICS↗

Simultaneous measurement of group refractive index and thickness of optical samples using optical coherence tomography

Optical coherence tomography (OCT), based on a Michelson interferometer and utilizing low coherence light as the optical source, is a novel technique for the noninvasive imaging of optical scattering media. A simple OCT scheme based on a 3x3 fiber coupler is presented for the simultaneous measurement of the refractive index and thickness of optical samples. The proposed system enables the refractive index and thickness to be determined without any prior knowledge of the sample parameters and is characterized by a simple and compact configuration, a straightforward measurement procedure, and a low cost. The feasibility of the proposed approach is demonstrated experimentally using BK7 and B270 optical glass samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Add-a-Source Analysis Method for Neutron Coincidence Counting of Waste: Laboratory Exercises

In this session you will setup the INCC code to perform calibration and verification measurements on simulated waste drums using the Waste Drum Assay System (WDAS) detector, which uses the add-a-source (AAS) method. The basis of the AAS method is to measure the change in the counting rate from a small 252 Cf source (~3x10 4 n/s) located outside of the drum and to use this information to correct the count rate from material inside the drum for any changes caused by the matrix inside the drum. The count rate of the material inside the drum is corrected to the empty drum case so that only a single mass calibration curve has to be measured (for the empty drum configuration). In the WDAS system, the AAS neutron source has one location, centered beneath the waste drum. The sample matrix has two primary effects on the neutrons: (1) energy reduction by scattering reactions and (2) neutron absorption of the low-energy neutrons. In general, the counter is designed with an optimum moderator (CH 2 ) thickness to be relatively insensitive to the energy reduction; however, as the hydrogen density in the drum increases, the adsorption process significantly reduces the measured neutron signal.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Field Demonstration of The Krauklis Seismic Wave In A Novel Mva Method For Geologic CO 2 Storage

The Energy & Environmental Research Center (EERC) conducted a feasibility study of a new, low-impact geophysics monitoring method designed to incrementally track the saturation front of CO 2 injected into a reservoir. The method leverages a new way of transmitting energy from the surface to the reservoir and employs a new subsurface signal called the Krauklis wave (K-wave) and other guided waves for seismic monitoring. The EERC partnered with Seismos, Inc., the company that holds the exclusive technology license for this method, to advance development of K-wave technology, and Denbury Onshore, LLC, to field-test the system. The system was field-tested at Denbury’s Bell Creek oil field, currently undergoing CO 2 -based enhanced oil recovery (EOR) in southeastern Montana. The K-wave system uses a wellhead-mounted source to propagate energy down the wellbore in the form of a tube wave and through the well perforations into the reservoir. Part of the energy transmitted through the perforations into the reservoir converts to slow moving K-waves and/or other guided waves that are expected to propagate through the formation to neighboring wells. The propagated signal would induce tube waves in the neighboring wells that return to the surface to be recorded with a wellhead-mounted receiver. The propagation time of the signal is directly affected by the presence of CO 2 between the wells, so the difference in transit time of the returning signal between pre- and postinjection data sets could be used to help define the lateral extent of a CO 2 saturation front. Objectives of the study were to demonstrate, validate, and evaluate the K-wave method’s ability to monitor the morphology of injected CO 2 and estimate saturation distribution. Results from the demonstration were to be compared to conventional 4-D surface seismic methods, dynamic reservoir simulations, and CO 2 breakthrough data to validate the technology and provide useful information that may result in improvements. Prior to mobilizing for the full-scale K-wave baseline survey, a field test was conducted to better understand wellhead hardware configurations and test the response from the Bell Creek reservoir using three wells. Useful operational information resulted but signal from the first-generation gas release/gas injection source was not recorded in neighboring wells. After the initial field test, numerical modeling of the K-wave method was initiated using parameters specific to the Bell Creek Field. Modeling results indicated that the fundamental concepts behind the K-wave method exhibited problems and revealed a significantly greater attenuation of the signal at the wellbore perforations than expected, totaling on the order of 10-8 from source well to receiver well over a 400-m well spacing. Modeling also showed that greater source frequency bandwidth was needed to produce guided waves within a 30-foot-thick reservoir layer such as that at Bell Creek and that reservoir layer seismic velocity would need to be slower than the velocities of the bounding layers in order to act as a wave guide opposite to what exists at Bell Creek. Modeling results prompted a second field test with a stronger, second-generation displacement source developed in the interim. Concurrent with the second field test, a 3-D seismic survey was acquired to serve as a baseline for project validation and to serve as a monitor data set for the portion of the project area where CO 2 injection had already commenced. The new source was tested using a four-well geometry and failed to produce a detectable signal, which appeared to confirm modeling results and indicated that the Bell Creek Field is not an ideal site for the K-wave test. It was concluded that a source with sufficient strength and bandwidth could not be built to overcome the factors discovered by the modeling within a reasonable amount of time. Several other sites undergoing CO 2 -based EOR were also evaluated; however, none of these sites was amenable because of geology, limitations of source and receiver hardware, or the advanced state of the CO 2 flood. In addition, two other configurations of the source and receiver layout were considered; however, these design modifications either changed the scope of the project or did not meet the goals of the Carbon Storage Program. In consultation with the U.S. Department of Energy (DOE) Project Manager and Technology Manager, a no-go decision was invoked to forego additional expenditures as the technology would not meet current project objectives. Project activities to date have moved the technology forward by developing modeling equations that can be applied elsewhere, advanced the state of wellhead sensors and sources, and spurred improvements to field operations. The 3-D seismic survey in the project area and the dynamic reservoir simulations done as part of this study have provided value for ongoing and future synergistic activities at Bell Creek related to DOE carbon storage goals.

54 ENVIRONMENTAL SCIENCES↗

A catalog of radio sources to be occulted by comets P/Halley and P/Giacobini-Zinner

A catalog of radio sources which lie along the paths of comets P/Halley and P/Giacobini-Zinner is presented to facilitate planning of radio-source occultation experiments. The sources were observed at 20 cm wavelength, using the VLA in the B configuration to provide accurate positions and flux densities for occultation predictions. Since the majority of these sources had not been previously mapped, the catalog and source maps may be of more general use than solely for occultation experiments.

De Pater, I.↗

RF H- Ion Source with Saddle Antenna

In this project we are developing an RF H- surface plasma source (SPS) which will synthesize the most important developments in the field of negative ion sources to provide high pulsed and average current, higher brightness, longer lifetime and higher reliability by improving a power efficiency. Several versions of new plasma generators with different antennas and magnetic field configurations were tested in a small AlN test chamber in the SNS ion source Test Stand. Then a prototype saddle antenna was installed in the Test Stand with a larger, normal-sized SNS AlN chamber that achieved a peak current of 67 mA and an apparent efficiency of 1.6 mA/kW. These values are comparable to those of the present SNS sources and can be expected to be improved when the prototype is developed into an operational version in the next phase of the project.

43 PARTICLE ACCELERATORS↗

Aeroacoustic Study of a Subscale Large Civil Transport (STAR) Model – Part 1: Simulations

Results from a computational aeroacoustic study of the Subsonic Transport Aeroacoustic Research (STAR) model are presented. The model, a 26%-scale semispan Boeing 777-200 aircraft, was an inceptive configuration in a comprehensive simulation campaign to accurately predict the airframe noise of a full-scale, large civil transport during landing. The lengthy process of obtaining a high-fidelity, CFD-ready, vetted, digital representation of the model is described in detail. The simulations were performed with the STAR model installed in the NASA Ames 40- by 80-foot full-scale wind tunnel to enable direct comparisons with aerodynamic and acoustic measurements of the model, presented separately in Part 2 of the study. Two versions of the wind tunnel test section were considered. The entire test section was used to simulate the aerodynamic behavior of the model; an open-wall representation of the section was adopted during the acoustic simulations to eliminate wall reflections. To preserve the aerodynamic equivalency of the model for the two simulated tunnel configurations, the open-wall computations were executed at an angle-of-attack one degree higher than that of the corresponding closed-wall tunnel. The effect on aerodynamic behavior of several minor geometry alterations necessary to con-form the simulated to the tested model was assessed – the modifications considerably altered the strength and extent of a flow separation zone on the inboard segment of the flap. Also evaluated was the impact of spatial resolution on aerodynamic and acoustic characteristics of the model – in general, medium resolution was sufficient to establish convergence trends for averaged surface pressure behavior and proper localization of noise sources. After the aeroacoustic characteristics of the baseline configuration were predicted, a toboggan-shaped fairing designed to reduce main landing gear noise was evaluated computationally. Far-field noise spectra for the baseline and toboggan-equipped STAR model were calculated via a Ffowcs-Williams and Hawkings integral approach, with flow quantities on a permeable data surface enclosing the source regions used as input. Results from the simulations indicated that, while the fairing reduced gear noise in the near-field, it had a negligible effect on the far-field noise signature of the model. This trend agreed with previously published experimental results obtained during sub-scale, isolated gear tests and full-scale flight tests

airframe noise↗

Development of a radio frequency ion source with multi-helicon plasma injectors for neutral beam injection system of Versatile Experiment Spherical Torus

Despite of high plasma density, helicon plasma has not yet been applied to a large area ion source such as a driver for neutral beam injection (NBI) system due to intrinsically poor plasma uniformity in the discharge region. In this study, a radio-frequency (RF) ion source with multi-helicon plasma injectors for high plasma density with good uniformity has been designed and constructed for the NBI system of Versatile Experiment Spherical Torus at Seoul National University. The ion source consists of a rectangular plasma expansion chamber (120 × 120 × 120 mm{sup 3}), four helicon plasma injectors with annular permanent magnets and RF power system. Main feature of the source is downstream plasma confinement in the cusp magnetic field configuration which is generated by arranging polarities of permanent magnets in the helicon plasma injectors. In this paper, detailed design of the multi-helicon plasma injector and plasma characteristics of the ion source are presented.

43 PARTICLE ACCELERATORS↗

Scoping Analysis of Source Term and Functional Containment Attenuation Factors

In order to meet future regulatory requirements, the Next Generation Nuclear Plant (NGNP) Project must fully establish and validate the mechanistic modular high temperature gas-cooled reactor (HTGR) source term. This is not possible at this stage in the project, as significant uncertainties in the final design remain unresolved. In the interim, however, there is a need to establish an approximate characterization of the source term. The NGNP team developed a simplified parametric model to establish mechanistic source term estimates for a set of proposed HTGR configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Piloted Simulation Study of the Effects of High-Lift Aerodynamics on the Takeoff Noise of a Representative High-Speed Civil Transport

As part of an effort between NASA and private industry to reduce airport-community noise for high-speed civil transport (HSCT) concepts, a piloted simulation study was initiated for the purpose of predicting the noise reduction benefits that could result from improved low-speed high-lift aerodynamic performance for a typical HSCT configuration during takeoff and initial climb. Flight profile and engine information from the piloted simulation were coupled with the NASA Langley Aircraft Noise Prediction Program (ANOPP) to estimate jet engine noise and to propagate the resulting source noise to ground observer stations. A baseline aircraft configuration, which also incorporated different levels of projected improvements in low-speed high-lift aerodynamic performance, was simulated to investigate effects of increased lift and lift-to-drag ratio on takeoff noise levels. Simulated takeoff flights were performed with the pilots following a specified procedure in which either a single thrust cutback was performed at selected altitudes ranging from 400 to 2000 ft, or a multiple-cutback procedure was performed where thrust was reduced by a two-step process. Results show that improved low-speed high-lift aerodynamic performance provides at least a 4 to 6 dB reduction in effective perceived noise level at the FAA downrange flyover measurement station for either cutback procedure. However, improved low-speed high-lift aerodynamic performance reduced maximum sideline noise levels only when using the multiple-cutback procedures.

Glaab, Louis J.↗

SOLAR CYCLE VARIATIONS OF CORONAL NULL POINTS: IMPLICATIONS FOR THE MAGNETIC BREAKOUT MODEL OF CORONAL MASS EJECTIONS

In this paper, we investigate the solar cycle variation of coronal null points and magnetic breakout configurations in spherical geometry, using a combination of magnetic flux transport and potential field source surface models. Within the simulations, a total of 2843 coronal null points and breakout configurations are found over two solar cycles. It is found that the number of coronal nulls present at any time varies cyclically throughout the solar cycle, in phase with the flux emergence rate. At cycle maximum, peak values of 15-17 coronal nulls per day are found. No significant variation in the number of nulls is found from the rising to the declining phase. This indicates that the magnetic breakout model is applicable throughout both phases of the solar cycle. In addition, it is shown that when the simulations are used to construct synoptic data sets, such as those produced by Kitt Peak, the number of coronal nulls drops by a factor of 1/6. The vast majority of the coronal nulls are found to lie above the active latitudes and are the result of the complex nature of the underlying active region fields. Only 8% of the coronal nulls are found to be connected to the global dipole. Another interesting feature is that 18% of coronal nulls are found to lie above the equator due to cross-equatorial interactions between bipoles lying in the northern and southern hemispheres. As the majority of coronal nulls form above active latitudes, their average radial extent is found to be in the low corona below 1.25 R {sub sun} (175, 000 km above the photosphere). Through considering the underlying photospheric flux, it is found that 71% of coronal nulls are produced though quadrupolar flux distributions resulting from bipoles in the same hemisphere interacting. When the number of coronal nulls present in each rotation is compared to the number of bipoles emerging, a wide scatter is found. The ratio of coronal nulls to emerging bipoles is found to be approximately 1/3. Overall, the spatio-temporal evolution of coronal nulls is found to follow the typical solar butterfly diagram and is in qualitative agreement with the observed time dependence of coronal mass ejection source-region locations.

79 ASTRONOMY AND ASTROPHYSICS↗

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]↗

Pictures from Year Two CNEC and CVT Measurements

Below are all of the pictures for the CNEC and CVT measurements performed at the DAF in July 2016. In total there are 165 pictures. The photos on pages 2-105 were taken during the first week of measurements and the photos on pages 106-165 were taken during the second week of measurements. Many photos are applicable to both sets, which is why it is best to keep the entire set together. For most configurations, a description of the configuration was written on a white board; photos of the measurement setup were taken, then a photo of the white board was taken. For example, the pictures on pages 6-19 (which precede a white board picture on page 20) are of the configuration with Rocky Flats Shells 1-2 surrounded by 4 AmLi sources, which is listed on the white board picture on page 20. In some cases, the white board picture precedes the configuration pictures.

47 OTHER INSTRUMENTATION↗

Generating code adapted for interlinking legacy scalar code and extended vector code

Mechanisms for intermixing code are provided. Source code is received for compilation using an extended Application Binary Interface (ABI) that extends a legacy ABI and uses a different register configuration than the legacy ABI. First compiled code is generated based on the source code, the first compiled code comprising code for accommodating the difference in register configurations used by the extended ABI and the legacy ABI. The first compiled code and second compiled code are intermixed to generate intermixed code, the second compiled code being compiled code that uses the legacy ABI. The intermixed code comprises at least one call instruction that is one of a call from the first compiled code to the second compiled code or a call from the second compiled code to the first compiled code. The code for accommodating the difference in register configurations is associated with the at least one call instruction.

97 MATHEMATICS AND COMPUTING↗

Uncertainty Budget for Detector-Based Absolute Radiometric Calibration With GLAMR

The accuracy of the absolute radiometric calibration (RadCal) for remote sensing instruments is essential to their wide range of applications. The uncertainty associated to the traditional source-based RadCal method is assessed at a 2% (k=1) or higher level for radiance measurement. To further improve the accuracy to meet the demands of climate studies, a detector-based approach using tunable lasers as a light source has been devised. The Goddard Laser for Absolute Measurement of Radiance, known as the GLAMR system, is a notable example of the incorporation of such technology. Using transfer radiometers calibrated at NIST as calibration standards, the absolute spectral response (ASR) function of a remote sensing instrument is measured with its uncertainty traceable to the International System of Units. This paper presents a comprehensive uncertainty analysis of the detector-based absolute RadCal using the GLAMR system. It identifies and examines uncertainty sources during the GLAMR RadCal test, including those from the GLAMR system, the testing configuration, and data processing methodologies. Analysis is carried out to quantify the contribution of each source and emphasize the most influential factors. It is shown that the calibration uncertainty of GLAMR RadCal can be better than 0.3% (k=1) in the wavelength range of 350-950 nm and 0.6% (k=1) between 950-2300 nm, with the exception of regions with strong water absorption. In addition, recommendations are made to refine the calibration process to further reduce the uncertainty.

Zhipeng Wang↗