Search NASA⌕ Search

SEARCH · Search NASA

Results for “spin diffusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Structural characterization, thermal, spectroscopic and magnetic studies of the (C{sub 3}H{sub 12}N{sub 2}){sub 0.75}[Mn{sub 1.50}{sup II}Fe{sub 1.50}{sup III}(AsO{sub 4})F{sub 6}] and (C{sub 3}H{sub 12}N{sub 2}){sub 0.75}[Co{sub 1.50}{sup II}Fe{sub 1.50}{sup III}(AsO{sub 4})F{sub 6}] compounds

The (C{sub 3}H{sub 12}N{sub 2}){sub 0.94}[Mn{sub 1.50}Fe{sub 1.50}{sup III}(AsO{sub 4})F{sub 6}] and (C{sub 3}H{sub 12}N{sub 2}){sub 0.75}[Co{sub 1.50}Fe{sub 1.50}{sup III}(AsO{sub 4})F{sub 6}] compounds 1 and 2 have been synthesized using mild hydrothermal conditions. These phases are isostructural with (C{sub 3}H{sub 12}N{sub 2}){sub 0.75}[Fe{sub 1.5}{sup II}Fe{sub 1.5}{sup III}(AsO{sub 4})F{sub 6}]. The compounds crystallize in the orthorhombic Imam space group. The unit cell parameters calculated by using the patterns matching routine of the FULPROOF program, starting from the cell parameters of the iron(II),(III) phase, are: a 7.727(1) A, b = 11.047(1) A, c = 13.412(1) A for 1 and a = 7.560(1) A, b 11.012(1) A, c = 13.206(1) A for 2, being Z = 8 in both compounds. The crystal structure consists of a three-dimensional framework constructed from edge-sharing [M{sup II}(1){sub 2}O{sub 2}F{sub 8}] (M = Mn, Co) dimeric octahedra linked to [Fe{sup III}(2)O{sub 2}F{sub 4}] octahedra through the F(1) anions and to the [AsO{sub 4}] tetrahedra by the O(1) vertex. This network gives rise two kinds of chains, which are extended in perpendicular directions. Chain 1 is extended along the a-axis and chain 2 runs along the c-axis. These chains are linked by the F(1) and O(1) atoms and establish cavities delimited by eight or six polyhedra along the [1 0 0] and [0 0 1] directions, respectively. The propanediammonium cations are located inside these cavities. The thermal study indicates that the structures collapse with the calcination of the organic dication at 255 and 285 deg. C for 1 and 2, respectively. The Moessbauer spectra in the paramagnetic state indicate the existence of two crystallographically independent positions for the iron(III) cations and a small proportion of this cation in the positions of the divalent Mn(II) and Co(II) ones. The IR spectrum shows the protonated bands of the H{sub 2}N- groups of the propanediamine molecule and the characteristic bands of the [AsO{sub 4}]{sup 3-} arsenate oxoanions. In the diffuse reflectance spectra, it can be observed the bands characteristic of trivalent iron(III) cation and divalent Mn(II) and Co(II) ones in a distorted octahedral symmetry. The calculated Dq and B-Racah parameters for the cobalt(II) phase are 710 and 925 cm{sup -1}, respectively. The ESR spectra of compound 1 maintain isotropic with variation in temperature, being g = 1.99. Magnetic measurements for both compounds indicate that the main magnetic interactions are antiferromagnetic in nature. However, at low temperatures small ferromagnetic components are detected, which are probably due to a spin decompensation of the two different metallic cations. The hysteresis loops give values of the remnant magnetization and coercive field of 84.5, 255 emu/mol and 0.01, 0.225 T for phases 1 and 2, respectively.

36 MATERIALS SCIENCE↗

Understanding Metal Directed-Assembly Growth of Single-Crystal Organic Nanowires: Time-Resolved, In-Situ X-Ray Diffraction and First-Principles Theoretical Study

The deterministic growth of oriented crystalline organic nanowires (CONs) from the vapor-solid chemical reaction (VSCR) between small-molecule reactants and metal nanoparticles has been demonstrated in several studies to date, however the growth mechanism has not yet been conclusively understood. Here, the VSCR growth of M-TCNQF4 (where M is Cu- or Ag-) nanowires is investigated both experimentally and theoretically with time-resolved, in-situ x-ray diffraction (XRD) and first-principles atomistic calculations, respectively, to understand how metals (M) direct the assembly of small molecules into CONs, and what determines the selectivity of a metal for an organic vapor reactant in the growth process. Analysis of the real-time growth kinetics data using a modified Avrami model indicates that the formation of CONs from VSCR follows a one-dimensional ion diffusion-controlled tip growth mechanism wherein metal ions diffuse from a metal film through the nanowire to its tip where they react with small molecules to continue growth. The experimental data and theoretical calculations indicate that the selectivity of different metals to induce nanowire growth depends strongly upon effective charge transfer between the organic molecules and the metal. Specifically, the experimental finding that Cu ions can exchange and replace Ag ions in Ag-TCNQF4 to form Cu-TCNQF4 nanowires is explained by the significantly stronger chemical bond between Cu and TCNQF4 molecules than for Ag, due to the strong spin-dependent electronic contribution of Cu. Understanding how to control the VSCR growth process may enable the synthesis of novel organic nanowires with axial or coaxial p/n junctions for organic nanoelectronics and solar energy harvesting.

14 SOLAR ENERGY↗

Uncertainty in counting ice nucleating particles with continuous flow diffusion chambers

Abstract. This study investigates the measurement of ice nucleating particle (INP) concentrations and sizing of crystals using continuous flow diffusion chambers (CFDCs). CFDCs have been deployed for decades to measure the formation of INPs under controlled humidity and temperature conditions in laboratory studies and by ambient aerosol populations. These measurements have, in turn, been used to construct parameterizations for use in models by relating the formation of ice crystals to state variables such as temperature and humidity as well as aerosol particle properties such as composition and number. We show here that assumptions of ideal instrument behavior are not supported by measurements made with a commercially available CFDC, the SPectrometer for Ice Nucleation (SPIN), and the instrument on which it is based, the Zurich Ice Nucleation Chamber (ZINC). Non-ideal instrument behavior, which is likely inherent to varying degrees in all CFDCs, is caused by exposure of particles to different humidities and/or temperatures than predicated from instrument theory of operation. This can result in a systematic, and variable, underestimation of reported INP concentrations. We find here variable correction factors from 1.5 to 9.5, consistent with previous literature values. We use a machine learning approach to show that non-ideality is most likely due to small-scale flow features where the aerosols are combined with sheath flows. Machine learning is also used to minimize the uncertainty in measured INP concentrations. We suggest that detailed measurement, on an instrument-by-instrument basis, be performed to characterize this uncertainty.

54 ENVIRONMENTAL SCIENCES↗

Technology application at Rockwell International

Technology diffusion at Rockwell International has progressed from the application of special skills to solve specific problems to the transfer of the required people and skills to allow the commercial divisions to solve their own problems and develop or improve their own products. Our prime effort is concentrated on commercial industrial applications. Rockwell's major emphasis on advanced technology utilization is directed through three operational modes, namely, transfer from technologically developed to underdeveloped organizations within the company; transfer between technologically developed organizations to form new operations within the company; and formation of high technology spin-off organizations beyond the corporate entity.

Meechan, C. J.↗

Postaccretion magnetic field evolution of neutron stars

We present the first calculations of magnetic field evolution following accretion-induced field reduction which demonstrate the possibility of subsequent surface magnetic field growth. Assuming the preaccretion field is pushed down or advected below the accreting material, we show that significant diffusion of the suppressed field back to the surface can occur within a Galactic age approximately 10(exp 10) yr. This produces surface fields characteristic of standard pulsars if the total mass transferred is below a critical value delta M(sub c) approximately 0.04 solar masses. We then show how this provides a natural explanation for the existence of old pulsars with high inferred surface dipole fields which are still observable. Using our results in conjunction with a model for accretion-induced field reduction we predict the evolution of a binary pulsar's spin and magnetic field through its postaccretion lifetime. This analysis also provides a qualitative explanation for a recent suggestion that the magnetic fields and spins of recycled pulsars have a bimodal distribution.

Young, E. J.↗

Superdiffusion resilience in Heisenberg chains with two-dimensional interactions on a quantum processor

Superdiffusive spin transport in the one-dimensional (1D) Heisenberg model is a key theoretical discovery in nonequilibrium quantum many-body physics. Although extensively studied in 1D systems, the breakdown and sustenance of superdiffusion in two-dimensional (2D) lattices with integrability-breaking terms, as found in real materials, remains an open question. To address this, we develop a toy model that extends the 1D Heisenberg model with a representative set of 2D interaction types and tunable strengths. Our model exhibits varying degrees of superdiffusion breakdown depending on the interaction type, spanning ballistic to diffusive regimes. We establish and justify a hierarchy of 2D interactions based on their resilience against superdiffusion breakdown: Heisenberg >𝑋⁢𝑋 > Ising. This precise control over the superdiffusive behavior also enables rigorous benchmarking of quantum hardware, and our simulations on IBM's Heron devices confirm the hardware's ability to accurately capture these many-body nonequilibrium phenomena. Overall, our results are relevant not only to simulating superdiffusion in real materials, such as the 1D Heisenberg compound KCuF3, which contains modest nonintegrable 2D terms, but also to extending superdiffusive behavior to larger 2D qubit lattices and other 2D materials.

Alagarsamy Manikandan, Keerthi Kumaran [ORNL]↗

Textured Nanoporous Mo:BiVO4 Photoanodes with High Charge Transport and Charge Transfer Quantum Efficiencies for Oxygen Evolution

We have developed a simple spin coating method to make high-quality nanoporous photoelectrodes of monoclinic BiVO4 and studied the ability of these electrodes to transport photogenerated carriers to oxidize sulfite and water. Samples containing molybdenum and featuring [001] out-of-plane crystallographic texture show a photocurrent and external quantum efficiency (EQE) for sulfite oxidation as high as 3.1 mA cm-2 and 60%, respectively, at 1.23 V versus reversible hydrogen electrode. By using an optical model of the electrode stack to accurately determine the fraction of electrode absorptance due to the BiVO4 active layer, we estimate that on average 70 +/- 5% of all photogenerated carriers escape recombination. A comparison of internal quantum efficiency as a function of film processing, illumination direction, and film thickness shows that electron transport is efficient and hole transport limits the photocurrent (hole diffusion length <40 nm). We find that Mo addition primarily improves electron transport and texturing mostly improves hole transport. Mo enhances electron transport by thinning the surface depletion layer or passivating traps and recombination centers at grain boundaries and interfaces, while improved hole transport in textured films may result from more efficient lateral hole extraction due to the texturing itself or the reduced density of deep gap states observed in photoemission measurements. Photoemission data also reveal that the films have bismuth-rich, vanadium- and oxygen-deficient surface layers, while ion scattering spectroscopy indicates a Bi-V-O surface termination. Without added catalysts, the plain BiVO4 electrodes oxidized water with an initial photocurrent and peak EQE of 1.7 mA cm-2 and 30%, respectively, which equates to a hole transfer efficiency to water of >64% at 1.23 V. The electrodes quickly photocorrode during water oxidation but show good stability during sulfite oxidation and indefinite stability in the dark. By improving the hole transport efficiency and coating these nanoporous BiVO4 films with an appropriate protective layer and oxygen evolution catalyst, it should be possible to achieve highly efficient and stable water oxidation at a practical pH.

36 MATERIALS SCIENCE↗

Using Density-Corrected DFT to Understand Density-Driven and Functional-Dependent Errors in Ab Initio Simulations of the Hydrated Electron

The hydrated electron, an excess electron in liquid water, plays a crucial role in a plethora of chemical processes, motivating extensive research efforts to characterize its structure, dynamics, and reactivity in solution. Recent theoretical approaches to understanding this intriguing object have involved ab initio simulations based on density functional theory (DFT). Although DFT allows for the study of hydrated electron reactivity and quantum mechanical behavior, it is well-known that anionic systems can suffer from significant density-driven errors (DDEs). Density-corrected DFT (DC-DFT) provides a framework to mitigate such errors; the method reduces DDEs by replacing the self-consistent (SC) density associated with a given density functional with the Hartree–Fock (HF) density. Since HF densities tend to be more localized than DFT SC densities, the DC-DFT scheme significantly improves errors in calculations where the SC density is spuriously delocalized. Here, we investigate how the use of density correction affects the calculated properties of the DFT-simulated (PBEh) hydrated electron, a particularly challenging diffuse anionic system to simulate. First, we analyze charge delocalization in a system consisting of a model octahedral hydrated electron water cluster (the so-called Kevan structure) along with a spatially separated sulfur atom. We show that the use of density correction indeed reduces DDEs in comparison to a standard DFT global hybrid functional. We then propagate molecular dynamics trajectories of the hydrated electron using DC-DFT, where we find that DC further localizes electron density in the cavity region, a signature of reduced charge delocalization. Unfortunately, the decreased radius of gyration of the spin density and corresponding tightening of the local solvation structure from density correction causes predicted observables to deviate further from experimental measurements than when density correction is not employed. Here, we argue that DC’s worse agreement with experiment results from the removal of a fortuitous cancellation of errors that is intrinsic to the PBEh functional. This indicates that the difficulties with DFT to simulate hydrated electrons are primarily due to the inherent approximations in DFT rather than to density-driven errors.

Density functional theory↗

Centrifugal‐driven, reduced‐dimension, planar chromatography

Abstract A fundamental problem with efficiency in capillary action driven planar chromatography results from diminishing flow rates as development proceeds, giving rise to molecular diffusion related band dispersion for most sample types. Overpressure and electrokinetic means to speed flow have been used successfully in TLC. We explore the use of centrifugal force (CF) to drive flow for reduced‐dimension planar platforms (ultra‐TLC, low micrometer features, and nano‐TLC, nanoscale features). The silicon wafer platforms have two forms of continuous 2D arrays created by either photolithography or metal dewetting followed by deep reactive ion etching and coated with porous SiO 2 . The flow pattern is unusual with co‐planar flows above and within the arrays. The effects of parameters such as spin rate, solvent type, and surface character on flow rates is established and can be substantially greater than capillary action flow. Using fluorescent dyes, we investigate retardation factors and chromatographic plate height; the latter falls in the low to sub‐micrometer range. To the best of our knowledge, we demonstrate the first analytical separations performed in pillar arrays using CF to augment solvent flow.

Strickhouser, Rachel B.↗

Binary collisions of dark matter blobs

We describe the model-independent mechanism by which dark matter and dark matter structures heavier than ~ 8 × 10 11 GeV form binary pairs in the early Universe that spin down and merge both in the present and throughout the Universe’s history, producing potentially observable signals. Sufficiently dense dark objects will dominantly collide through binary mergers instead of random collisions. We detail how one would estimate the merger rate accounting for finite size effects, multibody interactions, and friction with the thermal bath. We predict how mergers of dark dense objects could be detected through gravitational and electromagnetic signals, noting that such mergers could be a unique source of high frequency gravitational waves. We rule out objects whose presence would contradict observations of the CMB and diffuse gamma-rays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic structure of triangular lattice compound Tb2Ni0.90Si2.94

AlB 2 -type ternary intermetallic compound Tb 2 Ni 0.90 Si 2.94 (space group P 6=mmm, hP 3, No. 191) was reported to exhibit spin freezing behaviour of the ferromagnetic clusters present in the system below T f = 9:9 K, along with the presence of spatially limited antiferromagnetic phase. In this work, on the basis of variable temperature zero-field neutron diffraction measurements, we have shown that the antiferromagnetic phase transition occurs for the compound below T N ~13 K. Neutron diffraction study indicates ab-plane non-collinear sine-modulated antiferromagnetic ordering of the system with wave vectors of k 1 = [±1/6, ±1/6, 0] and k 2 = [±1/3, ±1/3, 0] down to 1.7 K. The weak and diffuse nature of the magnetic Bragg peaks along with limited coherence length further confirm the short-range nature of the antiferromagnetic phase in this compound.

36 MATERIALS SCIENCE↗

Spectral Addressability in a Modular Two Qubit System

The combination of structural precision and reproducibility of synthetic chemistry is perfectly suited for the creation of chemical qubits, the core units of a quantum information science (QIS) system. By exploiting the atomistic control inherent to synthetic chemistry, we address a fundamental question of how the spin–spin distance between two qubits impacts electronic spin coherence. To achieve this goal, in this study we designed a series of molecules featuring two spectrally distinct qubits, an early transition metal, Ti 3+ , and a late transition metal, Cu 2+ with increasing separation between the two metals. The spectral separation between the two metals enables us to probe each metal individually in the bimetallic species and compare it with monometallic control samples. Coherence times found to be governed by the distance to nuclear spins on the other qubit’s ligand framework. This finding offers guidance for the design of spectrally addressable molecular qubits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Local inversion-symmetry breaking in a bismuthate high-Tc superconductor

Abstract The doped perovskite BaBiO 3 exhibits a maximum superconducting transition temperature ( T c ) of 34 K and was the first high- T c oxide to be discovered, yet pivotal questions regarding the nature of both the metallic and superconducting states remain unresolved. Although it is generally thought that superconductivity in the bismuthates is of the conventional s -wave type, the pairing mechanism is still debated, with strong electron-phonon coupling and bismuth valence or bond disproportionation possibly playing a role. Here we use diffuse x-ray scattering and Monte Carlo modeling to study the local structure of Ba 1-x K x BiO 3 across its insulator-metal boundary. We find no evidence for either long- or short-range disproportionation, which resolves a major conundrum, as disproportionation and the related polaronic effects are likely not relevant for the metallic and superconducting states. Instead, we uncover nanoscale structural correlations that break inversion symmetry, with far-reaching implications for the electronic physics. This unexpected finding furthermore establishes that the bismuthates belong to the broader classes of materials with hidden spin-orbit coupling and a tendency towards inversion-breaking displacements.

36 MATERIALS SCIENCE↗

A new concept of plasma motion and planetary magenetic field for Venus

It is shown that the magnetohydrodynamic conditions of the Venus ionosphere near the terminator favor convection of a magnetic field rather than diffusion. Consequently, any planetary magnetic field which Venus may possess will be strongly affected by the global antisunward flow of the ionosphere which has been revealed by the Pioneer-Venus retarding potential analyzer. The magnetic flux from an internal magnetic field will accumulate in the night hemisphere. Details of the structure and dynamics of such accumulations depend on particular details of the magnetic field source and the time-dependent plasma flow pattern, but a simple interpretation of observational data yields a magnetic dipole moment of 7 x 10 to the 20th cu cm directed along the planet spin vector.

Knudsen, W. C.↗

TU-EF-BRA-00: MR Basics I

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI (f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-01: NMR and Proton Density MRI of the 1D Patient

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-02: Longitudinal Proton Spin Relaxation and T1-Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗