Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Acoustic Methods to Monitor Protein Crystallization and to Detect Protein Crystals in Suspensions of Agarose and Lipidic Cubic Phase

Improvements needed for automated crystallography include crystal detection and crystal harvesting. A technique that uses acoustic droplet ejection to harvest crystals was previously reported. Here a method is described for using the same acoustic instrument to detect protein crystals and to monitor crystal growth. Acoustic pulses were used to monitor the progress of crystallization trials and to detect the presence and location of protein crystals. Crystals were detected, and crystallization was monitored in aqueous solutions and in lipidic cubic phase. Using a commercially available acoustic instrument, crystals measuring ~150 µm or larger were readily detected. Simple laboratory techniques were used to increase the sensitivity to 50 µm by suspending the crystals away from the plastic surface of the crystallization plate. This increased the sensitivity by separating the strong signal generated by the plate bottom that can mask the signal from small protein crystals. It is possible to further boost the acoustic reflection from small crystals by reducing the wavelength of the incident sound pulse, but our current instrumentation does not allow this option. In the future, commercially available sound-emitting transducers with a characteristic frequency near 300 MHz should detect and monitor the growth of individual 3 µm crystals.

59 BASIC BIOLOGICAL SCIENCES↗

Verification of optical modelling of sunshape and surface slope error for concentrating solar power systems

Sunshape and reflector surface slope error distributions are significant elements in modelling the optical behaviour of a concentrating solar power system. Different optical modelling tools implement these elements with various approaches. Discrepancies can easily accumulate in simulations of a large optical system as a result of incorrect implementations. This study reviews and verifies the implementations of these two factors in six tools that are widely used for optical modelling in solar energy research: Tonatiuh, SolTrace, Tracer, Solstice, Heliosim and SolarPILOT. The review incorporates three rounds of tests. Firstly, basic tests examine each factor carefully in simplified on-axis reflector-target configurations (round 'A'). Secondly, off-axis effects are introduced (round 'B'). Thirdly, full heliostat field simulations are verified (round 'C'). All of the test cases are simulated with each modelling tool, and results are compared. Discrepancies were observed due to approximations inherent in the cone optics (convolution) methods, incorrect implementation the of pillbox slope errors, different approaches to setting the circumsolar ratio for the Buie sunshape, and different approaches to the calculation of blocking and shading losses in some tools. All issues are discussed fully, and solutions to most issues were implemented within the scope of the present study. Some remaining issues are noted. The study highlights the importance of careful implementation of these aspects of optical modelling and contributes to an improvement in the quality of several widely-used tools.

14 SOLAR ENERGY↗

High vacuum cells for classical surface techniques

Novel glass cells were designed and built to be able to perform surface potential and surface tension measurements in a contained environment. The cells can withstand pressures of approximately 1x10{sup -6} Torr, providing a reasonable level of control in terms of the amounts of volatile contaminants during experimentation. The measurements can take several hours; thus the cells help maintain the integrity of the sample in the course of the experiment. To test for the feasibility of the cell design, calibration measurements were performed. For the surface potential cell, the modified TREK 6000B-7C probe exhibited performance comparable to its unmodified counterpart. The correlation measurements between applied potential on the test surface and the measured potential showed R-values very close to 1 as well as standard deviation values of less than 1. Results also demonstrate improved measurement values for experiments performed in vacuum. The surface tension cell, on the other hand, which was used to perform the pendant drop method, was tested on common liquids and showed percentage errors of 0.5% when compared to literature values. The fabricated cells redefine measurements using classical surface techniques, providing unique and novel methods of sample preparation, premeasurement preparation, and sample analysis at highly beneficial expenditure cost.

36 MATERIALS SCIENCE↗

A comprehensive laboratory study on the immersion freezing behavior of illite NX particles. A comparison of 17 ice nucleation measurement techniques

Immersion freezing is the most relevant heterogeneous ice nucleation mechanism through which ice crystals are formed in mixed-phase clouds. In recent years, an increasing number of laboratory experiments utilizing a variety of instruments have examined immersion freezing activity of atmospherically relevant ice-nucleating particles. However, an intercomparison of these laboratory results is a difficult task because investigators have used different ice nucleation (IN) measurement methods to produce these results. A remaining challenge is to explore the sensitivity and accuracy of these techniques and to understand how the IN results are potentially influenced or biased by experimental parameters associated with these techniques. Within the framework of INUIT (Ice Nuclei Research Unit), we distributed an illite-rich sample (illite NX) as a representative surrogate for atmospheric mineral dust particles to investigators to perform immersion freezing experiments using different IN measurement methods and to obtain IN data as a function of particle concentration, temperature ( T ), cooling rate and nucleation time. A total of 17 measurement methods were involved in the data intercomparison. Experiments with seven instruments started with the test sample pre-suspended in water before cooling, while 10 other instruments employed water vapor condensation onto dry-dispersed particles followed by immersion freezing. The resulting comprehensive immersion freezing data set was evaluated using the ice nucleation active surface-site density, n s , to develop a representative n s ( T ) spectrum that spans a wide temperature range (-37 °C < T < -11 °C) and covers 9 orders of magnitude in n s . In general, the 17 immersion freezing measurement techniques deviate, within a range of about 8 °C in terms of temperature, by 3 orders of magnitude with respect to n s . In addition, we show evidence that the immersion freezing efficiency expressed in n s of illite NX particles is relatively independent of droplet size, particle mass in suspension, particle size and cooling rate during freezing. A strong temperature dependence and weak time and size dependence of the immersion freezing efficiency of illite-rich clay mineral particles enabled the n s parameterization solely as a function of temperature. We also characterized the n s ( T ) spectra and identified a section with a steep slope between -20 and -27 °C, where a large fraction of active sites of our test dust may trigger immersion freezing. This slope was followed by a region with a gentler slope at temperatures below -27 °C. While the agreement between different instruments was reasonable below ~ -27 °C, there seemed to be a different trend in the temperature-dependent ice nucleation activity from the suspension and dry-dispersed particle measurements for this mineral dust, in particular at higher temperatures. For instance, the ice nucleation activity expressed in n s was smaller for the average of the wet suspended samples and higher for the average of the dry-dispersed aerosol samples between about -27 and -18 °C. Only instruments making measurements with wet suspended samples were able to measure ice nucleation above -18 °C. A possible explanation for the deviation between -27 and -18 °C is discussed. Multiple exponential distribution fits in both linear and log space for both specific surface area-based n s ( T ) and geometric surface area-based n s ( T ) are provided. These new fits, constrained by using identical reference samples, will help to compare IN measurement methods that are not included in the present study and IN data from future IN instruments.

54 ENVIRONMENTAL SCIENCES↗

Surface daytime net radiation estimation using artificial neural networks

Net all-wave surface radiation (R n ) is one of the most important fundamental parameters in various applications. However, conventional R n measurements are difficult to collect because of the high cost and ongoing maintenance of recording instruments. Therefore, various empirical R n estimation models have been developed. This study presents the results of two artificial neural network (ANN) models (general regression neural networks (GRNN) and Neuroet) to estimate R n globally from multi-source data, including remotely sensed products, surface measurements, and meteorological reanalysis products. R n estimates provided by the two ANNs were tested against in-situ radiation measurements obtained from 251 global sites between 1991–2010 both in global mode (all data were used to fit the models) and in conditional mode (the data were divided into four subsets and the models were fitted separately). Based on the results obtained from extensive experiments, it has been proved that the two ANNs were superior to linear-based empirical models in both global and conditional modes and that the GRNN performed better and was more stable than Neuroet. The GRNN estimates had a determination coefficient (R 2 ) of 0.92, a root mean square error (RMSE) of 34.27 W·m –2 , and a bias of –0.61 W·m –2 in global mode based on the validation dataset. In conclusion, ANN methods are a potentially powerful tool for global R n estimation.

14 SOLAR ENERGY↗

Nondestructive characterization of UHMWPE armor materials

Ultra-high molecular weight polyethylene (UHMWPE) is a material increasingly used for fabricating helmet and body armor. In this work, plate specimens consolidated from thin fiber sheets in series 3124 and 3130 were examined with ultrasound, X-ray and terahertz radiation. Ultrasonic through-transmission scans using both air-coupled and immersion modes revealed that the 3130 series material generally had much lower attenuation than the 3124 series, and that certain 3124 plates had extremely high attenuation. Due to the relatively low inspection frequencies used, pulse-echo immersion ultrasonic testing could not detect distinct flaw echoes from the interior. To characterize the nature of the defective condition that was responsible for the high ultrasonic attenuation, terahertz radiation in the time-domain spectroscopy mode were used to image the flaws. Terahertz scan images obtained on the high attenuation samples clearly showed a distribution of a large number of defects, possibly small planar delaminations, throughout the volume of the interior. Their precise nature and morphology are to be verified by optical microscopy of the sectioned surface.

36 MATERIALS SCIENCE↗

Micro-Laser-Induced Breakdown Spectroscopy: A Novel Approach Used in the Detection of Six Rare Earths and One Transition Metal

Laser-induced breakdown spectroscopy (LIBS) was undertaken using an instrument which used a high-powered microscope to deliver the light and tightly focused the low energy laser beam onto the surface of a solid sample. A micro-plasma was generated on the surface of the sample under test even though the amount of energy/pulse from a beam of 532 nm was <1 mJ. Rare earth elements such as europium, gadolinium, lanthanum, neodymium, praseodymium, samarium, and a transition metal, yttrium, were tested. These elements are important in nuclear fission reactions especially for estimation of actinide masses for non-proliferation “safeguards”. Each element was mixed in the graphite matrix in different percentages from 1% to 50% by weight and the LIBS spectra were obtained for each composition as well as after mixing each element in the same amount using oxides of the elements. The data for the 5% mixture of the rare earth elements with graphite powder along with the transition metal has been presented in this article. A micro-LIBS approach was used to demonstrate that these rare earth elements can be identified individually and in a complex mixture in glove boxes in which the microscope LIBS instrument is housed in a nuclear research environment.

36 MATERIALS SCIENCE↗

Estimation of wintertime cloud radiative effects in the Western Arctic, a function of cloud-moisture-coupling and sea ice conditions

Cloud radiative effects are estimated using up- and downward ground-based observations of broadband thermal infrared sensors in cloudy conditions which are provided by the ARM data repository. The ARM Surface Radiation measurement is analyzed. To study the cloud radiative effects, the observed thermal infrared measurements under cloudy conditions are analyzed together with microphysical cloud properties like liquid and ice water path obtained from the CloudNet algorithms applied to the remote-sensing instrumentation suite at the ARM site in Utqiagvik. Cloud observations have been sorted depending on the coupling of the cloud with upwind water vapor transport events that can interact with sea ice upwind. Statistics of surface net thermal fluxes and cloud water/ice properties show a distinguished distribution for coupled and decoupled clouds. It was found that coupled clouds contain more liquid water and are more efficient reduce the cooling of surface LW radiation.

54 ENVIRONMENTAL SCIENCES↗

VLT/SINFONI OBSERVATIONS OF EUROPA: NEW INSIGHTS INTO THE SURFACE COMPOSITION

We present new insights into Europa’s surface composition on the global scale from linear spectral modeling of a high spectral resolution data set acquired during a ground-based observation campaign using SINFONI{sup 4}, an adaptive optics near-infrared instrument on the Very Large Telescope (ESO). The spectral modeling confirms the typical “bullseye” distribution of sulfuric acid hydrate on the trailing hemisphere, which is consistent with Iogenic sulfur ion implantation. However, the traditional hypothesis of the presence of sulfate salts on the surface of the satellite is challenged as Mg-bearing chlorinated species (chloride, chlorate, and perchlorate) are found to provide improved spectral fits. The derived global distribution of Mg-chlorinated salts (and particularly chloride) is correlated with large-scale geomorphologic units such as chaos and darker areas, thus suggesting an endogenous origin. Based on the 1.65 μ m water-ice absorption band shape and position, the surface temperature is estimated to be in the range 110–130 K, and water ice is found to be predominantly in its crystalline state rather than amorphous. While amorphous water ice exhibits a strong correlation with the expected intensity of the Ionian plasma torus bombardment, crystalline water ice is instead more associated with distinct geomorphological units. Endogenous processes such as jets and ice heating due to active geology may explain this relationship. Otherwise, no evidence of a correlation between grain size for the water ice and the sputtering rate has been detected so far.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron cyclotron emission reconstruction image and m/n=3/2 mode in HT-7 tokamak

Electron cyclotron emission reconstruction image has been used for flux surface reconstruction. The reconstruction image is based on plasma rigid rotation which is obtained from Mirnov diagnostic. From the reconstructed two-dimensional flux surface, the classical m/n=3/2 mode is visualized, which is of similar spatial structure as neoclassical 3/2 mode observed in some other tokamaks [B. Esposito et al., Phys. Rev. Lett. 100, 045006 (2008)].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Figure correction of a metallic ellipsoidal neutron focusing mirror

An increasing number of neutron focusing mirrors is being adopted in neutron scattering experiments in order to provide high fluxes at sample positions, reduce measurement time, and/or increase statistical reliability. To realize a small focusing spot and high beam intensity, mirrors with both high form accuracy and low surface roughness are required. To achieve this, we propose a new figure correction technique to fabricate a two-dimensional neutron focusing mirror made with electroless nickel-phosphorus (NiP) by effectively combining ultraprecision shaper cutting and fine polishing. An arc envelope shaper cutting method is introduced to generate high form accuracy, while a fine polishing method, in which the material is removed effectively without losing profile accuracy, is developed to reduce the surface roughness of the mirror. High form accuracy in the minor-axis and the major-axis is obtained through tool profile error compensation and corrective polishing, respectively, and low surface roughness is acquired under a low polishing load. As a result, an ellipsoidal neutron focusing mirror is successfully fabricated with high form accuracy of 0.5 μm peak-to-valley and low surface roughness of 0.2 nm root-mean-square.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of fast heating electron beam annealing setup for ultra high vacuum chamber

We report the design and development of a simple, electrically low powered and fast heating versatile electron beam annealing setup (up to 1000 °C) working with ultra high vacuum (UHV) chamber for annealing thin films and multilayer structures. The important features of the system are constant temperature control in UHV conditions for the temperature range from room temperature to 1000 ºC with sufficient power of 330 W, at constant vacuum during annealing treatment. It takes approximately 6 min to reach 1000 °C from room temperature (∼10{sup −6} mbar) and 45 min to cool down without any extra cooling. The annealing setup consists of a UHV chamber, sample holder, heating arrangement mounted on suitable UHV electrical feed-through and electronic control and feedback systems to control the temperature within ±1 ºC of set value. The outside of the vacuum chamber is cooled by cold air of 20 °C of air conditioning machine used for the laboratory, so that chamber temperature does not go beyond 50 °C when target temperature is maximum. The probability of surface oxidation or surface contamination during annealing is examined by means of x-ray photoelectron spectroscopy of virgin Cu sample annealed at 1000 °C.

36 MATERIALS SCIENCE↗

SHOCKED SURFACE STEREO IMAGING WITH FIBER-OPTIC IMAGING PROBES

“A picture tells a thousand words”—this is a concept that captivates everyone, from the casual observer to the experimental physics scientist. To bring this concept to light in support of Stockpile Stewardship subcritical experiments executed at the Nevada National Security Site (NNSS), we have developed a new diagnostic tool to investigate the behavior of materials under high-explosive dynamic shock conditions. For the Leda subcritical experiment executed in August, 2014, a single line-of-sight imaging system was designed and fielded as a stretch diagnostic goal for National Security Technologies, LLC (NSTec). For the Lyra series, beginning with the Orpheus experiment in September 2015, a newly created dynamic stereo surface imaging (DSSI) capability was deployed. The DSSI diagnostic records a high-speed image sequence that allows scientists to peer inside an imploding hydrodynamic test article with stereoscopic imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface purity control during XMASS detector refurbishment

The XMASS project aims at detecting dark matter, pp and {sup 7}Be solar neutrinos, and neutrino less double beta decay using large volume of pure liquid xenon. The first physics target of the XMASS project is to detect dark matter with 835 kg liquid xenon. After the commissioning runs, XMASS detector was refurbished to minimize the background contribution mainly from PMT sealing material and we restarted data taking in November 2013. We report how we control surface purity, especially how we prevent radon daughter accumulation on the detector copper surface, during XMASS detector refurbishment. The result and future plan of XMASS are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrahigh-resolution spin-resolved photoemission spectrometer with a mini Mott detector

We have developed an ultrahigh-resolution spin-resolved photoemission spectrometer with a highly efficient mini Mott detector and an intense xenon plasma discharge lamp. The spectrometer achieves the energy resolutions of 0.9 and 8 meV for non-spin-resolved and spin-resolved modes, respectively. Three-dimensional spin-polarization is determined by using a 90 deg. electron deflector situated before the Mott detector. The performance of spectrometer is demonstrated by observation of a clear Rashba splitting of the Bi(111) surface states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗