Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Technical Design Report for the FACET-II Project at SLAC National Accelerator Laboratory

Electrons can “surf” on waves of plasma – a hot gas of charged particles – gaining very high energies in very short distances. This approach, called plasma wakefield acceleration, has the potential to dramatically shrink the size and cost of particle accelerators. Research at the SLAC National Accelerator Laboratory has demonstrated that plasmas can provide 1,000 times the acceleration in a given distance compared with current technologies. Developing revolutionary and more efficient acceleration techniques that allow for an affordable high-energy collider has been the focus of FACET, a National User Facility at SLAC. FACET used part of SLAC’s two-mile-long linear accelerator to generate high-density beams of electrons and their antimatter counterparts, positrons. Research into plasma wakefield acceleration was the primary motivation for constructing FACET. In April 2016, FACET operations came to an end to make way for the second phase of SLAC’s x-ray laser, the LCLS-II, which will use part of the tunnel occupied by FACET. FACET-II is a new test facility to provide the unique capability to develop advanced acceleration and coherent radiation techniques with high-energy electron and positron beams. FACET-II represents a major upgrade over current FACET capabilities and the breadth of the potential research program makes it truly unique.

43 PARTICLE ACCELERATORS↗

Extraction simulations and emittance measurements of a Holifield Radioactive Ion Beam Facility electron beam plasma source for radioactive ion beams

The Holifield Radioactive Ion Beam Facility HRIBF at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams RIBs. Of these, the workhorse is an electron beam plasma EBP ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 IRIS2, for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

43 PARTICLE ACCELERATORS↗

Pressure drop measurements across a helical coil steam generator configuration - 15997

The primary heat transport loop heat exchanger within a Very-High Temperature Reactor (VHTR) is most commonly a Helical Coil Steam Generator (HCSG). This design has been regarded as having increased heat transfer within a smaller design in comparison to other heat exchangers. The fluidic heat transfer properties of the HCSG is still under evaluation in tangent with HTRs due to its complex design. Heat transfer between these layers relies heavily on their relative location and fluidic properties. A model was constructed to study the pressure field on a rod s surface as well as across multiple layers of helically facing tubes. Experiments focused on evaluating the impact relative geometry played on the overall pressure drop of the test section with inlet fluid velocity ranging from 0 to 3 m/s. A study to compare the experimental results with the Gaddis-Gnielinski Correlative theoretical values of pressure drop in tube bundles shows that the complex helical geometry results in pressure drops similar to that of fully developed rod bundle although the test facility is comprised of two half rod helical coils. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Extraction simulations and emittance measurements of a Holifield Radioactive Ion Beam Facility electron beam plasma source for radioactive ion beams

The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams (RIBs). Of these, the workhorse is an electron beam plasma (EBP) ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 (IRIS2), for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

43 PARTICLE ACCELERATORS↗

Gravity-Based Non-Invasive System for Reactor Coolant Inventory Monitoring

This paper summarizes the progress in the use of non-invasive methods for measuring liquid level in small modular nuclear reactors. High precision gravimeters are used to measure changes in liquid level in a test facility environment, and results are compared to simulations. Possible configurations for the meters use in the NuScale SMR are also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pulse shaping and energy storage capabilities of angularly multiplexed KrF laser fusion drivers

This paper describes a rep-rated multibeam KrF laser driver design for the 500 kJ Inertial Fusion test Facility (FTF) recently proposed by NRL, then models its optical pulse shaping capabilities using the ORESTES laser kinetics code. It describes a stable and reliable iteration technique for calculating the required precompensated input pulse shape that will achieve the desired output shape, even when the amplifiers are heavily saturated. It also describes how this precompensation technique could be experimentally implemented in real time on a reprated laser system. The simulations show that this multibeam system can achieve a high fidelity pulse shaping capability, even for a high gain shock ignition pulse whose final spike requires output intensities much higher than the approx4 MW/cm{sup 2} saturation levels associated with quasi-cw operation; i.e., they show that KrF can act as a storage medium even for pulsewidths of approx1 ns. For the chosen pulse, which gives a predicted fusion energy gain of approx120, the simulations predict the FTF can deliver a total on-target energy of 428 kJ, a peak spike power of 385 TW, and amplified spontaneous emission prepulse contrast ratios I{sub ASE}/I<3x10{sup -7} in intensity and F{sub ASE}/F<1.5x10{sup -5} in fluence. Finally, the paper proposes a front-end pulse shaping technique that combines an optical Kerr gate with cw 248 nm light and a 1 mum control beam shaped by advanced fiber optic technology, such as the one used in the National Ignition Facility (NIF) laser.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transformer ratio improvement for beam based plasma accelerators

Increasing the transformer ratio of wakefield accelerating systems improves the viability of present novel accelerating schemes. The use of asymmetric bunches to improve the transformer ratio of beam based plasma systems has been proposed for some time[1, 2] but suffered from lack appropriate beam creation systems. Recently these impediments have been overcome [3, 4] and the ability now exists to create bunches with current profiles shaped to overcome the symmetric beam limit of R {<=} 2. We present here work towards experiments designed to measure the transformer ratio of such beams, including theoretical models and simulations using VORPAL (a 3D capable PIC code) [5]. Specifically we discuss projects to be carried out in the quasi-nonlinear regime [6] at the UCLA Neptune Laboratory and the Accelerator Test Facility at Brookhaven National Lab.

43 PARTICLE ACCELERATORS↗

Recent Progress At The Idaho National Laboratory In High Temperature Electrolysis For Hydrogen And Syngas Production

This paper presents the most recent results of experiments conducted at the Idaho National Laboratory (INL) studying electrolysis of steam and coelectrolysis of steam / carbon dioxide in solid-oxide electrolysis stacks. Single button cell tests as well as multi-cell stack testing have been conducted. Multi-cell stack testing used 10 x 10 cm cells (8 x 8 cm active area) supplied by Ceramatec, Inc (Salt Lake City, Utah, USA) and ranged from 10 cell short stacks to 240 cell modules. Tests were conducted either in a bench-scale test apparatus or in a newly developed 5 kW Integrated Laboratory Scale (ILS) test facility. Gas composition, operating voltage, and operating temperature were varied during testing. The tests were heavily instrumented, and outlet gas compositions were monitored with a gas chromatograph. The ILS facility is currently being expanded to 15 kW testing capacity (H2 production rate based upon lower heating value).

08 HYDROGEN↗

Idaho National Laboratory Experimental Research In High Temperature Electrolysis For Hydrogen And Syngas Production

The Idaho National Laboratory (Idaho Falls, Idaho, USA), in collaboration with Ceramatec, Inc. (Salt Lake City, Utah, USA), is actively researching the application of solid oxide fuel cell technology as electrolyzers for large scale hydrogen and syngas production. This technology relies upon electricity and high temperature heat to chemically reduce a steam or steam / CO2 feedstock. Single button cell tests, multi-cell stack, as well as multi-stack testing has been conducted. Stack testing used 10 x 10 cm cells (8 x 8 cm active area) supplied by Ceramatec and ranged from 10 cell short stacks to 240 cell modules. Tests were conducted either in a bench-scale test apparatus or in a newly developed 5 kW Integrated Laboratory Scale (ILS) test facility. Gas composition, operating voltage, and operating temperature were varied during testing. The tests were heavily instrumented, and outlet gas compositions were monitored with a gas chromatograph. The ILS facility is currently being expanded to ~15 kW testing capacity (H2 production rate based upon lower heating value).

08 HYDROGEN↗

Radiation characterization summary of the NETL beam port 1/5 free-field environment at the 128-inch core centerline adjacent location

The characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields in the University of Texas at Austin Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor for the beam port (BP) 1/5 free-field environment at the 128-inch location adjacent to the core centerline has been accomplished. NETL is being explored as an auxiliary neutron test facility for the Sandia National Laboratories radiation effects sciences research and development campaigns. The NETL reactor is a TRIGA Mark-II pulse and steady-state, above-ground pool-type reactor. NETL is intended as a university research reactor typically used to perform irradiation experiments for students and customers, radioisotope production, as well as a training reactor. Initial criticality of the NETL TRIGA reactor was achieved on March 12, 1992, making it one of the newest test reactor facilities in the US. The neutron energy spectra, uncertainties, and covariance matrices are presented as well as a neutron fluence map of the experiment area of the cavity. For an unmoderated condition, the neutron fluence at the center of BP 1/5, at the adjacent core axial centerline, is about 8.2×10 12 n/cm 2 per MJ of reactor energy. About 67% of the neutron fluence is below 1 keV and 22% above 100 keV. The 1-MeV Damage-Equivalent Silicon (DES) fluence is roughly 1.6×10 12 n/cm 2 per MJ of reactor energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ITEP MEVVA ion beam for reactor material investigation

Since 2008 the ion beam irradiation modeling experiments for the testing of reactor materials radiation hardness are under development at the ITEP heavy ion RFQ injector with MEVVA ion source. Ion beam irradiation method has certain advantages for such tests. One of them is high speed of defect formation. Moreover, the irradiated samples can be investigated by traditional investigation methodic because they have not radioactivity induced. The special sample support with electrostatic deflector was constructed and installed at the injector output. The result of ion beam dynamics simulation throughout the deflector as well as the detailed description of the test facility is presented. The first experimental results are presented as well. They have been demonstrated promising results.

36 MATERIALS SCIENCE↗

Preliminary Report on Oak Ridge National Laboratory Testing of Drake/ACSS/MA2/E3X

A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of a new conductor technology under real world conditions. The facility is set up to capture large amounts of data during testing. General Cable used the ORNL PCAT facility to validate the performance of TransPowr with E3X Technology a standard overhead conductor with an inorganic high emissivity, low absorptivity surface coating. Extensive testing has demonstrated a significant improvement in conductor performance across a wide range of operating temperatures, indicating that E3X Technology can provide a reduction in temperature, a reduction in sag, and an increase in ampacity when applied to the surface of any overhead conductor. This report provides initial results of that testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

First high gradient test results of a dressed 325 MHz superconducting single spoke resonator at Fermilab

A new superconducting RF cavity test facility has been commissioned at Fermilab in conjunction with first tests of a 325 MHz, {beta} = 0.22 superconducting single-spoke cavity dressed with a helium jacket and prototype tuner. The facility is described and results of full gradient, CW cavity tests with a high Q{sub ext} drive coupler are reported. Sensitivities to Q disease and externally applied magnetic fields were investigated. Results are compared to bare cavity results obtained prior to hydrogen degassing and welding into the helium jacket.

43 PARTICLE ACCELERATORS↗

Investigation of similarity metrics for simulation based scaling analysis

Scaling analysis is a technique for characterizing degree of similarity between processes to occur in a real prototypic system and those to occur in its reduced scale (experimental) analog. In the context of nuclear reactor thermal-hydraulics and safety, scaling analysis is instrumental in assessing the applicability of data obtained from a scaled test facility for calibration of models and validation of simulation codes. Quantification of scale-related distortions is the key element in scaling analysis. In this work, we examine an approach for scaling analysis using computer simulation codes. Similarity analysis using information-theoretic approach is performed by comparing performance of experiment and application to variation of system conditions. Three different information theoretic measures namely mutual information, Kullback-Leibler divergence and overlap coefficient are selected for their potential use as metric for similarity analysis. We test the metrics by comparing them against physics-based scaling ratios, which are well known in fundamental thermal-hydraulic processes. In this exploratory analysis, a case of pressure drop of a steady-state flow through a channel is employed to test the proposed approach. It was found that in the absence of model uncertainties, mutual information serve as an effective measure of the scale effects present in the experiment. However, model uncertainty can significantly impact the quality of similarity analysis. Our analysis indicates that model uncertainties can have significant impact on the information theoretic metrics used for scaling analysis. Furthermore, if the model uncertainties exceeds beyond a critical value, the scale effect present in the experiment cannot be adequately evaluated. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental study on heat transfer to supercritical water flowing through tubes

A test facility named SWAMUP (Supercritical Water Multi-Purpose Loop) has been constructed in Shanghai Jiao Tong Univ. to investigate heat transfer and pressure drop through tubes and rod bundles. SWAMUP is a closed loop with operating pressure up to 30 MPa, outlet-water temperature up to 550 deg. C, and mass flow rate up to 5 t/h. In this paper, experimental study has been carried out on heat transfer of supercritical water flowing vertically through tubes (ID=7.6 and 10 mm). A large number of test points in tubes has been obtained with a wide range of heat flux (200-1500 kw/m{sup 2}) and mass flux (450-2000 kg/m{sup 2}s). Test results showed that heat transfer deterioration (HTD) caused by buoyancy effect only appears in upward flow and HTD caused by acceleration effect appears both in upward flow and downward flow. The heat transfer coefficients (HTC) produced in tube tests were compared with existing heat transfer correlations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electron Cyclotron Resonance Heating for W7-X

The HELIAS-type Stellarator Wendelstein 7-X, which is currently under construction in Greifswald, Germany, will be equipped with a 140 GHz, 10 MW, CW ECRH system. It will be the main plasma heating system for W7-X. The key features and capabilities of the ECRH plant will be discussed together with the envisaged start-up and heating scenarios. We also report on the ECRH stray radiation test facility MISTRAL and on the extension of the gyrotron frequency range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical study of self modulation instability of 1 nC electron bunch at ATF

The development of self-modulation instability (SMI) is investigated numerically for the 1 nC electron bunch available at Accelerator Test Facility (ATF) of Brookhaven National Laboratory (BNL). Possible experiment based on the simulation results is proposed. All the simulations are performed with the 2D-cylindrically symmetric particle-in-cell code.

43 PARTICLE ACCELERATORS↗

Report on Oak Ridge National Laboratory Testing of Ambient Cure TransPowr E3X®

A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of novel overhead conductor and conductor instrumentation under field conditions. The facility is set up to capture large amounts of data during testing. General Cable used the ORNL PCAT facility to validate the performance of TransPowr® with Ambient Cure E3X™ Technology—a standard overhead conductor with a high emissivity, low absorptivity ambient cure surface coating. Extensive testing has demonstrated a significant improvement in conductor performance across a wide range of operating temperatures with respect to uncoated conductor of the same type, indicating that E3X Technology can provide a reduction in temperature, a reduction in sag, and an increase in ampacity when applied to the surface of any overhead conductor. This report provides results of that testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗