Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Time-resolved atomic-resolution Brownian tomography of single nanocrystals reveals size-dependent dynamics

Atomic-resolution structure identification of nanocrystals by graphene liquid cell electron microscopy (GLC-EM) has revealed that small, solubilized platinum nanocrystals consist of an ordered crystalline core surrounded by mobile surface atoms, which dissociate during oxidative etching, resulting in distinct temporal structural states. Requirements imposed by the 3D reconstruction algorithm limit the number of structural states that can be resolved. We introduce a regularized 3D reconstruction algorithm that exploits the redundancy inherent in the experimental data, allowing us to improve the time resolution. Our developments provide a comprehensive molecular picture at unprecedented spatial and temporal resolution of the nonlinear, linear, and fluctuating dynamic phenomena that single nanocrystals undergo during the GLC-EM experiment. We determined atomic structures of 66 temporal structural states, extracted from 15 time trajectories of individual nanocrystals. Large (478 to 698 atoms) and small (<300 atoms) nanocrystals show etching that preserves a stable core, whereas mid-sized (351 to 571 atoms) nanocrystals present dynamics that change the coordination of the core.

Meana-Pañeda, Rubén↗

Space- and time-resolved resistive measurements of liquid metal wall thickness

In a fusion reactor internally coated with liquid metal, it will be important to diagnose the thickness of the liquid at various locations in the vessel, as a function of time, and possibly respond to counteract undesired bulging or depletion. The electrical conductance between electrodes immersed in the liquid metal can be used as a simple proxy for the local thickness. Here a matrix of electrodes is shown to provide spatially and temporally resolved measurements of liquid metal thickness in the absence of plasma. First a theory is developed for m × n electrodes, and then it is experimentally demonstrated for 3 × 1 electrodes, as the liquid stands still or is agitated by means of a shaker. The experiments were carried out with Galinstan, but are easily extended to lithium or other liquid metals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Resolved Molecular Characterization of Limonene/Ozone Aerosol using High-Resolution Electrospray Ionization Mass Spectrometry

Molecular composition of limonene/O3 secondary organic aerosol (SOA) was investigated using high-resolution electrospray ionization mass spectrometry (HR-ESI-MS) as a function of reaction time. SOA was generated by ozonation of D-limonene in a reaction chamber and sampled at different time intervals using a cascade impactor. The SOA samples were extracted into acetonitrile and analyzed using a HR-ESI-MS instrument with a resolving power of 100,000 (m/Δm). The resulting mass spectra provided detailed information about the extent of oxidation inferred from the O:C ratios, double bond equivalency (DBE) factors, and aromaticity indexes (AI) in hundreds of identified individual SOA species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physical limits of semiconductor laser operation: A time-resolved analysis of catastrophic optical damage

The early stages of catastrophic optical damage (COD) in 808 nm emitting diode lasers are mapped by simultaneously monitoring the optical emission with a 1 ns time resolution and deriving the device temperature from thermal images. COD occurs in highly localized damage regions on a 30 to 400 ns time scale which is determined by the accumulation of excess energy absorbed from the optical output. We identify regimes in which COD is avoided by the proper choice of operation parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Space-Time Resolved Approach for Interacting Quantum Field Theories

An alternative approach to the usual perturbative S-matrix evaluation of quantum field theories is presented which is nonperturbative and provides full space-time resolution. We study the dynamical development of the force between two fermion wave packets for the Yukawa system. The spatial distribution of the virtual bosons that act as mediators of the force can be analyzed along with the fermionic densities. Using a potential function for the fermion-fermion interaction is a good approximation to the field theoretical calculations when the Fock space is restricted to only one boson, but in the full quantum field theory the fermion-fermion force is enhanced by higher-order multiboson processes. Furthermore, the normally attractive fermion-fermion Yukawa force can, in principle, be manipulated to even be repulsive if the momentum modes available to the virtual bosons are restricted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Monte Carlo technique to model performance of streak camera-based time-resolving x-ray spectrometers

A Monte Carlo technique has been developed to simulate the expected signal and the statistical noise of x-ray spectrometers that use streak cameras to achieve the time resolution required for ultrafast diagnostics of laser-generated plasmas. The technique accounts for statistics from both the photons incident on the streak camera’s photocathode and the electrons emitted by the photocathode travelling through the camera’s electron optics to the sensor. We use the technique to optimize the design of a spectrometer, which deduces the temporal history of electron temperature of the hotspot in an inertial confinement fusion implosion from its hard x-ray continuum emission spectra. The technique is general enough to be applied to any instrument using an x-ray streak camera.

Stoupin, S. (ORCID:0000000226225270)↗

All-optical Time-resolved Measurement of Laser Energy Modulation in a Relativistic Electron Beam

Hamiltonian light-front theory has been proposed as a promising method for solving bound states problems in quantum field theory a long time ago, see, e.g., the review article[1] for its various advantages compared to the traditional instant-form theories. Recently the Basis Light-Front Quantization (BLFQ) approach [2, 3] has been developed as a nonperturbative approach to solve Hamiltonian light-front quantum field theory. Numerical efficiency is a key advantage of this approach. The basic idea of BLFQ is to represent the theory in an optimal basis which respects many symmetries of the theory and thus minimizes the dimensionality of the Hamiltonian for a fixed precision. Specifically, the BLFQ approach employs a plane wave basis in the light-front longitudinal direction and a 2D harmonic oscillator basis in the transverse directions. In previous work [3] this approach has been applied to evaluate the anomalous magnetic moment of electrons which are confined in an external trap with an extrapolation to the zero trap limit. In this work we extend and improve this approach in several aspects including the direct evaluation of a free electron system. This article is organized as follows: In Sec. 2 we discuss the key extensions and improvements made in this work over Ref [3]; in Sec. 3 we present the numerical results for the electron anomalous magnetic moment evaluated in different harmonic oscillator bases and compare to the perturbation theory result. Finally we conclude and give an outline for future works in Sec. 4.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Formation of 238 U 16 O and 238 U 18 O observed by time-resolved emission spectroscopy subsequent to laser ablation

Here, we have measured vibronic emission spectra of an oxide of uranium formed after laser ablation of the metal in gaseous oxygen. Specifically, we have measured the time-dependent relative intensity of a band located at approximately 593.6 nm in 16 O 2 . This band grew in intensity relative to neighboring atomic features as a function time in an oxygen environment but was relatively invariant with time in argon. In addition, we have measured the spectral shift of this band in an 18 O 2 atmosphere. Based on this shift, and by comparison with earlier results obtained from free-jet expansion and laser excitation, we can confirm that the oxide in question is UO, consistent with recent reports based on laser ablation in 16 O 2 only.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Time-resolved studies of particle effects in laser ablation inductively coupled plasma-mass spectrometry

Transient signal responses for ablated samples as a function of particle size and laser parameters are characterized. Data are acquired with time resolution of 5 or 6 ms per data point. Large positive spikes in signal are observed and increase in both amplitude and frequency with increasing particle size. Particle sizes are selected using a differential mobility analyzer. Spikes in the signal also increase with decreasing laser rastering rates. A comparison of lasers with pulse widths of 370 fs and 5 ns shows that shortening the pulse width significantly reduces the frequency and amplitude of positive spikes in signal. These large positive spikes are attributed to the vaporization, atomization, and ionization of individual large intact particles, which are considered to be a major cause of fractionation in laser ablation ICP-MS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation and Modeling of Time-Resolved X-Ray Detector for the Saturn Accelerator

In this work, we present the technology-aided computer design (TCAD) device simulation and modeling of a silicon p-i-n diode for detecting time-dependent X-ray radiation. We show that the simulated forward and reverse breakdown current–voltage characteristics agree well with the measured data under nonradiation environment by only calibrating carrier lifetimes for the forward bias case and avalanche model critical fields for the reverse bias condition. Using the calibrated parameters and other nominal material properties, we simulated the radiation responses of the p-i-n diode and compared with experimental data when the diode was exposed to X-ray radiation at Sandia’s Saturn facility and the Idaho State University (ISU) TriMeV facility. For Saturn’s Gaussian dose-rate pulses, we show three findings from TCAD simulations. First, the simulated photocurrents are in excellent agreement with the measured data for two dose-rate pulses with peak values of 1.16×10 10 and 1.88×10 10 rad(Si)/s. Second, the simulation results of high dose-rate pulses predict increased delayed photocurrents with longer time tails in the diode electrical responses due to excess carrier generation. Third, simulated peak values of diode radiation responses versus peak dose rates at different bias conditions provide useful guidance to determine the dose-rate range that the p-i-n diode can reliably detect in experiment. For TriMeV’s non-Gaussian dose-rate pulse, our simulated diode response is in decent agreement with the measured data without further calibration. We also studied the effects of device geometry, recombination process, and dose-rate enhancement via TCAD simulations to understand the higher measured response in the time after the peak dose-rate radiation for the p-i-n diode exposed to TriMeV irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Positron-emission tomography detector systems based on low-density liquid scintillators and precise time-resolving photodetectors

TOF-PET detector systems, and methods for imaging photon-emitting samples using the detector systems, are provided. The TOF-PET detector systems use large-area photodetectors with extremely high time-resolution and an approach to data collection and analysis that allows for the use of inexpensive low-density scintillator materials. The TOF-PET detector systems are characterized by their ability to identify, on a statistical basis, the transverse and depth location of the first of the series of energy deposition events that are generated when a gamma photon enters the low-density scintillator material.

Frisch, Henry J.↗

Highly time-resolved evaluation technique of instantaneous amplitude and phase difference using analytic signals for multi-channel diagnostics

A fluctuation analysis technique using analytic signals is proposed. Analytic signals are suitable to characterize a single mode with time-dependent amplitude and frequency, such as an MHD mode observed in fusion plasmas since the technique can evaluate amplitude and frequency at a specific moment without limitations of temporal and frequency resolutions, which is problematic in Fourier-based analyses. Moreover, a concept of instantaneous phase difference is newly introduced, and error of the evaluated phase difference and its error reduction techniques using conditional/ensemble averaging are discussed. These techniques are applied to experimental data of the beam emission spectroscopic measurement in the Heliotron J device, which demonstrates that the technique can describe nonlinear evolution of MHD instabilities. This technique is widely applicable to other diagnostics having necessity to evaluate phase difference.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved multi-omics reveals diverse metabolic strategies of Salmonella during diet-induced inflammation

With a rise in antibiotic resistance and chronic infection, the metabolic response of Salmonella enterica serovar Typhimurium to various dietary conditions over time remains an understudied avenue for novel, targeted therapeutics. Elucidating how enteric pathogens respond to dietary variation not only helps us decipher the metabolic strategies leveraged for expansion but also assists in proposing targets for therapeutic interventions. In this study, we use a multi-omics approach to identify the metabolic response of Salmonella enterica serovar Typhimurium in mice on both a fibrous diet and high-fat diet over time. When comparing Salmonella gene expression between diets, we found a preferential use of respiratory electron acceptors consistent with increased inflammation in high-fat diet mice. Looking at the high-fat diet over the course of infection, we noticed heterogeneity in samples based on Salmonella ribosomal activity, which is separated into three infection phases: early, peak, and late. We identified key respiratory, carbon, and pathogenesis gene expressions descriptive of each phase. Surprisingly, we identified genes associated with host cell entry expressed throughout infection, suggesting subpopulations of Salmonella or stress-induced dysregulation. Collectively, these results highlight not only the sensitivity of Salmonella to its environment but also identify phase-specific genes that may be used as therapeutic targets to reduce infection.

59 BASIC BIOLOGICAL SCIENCES↗

Electrical time resolved metrology of dust particles growing in low pressure cold plasmas

The electrical parameters of a capacitively coupled radiofrequency (CCRF) discharge change significantly when dust arises in the discharge. This work demonstrates the ability to follow in real time the evolution of the size and of the concentration of dust particles forming in a CCRF discharge from the variation of the electron density and of the self-bias voltage of the active electrode. According to experimental findings, it appears that the variation of this self-bias voltage depends on the surface of the dust particles. This trend is confirmed by an analytical modelling considering the low frequency behaviour of the phenomenon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Measurement of Z Opacity Sample Evolution near Solar Interior Conditions Using Time-Resolved Spectroscopy

Opacity model differences with Fe opacity measurements at high temperature (T>1⁢8⁢0 eV ) and high electron density (𝑛 𝑒 >3×10 22 cm −3 ) at nearly solar interior conditions have remained unresolved [Bailey et al., Nature 517, 56 (2015) and Nagayama et al., Phys. Rev. Lett. 122, 235001 (2019)]. Systematic errors from temporal gradients are one hypothesis for the discrepancy. Past data recorded on x-ray film provided spectral measurements over a time determined by the 2.8-ns backlighter duration. Here, we present the first measurements of opacity sample temporal evolution using novel hCMOS ultrafast x-ray camera technology. The measured conditions, measured backlighter time history, and modeled opacities are used to show that temporal gradients do not resolve the model-data discrepancy. The methods demonstrated provide potential advantages, including opacities at more extreme conditions, spectral line shift measurements, and improved measurements at other facilities.

atomic spectra↗

Time-resolved investigation of subnanosecond radiation from Al wire hybrid X pinches

K-shell x-ray spectra from Al wire hybrid X pinches have been studied using an x-ray streak camera with better than 0.1-ns time resolution together with a Focusing Spectrograph with Spatial Resolution (FSSR) spectrograph. High-intensity radiation with a continuumlike spectrum was observed in the subnanosecond initial phase of the x-ray pulse generated by the hybrid X pinch (HXP). Here, the absence of spectral lines in this phase and the extremely small x-ray source size indicates the importance of radiative processes in the final phase implosion dynamics. Plasma parameters in the following phases of the HXP were determined from analysis of the line intensities. Point-projection radiography together with a slit-step wedge camera and an FSSR spectrograph without time resolution were used to show the number of radiation sources, and to give information on the time-integrated photon energy spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-resolved orbital angular momentum spectroscopy

We introduce pump-probe magneto-orbital spectroscopy, wherein Laguerre-Gauss optical pump pulses impart orbital angular momentum to the electronic states of a material and subsequent dynamics are studied with 100 fs time resolution. The excitation uses vortex modes that distribute angular momentum over a macroscopic area determined by the spot size, and the optical probe studies the chiral imbalance of vortex modes reflected off the sample. First observations in bulk GaAs yield transients that evolve on time scales distinctly different from population and spin relaxation, as expected, but with surprisingly large lifetimes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗