Search NASA⌕ Search

SEARCH · Search NASA

Results for “weights”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*)

Purpose: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). Methods: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1–5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen’s κ test. Results: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). Conclusions: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PET/CT in brachytherapy early response evaluation of pancreatic ductal adenocarcinoma xenografts: comparison with apparent diffusion coefficient from diffusion-weighted MR imaging

Objective: To evaluate the feasibility of using PET/CT and diffusion-weighted magnetic resonance imaging (DW-MRI) to monitor the early response of pancreatic ductal adenocarcinoma (PDAC) xenografts to brachytherapy, and to determine whether maximum standardized uptake value (SUVmax) correlate with apparent diffusion coefficient (ADC). Materials and Methods: SW1990 human PDAC were subcutaneously implanted in 20 nude mice. They were randomly divided into 125-Iodine ({sup 125}I) seeds and blank seeds group. PET/CT and DW-MRI were performed at pretreatment and 5 days after therapy. SUVmax and ADC values were calculated, respectively. The correlation between SUVmax and ADC values was analyzed by the Pearson correlation test. Results: The SUVmax were significantly decreased between pretreatment and 5 days after {sup 125}I seeds treatment (p < 0.001) and between two groups (p < 0.001). And the ADC values were significantly increased between pretreatment and 5 days after {sup 125}I seeds treatment (p < 0.001) and between two groups (p < 0.001). While in the bank seeds group, there were no significantly difference between pretreatment and after treatment in SUVmax and ADC values (p = 0.057; p = 0.397). SUVmax and ADC correlated significantly and negatively before treatment in both groups (r = − 0.964, R{sup 2} = 0.929, p < 0.001; r = − 0.917, R{sup 2} = 0.841, p < 0.001) and after treatment in the blank seeds group (r = − 0.944, R{sup 2} = 0.891, p < 0.001). But after {sup 125}I seeds treatment there was no significant correlation between SUVmax and ADC (r = − 0.388, R{sup 2} = 0.151, p = 0.268). Conclusion: The PET/CT and DW-MRI are capable of monitoring the early response of PDAC xenografts to brachytherapy. The significantly inverse correlation between pretreatment SUVmax and ADC suggests that PET/CT and DW-MRI might play complementary roles for therapy assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffusion-weighted imaging as a part of PET/MR for small lesion detection in patients with primary abdominal and pelvic cancer, with or without TOF reconstruction technique

Objectives: To investigate the value of diffusion-weighted imaging (DWI) in detection of small lesions (≤ 10 mm) in patients with primary abdominal and pelvic cancer in hybrid PET/MR with or without time-of-flight (TOF) technique. Materials and methods: Twenty patients (11 females and 9 males, mean age 67.23 ± 12.90 years) with histologically confirmed primary abdominal and pelvic cancer underwent hybrid PET/MR examination. A total of 64 small lesions were included in this study, which were divided into two groups (≤ 10 mm and 10–30 mm). Visual scores of small lesion detection ability were rated by five-point ordinal scale. The visual scores and detectability of small lesions on TOF PET image, noTOF PET image, and DWI sequences of hybrid PET/MR examination with or without TOF technique were analyzed. Logistic regression model was established for analysis in the value of DWI in hybrid PET/MR examination with or without TOF technique in detection of the small lesions between two groups. Results: The visual evaluation revealed the small lesion (≤ 10 mm) visual scores of DWI (mean ± SD: 4.23 ± 1.41), TOF PET image (mean ± SD: 4.14 ± 0.89), and noTOF PET image (mean ± SD: 2.68 ± 1.13);.and the visual scores of small lesions (10–30 mm) on DWI (mean ± SD: 4.98 ± 0.15), TOF PET image (mean ± SD: 4.57 ± 0.59), and noTOF PET image (mean ± SD: 3.98 ± 1.05). The visual scores of all small lesions on DWI were higher than that on TOF PET data and noTOF PET data in both two groups (**P < 0.01). The missed diagnosis rates of small FDG avid lesions (≤ 10 mm) of DWI and noTOF PET image were 9.1% and 9.1%, respectively. However, the TOF PET-based clinical diagnosis detected all small lesions (≤ 30 mm). DWI was of great importance in detection of small lesions (≤ 10 mm) in the absence of TOF technique in PET/MR examination (**P < 0.01). DWI’s effect on detection of small lesions(10-30 mm) has shown no difference between PET/MR examinations with TOF and without TOF techniques (P > 0.05). Conclusion: DWI has significant value in the detection of small lesions (≤ 10 mm) in hybrid PET/MR examination without TOF technique for patients with primary abdominal and pelvic cancer. However, it had less detection benefits in the small lesions (≤ 10 mm) in hybrid PET/MR examination with TOF PET image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy, criteria, and clinical significance of visual assessment on diffusion-weighted imaging and apparent diffusion coefficient quantification for diagnosing acute appendicitis

Purpose: To assess the accuracy, criteria, and clinical significance of diffusion-weighted imaging (DWI) signal intensity and apparent diffusion coefficient (ADC) quantification for diagnosing acute appendicitis. Methods: Fifty-one patients with right lower abdominal pain [uncomplicated appendicitis (n = 25), complicated appendicitis (n = 10), and non-appendicitis (n = 16)] who underwent MR examination were enrolled in this retrospective study. Two radiologists independently measured appendiceal diameter and wall thickness. They assessed whether a wall defect, an abscess, extraluminal air, or an appendicolith was present on axial T2WI; evaluated intensity on DWI using a 5-point scale; and determined the ADC values of the appendix and peri-appendiceal tissue. Statistical analysis was performed to assess imaging findings for the diagnosis of appendicitis and complicated appendicitis. Cut-off values were determined using receiver operating characteristic analysis. Results: For diagnosing acute appendicitis, the accuracy improved from 78.4% using only T2WI to 86.3% using combined T2WI and DWI for reader 1 and from 82.4 to 86.3% for reader 2. For the appendix, the cut-off ADC values that diagnosed appendicitis were 1.41 × 10{sup −3} and 1.26 × 10{sup −3} mm{sup 2}/s with accuracies of 78.4% and 76.5%, respectively. For the peri-appendiceal tissue, these values of 1.03 × 10{sup −3} and 0.91 × 10{sup −3} mm{sup 2}/s differentiated between uncomplicated and complicated appendicitis with an accuracy of 97.1%. Conclusions: Combined DWI and T2WI provided high accuracy for diagnosing appendicitis. The inflamed appendix had lower ADC value than the normal appendix. The peri-appendiceal tissue presenting low ADC value was a notable finding of complicated appendicitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clear Depiction of Inflammatory Abdominal Aortic Aneurysm with Diffusion-Weighted Magnetic Resonance Imaging

We report the case of an inflammatory abdominal aortic aneurysm incidentally detected clearly with diffusion-weighted magnetic resonance imaging (DW-MRI) during the examination of a patient with myelofibrosis with myeloid metaplasia that later converted to acute myeloid leukemia. DW-MRI revealed a hyperintense halo surrounding the abdominal aorta with aneurysmatic dilatation, establishing the diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Detection of Therapeutic Response to Hepatic Arterial Infusion Chemotherapy of Liver Metastases from Colorectal Cancer Using Diffusion-Weighted MR Imaging

The purpose of this study was to investigate whether diffusion-weighted magnetic resonance imaging (DWI) is useful for early detection of the response of hepatic colorectal metastases to hepatic arterial infusion chemotherapy (HAIC) with 5-fluorouracil (5-FU). The subjects were 12 patients with hepatic colorectal metastases. The indwelling catheter for HAIC was placed in the hepatic artery, and 1000 mg/m{sup 2} 5-FU was given repeatedly once a week. DWI was performed before and 9 days after HAIC. The minimum and mean apparent diffusion coefficient (ADC) values (minADC and meanADC) were measured. The relative change in ADC values (%ADC) and the relative change in tumor size on follow-up CT after 3 months (reduction ratio) were determined. Liver metastases were divided into two groups, responder and nonresponder. The correlation between %ADC and reduction ratio was determined, and %ADC was compared between the two groups. Eleven patients successfully completed HAIC over the 3-month period; 48 metastatic lesions were evaluated. Positive correlations were observed for relative change between %minADC and reduction ratio (r = 0.709) and between %meanADC and reduction ratio (r = 0.536). Both %minADC and %meanADC were significantly greater in the responder group than in the nonresponder group. With the threshold determined as < 3.5%, the receiver-operating curve analysis showed higher sensitivity and specificity values for %minADC (100% and 92.6%, respectively) than for %meanADC (66.7% and 74.1%, respectively). In conclusion, the relative change in minimum ADC values on DWI may be useful for early detection of the response of liver metastases to HAIC with 5-FU.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffusion-Weighted MRI Assessment of Adjacent Disc Degeneration After Thoracolumbar Vertebral Fractures

ObjectiveThe purpose of this study was to assess, by the mean apparent diffusion coefficient (ADC), if a relationship exists between disc ADC and MR findings of adjacent disc degeneration after thoracolumbar fractures treated by anatomic reduction using vertebral augmentation (VAP).Materials and MethodsTwenty non-consecutive patients (mean age 50.7 years; range 45–56) treated because of vertebral fractures, were included in this study. There were 10 A3.1 and 10 A1.2 fractures (AO classification). Surgical treatment using VAP was applied in 14 cases, and conservative in 6 patients. MRI T2-weighted images and mapping of apparent diffusion coefficient (ADC) of the intervertebral disc adjacent to the fractured segment were performed after a mean follow-up of 32 months. A total of 60 discs, 3 per patient, were analysed: infra-adjacent, supra-adjacent and a control disc one level above the supra-adjacent.ResultsNo differences between patients surgically treated and those following a conservative protocol regarding the average ADC values obtained in the 20 control discs analysed were found. Considering all discs, average ADC in the supra-adjacent level was lower than in the infra-adjacent (1.35 ± 0.12 vs. 1.53 ± 0.06; p < 0.001). Average ADC values of the discs used as a control were similar to those of the infra-adjacent level (1.54 ± 0.06). Compared to surgically treated patients, discs at the supra-adjacent fracture level showed statistically significant lower values in cases treated conservatively (p < 0.001). The variation in the delay of surgery had no influence on the average values of ADC at any of the measured levels.ConclusionsADC measurements of the supra-adjacent discs after a mean follow-up of 32 months following thoracolumbar fractures, showed that restoration of the vertebral collapse by minimally invasive VAP prevents posttraumatic disc degeneration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Embolization After Carotid Artery Stenting with Mesh-Covered Stent: Role of Diffusion-Weighted Magnetic Resonance Imaging as Pre-procedural Predictor and Discriminant Between Intra- and Post-procedural Events

Objectives: To evaluate the incidence and the time of onset of early micro-embolism after CAS (carotid artery stenting) with two different mesh-covered stents and to assess the role of DW-MRI (Diffusion-weighted magnetic resonance imaging) in their prediction. Methods: Single-institution prospective study including 50 patients (33 male, median age 74 years) who underwent CAS with Roadsaver{sup ®} or CGuard™. All patients with primary stenosis (37/50, 74%) had carotid plaque DW-MRI pre-procedure, with both qualitative evaluation of the hyperintensity and ADC (apparent diffusion coefficient) measurement of the plaque. All patients had brain DW-MRI pre-procedure, at 1 h, 24 h and 30 days post-procedure to evaluate the appearance of hyperintense lesions over time. Imaging analysis was performed in a double-blinded fashion by two radiologists. Results: There were no statistically significant differences between the two stents both in the incidence at 1 h (P = 0.23) and 24 h (P = 0.36) and in the volume of new DWI hyperintense brain lesions at 24 h (P = 0.27). Thirty-four new asymptomatic lesions in 19 patients (38%) were reported: 4 (11.8%) at 1 h, 30 (88.2%) at 24 h. The 30-day DWI-MR showed complete resolution of all lesions and no evidence of new lesion. The incidence of new lesions at 24 h resulted significantly higher in patients with DWI hyperintense carotid plaques (12/16, 75% vs. 0/21, 0%, P < 0.0001). This result was paralleled by the difference in ADC value (0.83 ± 0.21 vs. 1.42 ± 0.52). Conclusion: The majority of early asymptomatic brain lesion occurred during the first 24 h after CAS. Pre-procedure high DWI signal of the plaque was associated with an increased incidence of post-procedure microembolizations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Progress toward light weight high angular resolution multilayer coated optics

We have been working on 3 separate projects that together will give us the ability to make 1 arc second, light weight Wolter I optics that work above 40 keV. The three separate tasks are: (a) plasma spraying of metal-coated micro-balloons; (b) coating of the inside of Wolter I mirrors, (c) actuator designs for improving figure quality. We give a progress report on our work on all three areas. In summary, for future space missions it will be desirable for them to be affordable by reducing mass, keeping the focal length manageable, and yet having high figure quality. The avenues we have described above are straight forward paths to achieving this goal, but a great deal of work needs to be done to take us from the concept stage to a functional system.

36 MATERIALS SCIENCE↗

CoFe{sub 2}O{sub 4} Nano-particles for Radical Oxidative Degradation of High Molecular Weight Polybutadiene

Polymer waste production increased dramatically in the last decades, and has reached to 380 million tons (Mt.) in 2015. Due to their long-term stability, these materials impose a serious environmental challenge. Currently, recycling of polymer waste focuses on re-use of actual products, mechanical processing, chemical recycling, and bio-degradation into environmentally friendly materials. In our previous work, we proposed a new approach for radical-initiated oxidative degradation of polymers using cobalt ferrite (CoFe{sub 2}O{sub 4}) nanoparticles. In our current work, we focus on the use of CoFe{sub 2}O{sub 4} nanoparticles as catalysts for radical degradation of high molecular weight polybutadiene. Cobalt ferrite nanoparticles were embedded into the polybutadiene polymeric matrix, with the aim of studying degradation in polymeric products that can be manufactured with catalytic nanoparticles. The polymer degradation process was characterized using gel permeation and size exclusion chromatography measurements, thermogravimetric analysis, FTIR, NMR, and mass spectroscopy. Based on the results from these diverse measurements, we propose a mechanism for the degradation process. Overall, our results show that the radical processes within the polybutadiene polymer lead to two parallel processes: polymer crosslinking and polymer scission. Moreover, we show that the ratio between crosslinking and degradation can be controlled by the reaction duration and catalyst concentration.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Mixed Dirichlet–Steklov Problem for the Biharmonic Equation in Weighted Spaces

We address the uniqueness of weak solutions of the mixed Dirichlet–Steklov problem for the biharmonic equation in the exterior of a compact set in the class of functions having a finite Dirichlet integral with the weight |x|{sup a}. Depending on the parameter a, we establish some uniqueness theorems and obtain precise formulas for the dimension of the space of solutions.

97 MATHEMATICS AND COMPUTING↗

Effect of Carbon Fiber Surface Modification on the Mechanical Properties of Carbon-Fiber-Reinforced Ultrahigh-Molecular-Weight Polyethylene Composite

In this paper, the surface properties and morphologies of the concentrated nitric acid (HNO{sub 3})-modified carbon fiber (CF) were characterized by XPS, SEM, and contact angle goniometer, respectively. The results showed that both the oxygen-containing functional groups content and the surface roughness of concentrated HNO{sub 3}-modified CF significantly increased. The contact angle of concentrated HNO{sub 3}-modified CF was obviously lower than that of unmodified CF. Studies on the mechanical properties of carbon-fiber-reinforced ultrahigh-molecular-weight polyethylene (CF/UHMWPE) composite revealed that the stress–strain behavior gradually changed from nonlinear to linear relationship with the rise of CF content in UHMWPE matrix. Both the tensile strength and modulus increased with the rise of CF content. Conversely, as the CF content in UHMWPE matrix is increasing, the flexural strength and modulus increased first and then decreased. The flexural strength and modulus of CF/UHMWPE composite with 30 wt.% CF content reached the maximum value of 157.61 MPa and 9.82 GPa, respectively. Moreover, the CF surface modification and CF content have a synergistic effect on the tensile and flexural mechanical properties of the CF/UHMWPE composite. The influence of CF modification on the tensile and flexural mechanical properties of the composite became more and more obvious with the rise of CF content.

36 MATERIALS SCIENCE↗

A Weighting Grade-Based Optimization Method for Determining Refill Friction Stir Spot Welding Process Parameters

The welding process used in fabricating thin-walled structures by refill friction stir spot welding (RFSSW) should be characterized by a high strength of welds and high process repeatability which is demonstrated by a small dispersion of the load capacity of the joints. The present work is designed to optimize RFSSW process parameters for 7075-T6 Alclad aluminum alloy sheets used to fabricate aircraft structures. The optimization was performed by scalarization of the objective function using the weighting grades method. The study considers the effect of process parameters, i.e., tool plunge depth, duration of welding, tool rotational speed, on the tensile/shear strength of the joints, and dispersion of the load capacity. It was found that it was possible to choose the optimal welding parameters taking into account maximization of the load capacity and minimization of the dispersion of the joint strength via a best compromise between the tool rotational speed ensuring adequate plasticization of the base material and the duration of welding ensuring that a fine-grained joint microstructure is obtained.

36 MATERIALS SCIENCE↗

Some new preconditioned generalized AOR methods for solving weighted linear least squares problems

In this paper, we propose some new preconditioned GAOR methods for solving weighted linear least squares problems and discuss their comparison results. Comparison results show that the convergence rates of the new preconditioned GAOR methods are better than those of the preconditioned GAOR methods presented by Shen et al. (Appl Math Mech Engl Ed 33(3):375–384, 2012) and Wang et al. (J Appl Math, doi: 10.1155/2012/563586 , 2012) whenever these methods are convergent. Finally, numerical experiments are provided to confirm the theoretical results obtained in this paper.

97 MATHEMATICS AND COMPUTING↗

Weighted oscillator strengths for the Xe IV spectrum

The weighted oscillator strengths, gf, of 769 previously reported classified spectral lines, and 49 new observed and also classified lines belonging to the 5s{sup 2}5p{sup 3}, 5s5p{sup 4}, 5s{sup 2}5p{sup 2}(6p + 4f), and 5s{sup 2}5p{sup 2}(5d + 6s) transitions array in Xe IV, were determined through a multiconfigurational Hartree-Fock relativistic approach. In this calculation, the electrostatic parameters were optimized by a least-square procedure in order to improve the adjustment to experimental energy levels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiconfiguration Dirac–Hartree–Fock energy levels, weighted oscillator strengths, transitions probabilities, lifetimes, hyperfine constants, Landé g-factors and isotope shifts of Xe LIII

Energy levels, weighted oscillator strengths and transition probabilities, lifetimes, hyperfine interaction constants, Landé g{sub J} factors and isotope shifts are calculated for all levels of 1s{sup 2} and 1snl (n=2−7) configurations of He-like xenon ion (Xe LIII). Multiconfigurational Dirac–Hartree–Fock (MCDHF) method is adopted for calculating these spectroscopic data. Comparisons are made with similar data obtained with FAC (Flexible Atomic Code) to assess the accuracy of the results. Transition probabilities are reported for all E1, E2, M1 and M2 transitions from the ground level. Breit interactions and quantum electrodynamics effects are estimated in extensive Relativistic Configuration Interaction (RCI) calculations. Comparisons were made with the available data in the literature and good agreement was found which confirms the reliability of our results. The accuracy of the present calculations is high enough to facilitate identification of many observed spectral lines. Almost all atomic data of He-like xenon ion presented in this paper are calculated for the first time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy levels, weighted oscillator strengths, transition rates, lifetimes, hyperfine structures and isotope shifts of He-like-Sn deduced from the relativistic multiconfiguration Dirac–Hartree–Fock and second-order many-body perturbation theory calculations

We disclose relativistic multiconfiguration Dirac–Hartree–Fock (MCDHF) spectrum calculations for SnXLIX. Energy levels, weighted oscillator strengths, isotope shifts, hyperfine structure and Landé g{sub J} factors are calculated for 127 odd- and even-parity states as well as lifetimes and transition rates between these states. To scrutinize the accuracy of our results, we have implemented parallel calculations using a Flexible Atomic Code (FAC) by introducing the Second-Order Many-Body Perturbation Theory (MBPT) method. Additionally, the Breit interaction and leading quantum electrodynamic effects (QED) are included as perturbations in extensive relativistic configuration interaction (RCI) calculations. We signal that, our calculations for SnXLIX are made for the first time and they provide to date the most accurate and complete atomic data related to this ion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗