Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Boundary characterization using 3D mapping of geometrically necessary dislocations in AM Ta microstructure

Additive manufacturing (AM) of high strength metallic materials produces microstructures and defects that deviate substantially from those created through conventional manufacturing methods. It has recently been demonstrated that with application of extreme energy densities, a high-temperature refractory metal, tantalum (Ta), can be printed to a fully dense state with exceptionally low porosity. Here we employ a combination of three-dimensional electron backscattered diffraction (EBSD) TriBeam technology and crystallographic geometrically necessary dislocation (GND) theory to characterize the microstructure and defect boundaries of this unusual AM product. Two-dimensional (2D) EBSD and these three-dimensional (3D) measurements indicate that the microstructure of AM Ta is highly oriented <111> along the build direction, yet at the same time contains large crystallographic orientation gradients that span mm’s across the build. Crystallographic GND density analysis of the 3D microstructure reveals that highly misoriented subboundaries exist within this strongly textured microstructure that have large dislocation densities of 1×10 16 m –2 , just as large as those comprising the high-angle grain boundaries (HAGBs) in the same material. The 3D crystallographic GND density mapping reveals these subboundaries are part of a complex, finely spaced network that extends throughout the entire microstructure. Here, the orientation of these boundaries can be related to the scan strategy used during printing. TEM measurements corroborate an extremely high dislocation density at the microscale and indicate a cell-like dislocation network structure existing in the AM Ta at the sub-μm scale.

36 MATERIALS SCIENCE↗

X-ray Laue Diffraction Microscopy in 3D at the Advanced Photon Source

Studies of materials on mesoscopic length-scales require a penetrating structural probe with submicron point-to-point spatial resolution. The principle research activities at beamline 34-ID-E of the Advanced Photon Source (APS) involve development of exciting new micro-/nano-diffraction techniques for characterization and microscopy in support of both applied engineering and fundamental materials research. Taking advantage of the high brightness of the source, advanced focusing mirrors, a novel depth profiling technique, and high-speed area detectors, three-dimensional scanning Laue diffraction microscopy provides detailed local structural information of crystalline materials, such as crystallographic orientation, orientation gradients, and strain tensors. It is general and applicable to single-crystal, polycrystalline, composite, deformed, and functionally graded materials. Applications include 3D diffraction investigations for a diverse and growing user community with interests in materials deformation, electro-migration, recrystallization, fatigue, solid-solution precipitation, high-pressure environments, and condensed matter physics.

43 PARTICLE ACCELERATORS↗

Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment

Purpose: A C-arm CT system has been shown to be capable of scanning a single cadaver leg under loaded conditions by virtue of its highly flexible acquisition trajectories. In Part I of this study, using the 4D XCAT-based numerical simulation, the authors predicted that the involuntary motion in the lower body of subjects in weight-bearing positions would seriously degrade image quality and the authors suggested three motion compensation methods by which the reconstructions could be corrected to provide diagnostic image quality. Here, the authors demonstrate that a flat-panel angiography system is appropriate for scanning both legs of subjectsin vivo under weight-bearing conditions and further evaluate the three motion-correction algorithms using in vivo data. Methods: The geometry of a C-arm CT system for a horizontal scan trajectory was calibrated using the PDS-2 phantom. The authors acquired images of two healthy volunteers while lying supine on a table, standing, and squatting at several knee flexion angles. In order to identify the involuntary motion of the lower body, nine 1-mm-diameter tantalum fiducial markers were attached around the knee. The static mean marker position in 3D, a reference for motion compensation, was estimated by back-projecting detected markers in multiple projections using calibrated projection matrices and identifying the intersection points in 3D of the back-projected rays. Motion was corrected using three different methods (described in detail previously): (1) 2D projection shifting, (2) 2D deformable projection warping, and (3) 3D rigid body warping. For quantitative image quality analysis, SSIM indices for the three methods were compared using the supine data as a ground truth. Results: A 2D Euclidean distance-based metric of subjects’ motion ranged from 0.85 mm (±0.49 mm) to 3.82 mm (±2.91 mm) (corresponding to 2.76 to 12.41 pixels) resulting in severe motion artifacts in 3D reconstructions. Shifting in 2D, 2D warping, and 3D warping improved the SSIM in the central slice by 20.22%, 16.83%, and 25.77% in the data with the largest motion among the five datasets (SCAN5); improvement in off-center slices was 18.94%, 29.14%, and 36.08%, respectively. Conclusions: The authors showed that C-arm CT control can be implemented for nonstandard horizontal trajectories which enabled us to scan and successfully reconstruct both legs of volunteers in weight-bearing positions. As predicted using theoretical models, the proposed motion correction methods improved image quality by reducing motion artifacts in reconstructions; 3D warping performed better than the 2D methods, especially in off-center slices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-A-12A-07: CT-Based Biomarkers to Characterize Lung Lesion: Effects of CT Dose, Slice Thickness and Reconstruction Algorithm Based Upon a Phantom Study

Purpose: Radiogenomics promises the ability to study cancer tumor genotype from the phenotype obtained through radiographic imaging. However, little attention has been paid to the sensitivity of image features, the image-based biomarkers, to imaging acquisition techniques. This study explores the impact of CT dose, slice thickness and reconstruction algorithm on measuring image features using a thorax phantom. Methods: Twentyfour phantom lesions of known volume (1 and 2mm), shape (spherical, elliptical, lobular and spicular) and density (-630, -10 and +100 HU) were scanned on a GE VCT at four doses (25, 50, 100, and 200 mAs). For each scan, six image series were reconstructed at three slice thicknesses of 5, 2.5 and 1.25mm with continuous intervals, using the lung and standard reconstruction algorithms. The lesions were segmented with an in-house 3D algorithm. Fifty (50) image features representing lesion size, shape, edge, and density distribution/texture were computed. Regression method was employed to analyze the effect of CT dose, slice of thickness and reconstruction algorithm on these features adjusting 3 confounding factors (size, density and shape of phantom lesions). Results: The coefficients of CT dose, slice thickness and reconstruction algorithm are presented in Table 1 in the supplementary material. No significant difference was found between the image features calculated on low dose CT scans (25mAs and 50mAs). About 50% texture features were found statistically different between low doses and high doses (100 and 200mAs). Significant differences were found for almost all features when calculated on 1.25mm, 2.5mm, and 5mm slice thickness images. Reconstruction algorithms significantly affected all density-based image features, but not morphological features. Conclusions: There is a great need to standardize the CT imaging protocols for radiogenomics study because CT dose, slice thickness and reconstruction algorithm impact quantitative image features to various degrees as our study has shown.

60 APPLIED LIFE SCIENCES↗

Individualized Margins in 3D Conformal Radiotherapy Planning for Lung Cancer: Analysis of Physiological Movements and Their Dosimetric Impacts

In conformal radiotherapy planning for lung cancer, respiratory movements are not taken into account when a single computed tomography (CT) scan is performed. This study examines tumor movements to design individualized margins to account for these movements and evaluates their dosimetric impacts on planning volume. Fifteen patients undergoing CT-based planning for radical radiotherapy for localized lung cancer formed the study cohort. A reference plan was constructed based on reference gross, clinical, and planning target volumes (rGTV, rCTV, and rPTV, respectively). The reference plans were compared with individualized plans using individualized margins obtained by using 5 serial CT scans to generate individualized target volumes (iGTV, iCTV, and iPTV). Three-dimensional conformal radiation therapy was used for plan generation using 6- and 23-MV photon beams. Ten plans for each patient were generated and dose-volume histograms (DVHs) were calculated. Comparisons of volumetric and dosimetric parameters were performed using paired Student t-tests. Relative to the rGTV, the total volume occupied by the superimposed GTVs increased progressively with each additional CT scans. With the use of all 5 scans, the average increase in GTV was 52.1%. For the plans with closest dosimetric coverage, target volume was smaller (iPTV/rPTV ratio 0.808) but lung irradiation was only slightly decreased. Reduction in the proportion of lung tissue that received 20 Gy or more outside the PTV (V20) was observed both for 6-MV plans (-0.73%) and 23-MV plans (-0.65%), with p = 0.02 and p = 0.04, respectively. In conformal RT planning for the treatment of lung cancer, the use of serial CT scans to evaluate respiratory motion and to generate individualized margins to account for these motions produced only a limited lung sparing advantage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-QI-21: Iodinated Contrast Agent Time Course In Human Brain Metastasis: A Study For Stereotactic Synchrotron Radiotherapy Clinical Trials

Purpose: Synchrotron stereotactic radiotherapy (SSRT) is an innovative treatment combining the selective accumulation of heavy elements in tumors with stereotactic irradiations using monochromatic medium energy x-rays from a synchrotron source. Phase I/II clinical trials on brain metastasis are underway using venous infusion of iodinated contrast agents. The radiation dose enhancement depends on the amount of iodine in the tumor and its time course. In the present study, the reproducibility of iodine concentrations between the CT planning scan day (Day 0) and the treatment day (Day 10) was assessed in order to predict dose errors. Methods: For each of days 0 and 10, three patients received a biphasic intravenous injection of iodinated contrast agent (40 ml, 4 ml/s, followed by 160 ml, 0.5 ml/s) in order to ensure stable intra-tumoral amounts of iodine during the treatment. Two volumetric CT scans (before and after iodine injection) and a multi-slice dynamic CT of the brain were performed using conventional radiotherapy CT (Day 0) or quantitative synchrotron radiation CT (Day 10). A 3D rigid registration was processed between images. The absolute and relative differences of absolute iodine concentrations and their corresponding dose errors were evaluated in the GTV and PTV used for treatment planning. Results: The differences in iodine concentrations remained within the standard deviation limits. The 3D absolute differences followed a normal distribution centered at zero mg/ml with a variance (∼1 mg/ml) which is related to the image noise. Conclusion: The results suggest that dose errors depend only on the image noise. This study shows that stable amounts of iodine are achievable in brain metastasis for SSRT treatment in a 10 days interval.

60 APPLIED LIFE SCIENCES↗

SU-F-T-565: Assessment of Dosimetric Accuracy for a 3D Gel-Based Dosimetry Service

Purpose: To assess the 3D dosimetric accuracy when using a mail-in service for square and stereotactic fields in a clinical environment. Methods: The 3D dosimetry mail-in service (3DDaaS), offered by Modus QA (London, ON), was used to measure dose distributions from a 6 MV beam of a Varian Clinac. Plastic jars filled with radiosensitive ClearView™ gel were received, CT scanned (for registration and density information), irradiated, and then mailed back to the manufacturer for optical CT readout. Three square field irradiations (2×2, 4×4, and 10×10 cm{sup 2}) were performed with jars immobilized in a water tank, and a composite small-field stereotactic delivery was performed using an in-air holder. Dosimetric properties of the gel were quantified within the 25–50 Gy dose range using 3D optical attenuation (OA) distributions provided by the manufacturer. OA was normalized to 100% at the position of isocenter, which received 40Gy. Percentage depth dose, profiles, and 3D gamma distributions (3%/1mm criteria) were calculated to quantify feasibility for relative dosimetry. Results: Mean CT-measured density in the central (3×3×3) cm{sup 3} gel region was 40 ± 3 HU, indicating good homogeneity and near-water-equivalence. Measured and calculated central axis doses agreed to within ±3% in the 25–50 Gy dose range. For the square field irradiations, dose profiles agreed to within 1mm. Gamma analysis of the composite irradiation yielded 99.8%, 91.4%, and 79.1% passing rates for regions receiving at least 10, 5, and 2 Gy, respectively, indicating feasibility for use in high-dose regions. Absolute response varied by up to 16% between jars, indicating limitations for absolute dosimetry under the mail-in conditions. Conclusion: 3DDaaS is a novel near-water-equivalent dosimetry system accurate to within 3% dose and 1mm 3D spatial resolution, and is straightforward to use in a clinical setting. Future investigations are warranted to improve dosimeter response in low-dose regions. The authors would like to thank ModusQA (London, ON) for providing the gels and optical readouts used this work. This work was partially funded by NIH P01CA059827.

60 APPLIED LIFE SCIENCES↗

Accelerated Partial Breast Irradiation: What is Dosimetric Effect of Advanced Technology Approaches?

Purpose: The present treatment planning study compared whole breast radiotherapy (WBRT) to accelerated partial breast irradiation (APBI) for different external beam techniques and geometries (e.g., free breathing [FB] and deep inspiration breath hold [DIBH]). Methods and Materials: After approval by our institutional review board, a treatment planning study was performed of 10 patients with left-sided Stage 0-I breast cancer enrolled in a Phase I-II study of APBI using intensity-modulated radiotherapy (IMRT). After lumpectomy, patients underwent planning computed tomography scans during FB and using an active breathing control device at DIBH. For the FB geometry, standard WBRT and three-dimensional conformal radiotherapy (3D-CRT) APBI plans were created. For the DIBH geometry with active breathing control, WBRT, 3D-CRT, and IMRT APBI plans were created. Results: All APBI techniques had excellent planning target volume coverage. The maximal planning target volume dose was reduced from 116% of the prescription dose to 108% with the IMRT(DIBH) APBI plan. The maximal heart dose was >30 Gy for the WBRT techniques, 8.2 Gy for 3D-CRT(FB), and <5.0 Gy for 3D-CRT(DIBH) and IMRT(DIBH) techniques. The mean left anterior descending artery dose was significantly reduced from 11.4 Gy with WBRT(FB) to 4.2 with WBRT(DIBH) and <2.0 Gy with all APBI techniques. Conclusion: Although planning target volume coverage was acceptable with all techniques, the plans using the DIBH geometry resulted in a marked reduction in the normal tissue dose compared with WBRT planned in the absence of cardiac blocking. Additional study is needed to determine whether these techniques result in clinical benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Realization of AlSb in the Double-Layer Honeycomb Structure: A Robust Class of Two-Dimensional Material

Exploring new two-dimensional (2D) van der Waals (vdW) systems is at the forefront of materials physics. Here, through molecular beam epitaxy on graphene-covered SiC(0001), we report successful growth of AlSb in the double-layer honeycomb (DLHC) structure, a 2D vdW material which has no direct analogue to its 3D bulk and is predicted kinetically stable when freestanding. The structural morphology and electronic structure of the experimental 2D AlSb are characterized with spectroscopic imaging scanning tunneling microscopy and cross-sectional imaging scanning transmission electron microscopy, which compare well to the proposed DLHC structure. The 2D AlSb exhibits a bandgap of 0.93 eV versus the predicted 1.06 eV, which is substantially smaller than the 1.6 eV of bulk. We also attempt the less-stable InSb DLHC structure; however, it grows into bulk islands instead. Here, the successful growth of a DLHC material here opens the door for the realization of a large family of novel 2D DLHC traditional semiconductors with unique excitonic, topological, and electronic properties.

36 MATERIALS SCIENCE↗

Spinel Ferrite Core–Shell Nanostructures by a Versatile Solvothermal Seed-Mediated Growth Approach and Study of Their Nanointerfaces

An easy, low-cost, repeatable seed-mediated growth approach in solvothermal condition has been proposed to synthesize bimagnetic spinel ferrite core–shell heterostructures in the 10–20 nm particle size range. Cobalt ferrite and manganese ferrite nanoparticles (CoFe 2 O 4 and MnFe 2 O 4 ) have been coated with isostructural spinel ferrites like maghemite/magnetite, MnFe 2 O 4 , and CoFe 2 O 4 with similar cell parameters to create different heterostructures. The conventional study of the structure, morphology, and composition has been combined with advanced techniques in order to achieve details on the interface at the nanoscale level. Clear evidence of the heterostructure formation have been obtained (i) indirectly by comparing the 57 Fe Mössbauer spectra of the core–shell samples and an ad hoc mechanical mixture and (ii) directly by mapping the nanoparticles’ chemical composition by electron energy loss spectroscopy (EELS) and energy-dispersive X-ray spectroscopy (EDX) in the scanning transmission electron microscopy mode (STEM). Additionally, chemical-sensitive electron tomography in STEM-EDX mode has been applied in order to obtain detailed 3D images with a sub-nanometer spatial resolution.

36 MATERIALS SCIENCE↗

Theory and application of the vector pair correlation function for real-space crystallographic analysis of order/disorder correlations from STEM images

Deviations of local structure and chemistry from the average crystalline unit cell are increasingly recognized to have a significant influence on the properties of many technologically important materials. Here, we present the vector pair correlation function (vPCF) as a new real-space crystallographic analysis method, which can be applied to atomic-resolution scanning transmission electron microscopy (STEM) images to quantify and analyze structural order/disorder correlations. Our STEM-based vPCFs have several advantages over radial PCFs and/or 3D pair distribution functions from x-ray total scattering: vPCFs explicitly retain crystallographic orientation information, are spatially resolved, can be applied directly on a sublattice basis, and are suitable for any material that can be imaged with STEM. To show the utility of our approach, we measure partial vPCFs in Ba 5 SmSn 3 Nb 7 O 30 (BSSN), a tetragonal tungsten bronze (TTB) structured complex oxide. Many TTBs are known to be classical or relaxor ferroelectrics, and these properties have been correlated with the presence of superlattice ordering. BSSN, specifically, exhibits relaxor behavior and an incommensurate structural modulation. From the vPCF data, we observe that, of the cation sites, only the Ba (A2) sublattice is structurally modulated. We then infer the local modulation vector and reveal a marked anisotropy in its correlation length. Finally, short-range correlated polar displacements on the B2 cation sites are observed. This work introduces the vPCF as a powerful real-space crystallography technique, which enables direct, robust quantification of short-to-long range order on a sublattice-specific basis and is applicable to a wide range of complex material types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Verification of a quasi-linear model for gyrokinetic turbulent transport

The verification and calibration of a new quasi-linear transport model with a large database of gyrokinetic turbulence simulations is presented in this paper. In a previous paper (Staebler et al 2020 Plasma Phys. Control. Fusion 63 015013), a model for the saturated spectrum of electric potential fluctuations was developed based on the properties of the non-linear 3D spectrum. In this paper, a modification to the overall multiplicative factor in this model is found to be necessary to improve the fit to scans of the temperature and density gradients. The error in the fit of the quasi-linear fluxes of electron and ion energy fluxes is significantly better than for previous saturation models. The spectral shift model for the impact of equilibrium E × B velocity shear (Staebler et al 2013 Phys. Rev. Lett. 110 055003) and the zonal flow mixing model for electron-scale turbulence (Staebler et al 2016 Phys. Plasmas 23 062518) are both revised to be compatible with this new model. Furthermore, the models for the loss of bounce averaging and electron collisions in the TGLF reduced linear equations (Staebler et al 2005 Phys. Plasmas 12 102508) are also changed to improve the linear eigenmodes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-209: Geometric Distortion at 3T in a Commercial 4D MRI-Compatible Phantom

Purpose: There are very few commercial 4D phantoms that are marketed as MRI compatible. We are evaluating one such commercial phantom, made to be used with an MRI-Linear accelerator. The focus of this work is to characterize the geometric distortions produced in this phantom at 3T using 3 clinical MR pulse sequences. Methods: The CIRS MRI-Linac Dynamic Phantom (CIRSTM) under investigation in this study consists of a softwaredriven moving tumour volume within a thorax phantom body and enables dose accumulation by placing a dosimeter within the tumour volume. Our initial investigation is to evaluate the phantom in static mode prior to examining its 4D capability. The water-filled thorax phantom was scanned using a wide-bore Philips 3T Achieva MRI scanner employing a Thoracic xl coil and clinical 2D T1W FFE, 2D T1W TSE and 3D T1W TFE pulse sequences. Each of the MR image sets was rigidly fused with a reference CT image of the phantom employing a rigid registration with 6 degrees of freedom. Geometric distortions between the MR and CT image sets were measured in 3 dimensions at selected points along the periphery of the distortion grid embedded within the phantom body (11.5, 7.5 and 3 cm laterally, ant/post and sup/inf of magnetic isocenter respectively). Results: The maximal measured geometric distortions between the MR and reference CT points of interest were 0.9, 1.8 and 1.3 mm in the lateral, anteriorposterior and cranio-caudal directions, respectively. For all 3 spatial dimensions, the maximal distortions occurred for the FFE pulse sequence. Maximal distortions for the 2D FFE, 2D TSE and 3D TFE sequences were 1, 0.7 and 1.8 mm, respectively. Conclusion: Our initial static investigation of this phantom shows minimal geometric distortions at 3T along the periphery of the embedded grid. CIRS has provided us with a phantom at no charge for evaluation at 3 Tesla.

60 APPLIED LIFE SCIENCES↗

SU-F-J-67: Dosimetric Changes During Radiotherapy in Lung Cancer Patients with Atelectasis

Purpose: Large geometric changes which occur during thoracic radiotherapy alter normal anatomy and target position and may induce clinically important dose changes. This study investigates variation of organ-at-risk (OAR) dose caused by atelectasis resolution during radiotherapy. Methods: 3D IMRT treatment plans were obtained for 14 non-small-cell lung cancer patients. Dose of the clinical plan was recalculated on a baseline scan in which lung was collapsed and on a midtreatment scan in which lung re-aeration had occurred. The changes in OAR doses were compared between the two time points. RTOG-0617 and inhouse dose-volume constraints were chosen for investigation and included spinal cord, esophagus, heart, and healthy lung. Results: 17 dose metrics were evaluated. The mean (SD) of change in mean lung dose, from baseline to mid-treatment (average taken across all patients), was 0.2 Gy (2.2 Gy) and ranged from −3.2 Gy to 6.0 Gy. 50% of patients experienced relative changes in mean lung dose of greater than 5% of baseline value. The mean (SD) of changes in heart V{sub 40}, V{sub 45}, and V{sup 60} were 3.2% (3.4%), 3.0% (2.9%), and 1.4% (2.1%), respectively, and were significant for the study cohort (Wilcoxon signed-rank test, p=0.0107 for V{sub 40}, p=0.0052 for V{sub 45}, and p= 0.0353 for V{sub 60}. Ranges in changes of Heart V{sub 40}, V{sub 45}, and V{sub 60} were −1.9% to 8.6%, −1.7% to 7.5%, and −2.1% to 4.5%, respectively. The mean (SD) of changes in Esophagus PRV Dmean and V{sub 60} were 0.3 Gy (3.3 Gy) and 0.8% (7.7%), respectively, and ranged from −4.8 Gy to 6.8 Gy for Dmean and −15.2% to 14.6% for V{sub 60}. Conclusion: Patients with atelectasis present at the start of radiotherapy experience significant increases in heart dose. Substantial increases in mean lung dose also occur in a subset of patients. This work supported by the National Cancer Institute of National Institutes of Health under Award Number R01CA166119. Disclosures: Phillips Medical systems (Hugo, Weiss), National Institutes of Health (Hugo, Weiss, Christensen), and Roger Koch (Christensen) support, UpToDate (Weiss) royalties, and Varian Medical Systems (Hugo, Weiss) license. No potential conflicts of interest.

60 APPLIED LIFE SCIENCES↗

Three dimensions, two microscopes, one code: Automatic differentiation for x-ray nanotomography beyond the depth of focus limit

Conventional tomographic reconstruction algorithms assume that one has obtained pure projection images, involving no within-specimen diffraction effects nor multiple scattering. Advances in x-ray nanotomography are leading toward the violation of these assumptions, by combining the high penetration power of x-rays, which enables thick specimens to be imaged, with improved spatial resolution that decreases the depth of focus of the imaging system. We describe a reconstruction method where multiple scattering and diffraction effects in thick samples are modeled by multislice propagation and the 3D object function is retrieved through iterative optimization. We show that the same proposed method works for both full-field microscopy and for coherent scanning techniques like ptychography. Our implementation uses the optimization toolbox and the automatic differentiation capability of the open-source deep learning package TensorFlow, demonstrating a straightforward way to solve optimization problems in computational imaging with flexibility and portability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3D Experimental Measurements of Evolution of Force Chains in Natural Silica Sand

The mechanisms of force transmission in granular materials is a classic physics problem that has been addressed since the 19th century, when Heinrich Rudolf Hertz investigated the interaction between two similar objects that were in contact under compression. However, the study of force transmission mechanisms in assemblies of more particles has proven to be a formidable problem due to the complex nature of granular materials. In recent years, synchrotron microcomputed tomography (SMT) and three-dimensional X-ray diffraction microscopy (3DXRD) have been employed to study the mechanics of granular materials experimentally. Combining SMT and 3DXRD offers unique three-dimensional (3D) experimental measurements of the internal structure, kinematics (such as rotation and translation), and lattice strains of individual sand particles. In this paper, in situ SMT and 3DXRD scans were acquired at multiple load steps for a specimen composed of 2,705 natural Ottawa sand particles that were subjected to one-dimensional (1D) confined compression. An algorithm was developed to combine SMT images and 3DXRD lattice strain measurements and used to characterize the constitutive behavior of sand particles. The results were used to identify the crystal structure and the evolution of the stresses and lattice strains of individual sand particles. Another algorithm was developed to characterize the force structures within the specimen. Force structures were identified, and their properties (such as length) and evolution through the experiment were examined. The contact number of particles is a particle-scale property that affects the mechanics of granular materials. The effect of the contact number of the sand particles on the onset and evolution of the force structures was also investigated and discussed.

3D x-ray diffraction microscopy↗

Electrical and Thermal Characterization of 3D Printed Thermoplastic Parts with Embedded Wires for High Current-Carrying Applications

Fabrication of parts exhibiting multi-functionality has recently been complemented by hybrid polymer extrusion additive manufacturing in combination with wire embedding technology. While much mechanical characterization has been performed on parts produced with fused deposition modeling, limited characterization has been performed when combined electrical and thermal loads are applied to 3D printed multi-material parts. As such, this work describes the design, fabrication, and testing of 3D printed thermoplastic coupons containing embedded copper wires that carried current. An automated fabrication process was used employing a hybrid additive manufacturing machine that dispensed polycarbonate thermoplastic and embedded bare copper wires. Testing included AC and DC hipot testing as well as thermal testing on as-fabricated and heat treated coupons to determine the effect of porosity in the substrate. The heat-treated parts contained reduced amounts of porosity, as corroborated through scanning electron microscopy, which led to 50 % increased breakdown strength and 30 to 40 % increased heat dissipation capabilities. The results of this research are describing a set of design protocol that can be used as a guideline for 3D printed embedded electronics to predict the electrical and thermal behavior.

Hipot testing↗