Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACTIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Effects of Angular Frequency During Clinorotation on Mesenchymal Stem Cell Morphology and Migration

Background/Objectives: Ground-based microgravity simulation can reproduce the apparent effects of weightlessness in spaceflight using clinostats that continuously reorient the gravity vector on a specimen, creating a time-averaged nullification of gravity. In this work, we investigated the effects of clinorotation speed on the morphology, cytoarchitecture, and migration behavior of human mesenchymal stem cells (hMSCs). Methods: We compared cell responses at clinorotation speeds of 0, 30, 60, and 75 rpm over 8 hours in a recently developed lab-on-chip-based clinostat system. Time lapse light microscopy was used to visualize changes in cell morphology during and after cessation of clinorotation. Cytoarchitecture was assessed by actin and vinculin staining, and chemotaxis was examined using time lapse light microscopy of cells in NGF (100 ng/ml) gradients. Results: Among clinorotated groups, cell area distributions indicated a greater inhibition of cell spreading with higher angular frequency (p is less than 0.005), though average cell area at 30 rpm after 8 hours became statistically similar to control (p = 0.794). Cells at 75rpm clinorotation remained viable and were able to re-spread after clinorotation. In chemotaxis chambers clinorotation did not alter migration patterns in elongated cells, but most clinorotated cells exhibited cell retraction, which strongly compromised motility.

microgravity↗

Mechanoregulation of Proliferation, Differentiation, Senescence and Survival of Bone Marrow Primary Osteoprecursor Cells

Cell and animal studies conducted onboard the International Space Station and during the Shuttle program have provided extensive data illustrating bone degenerative responses to mechanical unloading in microgravity. Specifically CDKN1a/p21, an inhibitory modulator of cell cycle progression, is upregulated in osteoprecursor cells of the femur during 15-day spaceflight, suggesting that microgravity can block stem cell-based tissue regenerative process at the level of progenitor proliferation and differentiation. To study a potential role for CDKN1a/p21 in regulating osteogenic mechanosensitivity, we cultured primary bone marrow osteoprogenitor cells from CDKN1a/p21-null (p21-null) and wildtype mice with and without mechanical stimulation, and compared their morphological, proliferative, and in-vitro mineralization responses. Structural cell alterations due to mechanical stimulation were assessed by florescence labeling of f-actin cytoskeleton and focal adhesions. Mechanical stimulation of p21-null cells resulted in more pronounced cytoskeletal alignment with the axis of stretch than for wildtype cells. In addition, p21-null cells subjected to stretch loading also formed significantly more focal adhesions than wildtype cells. Combined these findings suggest that p21-null cells are structurally more responsive to stretch stimulation than the wildtype cells. Because osteoprogenitor cells are well known to respond to mechanical stimulation with increased proliferation, we also tested this response in p21-null cells. Results from those experiments show the proliferative capacity of mechanically stimulated p21-null cells far exceeded that of wildtype controls. Specifically, cell counts from 14, and 21 days post mechanical stimulation, show that p21- null cells to have a 4-fold increase in proliferation compared to wildtype. When the p21-null cell differentiation response to mechanical stimulation was evaluated, the p21-null cultuers elicited more extensive mineralization at earlier assessed timepoints than control cultures. Specifically, Von Kossa staining for mineralized matrix showed that the p21-null cells produced more than twice the mineralized surface area of wildtype cells, and at an earlier 7-day time point in culture. Taken together these results suggest that CDKN1a/p21 normally plays a role in negatively regulating osteoprogenitor proliferation and differentiation responses to mechanostimulation in bone. Findings of CDKN1a/p21's increased expression during spaceflight in microgravity also suggest not only a potential molecular mechanism for arresting regenerative bone growth in space, but potentially also a reduced impact for bone-formation-promoting exercise mechanostimulation. The findings described here constitute a novel role for p21 as a regulator of tissue regeneration in response to mechanical load stimulation, and also suggest a new promising molecular target to promote regenerative health in disuse conditions.

gravity↗

Final Report - Hypergravity Effects on Chromatin Conformation and Nuclear Structure in Cultured Cells using High-throughput Sequencing

The conformation of the human genome is known to play an important role in transcriptional control of gene expression. Our aim is to assess whether exposure of cultured human cardiomyocytes to hypergravity can induce changes in chromatin organization as assayed by Hi-C proximity ligation technique. Hi-C is used to analyze chromatin interactions by using formaldehyde to crosslink regions of chromatin that are in close proximity. The DNA is then fragmented using a restriction enzyme and ligated under dilute conditions to favor intramolecular ligation of cross-linked fragments. Finally, the DNA is sequenced, allowing reconstruction of genomic structure. iCell cardiomyocyte cultures will be exposed to 40 g via an engineered device (incu-fuge) that allows for the chemical fixation of cells on a spinning centrifuge. Additionally, we plan on using fluorescence microscopy to analyze the nuclear and actin cytoskeletal conformation of cardiomyocytes post hypergravity exposure. We hypothesize that chromatin will rearrange in hypergravity conditions, both rapidly due to direct mechanical forces, as well as over longer time frames due to changes to structures necessary for transcriptional responses such as the de novo formation of promoter-enhancer loops. A negative result–no change between 1 g and hypergravity conditions–would nevertheless be an important data point in our understanding of the rheology of the nucleus, and how cells and cellular structures respond to different gravity fields. The cellular physiology of hypergravity has clinical relevance for spaceflight, and can further inform our understanding of microgravity physiology.

chromatin↗

Replicated mask surface roughness effects on EUV lithographic pattering and line edge roughness

To quantify the roughness contributions to speckle, a programmed roughness substrate was fabricated with a number of areas having different roughness magnitudes. The substrate was then multilayer coated. Atomic force microscopy (AFM) surface maps were collected before and after multilayer deposition. At-wavelength reflectance and total integrated scattering measurements were also completed. Angle resolved scattering based power spectral densities are directly compared to the AFM based power spectra. We show that AFM overpredicts the roughness in the picometer measurements range. The mask was then imaged at-wavelength for the direct characterization of the aerial image speckle using the SEMATECH Berkeley Actinic Inspection Tool (AIT). Modeling was used to test the effectiveness of the different metrologies in predicting the measured aerial-image speckle. AIT measured contrast values are 25% or more than the calculated image contrast values obtained using the measured rms roughness input. The extent to which the various metrologies can be utilized for specifying tolerable roughness limits on EUV masks is still to be determined. Further modeling and measurements are being planned.

36 MATERIALS SCIENCE↗

Apparatus and method for measuring single cell and sub-cellular photosynthetic efficiency

Devices for measuring single cell changes in photosynthetic efficiency in algal aquaculture are disclosed that include a combination of modulated LED trans-illumination of different intensities with synchronized through objective laser illumination and confocal detection. Synchronization and intensity modulation of a dual illumination scheme were provided using a custom microcontroller for a laser beam block and constant current LED driver. Therefore, single whole cell photosynthetic efficiency, and subcellular (diffraction limited) photosynthetic efficiency measurement modes are permitted. Wide field rapid light scanning actinic illumination is provided for both by an intensity modulated 470 nm LED. For the whole cell photosynthetic efficiency measurement, the same LED provides saturating pulses for generating photosynthetic induction curves. For the subcellular photosynthetic efficiency measurement, a switched through objective 488 nm laser provides saturating pulses for generating photosynthetic induction curves. A second near IR LED is employed to generate dark adapted states in the system under study.

42 ENGINEERING↗

Particle control near reticle and optics using showerhead

A method and an apparatus to protect a reticle against particles and chemicals in an actinic EUV reticle inspection tool are presented. The method and apparatus utilizes a pair of porous metal diffusers in the form of showerheads to provide a continual flow of clean gas. The main showerhead bathes the reticle surface to be inspected in smoothly flowing, low pressure gas, isolating it from particles coming from surrounding volumes. The secondary showerhead faces away from the reticle and toward the EUV illumination and projection optics, supplying them with purge gas while at the same time creating a buffer zone that is kept free of any particle contamination originating from those optics.

36 MATERIALS SCIENCE↗

Plant phenometrics systems and methods and devices related thereto

Chlorophyll fluorescence may be studied in response to a variety of environmental cues or conditions by growing phototrophic organisms under actinic illumination. Such illumination may be punctuated or disrupted to gain information about the photosynthetic properties or performance of the phototrophic organism. Instruments or devices for carrying out the method are also described.

47 OTHER INSTRUMENTATION↗

Benchmarking EUV mask inspection beyond 0.25 NA

The SEMATECH Berkeley Actinic Inspection Tool (AIT) is an EUV-wavelength mask inspection microscope designed for direct aerial image measurements, and pre-commercial EUV mask research. Operating on a synchrotron bending magnet beamline, the AIT uses an off-axis Fresnel zoneplate lens to project a high-magnification EUV image directly onto a CCD camera. We present the results of recent system upgrades that have improved the imaging resolution, illumination uniformity, and partial coherence. Benchmarking tests show image contrast above 75% for 100-nm mask features, and significant improvements and across the full range of measured sizes. The zoneplate lens has been replaced by an array of user-selectable zoneplates with higher magnification and NA values up to 0.0875, emulating the spatial resolution of a 0.35-NA 4 x EUV stepper. Illumination uniformity is above 90% for mask areas 2-{micro}m-wide and smaller. An angle-scanning mirror reduces the high coherence of the synchrotron beamline light source giving measured {sigma} values of approximately 0.125 at 0.0875 NA.

36 MATERIALS SCIENCE↗

Determining the critical size of EUV mask substrate defects

Determining the printability of substrate defects beneath the extreme ultraviolet (EUV) reflecting multilayer stack is an important issue in EUVL lithography. Several simulation studies have been performed in the past to determine the tolerable defect size on EUV mask blank substrates but the industry still has no exact specification based on real printability tests. Therefore, it is imperative to experimentally determine the printability of small defects on a mask blanks that are caused by substrate defects using direct printing of programmed substrate defect in an EUV exposure tools. SEMATECH fabricated bump type program defect masks using standard electron beam lithography and performed printing tests with the masks using an EUV exposure tool. Defect images were also captured using SEMATECH's Berkeley Actinic Imaging Tool in order to compare aerial defect images with secondary electron microscope images from exposed wafers. In this paper, a comprehensive understanding of substrate defect printability will be presented and printability specifications of EUV mask substrate defects will be discussed.

36 MATERIALS SCIENCE↗

Inspection 13.2 nm table-top full-field microscope

We present results on a table-top microscope that uses an EUV stepper geometry to capture full-field images with a halfpitch spatial resolution of 55 nm. This microscope uses a 13.2 nm wavelength table-top laser for illumination and acquires images of reflective masks with exposures of 20 seconds. These experiments open the path to the realization of high resolution table-top imaging systems for actinic defect characterization.

36 MATERIALS SCIENCE↗

Small Molecule-Induced Allosteric Activation of the Vibrio Cholerae RTX Cysteine Protease Domain

Vibrio cholerae RTX (repeats in toxin) is an actin-disrupting toxin that is autoprocessed by an internal cysteine protease domain (CPD). The RTX CPD is efficiently activated by the eukaryote-specific small molecule inositol hexakisphosphate (InsP{sub 6}), and we present the 2.1 angstrom structure of the RTX CPD in complex with InsP{sub 6}. InsP{sub 6} binds to a conserved basic cleft that is distant from the protease active site. Biochemical and kinetic analyses of CPD mutants indicate that InsP{sub 6} binding induces an allosteric switch that leads to the autoprocessing and intracellular release of toxin-effector domains.

59 BASIC BIOLOGICAL SCIENCES↗

Carbon contamination of extreme ultraviolet (EUV) mask and its effect on imaging

Carbon contamination of extreme ultraviolet (EUV) masks and its effect on imaging is a significant issue due to lowered throughput and potential effects on imaging performance. In this work, a series of carbon contamination experiments were performed on a patterned EUV mask. Contaminated features were then inspected with a reticle scanning electron microscope (SEM) and printed with the SEMA TECH Berkeley Microfield-Exposure tool (MET) [1]. In addition, the mask was analyzed using the SEMA TECH Berkeley Actinic-Inspection tool (AIT) [2] to determine the effect of carbon contamination on the absorbing features and printing performance. To understand the contamination topography, simulations were performed based on calculated aerial images and resist parameters. With the knowledge of the topography, simulations were then used to predict the effect of other thicknesses of the contamination layer, as well as the imaging performance on printed features.

36 MATERIALS SCIENCE↗

Hierarchical Bionanotubes Formed By the Self Assembly of Microtubules With Cationic Membranes Or Polypeptides

At present there is a surge in interest in biophysical research aimed at elucidating collective interactions between cellular proteins and associated biomolecules leading to supramolecular structures, with the ultimate goal of relating structure to function. The nerve cell cytoskeleton provides a rich example of highly ordered bundles and networks of interacting neurofilaments, microtubules and filamentous actin, where the nature of the interactions, structures and structure-function correlations remain poorly understood. We present synchrotron X-ray diffraction and electron microscopy data, in reconstituted protein systems from the bovine central nervous system, which reveal unexpected structures not predicted by current electrostatic theories. By mixing preassembled microtubules with charged membranes or polypeptides we found hierarchical bionanotubes made of microtubules coated by lipid bilayers or polypeptides, which in turn are coated with a third layer of tubulin oligomers forming rings or spirals.

60 APPLIED LIFE SCIENCES↗

Thorough characterization of a EUV mask

We reported that we were successful in our 45nm technology node device demonstration in February 2008 and 22nm node technology node device patterning in February 2009 using ASML's Alpha Demo Tool (ADT). In order to insert extreme ultraviolet (EUV) lithography at the 15nm technology node and beyond, we have thoroughly characterized one EUV mask, a so-called NOVACD mask. In this paper, we report on three topics, The first topic is an analysis of line edge roughness (LER) using a mask Scanning Electron Microscope (SEM), an Atomic Force Microscope (AFM) and the Actinic Inspection Tool (AIT) to compare resist images printed with the ASML ADT. The results of the analysis show a good correlation between the mask AFM and the mask SEM measurements, However, the resist printing results for the isolated space patterns are slightly different. The cause ofthis discrepancy may be resist blur, image log slope and SEM image quality and so on. The second topic is an analysis of mask topography using an AFM and relative reflectivity of mirror and absorber surface using the AIT, The AFM data show 6 and 7 angstrom rms roughness for mirror and absorber, respectively. The reflectivity measurements show that the mirror reflects EUV light about 20 times higher than absorber. The last topic is an analysis of a 32nm technology node SRAM cell which includes a comparison of mask SEM image, AIT image, resist image and simulation results. The ADT images of the SRAM pattern were of high quality even though the mask patters were not corrected for OPC or any EUV-specific effects. Image simulation results were in good agreement with the printing results.

36 MATERIALS SCIENCE↗

Using aberration test patterns to optimize the performance of EUV aerial imaging microscopes

The SEMATECH Berkeley Actinic Inspection Tool (AIT) is a prototype EUV-wavelength zoneplate microscope that provides high quality aerial image measurements of EUV reticles. To simplify and improve the alignment procedure we have created and tested arrays of aberration-sensitive patterns on EUV reticles and we have compared their images collected with the AIT to the expected shapes obtained by simulating the theoretical wavefront of the system. We obtained a consistent measure of coma and astigmatism in the center of the field of view using two different patterns, revealing a misalignment condition in the optics.

36 MATERIALS SCIENCE↗

Particle removal challenges with EUV patterned mask for the sub-22nm HP node

The particle removal efficiency (PRE) of cleaning processes diminishes whenever the minimum defect size for a specific technology node becomes smaller. For the sub-22 nm half-pitch (HP) node, it was demonstrated that exposure to high power megasonic up to 200 W/cm{sup 2} did not damage 60 nm wide TaBN absorber lines corresponding to the 16 nm HP node on wafer. An ammonium hydroxide mixture and megasonics removes {ge}50 nm SiO{sub 2} particles with a very high PRE, A sulfuric acid hydrogen peroxide mixture (SPM) in addition to ammonium hydroxide mixture (APM) and megasonic is required to remove {ge}28 nm SiO{sub 2} particles with a high PRE. Time-of-flight secondary ion mass spectroscopy (TOFSIMS) studies show that the presence of O{sub 2} during a vacuum ultraviolet (VUV) ({lambda} = 172 nm) surface conditioning step will result in both surface oxidation and Ru removal, which drastically reduce extreme ultraviolet (EUV) mask life time under multiple cleanings. New EUV mask cleaning processes show negligible or no EUV reflectivity loss and no increase in surface roughness after up to 15 cleaning cycles. Reviewing of defect with a high current density scanning electron microscope (SEM) drastically reduces PRE and deforms SiO{sub 2} particles. 28 nm SiO{sub 2} particles on EUV masks age very fast and will deform over time, Care must be taken when reviewing EUV mask defects by SEM. Potentially new particles should be identified to calibrate short wavelength inspection tools, Based on actinic image review, 50 nm SiO{sub 2} particles on top of the EUV mask will be printed on the wafer.

36 MATERIALS SCIENCE↗

Photon flux requirements for EUV reticle imaging microscopy in the 22 and 16 nm nodes

EUV-wavelength actinic microscopy yields detailed information about EUV mask patterns, architectures, defects, and the performance of defect repair strategies, without the complications of photoresist imaging. The measured aerial image intensity profiles provide valuable feedback to improve mask and lithography system modeling methods. In order to understand the photon-flux-dependent pattern measurement limits of EUV mask-imaging microscopy, we have investigated the effects of shot noise on aerial image linewidth measurements for lines in the 22 and 16-nm generations. Using a simple model of image formation near the resolution limit, we probe the influence of photon shot noise on the measured, apparent line roughness. With this methodology, we arrive at general flux density requirements independent of the specific EUV microscope configurations. Analytical and statistical analysis of aerial image simulations in the 22 and 16-nm generations reveal the trade-offs between photon energy density (controllable with exposure time), effective pixel dimension on the CCO (controlled by the microscope's magnification ratio), and image log slope (ILS). We find that shot-noise-induced linewidth roughness (LWR) varies imersely with the square root of the photon energy density, and is proportional to the imaging magnification ratio. While high magnification is necessary for adequate spatial resolution, for a given flux density, higher magnification ratios have diminishing benefits. With practical imaging parameters, we find that in order to achieve an LWR (3{sigma}) value of 5% of linewidth for dense, 88-nm mask features with 80% aerial image contrast and 13.5-nm effective pixel width (1000x magnification ratio), a peak photon flux of approximately 1400 photons per pixel per exposure is required.

36 MATERIALS SCIENCE↗

EUV pattern defect detection sensitivity based on aerial image linewidth measurements

As the quality of EUV-wavelength mask inspection microscopes improves over time, the image properties and intensity profiles of reflected light can be evaluated in ever-greater detail. The SEMATECH Berkeley Actinic Inspection Tool (AIT) is one such microscope, featuring mask resolution values that match or exceed those available through lithographic printing in current photoresists. In order to evaluate the defect detection sensitivity of the AIT for dense line patterns on typical masks, the authors study the line width roughness (LWR) on two masks, as measured in the EUV images. They report the through-focus and pitch dependence of contrast, image log slope, linewidth, and LWR. The AIT currently reaches LWR 3{sigma} values close to 9 nm for 175 nm half-pitch lines. This value is below 10% linewidth for nearly all lines routinely measured in the AIT. Evidence suggests that this lower level may arise from the mask's inherent pattern roughness. While the sensitivity limit of the AlT has not yet been established, it is clear that the AIT has the required sensitivity to detect defects that cause 10% linewidth changes in line sizes of 125 nm and larger.

36 MATERIALS SCIENCE↗