Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Neighboring suboptimal control for vehicle guidance

The neighboring optimal feedback control law is developed for systems with a piecewise linear control for the case where the optimal control is obtained by nonlinear programming techniques. To develop the control perturbation for a given deviation from the nominal path, the second variation is minimized subject to the constraint that the final conditions be satisfied (neighboring suboptimal control). This process leads to a feedback relationship between the control perturbation and the measured deviation from the nominal state. Neighboring suboptimal control is applied to the lunar launch problem. Two approaches, single optimization and multiple optimization for calculating the gains are used, and the gains are tested in a guidance simulation with a mismatch in the acceleration of gravity. Both approaches give acceptable results, but multiple optimization keeps the perturbed path closer to the nominal path.

Hull, David G.↗

The Hubble Space Telescope

The Hubble Space Telescope was launched from the Kennedy Space Center on April 24, 1990. Its initial check-out indicates that all sub-systems of the satellite are working very well, with two key exceptions: The line-of-sight pointing is subject to occasional jitter apparently induced by thermal stresses in the solar arrays; this is expected to be overcome. The telescope mirrors are found to contain approximately 0.5 wave rms of spherical aberration which cannot be overcome by any controls on board the satellite. This defect will limit the scientific performance of the telescope in the short run. However, the aberration can be fully corrected in the optical designs of future replacement instruments, and the delivery schedules of these instruments are being accelerated.

Boggess, Albert↗

Neighboring suboptimal control for vehicle guidance

The neighboring optimal feedback control law is developed for systems with a piecewise linear control for the case where the optimal control is obtained by nonlinear programming techniques. To develop the control perturbation for a given deviation from the nominal path, the second variation is minimized subject to the constraint that the final conditions be satisfied (neighboring suboptimal control). This process leads to a feedback relationship between the control perturbation and the measured deviation from the nominal state. Neighboring suboptimal control is applied to the lunar launch problem. Two approaches, single optimization and multiple optimization, for calculating the gains are used, and the gains are tested in a guidance simulation with a mismatch in the acceleration of gravity. Both approaches give acceptable results, but multiple optimization keeps the perturbed path closer to the nominal path.

Hull, David G.↗

Phase Change Materials for Photonics in NASA Science and Space Missions

Phase change materials (PCMs) such as Ge2Sb2Te5, Ge2Sb2Se4Te1, and Sb2S3have recently emerged as a promising platform to control light on-chip due to their fast, dramatic, and reversible change in refractive index. Significant technical progress in the field has been achieved in terms of improving optical transparency, controlling PCMs both optically and electrically, and integrating with complex photonic circuits, leading to exciting applications. When PCMs are mated with metasurfaces, devices are capable of controlling the phase and amplitude of propagating light with arrays of subwavelength structures. These enhance tunability and reconfigurability and continue to redefine the boundaries of optical sciences. PCM-based metasurface optics also help to accelerate the adoption of new architectures with reduced size, weight, and power (SWaP) for science and space mission platforms at NASA. In this talk, I will introduce two NASA-lead PCM photonic projects: 1. P-ACTIVE (PCM-based actively tunable filter) for broad imaging and sensing applications – from probing molecular vibrations in chemical species to detecting radiant thermal signatures of the space launch system. 2. PROWESS (Phase change reconfigurable optical wavefront synthesis system) as a beam steerer for both Earth and space LiDAR and free space optical communication applications. From this seminar, the attendees will be exposed not only to PCM-based photonic technologies but also NASA missions including the MISSE (Materials on the International Space Station Experiment) test campaign that was conducted to expose PCMs and PCM-based metasurfaces in space for 6 months in 2022.

phase change material↗

Trajectory Control in Rendezvous Problems Using Proportional Navigation

The rendezvous problem is defined by the end conditions that the position and velocity of a vehicle and its target are to be matched. In its present form proportional navigation theory allows the interception of a target by the vehicle, that is , the matching of positions. This report extends the theory to include the full rendezvous end conditions. Trajectory constraint equations are derived and the method of computing the required thrust program in idealized problems is outlined. The thrust program obtained results entirely from the trajectory and does not consider the dynamics of the vehicles or errors inherent in a real system. The properties of the thrust program, such as its variation both in magnitude and direction, are examined. An acceleration forcing function is also derived and its properties examined. The theory is applied to the satellite rendezvous problem as an example and some computations are presented.

Cicolani, Luigi S.↗

Exospheric density measurements from the drag-free satellite Triad

The Triad satellite is maintained within 1 mm of its proof mass (a small metal ball) in a purely gravitational orbit, using a drag-free control system, named Discos, as the disturbance compensation system. The Discos proof mass is surrounded by an outer shell which holds fuel tanks and cold gas jets. The shell shields the proof mass from such nongravitational forces as radiation pressure, atmospheric drag, and micrometeorite impact. Whenever these forces displace the outer shell relative to the proof mass, an error signal is generated by a capacitive bridge sensor, and the satellite is propelled by gas jets to remain centered on the proof mass when the error reaches 1 mm. Local atmospheric densities near 800 km were measured, using ball position data, and the observed accelerations were corrected for the effects of solar radiation pressure. The measured densities reveal a greater dependence on latitude than that indicated by balloon satellites, and also a dependence on longitude. Only a small dependence on Kp, however, was observed in the region where the measurements were made.

Moe, K.↗

A solar encounter mission - Starprobe

Accurate measurements of the internal mass distribution and dynamics of the sun as well as in situ observations of its environs are proposed through a JPL-designed satellite, STARPROBE. Scheduled for launch in 1988 under NASA's five-year plan, the probe will conduct radiometric experiments to determine the solar quadrupole moment (J2), fields-and-particles experiments (evaluating such phenomena as heating, acceleration, and peak random velocity of solar wind), and optical experiments potentially superior to those of the Earth-orbiting Solar Optical Telescope (SOT). With flight times ranging from 2.7 to 5.9 years, present delivery options comprise planetary gravity-assist trajectories that will give the spacecraft a perihelion of four solar radii at a 90 deg-inclination. Owing to science- and mission requirements, the thermal shield of the craft should tolerate a solar flux 3000 times greater than that at earth, radioisotope thermoelectric generators supplying 700 watts of power, and a three-axis stabilization system with reaction wheels providing control torque. Implementation concepts now under study may change some of the details of the design.

Randolph, J. E.↗

A 6 degree-of-freedom Lorentz force vibration isolator with nonlinear controller

This program demonstrated the technical feasibility of constructing large-stroke magnetic suspensions that can meet the active vibration isolation requirements of Space Station. These requirements include: (1) strokes over 1 cm in all directions, (2) actuator bandwidths over 100 Hz, (3) isolator roll-off frequencies below 10(exp -2) Hertz, and (4) force capability over 1 Newton in all axes. The 100 Hz actuator bandwidth allows the suspension to reject any direct force disturbances that act on the microgravity experiment, for example forces created by cable connections. The low isolator roll-off frequency and large stroke allow the magnetic suspension to isolate the microgravity experiment from Space Station vibrations above the roll-off frequency. The capability to meet these requirements was demonstrated by designing, constructing and testing a six-degree-of-freedom, prototype magnetic suspension system that featured high-performance, Lorentz-force actuators and full multi-input, multi-output control. This prototype suspension is designed to isolate large orbiter locker experiments under typical spacecraft constraints of size, weight, and power. Suspension in the full six-degrees-of-freedom was successfully demonstrated in this program while using a gravity-force unload mechanism to simulate a space environment. The prototype isolator is capable of space-based isolation service with relatively minor modification. The use of advanced, nonlinear control algorithms were investigated on a specially designed single-degree-of-freedom testbed. This low acceleration test facility simulates the Space Station vibration isolation problem in a single horizontal axis with low-friction, air-slide support. This allowed testing at the desired microgravity levels, without the gravity bias effects that are seen in a full six-degrees-of-freedom suspension. Precision components were used to reduce residual accelerations to microgravity levels so that the effects of sensor, actuator, and electronic noise could be evaluated. During the Phase 2 program, this testbed was used to demonstrate the advantages of nonlinear control algorithms to provide increased vibration isolation performance.

Fenn, Ralph↗

Space Acceleration Measurement System (SAMS)/Orbital Acceleration Research Experiment (OARE)

The Life and Microgravity Spacelab (LMS) payload flew on the Orbiter Columbia on mission STS-78 from June 20th to July 7th, 1996. The LMS payload on STS-78 was dedicated to life sciences and microgravity experiments. Two accelerometer systems managed by the NASA Lewis Research Center (LERC) flew to support these experiments, namely the Orbital Acceleration Research Experiment (OARE) and the Space Acceleration Measurements System (SAMS). In addition, the Microgravity Measurement Assembly (NOAA), managed by the European Space Research and Technology Center (ESA/ESTEC), and sponsored by NASA, collected acceleration data in support of the experiments on-board the LMS mission. OARE downlinked real-time quasi-steady acceleration data, which was provided to the investigators. The SAMS recorded higher frequency data on-board for post-mission analysis. The MMA downlinked real-time quasi-steady as well as higher frequency acceleration data, which was provided to the investigators. The Principal Investigator Microgravity Services (PIMS) project at NASA LERC supports principal investigators of microgravity experiments as they evaluate the effects of varying acceleration levels on their experiments. A summary report was prepared by PIMS to furnish interested experiment investigators with a guide to evaluate the acceleration environment during STS-78, and as a means of identifying areas which require further study. The summary report provides an overview of the STS-78 mission, describes the accelerometer systems flown on this mission, discusses some specific analyses of the accelerometer data in relation to the various activities which occurred during the mission, and presents plots resulting from these analyses as a snapshot of the environment during the mission. Numerous activities occurred during the STS-78 mission that are of interest to the low-gravity community. Specific activities of interest during this mission were crew exercise, radiator deployment, Vernier Reaction Control System (VRCS) reboost, venting operations, Flight Control System (FCS) checkout, rack excitation, operation of the Life Sciences Laboratory Equipment Refrigerator/Freezer (LSLE R/F), operation of the JSC Projects Centrifuge, crew sleep, and attitude changes. The low-gravity environment related to these activities is discussed in the summary report.

Hakimzadeh, Roshanak↗

A dynamic pressure calibration standard

A dynamic pressure calibration standard has been developed for calibrating flush diaphragm mounted pressure transducers. Pressures up to 20 kPa (3 psi) have been accurately generated over a frequency range of 50 to 1800 hz. The uncertainty of the standard is +/-5 pct to 5kPa (.75 psi) and +/-10 pct from 5 kPa (.75 psi) to 20 kPa (3 psi). The system consists of two conically shaped, aluminum columns, one 5 cm (2 in.) high for low pressures and another 11 cm (4.3 in.) high for higher pressures, each filled with a viscous fluid. A column is mounted on the armature of a vibration exciter which imparts a sinusoidally varying acceleration to the fluid column. Two pressure transducers mounted at the base of the column sense the sinusoidally varying pressure. This pressure is determined from measurements of the density of the fluid, the height of the fluid, and the acceleration of the column. A section of the taller column is filled with steel balls to control the damping of the fluid to extend its useful frequency range.

Schutte, P. C.↗

A long-duration balloon payload for hard X-ray and gamma-ray observations of the sun

A balloon payload designed to study the processes of energy release, particle acceleration, and heating of the active corona in hard X-ray microflares and normal flares is described. An array of liquid nitrogen-cooled germanium detectors together with large area phoswich scintillation detectors provide the highest sensitivity (about 500 sq cm) and energy resolution (not greater than 0.7 keV) ever achieved for solar hard X-ray (about 15-600 keV) measurements. These detectors were flown in February 1987 from Australia on a long duration radiation controlled balloon flight (LDBF) which provided 12 days of observations before cutdown in Brazil. The payload includes solar cells for power, pointing, and navigation sensors, a microprocessor controlled data system with VCR tape storage, and transmitters for GOES and ARGOS spacecraft. This successful flight illustrates the potential of LDBFs for solar flare studies.

Lin, R. P.↗

Coupled Growth in Hypermonotectics

The overall objective of this project is to obtain a fundamental understanding of the physics controlling solidification processes in immiscible alloy systems. The investigation involves both experimentation and the development of a model describing solidification in monotectic systems. The experimental segment was designed to first demonstrate that it is possible to obtain interface stability and steady state coupled growth in hypermonotectic alloys through microgravity processing. Microgravity results obtained to date have verified this possibility. Future flights will permit experimental determination of the limits of interface stability and the influence of alloy composition and growth rate on microstructure. The objectives of the modeling segment of the investigation include prediction of the limits of interface stability, modeling of convective flow due to residual acceleration, and the influence of surface tension driven flows at the solidification interface. The study of solidification processes in immiscible alloy systems is hindered by the inherent convective flow that occurs on Earth and by the possibility of sedimentation of the higher density immiscible liquid phase. It has been shown that processing using a high thermal gradient and a low growth rate can lead to a stable macroscopically planar growth front even in hypermonotectic alloys. Processing under these growth conditions can avoid constitutional supercooling and prevent the formation of the minor immiscible liquid phase in advance of the solidification front. However, the solute depleted boundary layer that forms in advance of the solidification front is almost always less dense than the liquid away from the solidification front. As a result, convective instability is expected. Ground based testing has indicated that convection is a major problem in these alloy systems and leads to gross compositional variations along the sample and difficulties maintaining interface stability. Sustained low gravity processing conditions are necessary in order to minimize these problems and obtain solidification conditions which approach steady state.

Andrews, J. Barry↗

The procedure safety system

Telerobotic operations, whether under autonomous or teleoperated control, require a much more sophisticated safety system than that needed for most industrial applications. Industrial robots generally perform very repetitive tasks in a controlled, static environment. The safety system in that case can be as simple as shutting down the robot if a human enters the work area, or even simply building a cage around the work space. Telerobotic operations, however, will take place in a dynamic, sometimes unpredictable environment, and will involve complicated and perhaps unrehearsed manipulations. This creates a much greater potential for damage to the robot or objects in its vicinity. The Procedural Safety System (PSS) collects data from external sensors and the robot, then processes it through an expert system shell to determine whether an unsafe condition or potential unsafe condition exists. Unsafe conditions could include exceeding velocity, acceleration, torque, or joint limits, imminent collision, exceeding temperature limits, and robot or sensor component failure. If a threat to safety exists, the operator is warned. If the threat is serious enough, the robot is halted. The PSS, therefore, uses expert system technology to enhance safety thus reducing operator work load, allowing him/her to focus on performing the task at hand without the distraction of worrying about violating safety criteria.

Obrien, Maureen E.↗

Effects of cholinergic and beta-adrenergic blockade on orthostatic tolerance in healthy subjects

Cardiovascular responses during a graded lower body negative pressure (LBNP) protocol were compared before and after atropine and propranolol administration to test the hypothesis that both sympathetic and parasympathetic control of cardio-acceleration are associated with syncopal predisposition to orthostatic stress in healthy subjects. Eleven men were categorized into two groups having high (HT, N = 6) or low (LT, N = 5) tolerance based on their total time before the onset of presyncopal symptoms. HT and LT groups were similar in physical characteristics, fitness, and baseline cardiovascular measurements. Atropine treatment had no effect on LBNP tolerance or mean arterial pressure at presyncope, despite an atropine-induced increase in heart rate. Propranolol treatment reduced (p<0.05) LBNP tolerance in both groups. Diminished LBNP tolerance after propranolol administration was associated with reductions in cardiac output, whereas increase in systemic peripheral resistance from baseline to presyncope was unaffected by propranolol. Reduction in cardiac output and LBNP tolerance after beta blockade reflected a chronotropic effect because lower LBNP tolerance for the HT (-50%) and LT (-39%) groups was associated with dramatic reductions (p <0.05) in the magnitude of LBNP-induced tachycardia without significant effects on stroke volume at presyncope. Absence of an atropine-induced difference in cardiac output and systemic peripheral resistance between HT and LT groups failed to support the notion that cardiac vagal withdrawal represents a predominant mechanism that could account for differences in orthostatic tolerance. Because a reduction in LBNP tolerance in both HT and LT groups after propranolol treatment was most closely associated with reduced tachycardia, the data suggest that a primary autonomically mediated mechanism for maintenance of mean arterial pressure and orthostatic tolerance in healthy subjects is beta adrenergic-induced tachycardia.

Non-NASA Center↗

Research on biophysical evaluation of the human vestibular system

The human vestibular function was studied by the combined approach of advanced measurement and mathematical modelling. Fundamental measurements of some physical properties of endolymph and perilymph, combined with nystagmus measurements and fluid mechanical analysis of semicircular canal function furthered the theory of canal mechanical response to angular acceleration, caloric stimulation and relating linear acceleration. The effects of adaptation seen at low frequency angular stimulation were studied and modelled to remove some shortcomings of the torsion pendulum models. Otolith function was also studied experimentally and analytically, leading to a new set of models for subjective orientation. Applications to special problems of space, including the case of rotating spacecraft were investigated and the interaction of visual and vestibular cues and their relation to proprioceptive information was explored relative to postural control.

Young, L. R.↗

Earth Independent Medical Operations (EIMO) Datascope: Challenges and Potential Solutions

Data flows and storage/retrieval capacity are severely constrained during missions in space and challenges will become even greater during exploration class missions. There is a need for an artificial intelligence (AI)-based clinical decision support system (CDSS) to monitor and analyze data to provide real-time consultative support for crew medical officer (CMO) decision-making. EIMO is defined as the gradual transition of medical care and decision making from terrestrial to space-based assets, enabling support of astronaut health and performance and reducing overall mission risk. While a hallmark of this paradigm shift from low-earth orbit is that on-board care will increasingly become the responsibility of the astronauts for primary management and decision making, terrestrial assets will continue to be paramount in pre-mission screening and planning, as well as prevention, health maintenance and long-term care contingencies. New capabilities and systems that enable progressively more robust and resilient systems and crews will be necessary to reduce risk and increase probability of deep space exploration mission success. An aspiration for EIMO is to develop AI-enhanced solutions for analysis of crew health & performance data and to facilitate clinical decision support for autonomous medical operations. A “system of systems” approach is envisioned whereby EIMO will deploy AI-supported natural language processing and machine learning (ML) techniques to utilize embedded reference databases and real-time data streams [input vectors] from multiple data sources. Constituent input vectors may include environmental controls, countermeasures data, behavioral data, physiologic wearables, point-of-care laboratory tests, personalized medical records, inventory trade space risk assessments, COTS medical databases, and ground support inputs. An ideal AI capability would possess trained fusion algorithms to cross reference input vectors with medical ‘knowledge’ [cultivated database] to stratify relevant data streams for predictive and actionable capabilities. In addition, EIMO will feature mobility, in that it can be accessed and can push/pull data within and between multiple vehicles/habitats. Large amounts and variable sources of data can be leveraged to diagnose, inform treatment strategies, and potentially predict medical events and performance decrements. Inclusion of advanced training tools using extended reality will enable increasingly autonomous medical care to aid a CMO when ground support is unavailable or time-delayed beyond required action window, e.g., emergent medical situations. EIMO CDSS would require very large datasets to train pre-flight and significant amounts of data are needed to support ML via in-flight CDSS operations. An additional challenge will be to find sufficient data to train a model relevant to astronaut demographics. The rapid, accelerating evolution of this field creates a propitious solution space to leverage multi-modal AI through public-private partnership(s). The status of multi-modal AI systems today would preclude their use for long duration missions as they remain unreliable and are subject to “digital hallucinations” and other errors that could pose operational risk. A federated labs structure is being considered to test and optimize data flow from the multiple input vectors leading to field testing in suitable ground/flight analogs. Critical to the success of an EIMO CDSS will be integration and interoperability and success will be defined by a system that can serve as an in-flight medical consult for the CMO providing critical support during medical contingencies. Benefits to terrestrial medicine may be significant as an outflow of the EIMO medical system, particularly for remote areas and communities lacking significant infrastructure, personnel and resources.

J Lemery↗

Earth Independent Medical Operations (EIMO) Datascope: Challenges and Potential Solutions

Data flows and storage/retrieval capacity are severely constrained during missions in space and challenges will become even greater during exploration class missions. There is a need for an artificial intelligence (AI)-based clinical decision support system (CDSS) to monitor and analyze data to provide real-time consultative support for crew medical officer (CMO) decision-making. EIMO is defined as the gradual transition of medical care and decision making from terrestrial to space-based assets, enabling support of astronaut health and performance and reducing overall mission risk. While a hallmark of this paradigm shift from low-earth orbit is that on-board care will increasingly become the responsibility of the astronauts for primary management and decision making, terrestrial assets will continue to be paramount in pre-mission screening and planning, as well as prevention, health maintenance and long-term care contingencies. New capabilities and systems that enable progressively more robust and resilient systems and crews will be necessary to reduce risk and increase probability of deep space exploration mission success. An aspiration for EIMO is to develop AI-enhanced solutions for analysis of crew health & performance data and to facilitate clinical decision support for autonomous medical operations. A “system of systems” approach is envisioned whereby EIMO will deploy AI-supported natural language processing and machine learning (ML) techniques to utilize embedded reference databases and real-time data streams [input vectors] from multiple data sources. Constituent input vectors may include environmental controls, countermeasures data, behavioral data, physiologic wearables, point-of-care laboratory tests, personalized medical records, inventory trade space risk assessments, COTS medical databases, and ground support inputs. An ideal AI capability would possess trained fusion algorithms to cross reference input vectors with medical ‘knowledge’ [cultivated database] to stratify relevant data streams for predictive and actionable capabilities. In addition, EIMO will feature mobility, in that it can be accessed and can push/pull data within and between multiple vehicles/habitats. Large amounts and variable sources of data can be leveraged to diagnose, inform treatment strategies, and potentially predict medical events and performance decrements. Inclusion of advanced training tools using extended reality will enable increasingly autonomous medical care to aid a CMO when ground support is unavailable or time-delayed beyond required action window, e.g., emergent medical situations. EIMO CDSS would require very large datasets to train pre-flight and significant amounts of data are needed to support ML via in-flight CDSS operations. An additional challenge will be to find sufficient data to train a model relevant to astronaut demographics. The rapid, accelerating evolution of this field creates a propitious solution space to leverage multi-modal AI through public-private partnership(s). The status of multi-modal AI systems today would preclude their use for long duration missions as they remain unreliable and are subject to “digital hallucinations” and other errors that could pose operational risk. A federated labs structure is being considered to test and optimize data flow from the multiple input vectors leading to field testing in suitable ground/flight analogs. Critical to the success of an EIMO CDSS will be integration and interoperability and success will be defined by a system that can serve as an in-flight medical consult for the CMO providing critical support during medical contingencies. Benefits to terrestrial medicine may be significant as an outflow of the EIMO medical system, particularly for remote areas and communities lacking significant infrastructure, personnel and resources.

Medical Operations↗

Static and transient performance of YF-102 engine with up to 14 percent core airbleed for the quiet short-haul research aircraft

An outdoor static test stand was used to measure the steady-state and transient performance of the YF-102 turbofan engine with core airbleed. The test configuration included a bellmouth inlet and a confluent-flow exhaust system similar in size to the quiet short-haul research aircraft (QSRA) exhaust system. For the steady-state tests, the engine operated satisfactorily with core bleed up to 14 percent of the core inlet flow. For the transient tests the engine accelerated and decelerated satisfactorily with no core bleed and with core bleed up to 11 percent of the core inlet flow (maximum tested). For some of the tests the core-bleed flow rate was scheduled to vary with fan discharge pressure, to simulate the QSRA bleed requirements. No stability, surge, stall, overtemperature, combustor flameout, or other operating problems were encountered in any of the tests. Steady-state and transient engine performance data are presented in graphs, and fuel-control trajectories for typical transient tests are shown.

Mcardle, J. G.↗