Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

A High-resolution TOF Detector _ A Possible Way to Compete with a RICH Detector

Using two identical 64-pixel Burle/Photonis MCP-PMTs to provide start and stop signals, they have achieved a timing resolution of {sigma}{sub Single{_}detector} {approx} 7.2 ps for N{sub pe} {approx} 50 photoelectrons (N{sub pe}) with a laser diode providing a 1 mm spot on the MCP window. The limiting resolution achieved was {sigma}{sub Single{_}detector} {approx} 5.0 ps for N{sub pe} {approx} 180, for which they estimate the MCP-PMT contribution of {sigma}{sub MCP-PMT} {approx} 4.5 ps. The electronics contribution is estimated as {sigma}{sub Electrons} = 3.42 ps. These results suggest that an ultra-high resolution TOF detector may become a reality at future experiments one day.

43 PARTICLE ACCELERATORS↗

Effects of Te inclusions on the performance of CdZnTe radiation detectors

Te inclusions existing at high concentrations in CdZnTe (CZT) material can degrade the performance of CZT detectors. These microscopic defects trap the free electrons generated by incident radiation, so entailing significant fluctuations in the total collected charge and thereby strongly affecting the energy resolution of thick (long-drift) detectors. Such effects were demonstrated in thin planar detectors, and, in many cases, they proved to be the dominant cause of the low performance of thick detectors, wherein the fluctuations in the charge losses accumulate along the charge's drift path. We continued studying this effect using different tools and techniques. We employed a dedicated beamline recently established at BNL's National Synchrotron Light Source for characterizing semiconductor radiation detectors, along with an IR transmission microscope system, the combination of which allowed us to correlate the concentration of defects with the devices performances. We present here our new results from testing over 50 CZT samples grown by different techniques. Our goals are to establish tolerable limits on the size and concentrations of these detrimental Te inclusions in CZT material, and to provide feedback to crystal growers to reduce their numbers in the material.

43 PARTICLE ACCELERATORS↗

INITIAL EVALUATION OF A PULSED WHITE SPECTRUM NEUTRON GENERATOR FOR EXPLOSIVE DETECTION

Successful explosive material detection in luggage and similar sized containers is acritical issue in securing the safety of all airline passengers. Tensor Technology Inc. has recently developed a methodology that will detect explosive compounds with pulsed fast neutron transmission spectroscopy. In this scheme, tritium beams will be used to generate neutrons with a broad energy spectrum as governed by the T(t,2n)4He fission reaction that produces 0-9 MeV neutrons. Lawrence Berkeley National Laboratory (LBNL), in collaboration with Tensor Technology Inc., has designedand fabricated a pulsed white-spectrum neutron source for this application. The specifications of the neutron source are demanding and stringent due to the requirements of high yield and fast pulsing neutron emission, and sealed tube, tritium operation. In a unique co-axial geometry, the ion source uses ten parallel rf induction antennas to externally couple power into a toroidal discharge chamber. There are 20 ion beam extraction slits and 3 concentric electrode rings to shape and accelerate the ion beam into a titanium cone target. Fast neutron pulses are created by using a set ofparallel-plate deflectors switching between +-1500 volts and deflecting the ion beams across a narrow slit. The generator is expected to achieve 5 ns neutron pulses at tritium ion beam energies between 80 - 120 kV. First experiments demonstrated ion source operation and successful beam pulsing.

43 PARTICLE ACCELERATORS↗

Gamma-Ray Large Area Space Telescope: Mission Overview

The new Gamma-ray Large Area Space Telescope (GLAST) is scheduled for launch in the middle of 2008. It contains the high energy gamma-ray telescope Large Area Telescope (LAT) which covers the energy range from 20 MeV to >300 GeV and the GLAST Burst Monitor (GMB), covering 8 keV-30 MeV energy range. The GLAST science objectives include understanding the mechanism of charged particle acceleration in active galactic nuclei, pulsars and supernova remnants, determining the nature of the still-unidentified EGRET sources, detailed study of gamma-ray diffuse emission, high-energy emission from gamma-ray bursts and transient sources, and probing dark matter. A brief overview of the mission is given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AFM CHARACTERIZATION OF RAMAN LASER INDUCED DAMAGE ON CDZNTECRYSTAL SURFACES

High quality CdZnTe (or CZT) crystals have the potential for use in room temperature gamma-ray and X-ray spectrometers. Over the last decade, the methods for growing high quality CZT have improved the quality of the produced crystals however there are material features that can influence the performance of these materials as radiation detectors. The presence of structural heterogeneities within the crystals, such as twinning, pipes, grain boundaries (polycrystallinity), and secondary phases (SPs) can have an impact on the detector performance. There is considerable need for reliable and reproducible characterization methods for the measurement of crystal quality. With improvements in material characterization and synthesis, these crystals may become suitable for widespread use in gamma radiation detection. Characterization techniques currently utilized to test for quality and/or to predict performance of the crystal as a gamma-ray detector include infrared (IR) transmission imaging, synchrotron X-ray topography, photoluminescence spectroscopy, transmission electron microscopy (TEM), atomic force microscopy (AFM) and Raman spectroscopy. In some cases, damage caused by characterization methods can have deleterious effects on the crystal performance. The availability of non-destructive analysis techniques is essential to validate a crystal's quality and its ability to be used for either qualitative or quantitative gamma-ray or X-ray detection. The work presented herein discusses the damage that occurs during characterization of the CZT surface by a laser during Raman spectroscopy, even at minimal laser powers. Previous Raman studies have shown that the localized annealing from tightly focused, low powered lasers results in areas of higher Te concentration on the CZT surface. This type of laser damage on the surface resulted in decreased detector performance which was most likely due to increased leakage current caused by areas of higher Te concentration. In this study, AFM was used to characterize the extent of damage to the CZT crystal surface following exposure to a Raman laser. AFM data reveal localized surface damage and increased conductivity in the areas exposed to the Raman laser beam.

43 PARTICLE ACCELERATORS↗

A Sealed, UHV Compatible, Soft X-ray Detector Utilizing Gas Electron Multipliers

An advanced soft X-ray detector has been designed and fabricated for use in synchrotron experiments that utilize X-ray absorption spectroscopy in the study a wide range of materials properties. Fluorescence X-rays, in particular C{sub K} at 277eV, are converted in a low pressure gas medium, and charge multiplication occurs in two gas electron multipliers, fabricated in-house from glass reinforced laminate, to enable single photon counting. The detector satisfies a number of demanding characteristics often required in synchrotron environments, such as UHV compatibility compactness, long-term stability, and energy resolving capability.

43 PARTICLE ACCELERATORS↗

Elemental X-ray Imaging Using the Maia Detector Array: The Benefits and Challenges of Large Solid-Angle

The fundamental parameter method for quantitative SXRF and PIXE analysis and imaging using the dynamic analysis method is extended to model the changing X-ray yields and detector sensitivity with angle across large detector arrays. The method is implemented in the GeoPIXE software and applied to cope with the large solid-angle of the new Maia 384 detector array and its 96 detector prototype developed by CSIRO and BNL for SXRF imaging applications at the Australian and NSLS synchrotrons. Peak-to-background is controlled by mitigating charge-sharing between detectors through careful optimization of a patterned molybdenum absorber mask. A geological application demonstrates the capability of the method to produce high definition elemental images up to {approx}100 M pixels in size.

43 PARTICLE ACCELERATORS↗

Self-Supplied Liquid Injection Field Desorption/Ionization Ion Source for an Orthogonal Time-of-Flight Instrument

A new implementation of a dedicated ion source for field ionization (FI), field desorption (FD), and liquid injection field desorption/ionization (LIFDI) for the JEOL AccuTOF GC series of orthogonal-acceleration time-of-flight instruments is presented. In contrast to existing implementations, this third-party LIFDI probe and source combination does not require the exchange of the entire ion source comprising ion source block and lens stack to switch from electron ionization (EI) to LIFDI. Rather, the methods may be swapped conveniently by only exchanging the ion source block for a mechanical probe guide and inserting the LIFDI probe in place of the standard direct insertion probe (DIP) via the vacuum lock. Further, this LIFDI setup does not require any changes of the electronics or software of the AccuTOF mass spectrometer because it is self-supplied in terms of power supply, observation optics, and computer control. The setup offers advanced FI/FD/LIFDI control features such as emission-controlled emitter heating current and emitter flash baking during elongated runs as required for gas chromatography-FI-mass spectrometry (MS). The LIFDI source and probe and its operation are reported in detail. FI spectra of the volatile analytes toluene, heptane, and pentafluoroiodobenzene are presented. LIFDI operation is demonstrated for the analysis of the saturated hydrocarbon dotriacontane and the low-mass hydrocarbon polymers polystyrene 484 and polystyrene 1050. Further, the air-sensitive 2nd-generation Hoveyda–Grubbs catalyst is analyzed by LIFDI-MS. For comparison with long-established LIFDI instrumentation, some of the spectra obtained with the new setup are also compared with those from a double-focusing magnetic sector instrument. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of gas-phase zirconium fluoroanions by electrospray of an ionic liquid

RATIONALE: When measuring extremely wide isotope ratios (= 1 x 109) accelerator mass spectrometry (AMS) is the instrument of choice, however it requires an anion for injection into the tandem accelerator. Since many elements do not have positive electronegativities they do not form stable negative atomic ions, and hence are not compatible for isotope ratio measurement using AMS. Thus new approaches for forming anions are sought; fluoroanions are particularly attractive because fluorine is monoisotopic, and thus will not have overlapping isobars with the isotope of interest. METHODS: An approach is described for making zirconium fluoroanions using the fluorinating ionic liquid (IL) 1-ethyl-3-methylimidazolium fluorohydrogenate, which was used to generate abundant [ZrF5-] using electrospray ionization. The IL was dissolved in acetonitrile, combined with a dilute solution of either Zr4+ or ZrO2+, and then electrosprayed. Mass analysis and collision induced dissociation were conducted using a time-of-flight mass spectrometer. Cluster structures were predicted using density functional theory calculations. RESULTS: The fluorohydrogenate IL solutions generated abundant [ZrF5-] starting from solutions of both Zr4+ and ZrO2+. The mass spectra also contained IL-bearing cluster ions, whose compositions indicated the presence of [ZrF6]2- in solution, a conclusion supported by the structural calculations. Rinsing out the zirconium-IL solution with acetonitrile decreased the IL clusters, but enhanced [ZrF5]-, which was sorbed by the polymeric electrospray supply capillary, and then released upon rinsing. This reduced the ion background in the mass spectrum. CONCLUSIONS: The fluorohydrogenate-IL solutions are a facile way to form zirconium fluoroanions in the gas phase using electrospray. The approach has potential as a source of fluoroanions for injection into an AMS, which would enable high-sensitivity measurement of minor zirconium isotopes, and benefits from the absence of overlapping isobars caused by the charge carrier (i.e., the monoisotopic fluorine atoms).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Matter in Extreme Conditions Instrument - Conceptual Design Report

The SLAC National Accelerator Laboratory (SLAC), in collaboration with Argonne National Laboratory (ANL), Lawrence Livermore National Laboratory (LLNL), and the University of California at Los Angeles (UCLA), is constructing a Free-Electron Laser (FEL) research facility. The FEL has already met its performance goals in the wavelength range 1.5 nm - 0.15 nm. This facility, the Linac Coherent Light Source (LCLS), utilizes the SLAC 2-Mile Linear Accelerator (linac) and will produce sub-picosecond pulses of short wavelength X-rays with very high peak brightness and almost complete transverse coherence. The final one-third of the SLAC linac is used as the source of electrons for the LCLS. The high energy electrons are transported across the SLAC Research Yard, into a tunnel which houses a long undulator. In passing through the undulator, the electrons are bunched by the force of their own synchrotron radiation and produce an intense, monochromatic, spatially coherent beam of X-rays. By varying the electron energy, the FEL X-ray wavelength is tunable from 1.5 nm to 0.15 nm. The LCLS includes two experimental halls as well as X-ray optics and infrastructure necessary to create a facility that can be developed for research in a variety of disciplines such as atomic physics, materials science, plasma physics and biosciences. This Conceptual Design Report, the authors believe, confirms the feasibility of designing and constructing an X-ray instrument in order to exploit the unique scientific capability of LCLS by creating extreme conditions and study the behavior of plasma under those controlled conditions. This instrument will address the Office of Science, Fusion Energy Sciences, mission objective related to study of Plasma and Warm Dense Matter as described in the report titled LCLS, the First Experiments, prepared by the LCLS Scientific Advisory Committee (SAC) in September 2000. The technical objective of the LCLS Matter in Extreme Conditions (MEC) Instrument project is to design, build, and install at the LCLS an X-ray instrument that will complement the initial instrument suite included in the LCLS construction and the LUSI Major Item of Equipment (MIE) Instruments. As the science programs advance and new technological challenges appear, instrumentation must be developed and ready to conquer these new opportunities. The MEC concept has been developed in close consultation with the scientific community through a series of workshops team meetings and focused reviews. In particular, the MEC instrument has been identified as meeting one of the most urgent needs of the scientific community based on the advice of the LCLS Scientific Advisory Committee (SAC) in response to an open call for letters of intent (LOI) from the breadth of the scientific community. The primary purpose of the MEC instrument is to create High Energy Density (HED) matter and measure its physical properties. There are three primary elements of the MEC instrument: (A) Optical laser drivers that will create HED states by irradiation in several ways and provide diagnostics capability; (B) The LCLS x-ray free electron laser, which will provide the unique capability to create, probe and selectively pump HED states; and, (C) A suite of diagnostic devices required to observe the evolution of the HED state. These elements when combined in the MEC instrument meet the 'Mission Need' as defined in CD-0. For the purposes of the description we separate the types of experiments to be performed into three categories: (1) High pressure: Here we are interested in the generation of high pressure using the optical lasers to irradiate a surface that ablates and drives a pressure wave into a sample, similar to a piston. The pressures that can be reached exceed 1 Mbar and the properties of interest are for example, the reflectivity, conductivity, opacity as well as the changes driven by the pressure wave on, e.g., condensed matter structure. These phenomena will be studied by means of diffraction measurements, measurements of the pressure wave characteristics, in situ probing by x-ray scattering of various types all time resolved. The necessary diagnostics are discussed.

43 PARTICLE ACCELERATORS↗

Control Systems Design for STS Accelerator

The Second Target Station (STS) Project will expand the capabilities of the existing Spallation Neutron Source (SNS), with a suite of neutron instruments optimized for long wavelengths. A new accelerator transport line will be built to deliver one out of four SNS pulses to the new target station. The Integrated Control Systems (ICS) will provide remote control, monitoring, OPI, alarms, and archivers for the accelerator systems, such as magnets power supply, vacuum devices, and beam instrumentation. The ICS will upgrade the existing Linac LLRF controls to allow independent operation of the FTS and STS and support different power levels of the FTS and STS proton beam. The ICS accelerator controls are in the phase of preliminary design for the control systems of magnet power supply, vacuum, LLRF, Timing, Machine protection system (MPS), and computing and machine network. The accelerator control systems build upon the existing SNS Machine Control systems, use the SNS standard hardware and EPICS software, and take full advantage of the performance gains delivered by the PPU Project at SNS.

Yan, Jay↗

Editorial: Biomass Modification, Characterization, and Process Monitoring Analytics to Support Biofuel and Biomaterial Production

This Frontiers Research Topic journeys through various challenges facing researchers seeking to develop fuels and products derived from lignocellulosic biomass. These challenges include: the rapid quantification of plant cell wall chemistry, enabling yields of potential monomeric sugars to be assessed, identification of plants possessing ideal trait that can be brought to the forefront of research efforts; once the native plant chemistry is known, how can yields be improved by chemically or genetically altering plant cell walls to reduce recalcitrance; does genetic modification of plants to increase accessibility to saccharification enzymes hinder the plant’s growth and/or function; are the innovative methods identified by researchers cost-effective and scalable to a commercial level? These topics are a sampling of the obstacles researchers combat when nominating a specific plant for downstream applications or implementing new deconstruction, genetic, or measurement strategies. How well can different plants can be broken down into useful, downstream precursor molecules? Efforts to develop a lucid picture of the chemical composition of abundant, diverse plants being explored as potential starting feedstocks has resulted in the evolution of high-throughput techniques that permit many more samples to be screened in much shorter periods of time. Advances in thermochemical and spectroscopic techniques have enabled the screening of thousands of plants for different phenotypes, such as cell-wall composition and monomeric sugar release. Some instrumental methods have been coupled with multivariate analysis, providing elegant chemometric predictive models enabling the accelerated identification of potential feedstocks. Rapid instrumental techniques have been developed for real-time monitoring of diverse processes, such as the efficacy of specific pretreatment strategies, or downstream products, such as biofuels and biomaterials. Real-time process monitoring techniques are needed for all stages of the feedstocks-to-biofuels conversion process to maximize efficiency and lower costs by monitoring and optimizing performance. These approaches allow researchers to adjust experimental conditions during, rather than at the conclusion, of processes, thereby decreasing overhead expenses.

09 BIOMASS FUELS↗

Cosmic Visions Dark Energy: Technology

A strong instrumentation and detector R&D program has enabled the current generation of cosmic frontier surveys. A small investment in R&D will continue to pay dividends and enable new probes to investigate the accelerated expansion of the universe. Instrumentation and detector R&D provide critical training opportunities for future generations of experimentalists, skills that are important across the entire Department of Energy High Energy Physics program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic Visions Dark Energy: Technology

A strong instrumentation and detector R&D program has enabled the current generation of cosmic frontier surveys. A small investment in R&D will continue to pay dividends and enable new probes to investigate the accelerated expansion of the universe. Instrumentation and detector R&D provide critical training opportunities for future generations of experimentalists, skills that are important across the entire DOE HEP program.

79 ASTRONOMY AND ASTROPHYSICS↗

On the possibility of footprint compression with one lens in nonlinear accelerator lattice

Electromagnetic interaction of colliding beams along with other nonlinear fields often limits the beams' lifetimes and luminosities. Nonlinearities result in the spread of betatron frequencies (footprint) and, thus, may enhance dynamic diffusion of particles due to high order resonances. One of the possible ways to eliminate nonlinearities and overcome the corresponding difficulties is compensation of nonlinear forces, but, in practice, it is hardly possible to obtain exact linearity of the system. The compensation with a single nonlinear lens cannot cope with distributed nonlinearities, nonlinearities due to parasitic crossings, etc. Here, we present a method to compute parameters of nonlinear element (lens) that eliminates both the footprint and resonance strength without achieving full compensation.

43 PARTICLE ACCELERATORS↗