The Countermeasure for the Noble Metal in the HLW Vitrification - the Removal Technology of Ru, Rh and Pd from the System - 16118
In this study, the system to separate ruthenium (Ru) in High-level radioactive liquid waste (HLLW), which has negative impact for the vitrification system, was investigated. It consists of three main parts. One is the process to remove Ru in HLLW by oxidizing Ru to RuO{sub 4} using ozone (O{sub 3}) and by heating to make RuO{sub 4} vaporize. Second one is the process collecting gas RuO{sub 4} vaporized from HLLW in the previous process. Final one is a degradation process of O{sub 3} which still remains. Several experiments were carried out to evaluate each process using the liquid waste simulating HLLW (SHLLW). As results of them, we found out bellows. (1) Approximately 100% of Ru could be removed from SHLLW by adding O{sub 3} to heated SHLLW in 80 degree C. (2) Over 80% of gas RuO{sub 4} was destructed to RuO{sub 2} particle in over 300 degree C without O{sub 2}/O{sub 3}. And nearly 100 % O{sub 3} gas was also degraded in the same condition. From those results, the system to remove Ru from HLLW before putting it into the glass melter must be realized by setting additional HLLW heating process with O{sub 3} supplying equipment and additional heating process of gas exhausted from the previous HLLW heating process. In the system, additional waste is not generated because of no additional solid and liquid chemicals. Moreover, we confirmed that DBP (di-butyl phosphate) which was added in SHLLW, was also degraded adding O{sub 3}. In addition, it was found that rhodium (Rh) and palladium (Pd) remained in glass make a low melting point alloy by adding TeO{sub 2} and its fluidity can be improved. (authors)