Search NASA⌕ Search

SEARCH · Search NASA

Results for “Arcing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

UZrCN Formation via Arc Melting – A Novel Synthesis Study

The next generation of nuclear reactors for both power production and space nuclear propulsion require fuel that is more durable, thermally stable, and more thermally conductive to support rapid heat transfer. High temperature gas reactors (HTGR), advanced gas reactors (AGR), and space-based nuclear thermal propulsion (NTP) are advanced reactor concepts that require a fuel type that can withstand high temperatures (1000-2900K) and flow of corrosive gas coolants such as helium, hydrogen, and carbon dioxide. One fuel with the potential to meet these demanding requirements is uranium-zirconium-carbonitride (UZrCN). UZrCN has many favorable fuel qualities compared to other eligible fuel forms such as uranium dioxide (UO2) and uranium mononitride (UN) that could support the aforementioned reactor concepts. UZrCN has an exceptionally high operating temperature and thermal conductivity which are highly desirable to improve reactor economics and safety. It far exceeds the properties of UO2 which is the most common fuel form in the United States. UZrCN also surpasses UN in terms of thermal conductivity and operating temperature by eliminating the dissociation problem UN has at 1700K. UZrCN could improve gas reactor performance and enable NTP technologies; however, it is an under-researched fuel that lacks rigorous scientific study. In recent efforts by the Idaho National Laboratory, a variety of novel methods to produce this fuel composition have been explored. One such method is via arc melting of uranium, zirconium, and carbon under a nitrogen atmosphere. Alloy fabrication using arc melting has been utilized for close to 150 years now and is well-understood as a method for rapid alloy prototyping. This process will be used to perform in-situ nitriding to form UZrCN.

36 MATERIALS SCIENCE↗

High Charge State Ions Extracted from Metal Plasmas in the Transition Regime from Vacuum Spark to High Current Vacuum Arc

Metal ions were extracted from pulsed discharge plasmas operating in the transition region between vacuum spark (transient high voltage of kV) and vacuum arc (arc voltage ~;; 20 V). At a peak current of about 4 kA, and with a pulse duration of 8 ?s, we observed mean ion charges states of about 6 for several cathode materials. In the case of platinum, the highest average charge state was 6.74 with ions of charge states as high as 10 present. For gold we found traces of charge state 11, with the highest average charge state of 7.25. At currents higher than 5 kA, non-metallic contaminations started to dominate the ion beam, preventing further enhancement of the metal charge states.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical Safety and Arc Flash Protections

Over the past four years, the Electrical Safety Program at PPPL has evolved in addressing changing regulatory requirements and lessons learned from accident events, particularly in regards to arc flash hazards and implementing NFPA 70E requirements. This presentation will discuss PPPL's approaches to the areas of electrical hazards evaluation, both shock and arc flash; engineered solutions for hazards mitigation such as remote racking of medium voltage breakers, operational changes for hazards avoidance, targeted personnel training and hazard appropriate personal protective equipment. Practical solutions for nominal voltage identification and zero voltage checks for lockout/tagout will also be covered. Finally, we will review the value of a comprehensive electrical drawing program, employee attitudes expressed as a personal safety work ethic, integrated safety management, and sustained management support for continuous safety improvement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preserved Neoproterozoic Continental Collision in Southeastern North America: The Brunswick Suture Zone and Osceola Continental Margin Arc

A series of exotic terranes were accreted to the eastern margin of southeastern Laurentia beginning in the Siluro-Devonian (Acadian event), and to the northeastern Laurentian margin beginning earlier (late Taconian). Many of these terranes have unclear tectonostratigraphic relationships to each other and to their parental cratons, but their accretionary history is critical to understanding the evolution of the Appalachian orogen. Two of these, the Gondwanan Suwannee and Charleston terranes, accreted during the Alleghanian orogeny and now lie beneath the Atlantic Coastal Plain in southeastern North America. Reanalysis of deep seismic reflection and well data reveals a preserved Neoproterozoic continental collision zone and associated continental margin arc, the Osceola arc, related to their juxtaposition. The subduction zone and associated strain are recorded in the newly termed Brunswick suture zone (BSZ). The BSZ is readily identified on a series of eight deep seismic reflection transects across the Brunswick Magnetic Anomaly (BMA), which we interpret as the boundary between the Charleston and Suwannee terranes. While originally interpreted to be the Late Paleozoic Alleghanian suture, new age constraints provided by the overlapping Gondwanan Paleozoic Suwannee Basin strata require the BSZ to predate the Early to Middle Paleozoic passive margin sequence of the Suwannee Basin. These results provide new insights into the tectonostratigraphic evolution of the Charleston and Suwannee terranes, the controversy surrounding the age and origin of the dipping seismic reflectors, previously attributed to the suturing of the Suwannee terrane to Laurentia, and the relationship of this suture zone to the origin of the BMA.

58 GEOSCIENCES↗

Heterogeneous Arc Discharge Plasma in a Magnetic Field

Results of investigation of the plasma processes proceeding upon cooling of the heterogeneous low-temperature argon-oxygen arc discharge plasma in an external magnetic field are presented. The oxygen content is kept on the level insufficient for complete oxidation of carbon vapors. Upon cooling of the low-temperature plasma containing comparable amounts of C and Fe atoms, the dispersed particles containing mixed microcrystals of carbon and iron oxides are formed. The particles formed from Cu and SiO{sub 2} vapors in the arc discharge plasma are also studied. It is established that in the presence of the external magnetic field, the dispersed particles of mixed C and Fe or Cu and SiO{sub 2} microcrystals have larger sizes than the particles formed in the absence of the magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the Modeling of Thermal Radiation at the Top Surface of a Vacuum Arc Remelting Ingot

Two models have been implemented for calculating the thermal radiation emitted at the ingot top in the VAR process, namely, a crude model that considers only radiative heat transfer between the free surface and electrode tip and a more detailed model that describes all radiative exchanges between the ingot, electrode, and crucible wall using a radiosity method. From the results of the second model, it is found that the radiative heat flux at the ingot top may depend heavily on the arc gap length and the electrode radius, but remains almost unaffected by variations of the electrode height. Both radiation models have been integrated into a CFD numerical code that simulates the growth and solidification of a VAR ingot. The simulation of a Ti-6-4 alloy melt shows that use of the detailed radiation model leads to some significant modification of the simulation results compared with the simple model. This is especially true during the hot-topping phase, where the top radiation plays an increasingly important role compared with the arc energy input. Thus, while the crude model has the advantage of its simplicity, use of the detailed model should be preferred.

36 MATERIALS SCIENCE↗

Study of Scanning Micro-arc Oxidation and Coating Development

Micro-arc oxidation (MAO) continues to be the focus of numerous investigations, whereas relatively few studies have considered scanning micro-arc oxidation (SMAO). In the present work, an experimental study was performed using stationary and moving electrodes to investigate coating development in SMAO and discern the effect of key process parameters. Examination of oxide deposits made on A356 aluminum show that coating thickness and growth rate are inversely related to inter-electrode spacing and travel speed. An evaluation of SMAO deposits made by stationary and moving nozzles revealed that coating thickness profiles follow a Gaussian distribution due to the electrolyte flow field in the impingement zone. Hardness surveys and scanning electron microscope analysis of SMAO coatings revealed that micro-hardness distributions and cross-sectional morphology are similar to MAO for a stationary nozzle but that a denser outer layer develops when a moving nozzle is used. This is attributed to a high density of discharge occurring in micropores of the oxide film and remelting which results from the moving electrolyte column. Analysis of voltage–current characteristic curves shows that the resistance of the electrolyte column is essentially linear over the range considered and results indicate that it can be modeled as a variable length resistor. While further testing is needed, results confirm that SMAO is suitable for coating large, planar parts and for repairing worn surfaces.

36 MATERIALS SCIENCE↗

Effect of Coil Current on the Properties of Hydrogenated DLC Coatings Fabricated by Filtered Cathodic Vacuum Arc Technique

We successfully prepared hydrogenated DLC (a-C:H) with a thickness higher than 25 μm on stainless steel using a filtered cathode vacuum arc (FCVA) technique. The structural and mechanical properties of DLC were systematically analyzed using different methods such as x-ray photoelectron spectroscopy, Raman spectroscopy, scanning electron microscopy, Vickers hardness, nanohardness, and friction and wear tests. The effect of coil current on the arc voltage, ion current, and mechanical properties of resultant films was systematically investigated. The novelty of this study is the fabrication of DLC with Vickers hardness higher than 1500 HV, in the meanwhile with the thickness higher than 30 μm through varying the coil current with FCVA technique. The results indicated that the ion current, deposition rate, friction coefficient, and Vickers hardness of DLC were significantly affected by the magnetic field inside the filtered duct.

36 MATERIALS SCIENCE↗

Effect of N 2 - and CO 2 -containing shielding gases on composition modification and carbonitride precipitation in wire arc additive manufactured grade 91 steel

Additive manufacturing (AM) represents a promising technique to fabricate metallic alloys with greater control of the resulting material features as compared to traditional manufacturing routes. Recently, there is greater interest in AM research on 9 wt% Cr ferritic/martensitic (F/M) steels, which are commonly studied for use in the nuclear energy industry. This work aims to prove that wire arc AM can manufacture F/M steels with adequate mechanical properties in multiple processing atmospheres and aims to study how shielding gas composition can be leveraged during fabrication to induce specific precipitation pathways. The effect of shielding gas composition on MX (M=Nb and/or V, Xdouble bondC and/or N) carbonitride precipitation in a 9 wt% Cr ferritic/martensitic (F/M) steel alloy known as Grade 91 was studied using N 2 and CO 2 gas additions to an inert Ar shielding gas atmosphere during wire arc AM. The N and C atoms present in the processing atmospheres were absorbed into the melt pools during fabrication. Due to their differing affinities for precipitate-forming reactions, the varying levels of C and N between the samples contributed to differences in final carbonitride composition and morphologies. Such precipitate behavior is of interest as carbonitrides have been shown to contribute to increased mechanical performance. This increased performance was studied via electron microscopy and tested for strength, ductility, and fracture properties.

36 MATERIALS SCIENCE↗

Conceptual design study for heat exhaust management in the ARC fusion pilot plant

The ARC pilot plant conceptual design study has been extended beyond its initial scope to explore options for managing ∼525 MW of fusion power generated in a compact, high field (B 0 = 9.2 T) tokamak that is approximately the size of JET (R 0 = 3.3 m). Taking advantage of ARC’s novel design – demountable high temperature superconductor toroidal field (TF) magnets, poloidal magnetic field coils located inside the TF, and vacuum vessel (VV) immersed in molten salt FLiBe blanket – this follow-on study has identified innovative and potentially robust power exhaust management solutions. The superconducting poloidal field coil set has been reconfigured to produce double-null plasma equilibria with a long-leg X-point target divertor geometry. Here this design choice is motivated by recent modeling which indicates that such configurations enhance power handling and may attain a passively-stable detachment front that stays in the divertor leg over a wide power exhaust window. A modified VV accommodates the divertor legs while retaining the original core plasma volume and TF magnet size. The molten salt FLiBe blanket adequately shields all superconductors, functions as an efficient tritium breeder, and, with augmented forced flow loops, serves as an effective single-phase, low-pressure coolant for the divertor, VV, and breeding blanket. Advanced neutron transport calculations (MCNP) indicate a tritium breeding ratio of ∼1.08. The neutron damage rate (DPA/year) of the remote divertor targets is ∼3–30 times lower than that of the first wall. The entire VV (including divertor and first wall) can tolerate high damage rates since the demountable TF magnets allow the VV to be replaced every 1–2 years as a single unit, employing a vertical maintenance scheme. A tungsten swirl tube FLiBe coolant channel design, similar in geometry to that used by ITER, is considered for the divertor heat removal and shown capable of exhausting divertor heat flux levels of up to 12 MW/m 2 . Several novel, neutron tolerant diagnostics are explored for sensing power exhaust and for providing feedback control of divertor conditions over long time scales. These include measurement of Cherenkov radiation emitted in FLiBe to infer DT fusion reaction rate, measurement of divertor detachment front locations in the divertor legs with microwave interferometry, and monitoring “hotspots” on the divertor chamber walls via IR imaging through the FLiBe blanket.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conformal Arc Radiotherapy for Prostate Cancer: Increased Biochemical Failure in Patients With Distended Rectum on the Planning Computed Tomogram Despite Image Guidance by Implanted Markers

Purpose: To evaluate the effect of rectal distention on the planning computed tomogram on freedom from biochemical failure (FFBF) of prostate cancer patients treated with image-guided conformal arc radiotherapy. Methods and Materials: The outcomes of 238 patients with T1-T3N0M0 tumors were analyzed, with a median follow-up of 53 months (range, 24-93 months). In 213 patients, daily co-registration of X-rays and digitally reconstructed radiographs was used for positioning, whereas in 25 patients positioning was done using direct prostate visualization with implanted markers. The rectal average cross-sectional area was determined on the planning computed tomogram. Results: The 5-year freedom from Grade 3 to 4 late gastrointestinal and urinary side effect, according to the Radiation Therapy Oncology Group criteria, was 100% and 99.4% respectively. The 5-year FFBF was 88.4%. On multivariate analysis the following variables were significantly related to worse FFBF: risk group according to the National Comprehensive Cancer Network (high- to very high risk vs. intermediate- to low-risk), dose (70 vs. 78 Gy), average cross-sectional area ({>=}16 vs. <16 cm{sup 2}) and, unexpectedly, the use of implanted markers as opposed to bony structures for patient positioning. In retrospect, the margins around the clinical target volume appeared to be inadequate in the cases in which markers were used. Conclusion: Overall, the outcome of patients treated with image-guided conformal arc radiotherapy is excellent. We were able to confirm the negative prognostic impact of a distended rectum on the planning computed tomogram described by others. The study illustrates the potential danger of image guidance techniques as to margin reduction around the clinical target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Volumetric Modulated Arc Therapy and Conventional Intensity-Modulated Radiotherapy for Frontal and Temporal High-Grade Gliomas

Purpose: Volumetric modulated arc therapy (VMAT), the predecessor to Varian's RapidArc, is a novel extension of intensity-modulated radiotherapy (IMRT) wherein the dose is delivered in a single gantry rotation while the multileaf collimator leaves are in motion. Leaf positions and the weights of field samples along the arc are directly optimized, and a variable dose rate is used. This planning study compared seven-field coplanar IMRT (cIMRT) with VMAT for high-grade gliomas that had planning target volumes (PTVs) overlapping organs at risk (OARs). Methods and Materials: 10 previously treated patients were replanned to 60 Gy in 30 fractions with cIMRT and VMAT using the following planning objectives: 98% of PTV covered by 95% isodose without violating OAR and hotspot dose constraints. Mean OAR doses were maximally decreased without reducing PTV coverage or violating hotspot constraints. We compared dose-volume histogram data, monitor units, and treatment times. Results: There was equivalent PTV coverage, homogeneity, and conformality. VMAT significantly reduced maximum and mean retinal, lens, and contralateral optic nerve doses compared with IMRT (p < 0.05). Brainstem, chiasm, and ipsilateral optic nerve doses were similar. For 2-Gy fractions, mean monitor units were as follows: cIMRT = 789 +- 112 and VMAT = 363 +- 45 (relative reduction 54%, p = 0.002), and mean treatment times (min) were as follows: cIMRT = 5.1 +- 0.4 and VMAT = 1.8 +- 0.1 (relative reduction 65%, p = 0.002). Conclusions: Compared with cIMRT, VMAT achieved equal or better PTV coverage and OAR sparing while using fewer monitor units and less time to treat high-grade gliomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Arc Intensity-Modulated Therapy for Spine Body Radiotherapy: Comparison With Static Intensity-Modulated Treatment

Purpose: This clinical study evaluates the feasibility of using volumetric arc-modulated treatment (VMAT) for spine stereotactic body radiotherapy (SBRT) to achieve highly conformal dose distributions that spare adjacent organs at risk (OAR) with reduced treatment time. Methods and Materials: Ten spine SBRT patients were studied retrospectively. The intensity-modulated radiotherapy (IMRT) and VMAT plans were generated using either one or two arcs. Planning target volume (PTV) dose coverage, OAR dose sparing, and normal tissue integral dose were measured and compared. Differences in treatment delivery were also analyzed. Results: The PTV DVHs were comparable between VMAT and IMRT plans in the shoulder (D{sub 99%}-D{sub 90%}), slope (D{sub 90%}-D{sub 10%}), and tail (D{sub 10%}-D{sub 1%}) regions. Only VMAT{sub 2arc} had a better conformity index than IMRT (1.09 vs. 1.15, p = 0.007). For cord sparing, IMRT was the best, and VMAT{sub 1arc} was the worst. Use of IMRT achieved greater than 10% more D{sub 1%} sparing for six of 10 cases and 7% to 15% more D{sub 10%} sparing over the VAMT{sub 1arc}. The differences between IMRT and VAMT{sub 2arc} were smaller and statistically nonsignificant at all dose levels. The differences were also small and statistically nonsignificant for other OAR sparing. The mean monitor units (MUs) were 8711, 7730, and 6317 for IMRT, VMAT{sub 1arc}, and VMAT{sub 2arc} plans, respectively, with a 26% reduction from IMRT to VMAT{sub 2arc}. The mean treatment time was 15.86, 8.56, and 7.88 min for IMRT, VMAT{sub 1arc,} and VMAT{sub 2arc}. The difference in integral dose was statistically nonsignificant. Conclusions: Although VMAT provided comparable PTV coverage for spine SBRT, 1arc showed significantly worse spinal cord sparing compared with IMRT, whereas 2arc was comparable to IMRT. Treatment efficiency is substantially improved with the VMAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Critical Appraisal of Volumetric Modulated Arc Therapy in Stereotactic Body Radiation Therapy for Metastases to Abdominal Lymph Nodes

Purpose: A planning study was performed comparing volumetric modulated arcs, RapidArc (RA), fixed beam IMRT (IM), and conformal radiotherapy (CRT) with multiple static fields or short conformal arcs in a series of patients treated with hypofractionated stereotactic body radiation therapy (SBRT) for solitary or oligo-metastases from different tumors to abdominal lymph nodes. Methods and Materials: Fourteen patients were included in the study. Dose prescription was set to 45 Gy (mean dose to clinical target volume [CTV]) in six fractions of 7.5 Gy. Objectives for CTV and planning target volume (PTV) were as follows: Dose{sub min} >95%, Dose{sub max} <107%. For organs at risk the following objectives were used: Maximum dose to spine <18 Gy; V{sub 15Gy} <35% for both kidneys, V{sub 36Gy} <1% for duodenum, V{sub 36Gy} <3% for stomach and small bowel, V{sub 15Gy} <(total liver volume - 700 cm{sup 3}) for liver. Dose-volume histograms were evaluated to assess plan quality. Results: Planning objectives on CTV and PTV were achieved by all techniques. Use of RA improved PTV coverage (V{sub 95%} = 90.2% +- 5.2% for RA compared with 82.5% +- 9.6% and 84.5% +- 8.2% for CRT and IM, respectively). Most planning objectives for organs at risk were met by all techniques except for the duodenum, small bowel, and stomach, in which the CRT plans exceeded the dose/volume constraints in some patients. The MU/fraction values were as follows: 2186 +- 211 for RA, 2583 +- 699 for IM, and 1554 +- 153 for CRT. Effective treatment time resulted as follows: 3.7 +- 0.4 min for RA, 10.6 +- 1.2 min for IM, and 6.3 +- 0.5 min for CRT. Conclusions: Delivery of SBRT by RA showed improvements in conformal avoidance with respect to standard conformal irradiation. Delivery parameters confirmed logistical advantages of RA, particularly compared with IM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulated Arc Therapy Improves Dosimetry and Reduces Treatment Time Compared to Conventional Intensity-Modulated Radiotherapy for Locoregional Radiotherapy of Left-Sided Breast Cancer and Internal Mammary Nodes

Purpose: Volumetric modulated arc therapy (VMAT) is a novel extension of conventional intensity-modulated radiotherapy (cIMRT), in which an optimized three-dimensional dose distribution may be delivered in a single gantry rotation. VMAT is the predecessor to RapidArc (Varian Medical System). This study compared VMAT with cIMRT and with conventional modified wide-tangent (MWT) techniques for locoregional radiotherapy for left-sided breast cancer, including internal mammary nodes. Methods and Materials: Therapy for 5 patients previously treated with 50 Gy/25 fractions using nine-field cIMRT was replanned with VMAT and MWT. Comparative endpoints were planning target volume (PTV) dose homogeneity, doses to surrounding structures, number of monitor units, and treatment delivery time. Results: For VMAT, two 190 deg. arcs with 2-cm overlapping jaws were required to optimize over the large treatment volumes. Treatment plans generated using VMAT optimization resulted in PTV homogeneity similar to that of cIMRT and MWT. The average heart volumes receiving >30 Gy for VMAT, cIMRT, and MWT were 2.6% +- 0.7%, 3.5% +- 0.8%, and 16.4% +- 4.3%, respectively, and the average ipsilateral lung volumes receiving >20 Gy were 16.9% +- 1.1%, 17.3% +- 0.9%, and 37.3% +- 7.2%, respectively. The average mean dose to the contralateral medial breast was 3.2 +- 0.6 Gy for VMAT, 4.3 +- 0.4 Gy for cIMRT, and 4.4 +- 4.7 Gy for MWT. The healthy tissue volume percentages receiving 5 Gy were significantly larger with VMAT (33.1% +- 2.1%) and IMRT (45.3% +- 3.1%) than with MWT (19.4% +- 3.7%). VMAT reduced the number of monitor units by 30% and the treatment time by 55% compared with cIMRT. Conclusions: VMAT achieved similar PTV coverage and sparing of organs at risk, with fewer monitor units and shorter delivery time than cIMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulation Arc Radiotherapy Compared With Static Gantry Intensity-Modulated Radiotherapy for Malignant Pleural Mesothelioma Tumor: A Feasibility Study

Purpose: A planning study was performed to evaluate RapidArc (RA), a volumetric modulated arc technique, on malignant pleural mesothelioma. The benchmark was conventional fixed-field intensity-modulated radiotherapy (IMRT). Methods and materials: The computed tomography data sets of 6 patients were included. The plans for IMRT with nine fixed beams were compared against double-modulated arcs with a single isocenter. All plans were optimized for 15-MV photon beams. The dose prescription was 54 Gy to the planning target volume. The planning objectives for the planning target volume were a minimal dose of >95% and maximal dose of <107%. For the organs at risk, the parameters were as follows: contralateral lung, percentage of volume receiving 5 Gy (V{sub 5Gy}) <60%, V{sub 20Gy} < 10%, mean <10.0 Gy; liver, V{sub 30Gy} <33%, mean <31 Gy; heart, V{sub 45Gy} <30%, V{sub 50Gy} <20%, dose received by 1% of the volume (D{sub 1%}) <60 Gy; contralateral kidney, V{sub 15Gy} <20%; spine, D{sub 1%} <45 Gy; esophagus, V{sub 55Gy} <30%; and spleen, V{sub 40Gy} <50%. The monitor units (MUs) and delivery time were scored to measure the treatment efficiency. The pretreatment portal dosimetry scored delivery to the calculation agreement with the Gamma Agreement Index. Results: RA and IMRT provided equivalent coverage and homogeneity. Both techniques fulfilled objectives on organs at risk with a tendency of RA to improve sparing. The conformity index was 1.9 {+-} 0.1 for RA and IMRT. The number of MU/2Gy was 734 {+-} 82 for RA and 2,195 {+-} 317 for IMRT. The planning vs. delivery agreement revealed a Gamma Agreement Index for IMRT of 96.0% {+-} 2.6% and for RA of 95.7% {+-} 1.5%. The treatment time was 3.7 {+-} 0.3min for RA and 13.4 {+-} 0.1min for IMRT. Conclusion: RA demonstrated compared with conventional IMRT, similar target coverage and better dose sparing to the organs at risks. The number of MUs and the time required to deliver a 2-Gy fraction were much lower for RA, allowing the possibility to incorporate this technique in the treatment options for mesothelioma patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological and Clinical Pneumonitis After Stereotactic Lung Radiotherapy: A Matched Analysis of Three-Dimensional Conformal and Volumetric-modulated Arc Therapy Techniques

Purpose: Lung fibrosis is common after stereotactic body radiotherapy (SBRT) for lung tumors, but the influence of treatment technique on rates of clinical and radiological pneumonitis is not well described. After implementing volumetric modulated arc therapy (RapidArc [RA]; Varian Medical Systems, Palo Alto, CA) for SBRT, we scored the early pulmonary changes seen with arc and conventional three-dimensional SBRT (3D-CRT). Methods and Materials: Twenty-five SBRT patients treated with RA were matched 1:2 with 50 SBRT patients treated with 3D-CRT. Dose fractionations were based on a risk-adapted strategy. Clinical pneumonitis was scored using Common Terminology Criteria for Adverse Events version 3.0. Acute radiological changes 3 months posttreatment were scored by three blinded observers. Relationships among treatment type, baseline factors, and outcomes were assessed using Spearman's correlation, Cochran-Mantel-Haenszel tests, and logistic regression. Results: The RA and 3D-CRT groups were well matched. Forty-three patients (57%) had radiological pneumonitis 3 months after treatment. Twenty-eight patients (37%) had computed tomography (CT) findings of patchy or diffuse consolidation, and 15 patients (20%) had ground-glass opacities only. Clinical pneumonitis was uncommon, and no differences were seen between 3D-CRT vs. RA patients in rates of grade 2/3 clinical pneumonitis (6% vs. 4%, respectively; p = 0.99), moderate/severe radiological changes (24% vs. 36%, respectively, p = 0.28), or patterns of CT changes (p = 0.47). Radiological severity scores were associated with larger planning target volumes (p = 0.09) and extended fractionation (p = 0.03). Conclusions: Radiological changes after lung SBRT are common with both approaches, but no differences in early clinical or radiological findings were observed after RA. Longer follow-up will be required to exclude late changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Arc Therapy and Intensity-Modulated Radiotherapy for Primary Prostate Radiotherapy With Simultaneous Integrated Boost to Intraprostatic Lesion With 6 and 18 MV: A Planning Comparison Study

Purpose: The aim of the present study was to compare intensity-modulated radiotherapy (IMRT) with volumetric arc therapy (VMAT), in the treatment of prostate cancer with maximal dose escalation to the intraprostatic lesion (IPL), without violating the organ-at-risk constraints. Additionally, the use of 6-MV photons was compared with 18-MV photons for all techniques. Methods and Materials: A total of 12 consecutive prostate cancer patients with an IPL on magnetic resonance imaging were selected for the present study. Plans were made for three IMRT field setups (three, five, and seven fields) and one VMAT field setup (single arc). First, optimal plans were created for every technique using biologic and physical planning aims. Next, an additional escalation to the IPL was planned as high as possible without violating the planning aims of the first step. Results: No interaction between the technique and photon energy (p = .928) occurred. No differences were found between the 6- and 18-MV photon beams, except for a reduction in the number of monitor units needed for 18 MV (p < .05). All techniques, except for three-field IMRT, allowed for dose escalation to a median dose of {>=}93 {+-} 6 Gy (mean {+-} standard deviation) to the IPL. VMAT was superior to IMRT for rectal volumes receiving 20-50 Gy (p < .05). Conclusion: VMAT allowed for dose escalation to the IPL with better sparing of the rectum than static three-, five-, and seven-field IMRT setups. High-energy photons had no advantage over low-energy photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗