Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

OpenFacadeControl: enabling integration of automated facades with other building systems

Automated facades are, for the most part, still considered as separate from other building systems throughout the design, installation, commissioning, operation, and maintenance cycle. This takes place despite the fact that their energy and comfort performance are deeply interlinked with the operation of lighting and HVAC systems. Over the last two decades, research has shown that there are significant advantages from operating facades as an integrated system with the rest of the building. Nevertheless, significant barriers prevent this type of integration becoming more common. One of them is the lack of a platform that is inexpensive to implement and that easily allows the practical implementation of integrated control algorithms across fenestration and other building systems, using a variety of communications protocols. This is particularly challenging when automated facades are installed in existing buildings, where interaction with legacy building systems that were installed over the past lifetime of the building can require a high degree of interoperability. OpenFacadeControl (OFC) is an open-source controls framework aimed at unified control of facades and other building systems, including the sharing of third-party sensor information. Through leveraging the Volttron controls platform, it allows the integration of systems and sensors that are manufactured by different companies and that use different communications protocols into an ensemble that functions as a single system. OFC is designed to enable integrated control algorithms of varying degrees of complexity, ranging from simple, heuristic controls to more sophisticated approaches like model-predictive control. Use of a research version to test advanced lighting and shading strategies in a full-scale experimental testbed has demonstrated the ease of deploying advanced control solutions using OpenFacadeControl. This paper presents the structure of OpenFacadeControl and a demonstration case showing the use of OFC in laboratory tests of advanced lighting and fenestration controls that coordinated motorized shades communicating via the BACnet building communications standard and lights communicating via internet-protocol-based application programming interface (API), based on the readings of a shared light level sensor communicating via a different API.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Light-Modulated Self-Assembly of Synthetic Nanotubes

Artificial biomolecular polymers with the capacity to respond to stimuli are emerging as a key component to the development of living materials and synthetic cells. Here, in this work, we demonstrate artificial DNA tubular nanostructures that form in response to light in a dose-dependent manner. These nanotubes assemble from programmable DNA tile motifs that are engineered to include a UV-responsive domain so that UV irradiation activates nanotube self-assembly. We demonstrate that the nanotube formation speed can be tuned by adjusting the UV dose. We then couple the light-dependent activation of tiles with RNA transcription, making it possible to control nanotube formation via concurrent physical and biochemical stimuli. Finally, we illustrate how UV activation effectively controls nanotube assembly in confinement as a rudimentary stimulus-responsive cytoskeletal system that can achieve various conformations in a minimal synthetic cell. This study contributes new tile designs that are immediately useful to building biomolecular scaffolds with controllable dynamics in response to multiple stimuli.

DNA nanotechnology↗

Measure Guideline: Condensing Boilers—Control Strategies for Optimizing Performance and Comfort in Residential Applications

The combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater has become a common option for high-efficiency residential space heating in cold climates. While there are many condensing boilers available on the market with rated efficiencies in the low to mid 90% efficient range, it is imperative to understand that if the control systems are not properly configured, these heaters will perform no better than their non-condensing counterparts. Based on previous research efforts, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency (Arena 2010). It was found that there is a significant lack of information for contractors on how to configure the control systems to optimize overall efficiency. For example, there is little advice on selecting the best settings for the boiler reset curve or how to measure and set flow rates in the system to ensure that the return temperatures are low enough to promote condensing. It has also been observed that recovery from setback can be extremely slow and, at times, not achieved. Recovery can be affected by the outdoor reset control, the differential setting on the boiler and over-sizing of the boiler itself. This guide is intended for designers and installers of hydronic heating systems interested in maximizing the overall system efficiency of condensing boilers when coupled with baseboard convectors. It is applicable to new and retrofit applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Controlled synthesis and thermal stability of hydroxyapatite hierarchical microstructures

Highlights: ► Hydroxyapatite hierarchical microstructures have been synthesized by a facile method. ► The morphology and size of the building units of 3D structures can be controlled. ► The hydroxyapatite with 3D structure is morphologically and structurally stable up to 800 °C. - Abstract: Hydroxyapatite (HAp) hierarchical microstructures with novel 3D morphology were prepared through a template- and surfactant-free hydrothermal homogeneous precipitation method. Field emission scanning electron microscopy (FESEM), high-resolution transmission electron microscopy (HRTEM), and X-ray diffraction (XRD) were used to characterize the morphology and composition of the synthesized products. Interestingly, the obtained HAp with 3D structure is composed of one-dimensional (1D) nanorods or two-dimensional (2D) nanoribbons, and the length and morphology of these building blocks can be controlled through controlling the pH of the reaction. The building blocks are single crystalline and have different preferential orientation growth under different pH conditions. At low pH values, octacalcium phosphate (OCP) phase formed first and then transformed into HAp phase due to the increased pH value caused by the decomposition of urea. The investigation on the thermal stability reveals that the prepared HAp hierarchical microstructures are morphologically and structurally stable up to 800 °C.

36 MATERIALS SCIENCE↗

The status of LILW disposal facility construction in Korea - 15158

In this paper, we discuss the experiences during the construction of the first LILW disposal facility in South Korea. In December 2005, the South Korean Government designated Gyeongju-city as a host city of Low- and Intermediate-Level Radioactive Waste (LILW) disposal site through local referendums held in regions whose local governments had applied to host disposal facility in accordance with the site selection procedures. The LILW disposal facility is being constructed in Bongil-ri, Yangbuk-myeon, Gyeongju. The official name of the disposal facility is called 'Wolsong Low and Intermediate Level Radioactive Waste Disposal Center (LILW Disposal Center)'. It can dispose of 800,000 drums of radioactive wastes in a site of 2,100,000 square meters. At the first stage, LILW repository of underground silo type with disposal capacity of 100,000 drums was completed by the end of June 2014. The Wolsong Low and Intermediate Level Radioactive Waste Disposal Center consists of surface facilities and underground facilities. The surface facilities include a receipt and inspection facility, an interim storage facility, a radioactive waste treatment building, and supporting facilities such as main control center, equipment and maintenance shop. The underground facilities consist of a construction tunnel for transport of construction equipment and materials, an operation tunnel for transport of radioactive waste, an access shaft for workers, and six silos for final disposal of radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Online data-enabled predictive control

We develop an online data-enabled predictive (ODeePC) control method for optimal control of unknown systems, building on the recently proposed DeePC (Coulson et al., 2019). Our proposed ODeePC method leverages a primal-dual algorithm with real-time measurement feedback to iteratively compute the corresponding real-time optimal control policy as system conditions change. The proposed ODeePC conceptual-wise resembles standard adaptive system identification and model predictive control (MPC), but it provides a new alternative for the standard methods. ODeePC is enabled by computationally efficient methods that exploit the special structure of the Hankel matrices in the context of DeePC with Fast Fourier Transform (FFT) and primal-dual algorithm We provide theoretical guarantees regarding the asymptotic behavior of ODeePC, and we demonstrate its performance through numerical examples.

97 MATHEMATICS AND COMPUTING↗

Decision Guides for Plug and Process Loads

This resource provides guidance for building owners to help them select the right control strategy for plug and process loads (PPLs) in their buildings. It includes guidance for multiple different building types and outline the costs, potential savings, complexities, and user friendliness of various control strategies and their applications to each building type.

Plug and Process Load, PPL, Commercial building, S↗

Co-Simulation of Electric Power Distribution Systems and Buildings including Ultra-Fast HVAC Models and Optimal DER Control

Smart homes and virtual power plant (VPP) controls are growing fields of research with potential for improved electric power grid operation. A novel testbed for the co-simulation of electric power distribution systems and distributed energy resources (DERs) is employed to evaluate VPP scenarios and propose an optimization procedure. DERs of specific interest include behind-the-meter (BTM) solar photovoltaic (PV) systems as well as heating, ventilation, and air-conditioning (HVAC) systems. The simulation of HVAC systems is enabled by a machine learning procedure that produces ultra-fast models for electric power and indoor temperature of associated buildings that are up to 133 times faster than typical white-box implementations. Hundreds of these models, each with different properties, are randomly populated into a modified IEEE 123-bus test system to represent a typical U.S. community. Advanced VPP controls are developed based on the Consumer Technology Association (CTA) 2045 standard to leverage HVAC systems as generalized energy storage (GES) such that BTM solar PV is better utilized locally and occurrences of distribution system power peaks are reduced, while also maintaining occupant thermal comfort. An optimization is performed to determine the best control settings for targeted peak power and total daily energy increase minimization with example peak load reductions of 25+%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geometric control of emergent antiferromagnetic order in coupled artificial spin ices

Artificial spin ices (ASIs) composed of coupled nanomagnets offer the possibility to create designer geometrical frustration and manipulate inter-nanomagnet interactions. In particular, by using a dimer motif consisting of two strongly coupled single-domain nano magnets as a building block, we can control and realize intriguing antiferromagnetic physical states in which the magnetic charge is not conserved. Here we create a dimer kagome ASI system within which the antiferromagnetic order is controlled by tuning lattice geometry. Different disordered antiferromagnetic phases and the inter-nanomagnet interactions are visualized directly in demagnetized lattices with different lattice parameters. Monte Carlo simulations establish that the collective ground state consists of disordered antiferromagnetic dimers across the lattice when the intra-dimer interaction is dominant. However, for lattices governed by intra-triad-unit interactions, the ground state exhibits a longrange spin-ordered state in which the vertex magnetic charge is uniform across all triads.

36 MATERIALS SCIENCE↗

Robust nonlinear control of vectored thrust aircraft

An interdisciplinary program in robust control for nonlinear systems with applications to a variety of engineering problems is outlined. Major emphasis will be placed on flight control, with both experimental and analytical studies. This program builds on recent new results in control theory for stability, stabilization, robust stability, robust performance, synthesis, and model reduction in a unified framework using Linear Fractional Transformations (LFT's), Linear Matrix Inequalities (LMI's), and the structured singular value micron. Most of these new advances have been accomplished by the Caltech controls group independently or in collaboration with researchers in other institutions. These recent results offer a new and remarkably unified framework for all aspects of robust control, but what is particularly important for this program is that they also have important implications for system identification and control of nonlinear systems. This combines well with Caltech's expertise in nonlinear control theory, both in geometric methods and methods for systems with constraints and saturations.

Doyle, John C.↗

Using EnergyPlus to Simulate the Dynamic Response of a Residential Building to Advanced Cooling Strategies: Preprint

This study demonstrates the ability of EnergyPlus to accurately model complex cooling strategies in a real home with a goal of shifting energy use off peak and realizing energy savings. The house was retrofitted through the Sacramento Municipal Utility District's (SMUD) deep energy retrofit demonstration program; field tests were operated by the National Renewable Energy Laboratory (NREL). Theexperimental data were collected as part of a larger study and are used here to validate simulation predictions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OCHRE: The Object-oriented, Controllable, High-resolution Residential Energy Model for Dynamic Integration Studies

Electrification and the growth of distributed energy resources (DERs), including flexible loads, are changing the energy landscape of electric distribution systems and creating new challenges and opportunities for electric utilities. Changes in demand profiles require improvements in distribution system load models, which have not historically accounted for device controllability or impacts on customer comfort. Although building modeling research has focused on these features, there is a need to incorporate them into distribution load models that include DERs and can be used to study grid-interactive buildings. In this paper, we present the Object-oriented, Controllable, High-resolution Residential Energy (OCHRE) model. OCHRE is a controllable thermal-electric residential energy model that captures building thermal dynamics, integrates grid-dependent electrical behavior, contains models for common DERs and end-use loads, and simulates at a time resolution down to 1 minute. It includes models for space heaters, air conditioners, water heaters, electric vehicles, photovoltaics, and batteries that are externally controllable and integrated in a co-simulation framework. Using a proposed zero energy ready community in Colorado, we co-simulate a distribution grid and 498 all-electric homes with a diverse set of efficiency levels and equipment properties. We show that controllable devices can reduce peak demand within a neighborhood by up to 73% during a critical peak period without sacrificing occupant comfort. We also demonstrate the importance of modeling load diversity at a high time resolution when quantifying power and voltage fluctuations across a distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A hybrid building thermal modeling approach for predicting temperatures in typical, detached, two-story houses

Within the residential building sector, the air-conditioning (AC) load is the main target for peak load shifting and reduction since it is the largest contributor to peak demand. By leveraging its power flexibility, residential AC is a good candidate to provide building demand response and peak load shifting. For realization of accurate and reliable control of AC loads, a building thermal model, which characterizes the properties of a building’s envelope and its thermal mass, is an essential component for accurate indoor temperature or cooling/heating demand prediction. Building thermal models include two types: “Forward” and “Data-Driven”. Due to time-saving and cost-effective characteristics, different data-driven models have been developed in a number of research studies. However, few developed models can predict temperatures in respective zones of a multiple-zone building with an open air path between zones e.g., an open stairwell connecting two floors of a home. In this research, a novel hybrid modeling approach is proposed to predict the average indoor air temperatures of both the upstairs and downstairs. This “hybrid” solution integrates both gray-box, i.e. RC model and black-box models. A developed RC model is used to predict the building mean temperature, and black-box model, in which the supervised machine learning algorithms are leveraged, is used to predict the temperature difference between the downstairs and upstairs. Compared with the measured data from a real house, the results obtained have acceptable/satisfactory accuracy. The method proposed in this study integrates the advantages of black-box and gray-box modeling. As a result, it can be used as a reliable alternative to predict the average temperatures in respective floors of typical detached two-story houses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MPCpy v0.1

This software can be used to develop and test Model Predictive Control (MPC) algorithms with simulated buildings or deploy MPC in real buildings. This includes the gathering of exogenous data, training of simplified models, and control optimization.

Blum, David↗

Daylighting Requirements in the National Building Energy Codes – They’re Here!

Requirements for the control of electric lighting in daylighted areas have historically been avoided in the national building energy codes. This is potentially a rich source of energy savings but as most lighting designers and architects know, daylighting design is not simple! The sheer complication of daylighting design makes crafting daylighting control requirements that could be applied generically in a national energy code a difficult task. However, that is currently changing. The Department of Energy’s (DOE) Building Energy Codes Program (BECP) managed by Pacific Northwest National Laboratory (PNNL) has been supporting the ANSI/ASHRAE/IESNA 90.1 committee in developing improvements to the 90.1 Standard. With subcontract support, the 90.1 Lighting Subcommittee has championed the incorporation of daylighting design and control requirements for the upcoming 2010 version of the nationally available ANSI/ASHRAE/IESNA Standard 90.1 for commercial building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving Energy Savings with Highly-Controlled Lighting in an Open-Plan Office

An installation in a Federal building tested the effectiveness of a highly-controlled, workstation-specific lighting retrofit. The study took place in an open-office area with 86 cubicles and low levels of daylight. Each cubicle was illuminated by a direct/indirectpendant luminaire with three 32 watt lamps, two dimmable DALI ballasts, and an occupancy sensor. A centralized control system programmed all three lamps to turn on and off according to occupancy on a workstation-by-workstation basis. Field measurements taken over the course of several monthsdemonstrated 40% lighting energy savings compared to a baseline without advanced controls that conforms to GSA's current retrofit standard. A photometric analysis found that the installation provided higher desktop light levels than the baseline, while an occupant survey found that occupants in general preferred the lighting system to thebaseline.Simple payback is fairly high; projects that can achieve lower installation costs and/or higher energy savings and those in which greenhouse gas reduction and occupant satisfaction are significant priorities provide the ideal setting for workstation-specific lighting retrofits.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗