Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Detecting False Data Injection Attacks in Smart Grids: A Semi-Supervised Deep Learning Approach

The dependence on advanced information and communication technology increases the vulnerability in smart grids under cyber-attacks. Recent research on unobservable false data injection attacks (FDIAs) reveals the high risk of secure system operation, since these attacks can bypass current bad data detection mechanisms. To mitigate this risk, this paper proposes a data-driven learning-based algorithm for detecting unobservable FDIAs in distribution systems. We use autoencoders for efficient dimension reduction and feature extraction of measurement datasets. Further, we integrate the autoencoders into an advanced generative adversarial network (GAN) framework, which successfully detects anomalies under FDIAs by capturing the unconformity between abnormal and secure measurements. Also, considering that the datasets collected from practical power systems are partially labeled due to expensive labeling costs and missing labels, the proposed method only requires a few labeled measurement data in addition to unlabeled data for training. Numerical simulations in three-phase unbalanced IEEE 13-bus and 123-bus distribution systems validate the detection accuracy and efficiency of this method.

97 MATHEMATICS AND COMPUTING↗

Joint Topology Identification and State Estimation in Unobservable Distribution Grids

Many distribution system operations (e.g., state estimation, control, fault detection/localization) rely on the assumption that the underlying topology is accurately defined. In general, topology identification is a challenging problem in distribution systems as these systems are unobservable with a very limited number of available measurements. In this paper, we tackle this problem by designing a compressive sensing framework that jointly estimates the systems states and network topology via an integrated mixed integer nonlinear program (MINLP) formulation. Here, two reformulations of the original MINLP problems are investigated. Firstly, in order to remove the nonlinearity in the MINLP formulation, a mixed integer linear programming (MILP) problem that employs auxiliary variables is derived. Furthermore, to achieve a faster solution, convex relaxation of the original formulation is derived. Finally, using a Markovian model for topology changes, prior information about system topology is used to improve topology identification particularly when a limited amount of measurements is available. Simulation results on IEEE 37-bus test feeder and IEEE 123-bus test feeder illustrate the efficiency and scalability of the proposed approaches from both state estimation and topology identification point of view (even with 30% of available data).

42 ENGINEERING↗

Deep Reinforcement Learning based Model-free On-line Dynamic Multi-Microgrid Formation to Enhance Resilience

Multi-microgrid formation (MMGF) is a promising solution for enhancing power system resilience. This paper proposes a new deep reinforcement learning (RL) based model-free on-line dynamic MMGF scheme. Additionally, the dynamic MMGF problem is formulated as a Markov decision process, and a complete deep RL framework is specially designed for the topologytransformable micro-grids. In order to reduce the large action space caused by flexible switch operations, a topology transformation method is proposed and an action-decoupling Q-value is applied. Then, a convolutional neural network (CNN) based multi-buffer double deep Q-network (CM-DDQN) is developed to further improve the learning ability of the original DQN method. The proposed deep RL method provides real-time computing to support the on-line dynamic MMGF scheme, and the scheme handles a long-term resilience enhancement problem using an adaptive on-line MMGF to defend changeable conditions. The effectiveness of the proposed method is validated using a 7-bus system and the IEEE 123-bus system. The results show strong learning ability, timely response for varying system conditions and convincing resilience enhancement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small-Signal Angle Stability-Oriented False Data Injection Cyber-Attacks on Power Systems

The small-signal angle stability (SSAS) of a power system is determined by the property of operation points. The widely applied false data injection (FDI) cyber-attack, however, is able to stealthily mislead the optimal power flow (OPF) and thus compromise operation points, leading to damages to the SSAS margin. Here, to provide insights for cyber defenders, this paper proposes and investigates a stealthy SSAS-oriented FDI cyber-attack focusing on two attacking purposes, i.e., the SSAS margin and operation cost, with higher priority on the former one. First, this paper establishes a novel bi-level model with an implicit SSAS constraint based on a structure preserving model to compromise operation points. Then, for the SSAS interarea mode in a typical two-area system, this paper formulates closed-form expressions of how the SSAS margin and operation cost behave with respect to stealthy injections. By comparison, for the SSAS local mode in general power systems, this paper proposes a moving target cyber-attack-based hierarchical solution algorithm. Simulation results on a two-area system, a Kundur 11 bus system, and a modified IEEE 14 bus system demonstrate the significant damaging effects of the proposed SSAS-oriented FDI cyber-attack and the conflict between the two attacking purposes.

Benders decomposition↗

Data-Driven Affinely Adjustable Robust Volt/VAr Control

Recent years have seen the increasing proliferation of distributed energy resources with intermittent power outputs, posing new challenges to the voltage management in distribution networks. To this end, this paper proposes a data-driven affinely adjustable robust Volt/VAr control (AARVVC) scheme, which modulates the smart inverter’s reactive power in an affine function of its active power, based on the voltage sensitivities with respect to real/reactive power injections. To achieve a fast and accurate estimation of voltage sensitivities, we propose a data-driven method based on deep neural network (DNN), together with a rule-based bus-selection process using the bidirectional search method. Our method only uses the operating statuses of selected buses as inputs to DNN, thus significantly improving the training efficiency and reducing information redundancy. Finally, a distributed consensus-based solution, based on the alternating direction method of multipliers (ADMM), for the AARVVC is applied to decide the inverter’s reactive power adjustment rule with respect to its active power. Only limited information exchange is required between each local agent and the central agent to obtain the slope of the reactive power adjustment rule, and there is no need for the central agent to solve any (sub)optimization problems. Finally, numerical results on the modified IEEE-123 bus system validate the effectiveness and superiority of the proposed data-driven AARVVC method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying the Economic and Grid Reliability Impacts of Improved Wind Power Forecasting

Wind power forecasting is an important tool in power system operations to address variability and uncertainty. Accurately doing so is important to reducing the occurrence and length of curtailment, enhancing market efficiency, and improving the operational reliability of the bulk power system. This research quantifies the value of wind power forecasting improvements in the IEEE 118-bus test system as modified to emulate the generation mixes of Midcontinent, California, and New England independent system operator balancing authority areas. To measure the economic value, a commercially available production cost modeling tool was used to simulate the multi-timescale unit commitment (UC) and economic dispatch process for calculating the cost savings and curtailment reductions. To measure the reliability improvements, an in-house tool, FESTIV, was used to calculate the system's area control error and the North American Electric Reliability Corporation Control Performance Standard 2. The approach allowed scientific reproducibility of results and cross-validation of the tools. A total of 270 scenarios were evaluated to accommodate the variation of three factors: generation mix, wind penetration level, and wind fore-casting improvements. The modified IEEE 118-bus systems utilized 1 year of data at multiple timescales, including the day-ahead UC, 4-hour-ahead UC, and 5-min real-time dispatch. The value of improved wind power forecasting was found to be strongly tied to the conventional generation mix, existence of energy storage devices, and the penetration level of wind energy. The simulation results demonstrate that wind power forecasting brings clear benefits to power system operations.

17 WIND ENERGY↗

Bi-Level Arbitrage Potential Evaluation for Grid-Scale Energy Storage Considering Wind Power and LMP Smoothing Effect

Our paper deals with extended-term energy storage (ES) arbitrage problems to maximize the annual revenue in deregulated power systems with high penetration wind power. The conventional ES arbitrage model takes the locational marginal prices (LMP) as an input and is unable to account for the impacts of ES operations on system LMPs. This paper proposes a bi-level ES arbitrage model, where the upper level maximizes the ES arbitrage revenue and the lower level simulates the market clearing process considering wind power and ES. The bi-level model is formulated as a mathematical program with equilibrium constraints (MPEC) and then recast into a mixed-integer linear programming (MILP) using strong duality theory. Wind power fluctuations are characterized by the GARCH forecast model and the forecast error is modeled by forecast-bin based Beta distributions. Case studies are performed on a modified PJM 5-bus system and an IEEE 118-bus system with a weekly time horizon over an annual term to show the validity of the proposed bi-level model. The results from the conventional model and the bi-level model are compared under different ES power and energy ratings, and also various load and wind penetration levels.

17 WIND ENERGY↗

Attention Enabled Multi-Agent DRL for Decentralized Volt-VAR Control of Active Distribution System Using PV Inverters and SVCs

This paper proposes attention enabled multi-agent deep reinforcement learning (MADRL) framework for active distribution network decentralized Volt-VAR control. Using the unsupervised clustering, the whole distribution system can be decomposed into several sub-networks according to the voltage and reactive power sensitivity relationships. Then, the distributed control problem of each sub-network is modeled as Markov games and solved by the improved MADRL algorithm, where each sub-network is modeled as an adaptive agent. An attention mechanism is developed to help each agent focus on specific information that is mostly related to the reward. All agents are centrally trained offline to learn the optimal coordinated Volt-VAR control strategy and executed in a decentralized manner to make online decisions with only local information. Compared with other distributed control approaches, the proposed method can effectively deal with uncertainties, achieve fast decision makings, and significantly reduce the communication requirements. Comparison results with model-based and other data-driven methods on IEEE 33-bus and 123-bus systems demonstrate the benefits of the proposed approach.

distribution network↗

Deep Reinforcement Scheduling of Energy Storage Systems for Real-time Voltage Regulation in Unbalanced LV Networks with High PV Penetration

The ever-growing higher penetration of distributed energy resources (DERs) in low-voltage (LV) distribution systems brings both opportunities and challenges to voltage support and regulation. This paper proposes a deep reinforcement learning (DRL)-based scheduling scheme of energy storage systems (ESSs) to mitigate system voltage deviations in unbalanced LV distribution networks. The ESS-based voltage regulation problem is formulated as a multi-stage quadratic stochastic program, with the objective of minimizing the expected total daily voltage regulation cost while satisfying operational constraints. While existing voltage regulation methods are mostly focused on onetime- step control, this paper explores a day-horizon systemwide voltage regulation problem. In other words, the size of action and state spaces are extremely high-dimensional and need to be delicately handled. Furthermore, in order to overcome the difficulty of modeling uncertainties and develop a realtime solution, a learn-to-schedule feedback control framework is proposed by adapting the problem to a model-free DRL setting. The proposed algorithm is tested on a customized 6-bus system and a modified IEEE 34-bus system. Simulation results validate the effectiveness and near-optimality of voltage regulation by ESS in comparison with a deterministic quadratic program solution.

Wang, Shengyi↗

Control Design and EMT Simulation Toward the Restoration of Faulted Wind-Dominant Grids

Present power engineers have been challenged to employ electromagnetic transient (EMT) simulations to study the restoration of wind-dominant grids. This paper addresses this hurdle by developing strategies to: (i) reliably control the dc-link voltage of grid-forming wind turbines with dc-coupled batteries, (ii) tune controllers to stably interconnect wind power plants into a grid under recovery, and (iii) autonomously make restoration decisions if transmission faults occur during restoration. These contributions are assessed via EMT simulations of wind-dominant versions of the WSCC 9-bus grid and a 22-bus power system. Furthermore, this paper is significant to address recommendations by the North American Electric Reliability Corporation.

17 WIND ENERGY↗

Hardware Design of Medium Voltage SiC-Based Modular Multilevel Converters for Grid-Tied Applications

This paper presents a design of a 10 kV silicon carbide (SiC) MOSFET based modular multilevel converter (MMC). The MMC functions as the interconnection between a 24 kV dc bus and a 13. SkV distribution grid. This paper focuses on the hardware design of the MMC and its submodules. The gate driver, auxiliary power supply and bus bur in submodules are major components that need to meet high dv/dt immunity and high insulation voltage requirements. The gate driver achieves over 200 kV/us common mode transient immunity (CMTI). Its associated auxiliary power supply is based on an on-board transformer with over 30 kV insulation capability and 1.4 pF barrier capacitance. The busbar achieves less than 11 kV/cm electric field in the air to avoid partial discharges. Validation tests of the MMC submodule were performed by double pulse tests at 5 kV and buck converter tests at3 kV, 52A (peak). Reliable operations were achieved in validation tests.

auxiliary power supply↗

Improving Trustworthiness of Data-Driven Power Grid Contingency Analysis With Bayesian Residual Graph Neural Networks

The evolving energy landscape requires novel tools to efficiently perform contingency analysis and reliability assessment of power grids, potentially in real-time. The high computational cost of traditional power flow solvers limits their applicability in practice. Machine learning (ML) surrogates such as deep neural networks (NNs) accelerate power flow solvers computations, enabling high-order contingency analysis and real-time decision-making by learning highly nonlinear functions and integrating grid topology via graph architectures. However, (graph) NNs lack predictive power away from training data and do not provide predictive confidence estimates. Here, we present a Bayesian residual graph NN that integrates knowledge from low-fidelity data via residual training and embeds granular quantification of uncertainties, improving trustworthiness critical for high-consequence decision-making. Applying Bayesian concepts to NNs is challenging due to the high-dimensionality of both the parameter space, complicating derivation of a meaningful prior, and the output space in large grid systems, requiring enhanced techniques to assess the predicted high-dimensional uncertainties. Our contributions include: (1) Deriving a prior for fully connected and graph NNs that leverages low-fidelity data to guide mean predictions and appropriately control prior predictive uncertainty. (2) Integrating this prior within an ensembling with anchoring scheme for efficient approximate posterior inference. (3) Deriving enhanced metrics to assess accuracy of both the mean and uncertainty predictions in high dimensions, appropriately accounting for correlations propagated through graph layers. The resulting Bayesian residual graph NN is tested on a contingency analysis task for 14-bus and 118-bus grids.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Estimated dose rates to members of the public from external exposure to patients with {sup 131}I thyroid treatment

Purpose: Estimated dose rates that may result from exposure to patients who had been administered iodine-131 ({sup 131}I) as part of medical therapy were calculated. These effective dose rate estimates were compared with simplified assumptions under United States Nuclear Regulatory Commission Regulatory Guide 8.39, which does not consider body tissue attenuation nor time-dependent redistribution and excretion of the administered {sup 131}I. Methods: Dose rates were estimated for members of the public potentially exposed to external irradiation from patients recently treated with {sup 131}I. Tissue attenuation and iodine biokinetics were considered in the patient in a larger comprehensive effort to improve external dose rate estimates. The external dose rate estimates are based on Monte Carlo simulations using the Phantom with Movable Arms and Legs (PIMAL), previously developed by Oak Ridge National Laboratory and the United States Nuclear Regulatory Commission. PIMAL was employed to model the relative positions of the {sup 131}I patient and members of the public in three exposure scenarios: (1) traveling on a bus in a total of six seated or standing permutations, (2) two nursing home cases where a caregiver is seated at 30 cm from the patient’s bedside and a nursing home resident seated 250 cm away from the patient in an adjacent bed, and (3) two hotel cases where the patient and a guest are in adjacent rooms with beds on opposite sides of the common wall, with the patient and guest both in bed and either seated back-to-back or lying head to head. The biokinetic model predictions of the retention and distribution of {sup 131}I in the patient assumed a single voiding of urinary bladder contents that occurred during the trip at 2, 4, or 8 h after {sup 131}I administration for the public transportation cases, continuous first-order voiding for the nursing home cases, and regular periodic voiding at 4, 8, or 12 h after administration for the hotel room cases. Organ specific activities of {sup 131}I in the thyroid, bladder, and combined remaining tissues were calculated as a function of time after administration. Exposures to members of the public were considered for {sup 131}I patients with normal thyroid uptake (peak thyroid uptake of ∼27% of administered {sup 131}I), differentiated thyroid cancer (DTC, 5% uptake), and hyperthyroidism (80% uptake). Results: The scenario with the patient seated behind the member of the public yielded the highest dose rate estimate of seated public transportation exposure cases. The dose rate to the adjacent room guest was highest for the exposure scenario in which the hotel guest and patient are seated by a factor of ∼4 for the normal and differentiated thyroid cancer uptake cases and by a factor of ∼3 for the hyperthyroid case. Conclusions: It was determined that for all modeled cases, the DTC case yielded the lowest external dose rates, whereas the hyperthyroid case yielded the highest dose rates. In estimating external dose to members of the public from patients with {sup 131}I therapy, consideration must be given to (patient- and case-specific) administered {sup 131}I activities and duration of exposure for a more complete estimate. The method implemented here included a detailed calculation model, which provides a means to determine dose rate estimates for a range of scenarios. The method was demonstrated for variations of three scenarios, showing how dose rates are expected to vary with uptake, voiding pattern, and patient location.

60 APPLIED LIFE SCIENCES↗

NANDFlashSim: High-Fidelity, Microarchitecture-Aware NAND Flash Memory Simulation [NANDFlashSim: Intrinsic Latency Variation Aware NAND Flash Memory System Modeling and Simulation at Microarchitecture Level]

As the popularity of NAND flash expands in arenas from embedded systems to high-performance computing, a high-fidelity understanding of its specific properties becomes increasingly important. Further, with the increasing trend toward multiple-die, multiple-plane architectures and high-speed interfaces, flash memory systems are expected to continue to scale and cheapen, resulting in their broader proliferation. However, when designing NAND-based devices, making decisions about the optimal system configuration is nontrivial, because flash is sensitive to a number of parameters and suffers from inherent latency variations, and no available tools suffice for studying these nuances. The parameters include the architectures, such as multidie and multiplane, diverse node technologies, bit densities, and cell reliabilities. Therefore, we introduce NANDFlashSim, a high-fidelity, latency-variation-aware, and highly configurable NAND-flash simulator, which implements a detailed timing model for 16 state-of-the-art NAND operations. Using NANDFlashSim, we notably discover the following. First, regardless of the operation, reads fail to leverage internal parallelism. Second, MLC provides lower I/O bus contention than SLC, but contention becomes a serious problem as the number of dies increases. Third, many-die architectures outperform many-plane architectures for disk-friendly workloads. Lastly, employing a high-performance I/O bus or an increased page size does not enhance energy savings.

97 MATHEMATICS AND COMPUTING↗

Home Energy Management System - VOLTTRON Integration

In most Home Energy Management Systems (HEMS) available in the market, different devices running different communication protocols cannot interact with each other and exchange information. As a result of this integration, the information about different devices running different communication protocol can be accessible by other agents and devices running on VOLTTRON platform. The integration process can be used by any HEMS available in the market regardless of the programming language they use. If the existing HEMS provides an Application Programming Interface (API) based on the RESTFul architecture, that API can be used for integration. Our candidate HEMS in this project is home-assistant (Hass). An agent is implemented which can communicate with the Hass API and receives information about the devices loaded on the API. The agent publishes the information it receives on the VOLTTRON message bus so other agents can have access to this information. On the other side, for each type of devices, an agent is implemented such as Climate Agent, Lock Agent, Switch Agent, Light Agent, etc. Each of these agents is subscribed to the messages published on the message bus about their associated devices. These agents can also change the status of the devices by sending appropriate service calls to the API. Other agents and services on the platform can also access this information and coordinate their decision-making process based on this information.

Zandi, Helia↗

GHOST (Grid Hardware Open Source Testbed) [SWR-18-32]

The software was developed for the purpose of Microgrid Controller Procurement where multiple Microgrid Controller vendors were competing to prove the best performance. Each microgrid controller was connected to Real-Time Simulator (Opal-RT) where the Real-Time model of microgrid was simulated. Microgrid controllers were able to control most of the assets in the model. To be able to fairly compare controller's performance each controller was evaluated using exactly the same model, with the same initial conditions and exactly the same test sequence. The microgrid evaluation test sequence lasted 100 minutes and consist of various grid disturbances to which a microgrid controller must respond. The microgrid and power system will experience multiple types of disturbances while performing dispatch functions. Many functions are tested in grid-connected and islanded modes such as unexpended failures of generators, energy storage trip events, and large load fluctuations. The test sequence focuses on fault scenarios that cause the highest short-circuit fault current contribution; force a swing bus or generator capable of being a swing bus offline; cause the most reconfigurations; and cause conflicting objectives for the microgrid controller. During the test sequence execution multiple datapoints are being recorded and stored. During data postprocessing key performance parameters are extracted allowing quantitative comparison of performance on multiple aspects including: resiliency, fuel utilization, grid interconnection, ancillary services and power quality and eventually after summing all key performance parameters by comparing the overall result. To be able to perform such testing multiple tools had to be developed included in this repository including: - Real time model of microgrid (Urban-Banshee, Remote-smaller model) - Test sequence configuration tools - Test execution real-time scripts - Post processing scripts - Human Machine Interface software

Koralewicz, Przemyslaw↗

The Microgrid Performance Reliability Model (MPRM) v. 1.50 Beta

The MPRM is a simulation code that is used to statistically quantify the performance and reliability of a microgrid operating in islanded mode. Performance can be expressed in terms of fuel efficiency, renewable penetration, and other operational characteristics of the grid. Reliability can be expressed in terms of frequency and magnitude of load loss on a tier-by-tier, bus-by-bus basis or on an

Eddy, John↗