Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Evaluating Probabilistic Deep Learning Methods for Uncertainty Quantification of Precipitation Bias Correction

Climate models often exhibit biases in their precipitation predictions, particularly underestimating high-intensity events and overestimating low precipitation. Deep learning approaches offer promising solutions, but their epistemic uncertainty associated with a deep learning–based bias correction method has not previously been quantified for reliable downstream climate impact studies. While methods for capturing the epistemic uncertainty in deep learning frameworks exist, there is currently no consensus on the best method. In this work, we compare three uncertainty quantification (UQ) methods—Deep Ensembles (DEns), Monte Carlo Dropout (MCD), and Flipout—by assessing the reliability of their uncertainty estimates using standard measures such as sharpness and calibration. These UQ methods are applied to an existing deep learning precipitation bias correction model known as UFNet: a coupled U-Net and fully connected neural network. The methods utilized to assess the models’ uncertainties are 1) calibration, which ensures that the expected probabilities of the model align with reality and 2) sharpness, which is a measure of the precision of the model’s probabilistic predictions. Of the three UQ methods evaluated, the DEns and MCD methods demonstrated the best-calibrated performance (expected calibration error of 0.36 and 0.35, respectively), compared to Flipout (0.58). In contrast, Flipout had the sharpest predictions and the highest metric performance in bias correcting precipitation—especially for higher-order moments such as kurtosis with a spatial correlation of 72% compared to 32% and 55% spatial correlation for DEns and MCD, respectively. Of the three UQ methods, MCD was found to be the most suitable method for UQ purposes based on its calibration, sharpness, and computational requirements.

Bayesian methods↗

Water Quality Projects Summary for the Mid-Columbia and Cumberland River Systems

Scheduling and operational control of hydropower systems is accompanied with a keen awareness of the management of water use, environmental effects, and policy, especially within the context of strict water rights policy and generation maximization. This is a multi-objective problem for many hydropower systems, including the Cumberland and Mid-Columbia river systems. Though each of these two systems have distinct operational philosophies, hydrologic characteristics, and system dynamics, they both share a responsibility to effectively manage hydropower and the environment, which requires state-of-the art improvements in the approaches and applications for water quality modeling. The Department of Energy and Oak Ridge National Laboratory have developed tools for total dissolved gas (TDG) prediction on the Mid-Columbia River and a decision-support system used for hydropower generation and environmental optimization on the Cumberland River. In conjunction with IIHR - Hydroscience & Engineering, The University of Iowa and University of Colorado s Center for Advanced Decision Support for Water and Environmental Systems (CADSWES), ORNL has managed the development of a TDG predictive methodology at seven dams along the Mid-Columbia River and has enabled the ability to utilize this methodology for optimization of operations at these projects with the commercially available software package Riverware. ORNL has also managed the collaboration with Vanderbilt University and Lipscomb University to develop a state-of-the art method for reducing high-fidelity water quality modeling results into surrogate models which can be used effectively within the context of optimization efforts to maximize generation for a reservoir system based on environmental and policy constraints. The novel contribution of these efforts is the ability to predict water quality conditions with simplified methodologies at the same level of accuracy as more complex and resource intensive computing methods. These efforts were designed to incorporate well into existing hydropower and reservoir system scheduling models, with runtimes that are comparable to existing software tools. In addition, the transferability of these tools to assess other systems is enhanced due the use of simplistic and easily attainable values for inputs, straight-forward calibration of predictive equation coefficients, and standardized comparison of traditionally familiar outputs.

54 ENVIRONMENTAL SCIENCES↗

Radiological Survey and Release Report for 9404-17 & 9404-18

The data quality objective (DQO) process and a graded approach are integrated within the MARSSIM process and within the plan to assure defensible data with cost effectiveness. Surveys were performed by trained Radiological Control Technicians (RCTs) following standard, written procedures and using properly calibrated instruments, sensitive to the potential contaminants. Instrumentation identification and the name of the technicians performing the survey can be found in the referenced radiological surveys.

54 ENVIRONMENTAL SCIENCES↗

R -Matrix Analysis and Statistical Properties of Dysprosium Isotopes in the Neutron Energy Ranges Up To A Few Kev

In support of the Nuclear Criticality Safety Program, a set of evaluated resonance parameters was generated for seven dysprosium isotopes in the neutron energy range from thermal up to a few keV. The evaluation methodology used the Reich-Moore approximation to fit, with the R-matrix code SAMMY, the high-resolution capture and transmission measurements on natural and enriched samples recently performed at the Rensselaer Polytechnic Institute Gaerttner LINear ACcelerator facility. Additional transmission data measured on enriched samples by Liou at the Columbia University Nevis synchrocyclotron in the mid-seventies were used to gauge the neutron widths above 15 eV. Thermal constants such as absorption and (in)coherent scattering cross sections and corresponding scattering lengths were calibrated to the National Institute of Standards and Technology’s compilation except for 161,164 Dy isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Strained Superlattice photocathode development using CBE and MBE

High polarization electron beams for accelerators are generated using strained superlattice GaAs-based photocathodes. A collaboration of researchers at University of California Santa Barbara and Jefferson Lab has been investigating growth of SSL photocathodes using either chemical- or molecular-beam epitaxy (CBE or MBE) to re-establish a source of high polarization photocathode material. While calibrating growth parameters for the now standard GaAs/GaAsP strained superlattice structure, the UCSB personnel encountered the drawbacks of growing structures with phosphorus in a MBE or CBE system, including high vapor pressure byproducts, phosphorus contamination in both the GaAs layer and all subsequent materials grown in that chamber, and highly flammable and toxic chamber residues. For these reasons, the UCSB team began additionally investigating strained superlattices of InAlGaAs/AlGaAs, which has been successfully demonstrated in the literature1, to be a high QE, high polarization photocathode material. For GaAs/GaAsP, varying phosphorus content affects both the band gap and polarization. However for InAlGaAs/AlGaAs, In and Al content can be varied independently and allows optimization of both polarization and bandgap. Several variations on InAlGaAs/AlGaAs superlattice photocathodes, including those with distributed Bragg reflector (DBR) structures to enhance QE, have been grown at UCSB and sent to Jefferson Lab for testing. The initial results are quite promising, with polarization over 80% and QE about 0.3%, and ongoing test results will be presented.

Stutzman, Marcy↗

Improved cavity-type absolute total-radiation radiometer

Conical cavity-type absolute radiometer measures the intensity of radiant energy to an accuracy of one to two percent in a vacuum of ten to the minus fifth torr or lower. There is a uniform response over the ultraviolet, visible, and infrared range, and it requires no calibration or comparison with a radiation standard.

Kendall, J. M., Sr.↗

Detection of fatigue cracks by nondestructive testing methods

The effectiveness was assessed of various NDT methods to detect small tight cracks by randomly introducing fatigue cracks into aluminum sheets. The study included optimizing NDT methods calibrating NDT equipment with fatigue cracked standards, and evaluating a number of cracked specimens by the optimized NDT methods. The evaluations were conducted by highly trained personnel, provided with detailed procedures, in order to minimize the effects of human variability. These personnel performed the NDT on the test specimens without knowledge of the flaw locations and reported on the flaws detected. The performance of these tests was measured by comparing the flaws detected against the flaws present. The principal NDT methods utilized were radiographic, ultrasonic, penetrant, and eddy current. Holographic interferometry, acoustic emission monitoring, and replication methods were also applied on a reduced number of specimens. Generally, the best performance was shown by eddy current, ultrasonic, penetrant and holographic tests. Etching provided no measurable improvement, while proof loading improved flaw detectability. Data are shown that quantify the performances of the NDT methods applied.

Anderson, R. T.↗

Soil, water, and vegetation conditions in south Texas

The author has identified the following significant results. Software development for a computer-aided crop and soil survey system is nearing completion. Computer-aided variety classification accuracies using LANDSAT-1 MSS data for a 600 hectare citrus farm were 83% for Redblush grapefruit and 91% for oranges. These accuracies indicate that there is good potential for computer-aided inventories of grapefruit and orange citrus orchards with LANDSAT-type MSS data. Mean digital values of clouds differed statistically from those for crop, soil, and water entities, and those for cloud shadows were enough lower than sunlit crop and soil to be distinguishable. The standard errors of estimate for the calibration of computer compatible tape coordinate system (pixel and record) to earth coordinate system (longitude and latitude) for 6 LANDSAT scenes ranged from 0.72 to 1.50 pixels and from 0.58 to 1.75 records.

Wiegand, C. L.↗

Ergometer

The bicycle ergometer was designed for use in experiments M171 and M093 and for use in optional exercise by the crewmen. The ergometer allows a crewman to exercise in zero-gravity using either his hands or his feet. It provides a precisely calibrated and, if needed, a programmable standard of work rate for the crewman. The ergometer operates in any of three selectable modes. The set heart rate mode varies the ergometer work rate, as necessary, to achieve and maintain a preselected heart rate. The sequenced heart rate mode is similar to the set heart rate mode except that the heart rate is programmable through five preset levels with a period of time for each level. The set work rate mode delivers a preset work load to the subject.

Lem, J. D.↗

Theoretical simulation of solar spectra in the middle ultraviolet and visible for atmospheric trace constituent measurements

Two balloon flights reaching float altitudes of approximately 30 and 40 km respectively, were used to obtain scans of the ultraviolet and visible solar spectra. Both flights covered the UV (2800-3500A) at approximately 0.3A resolution and the visible at approximately 0.6A. Numerous scans were obtained during ascent and from float for both flights. All spectral scans obtained at float, from high sun to low sun, were calibrated in wavelength by using several standard solar spectra for line position references. Comparisons of low sun scans and high sun scans show significant atmospheric continuum extinction and have the potential of being used to identify atmospheric lines superimposed on the attenuated solar spectrum. The resolution was mathematically degraded to approximately 5A to better see the broad band atmospheric extinction. This low resolution is also appropriate for the available low resolution absorption coefficients of NO2 and O3, allowing the identification of NO2 and O3 features on the sunset spectra.

Goldman, A.↗

Comparison of calculated and altitude-facility-measured thrust and airflow of two prototype F100 turbofan engines

A comparison is made of the facility performance data for the two engines with an engine performance model, and it provides corrections that can be applied to the model so that it represents the test engines accurately over the flight envelope. Test conditions ranged from Mach numbers of 0.80 to 2.00 and altitudes from 4020 meters to 15,240 meters. Two distortion screens were used to determine the effect of distortion on airflow. Reynolds number effects were also determined. Engine hysteresis is documented, as is an attempt to determine engine degradation. The calibrated engine model had a twice standard deviation accuracy of approximately 1.24 percent for corrected airflow and 2.38 percent for gross thrust.

Kurtenbach, F. J.↗

The measurement of solar spectral irradiances at wavelengths between 40 and 4000 A

Two 1/8-meter Ebert-Fastie spectrometers were refurbished and upgraded in order to measure the solar spectral irradiances between 1160 A and 3100 A. An evacuated 1/4-meter normal-incidence spectrometer was also fabricated for spectral irradiance measurements over the wavelength range from 1250 A to 250 A. Procedures were developed for the calibration of all three instruments utilizing standards at the National Bureau of Standards. The two 1/8-meter spectrometers were flown to measure the solar spectral irradiances near solar maximum on two different dates. Data from these flights were analyzed. The performance of the spectrometers, and the results of an analysis of the variabilities of the solar spectral irradiances over the solar cycles 20 and 21 are discussed.

Timothy, J. G.↗

Carbon abundance measurements in oceanic basalts - The need for a consensus

Large systematic discrepancies currently exist among the carbon data reported for oceanic basalts by different laboratories. These discrepancies are likely attributable both to nonuniform criteria for the removal of carbon contamination from the samples, and to systematic errors in analytical procedures. In order to solve these problems, investigators must agree upon effective criteria for the removal of carbon contamination, and they must create an accurately calibrated set of basaltic glass carbon standards.

Des Marais, D. J.↗

The Berkeley extreme ultraviolet calibration facility

The vacuum calibration facilities of the Space Sciences Laboratory, University of California at Berkeley are designed for the calibration and testing of EUV and FUV spaceborne instrumentation (spectral range 44-2500 A). The facility includes one large cylindrical vacuum chamber (3 x 5 m) containing two EUV collimators, and it is equipped with a 4-axis manipulator of angular-control resolution 1 arcsec for payloads weighing up to 500 kg. In addition, two smaller cylindrical chambers, each 0.9 x 1.2 m, are available for vacuum and thermal testing of UV detectors, filters, and space electronics hardware. All three chambers open into class-10,000 clean rooms, and all calibrations are referred to NBS secondary standards.

Welsh, Barry Y.↗

Data quality analysis at the National Transonic Facility

The data quality analysis program that was developed at Langley Research Center's National Transonic Facility is described. The program provides a computer driven systematic analysis of data taken during calibrations of the high speed digital data acquisition system. Five distinct checks that are performed on the calibration data are outlined. The five checks are for non-linearity, noise, short term drift, long term drift, and the proper functioning of the calibrator. The program has established a standard set of evaluation guidelines.

Stewart, Pamela N.↗