Search NASA⌕ Search

SEARCH · Search NASA

Results for “CSP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

A first principles framework to predict the transient performance of latent heat thermal energy storage

Thermal energy storage (TES) is increasingly recognized as an essential component of efficient Combined Heat and Power (CHP), Concentrated Solar Power (CSP), Heating Ventilation and Air Conditioning (HVAC), and refrigeration as it reduces peak demand while helping to manage intermittent availability of energy (e.g., from solar or wind). Latent Heat Thermal Energy Storage (LHTES) is a viable option because of its high energy storage density. Parametric analysis of LHTES in terms of dimensionless numbers is highly desired as a tool to model LHTES systems. One approach is to develop a model equation so as to minimize the error between the model and data obtained from experiments or simulations. While this approach can produce an accurate correlation applicable within the range of data used for its creation, it does not provide physical understanding of the rate-limiting process controlling the transient behavior of the device. In this paper we present an alternative approach whereby the potential rate-limiting processes are identified from first principles and then the key process is determined as a function of time as a LHTES device is charged. For example, in a simple geometry, the melt-fraction can be expected to vary linearly in time if the heat transfer rate is limited by natural convection of the phase changing material and we show it scales with the PCM Grashof number as $Gr^1_p$ and PCM Prandtl number as $Pr_p^{(1/3)}$. On the other hand, if surface area of solid PCM limits the heat transfer rate, the melt fraction increases asymptotically to reach full melting. The existence of these linear and asymptotic regions and the $Gr^1_pP r^{1/3}_p$ shape of the melt fraction curve is verified using our database of 64 simulations. Of practical importance in designing LHTES devices is the melt fraction at which the heat transfer rate ceases to be limited by convection, after which the heat storage rate deteriorates. For our geometry, this is found to be about 90%. This test case of our methodology shows the value of our approach, that predicting heat storage rate based on the rate-limiting physical phenomenon as a function of time is an effective approach to modeling LHTES devices.

25 ENERGY STORAGE↗

Effect of phase composition of calcium silicate phosphate component on properties of brushite based composite cements

The composite cement mixtures were prepared by mixing brushite (B) with, the amorphous hydrated calcium silicate phosphate (CSPH) or annealed calcium silicate phosphate (CSP composed of Si-saturated hydroxyapatite, wollastonite and silica) phases and water as liquid component. The contents of the silicate-phosphate phase in composites were 10.30 and 50 wt%. The significant effect of both the Ca/P ratio and different solubility of calcium silicate phosphate component in starting cement systems on setting time and phase composition of the final composite cements was demonstrated. The compressive strength of the set cements increased with the filler addition and the highest value (~ 48 MPa) exhibited the 50CSP/B cement composite. The final setting times of the composite cements decreased with the CSPH addition from about 25 to 17 min in 50CSHP/B and setting time of CSP/B composites was around 30 min. The higher content of silica in cements caused the precipitation of fine hydroxyapatite particles in the form of nanoneedles or thin plates perpendicularly oriented to sample surface. The analysis of in vitro cement cytotoxicity demonstrated the strong reduction in cytotoxicity of 10CSPH/B composite with time of cultivation (a low cytotoxicity after 9 days of culture) contrary to cements with higher calcium silicate-phosphate content. These results were attributed to the different surface topography of composite substrates and possible stimulation of cell proliferation by the slow continuously release of ions from 10CSPH/B cement. - Highlights: • Ca/P ratio and solubility of calcium silicate-phosphate components affect the self-setting properties of cements. • Strong relationship between the composite in vitro cytotoxicity and surface microtopography was demonstrated. • Plate-like morphology of coarser particles allowed cells to better adhere and proliferate as compared with nanoneedles.

36 MATERIALS SCIENCE↗

One piece ceramic heat exchanger for concentrating solar power electric plants

Using additive manufacturing techniques, a ceramic heat exchanger was optimized for a concentrating solar power (CSP) electric power plant with a corrosive molten salt at atmospheric pressure as the solar field heat transfer fluid and supercritical carbon dioxide at 200 bar as the power block fluid. Temperatures ranged from 750 °C to 540 °C. The plant heat exchanger was optimized for heat transfer and stress using 1 m³ modules arranged in parallel. Heat transfer was optimized using COMSOL Multiphysics software resulting in a unique semi-elliptical cross section for the fluid flow channels in a counter-flow configuration. Counter-flow was made possible through additive manufacturing of the fluid headers as part of each modular heat exchanger thus producing the entire module as a single piece and minimizing cost. Using reasonable parametric values, a heat exchanger module was optimized to 0.5 MW/m³, and a section of it was manufactured including the fluid headers. Here, parametric studies showed the potential for a module to reach 3.5 MW/m³.

14 SOLAR ENERGY↗

Solar energy dust and soiling R&D progress: Literature review update for 2016

The objective of this literature review and survey is to provide a compilation and assessment of recent published reports for solar-electric device soiling R&D, to extend and update the compendium covering 2012-2015 we published last year. This review provides a comprehensive listing of the publications with references for 2016 - with some preliminary 2017 publications that have appeared at the time of this writing. Photovoltaics (PV) and concentrating solar (thermal) power (CSP) technologies are covered. To guide the reader, tabulated information on the investigative focus of the studies, the location, the duration (if pertinent), the solar-device type, key findings and other useful information within the report is presented.

14 SOLAR ENERGY↗

Electrodeposited nickel coatings for exceptional corrosion mitigation in industrial grade molten chloride salts for concentrating solar power

Molten chloride salt eutectics are attractive candidates for use as thermal energy storage media and heat transfer fluids in generation-three concentrating solar thermal power (Gen3 CSP) plants. However, corrosion of alloys in molten chloride salts, especially at high temperatures, is an extremely challenging problem that studies focus on lower temperatures, shorter durations, or analytical grade, and high-purity, salts. To date, there has been no study on corrosion or corrosion mitigation in an industrial-grade salt at a high temperature such as 750 °C. To alleviate this knowledge gap, the study presents new multiscale fractal-textured Ni coatings on various alloy surfaces for effective corrosion mitigation at 750 °C in molten chloride salts. Using the electrodeposition method, durable double-layer textured coatings were formed on stainless steel alloys (SS316, SS310, and SS347) and In800H. The corrosion performance of the coatings is investigated in both analytical-grade purity and, for the first time, practically relevant industrial-grade chloride salts. Ni-coated ferrous alloys showed an exceptionally reduced corrosion rate in the range of 350–480 μm/y in analytical-grade salts, and between 450 and 490 μm/y in purified industrial-grade salts at 750 °C. Ni coatings on ferrous alloys reduced corrosion rates by as much as 70% compared to uncoated surfaces and were comparable to the expensive Ha230 alloy with a high Ni content. As a result, by the use of innovative fractal corrosion mitigation coatings, for the first time, low-cost structural alloys are rendered viable for use with industrial-grade chloride salts, which is profoundly beneficial in practical systems.

14 SOLAR ENERGY↗

Tin doping in spray pyrolysed indium sulfide thin films for solar cell applications

This paper presents studies carried out on tin-doped indium sulfide films prepared using Chemical Spray Pyrolysis (CSP) technique. Effect of both in-situ and ex-situ doping were analyzed. Ex-situ doping was done by thermal diffusion, which was realized by annealing Sn/In{sub 2}S{sub 3} bilayer films. In-situ doping was accomplished by introducing Sn into the spray solution by using SnCl{sub 4}.5H{sub 2}O. Interestingly, it was noted that by ex-situ doping, conductivity of the sample enhanced considerably without affecting any of the physical properties such as crystallinity or band gap. Analysis also showed that higher percentage of doping resulted in samples with low crystallinity and negative photosensitivity. In-situ doping resulted in amorphous films. In contrast to ex-situ doping, 'in- situ doping' resulted in widening of optical band gap through oxygen incorporation; also it gave highly photosensitive films. (author)

14 SOLAR ENERGY↗

Energy yield loss caused by dust deposition on photovoltaic panels

Large-scale solar plants are generally located in semi-arid and desert lands where abundant sunlight is available for solar energy con- version. These plants, however, suffer from two major environmental degradation factors: high ambient temperature and high concen- tration of atmospheric dust. Degradation of solar collectors’ performance caused by soiling results in a considerable loss of energy yield in all solar plants of the world. Dust and other particulate accumulation on solar collectors causes transmission loss. This is true with respect to transmission losses in photovoltaic (PV) and concentrated photovoltaic (CPV) systems, and for reflection losses in concen- trated solar power (CSP) systems. We present here a brief review of the energy yield losses caused by dust deposition on solar collectors, with particular emphasis on flat-panel photovoltaic (PV) systems. The review includes some of the major studies reported on energy-yield losses on solar plants in operation in several regions of the world. In addition, laboratory-soiling studies are also included. We report on degradation in the performance of solar plants based on the type of solar collectors, geographical location, local climate, and exposure period of the collectors absent any manual cleaning. An analysis of the advantages of cleaning processes that include natural, manual, automatic, and passive methods is presented. Our objective is to provide solar plant designers with a database for predicting anticipated soiling losses in different parts of the world, and for assessing effective cleaning methods for restoring a system’s energy yield.

14 SOLAR ENERGY↗

Diverging polygon-based modeling (DPBM) of concentrated solar flux distributions

This paper presents an efficient and robust methodology for modeling concentrated solar flux distributions. Compared to ray tracing methods, which provide high accuracy but can be computationally intensive, this approach makes a number of simplifying assumptions in order to reduce complexity by modeling incident and reflected flux as a series of simple geometric diverging polygons, then applying shading and blocking effects. A reduction in processing time (as compared to ray tracing) allows for evaluating and visualizing numerous combinations of engineering and operational variables (easily exceeding 106 unique iterations) to ascertain instantaneous, transient, and annual system performance. The method is demonstrated on a linear Fresnel reflector array and a number of variable iteration examples presented. While some precision is sacrificed for computational speed, flux distributions were compared to ray tracing (SolTrace) and average concentration ratio generally found to agree within ~3%. Furthermore, this method presents a quick and very flexible coarse adjust method for concentrated solar power (CSP) field design, and can be used to both rapidly gain an understanding of system performance as well as to narrow variable constraint windows for follow-on high accuracy system optimization.

14 SOLAR ENERGY↗

Proposal and evaluation of subordinate standard solar irradiance spectra for applications in solar energy systems

Reference solar irradiance spectra are needed to specify key parameters of solar technologies such as photovoltaic cell efficiency, in a comparable way. The IEC 60904-3 and ASTM G173 standards present such spectra for Direct Normal Irradiance (DNI) and Global Tilted Irradiance (GTI) on a 37 degrees tilted sun-facing surface for one set of clear-sky conditions with an air mass of 1.5 and low aerosol content. The IEC/G173 standard spectra are the widely accepted references for these purposes. Hence, the authors support the future replacement of the outdated ISO 9845 spectra with the IEC spectra within the ongoing update of this ISO standard. The use of a single reference spectrum per component of irradiance is important for clarity when comparing and rating solar devices such as PV cells. However, at some locations the average spectra can differ strongly from those defined in the IEC/G173 standards due to widely different atmospheric conditions and collector tilt angles. Therefore, additional subordinate standard spectra for other atmospheric conditions and tilt angles are of interest for a rough comparison of product performance under representative field conditions, in addition to using the main standard spectrum for product certification under standard test conditions. This simplifies the product selection for solar power systems when a fully-detailed performance analysis is not feasible (e.g. small installations). Also, the effort for a detailed yield analyses can be reduced by decreasing the number of initial product options. After appropriate testing, this contribution suggests a number of additional spectra related to eight sets of atmospheric conditions and tilt angles that are currently considered within ASTM and ISO working groups. The additional spectra, called subordinate standard spectra, are motivated by significant spectral mismatches compared to the IEC/G173 spectra (up to 6.5%, for PV at 37 degrees tilt and 10-15% for CPV). These mismatches correspond to potential accuracy improvements for a quick estimation of the average efficiency by applying the appropriate subordinate standard spectrum instead of the IEC/G173 spectra. The applicability of these spectra for PV performance analyses is confirmed at five test sites, for which subordinate spectra could be intuitively selected based on the average atmospheric aerosol optical depth (AOD) and precipitable water vapor at those locations. The development of subordinate standard spectra for DNI and concentrating solar power (CSP) and concentrating PV (CPV) is also considered. However, it is found that many more sets of atmospheric conditions would be required to allow the intuitive selection of DNI spectra for the five test sites, due in particular to the stronger effect of AOD on DNI compared to GTI. In conclusion, the matrix of subordinate GTI spectra described in this paper are recommended to appear as an option in the annex of future standards, in addition to the obligatory use of the main spectrum from the ASTM G173 and IEC 60904 standards.

14 SOLAR ENERGY↗

Evaluation of external tubular configurations for a high-temperature chloride molten salt solar receiver operating above 700°C

Next-generation concentrating solar power (CSP) tower technologies target operating temperatures exceeding 700°C to increase the thermal-to-electric conversion efficiency. Molten chloride salts are one possible alternative to current commercial molten nitrate salts to enable the higher operating temperature. This paper analyzes the predicted optical, thermal-fluids, and structural performance of traditional external tubular solar receiver configurations applied with a chloride salt heat transfer fluid (HTF) and inlet/outlet temperatures of 500°C/735°C, and considers sensitivity analysis and optimization relative to receiver sizing, tube sizing, number of panels, flow circuit configurations, and solar flux concentration under constraints on internal velocity, pressure drop, wall thickness, and required creep-fatigue lifetime. The high temperature conditions increase the significance of inelastic deformation mechanisms such as creep relative to that expected in commercial 565°C nitrate salt designs. High-temperature creep and creep-fatigue damage in the metal alloy tubes are the key factors that limit allowable solar flux concentration and achievable receiver thermal efficiency at the near-800°C wall temperature conditions. For a traditional external cylindrical receiver configuration, the design parameters and conditions capable of satisfying all constraints produced, at best, a design point receiver efficiency of 78.2%, or 80.5% when excluding receiver intercept efficiency. Variation in the optimal receiver performance relative to uncertainty in the binding maximum velocity, minimum wall thickness, and minimum lifetime constraints is presented.

14 SOLAR ENERGY↗

Effect of temperature on abrasion erosion in particle based concentrating solar powerplants

The use of solid particles as a heat transfer medium is being explored for concentrated solar power plants (CSP) to increase their efficiency by achieving operating temperature >700 °C. During operation, these hot particles are expected to move along the various components within the collector system, resulting in material degradation from a combination of high-temperature oxidation and erosion. In the present study, the performance of candidate materials was evaluated through a series of abrasion erosion experiments at room temperature as well as at 800 °C. Wear in metallic and refractory type materials was investigated using CarboBead® HSP 40/70 particles inside a resistance heated kiln. Furthermore, cross-sectional scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS) analysis on the specimens tested at 800 °C determined that the specific wear rate in Inconel 740H and stainless steel 316 metallic specimens was influenced by the thermally grown oxide morphology. High chromium Inconel 740H specimens exhibited greater resistance to wear with a steady state specific wear rate of 1.92E-4 mm 3 N -1 m –1 compared to 5.7E-3 mm 3 N -1 m –1 for Stainless Steel 316.

14 SOLAR ENERGY↗

A non-intrusive optical approach to characterize heliostats in utility-scale power tower plants: Flight path generation/optimization of unmanned aerial systems

A newly developed in situ non-intrusive optical (NIO) approach has been developed to survey various types of heliostat optical errors for a concentrating solar power (CSP) tower plant. To measure mirror surface slope error, facet canting error, and heliostat tracking error at a sub-milliradian accuracy, NIO requires several reflection images scanned over each individual heliostat. For a utility-scale plant that typically includes more than 10,000 heliostats, an unmanned aerial system (UAS) is crucial for efficient implementation of the NIO method. Here, we develop a flight path generation/optimization algorithm to plan more efficient UAS paths to collect NIO data over a utility-scale heliostat field. The algorithm considers NIO data requirements, all potential constraints, optimization within each subfield, and operational flexibility. Case studies are presented to illustrate the feasibility and robustness of the developed flight path algorithm. The path planning algorithm may also find applications elsewhere, such as drone-driven imaging under extreme conditions.

14 SOLAR ENERGY↗

In-situ thermophysical measurement of flowing molten chloride salt using modulated photothermal radiometry

Molten salts are leading candidates for high-temperature heat transfer fluids (HTFs) for thermal energy storage and conversion systems in concentrated solar power (CSP) and nuclear energy power plants. The ability to probe molten salt thermal transport properties in both stationary and flowing status is important for the evaluation of their heat transfer performance under realistic operational conditions, including the temperature range and potential degradation due to corrosion and contamination. However, accurate thermal transport properties are usually challenging to obtain even for stagnant molten salts due to different sources of errors from convection, radiation, and corrosion, let alone at flowing status. To the best of authors’ knowledge, there is no available in-situ technique for measuring flowing molten salt thermal conductivity. Here, we report the first in-situ flowing molten salt thermal conductivity measurement using modulated photothermal radiometry (MPR). We could successfully perform the first in-situ thermal conductivity measurement of flowing molten NaCl-KCl-MgCl 2 in the typical operating temperature (520 and 580 °C) with flow velocities ranging from around 0.3 to 1.0 m s -1 . The relative change of the molten salt thermal conductivity was measured. Gnielinski’s correlation was also used to estimate the heat transfer coefficient h of the flowing NaCl-KCl-MgCl 2 in the given experimental condition. Furthermore, the work showed the potential of the MPR technique serving as an in-situ diagnostics tool to evaluate the heat transfer performance of flowing molten salts and other high-temperature HTFs.

14 SOLAR ENERGY↗

srlife : a software tool for estimating the life of high temperature concentrating solar receivers. Part I – metallic receivers

Here, this paper introduces srlife, a tool for estimating the structural service life of concentrating solar power (CSP) receivers operating at high temperatures. Supporting both metallic and ceramic receiver designs, srlife is available as open-source software at https://github.com/applied-material-modeling/srlife and can be installed via the PyPi package manager (https://pypi.org). Given basic receiver geometry and incident heat flux, the tool performs thermohydraulic and structural analysis and estimates the life of a receiver. Designed for easy integration into a software stack, including solar field and levelized cost analysis, the tool can be utilized for optimizing receiver designs to meet service life and economic targets. This paper is Part I in a two-part series. Part I discusses the analysis process used to estimate the life of metallic receivers, along with a description of the required input data. Additionally, several heuristics applied within srlife can reduce analysis time significantly while maintaining accurate life estimations for metallic receivers when compared to full analyses. Several examples demonstrating the utility of srlife in receiver design are also discussed. Part II focuses on the life estimation of ceramic receivers, using time-dependent reliability analysis and various ceramic failure models implemented in srlife.

Creep-fatigue analysis↗

Wind Conditions for Solar Energy Facility Design Based on Field Measurements at Nevada Solar One

This study characterises near-surface wind conditions at the Nevada Solar One (NSO) concentrated solar power plant using two years of measurements from a 15-m mast located 30 m west of the solar arrays. The surrounding terrain is fairly flat within 3 km, but nearby solar photovoltaic (PV) and concentrated solar power (CSP) installations introduce strong directional wind inhomogeneity, which motivates a sector-based analysis that distinguishes undisturbed inflow from waked flow. The analysis uses data from three sonic anemometers to assess whether turbulence in the surface layer can be represented as Gaussian and whether standard surface-layer scaling remains valid below 10 m height. The roughness length and displacement height are estimated for twelve directional sectors under near-neutral wind conditions, and all three velocity components show departures from Gaussian behaviour. Spectral analysis indicates that the turbulence contains low-frequency fluctuations with amplitudes higher than those predicted by standard models such as the Kaimal model or the Simiu and Scanlan model. The study introduces a new turbulence spectral model based on the eddy-surface-layer framework to better represent near-surface wind turbulence. The analysis further quantifies the influence of the surrounding power plants on mean wind profiles, one-point spectra, and vertical coherence for all velocity components. The solar collector arrays located 30 m east of the mast significantly modify the turbulence structure, whereas PV installations situated a few hundred metres away have only a limited influence on the turbulence measured at the mast. These findings highlight the limitations of conventional turbulence models for near-surface wind over solar infrastructure and provide improved parameterisations to support the structural design. The implications for the structural response of parabolic troughs and PV modules to such turbulence remain uncertain and require further investigation.

14 SOLAR ENERGY↗

Amorphous and partially-amorphous metal coatings for corrosion resistance in molten chloride salt

In this study, amorphous metal coatings were developed to improve the corrosion resistance of structural alloys in molten salts for use as salt-facing materials in concentrating solar power (CSP) and molten salt reactor (MSR) applications. Three coatings were tested. One Fe-based, fully amorphous coating, and two Ni-based partially amorphous coatings. The candidate coatings were applied to samples made from Ni-based alloy 230, and exposed to KCl–MgCl 2 at 750 °C for 300 h in sealed Mo capsules. After exposure, uncoated alloy 230 samples were depleted in chromium near the surface, as measured by SEM-EDS. The attack had an average depth of 33 μm. Lastly, all three coatings performed well, showing no observable degradation during exposure, despite chromium contents between 20% and 40%. XRD and TEM measurements showed the coatings were fully crystallized after exposure, so the excellent corrosion resistance can likely be attributed to the recrystallized microstructure of the coatings.

14 SOLAR ENERGY↗

High-Pressure Investigation of 2,4,6-Trinitro-3-bromoanisole (TNBA): Structural Determination and Piezochromism

Understanding phase transitions in energetic materials is crucial for developing predictive models of detonation. 2,4,6-Trinitro-3-bromoanisole (TNBA), an energetic material, was studied in its single-crystal form up to pressures of 45 GPa in a diamond anvil cell. The material was characterized by using X-ray, Raman, and optical transmission measurements. From single-crystal X-ray diffraction, the ambient structure of TNBA was determined which crystallizes in the P2 1 /c space group having four molecular units per unit cell. The X-ray data up to 9.2 GPa were fitted to a third-order Birch–Murnaghan equation of state by using the parameters K o = 13.2(2.4) GPa and K p = 5.1(1.4). Between 6.8 and 7.3 GPa, a phase transition was inferred in TNBA from concurrent fading of X-ray diffraction, disappearance of Raman peaks, increase in sample fluorescence, and discontinuous color change. The new phase was consistent with an amorphous state of at least partially intact molecules judging from the presence of higher-order Raman modes and irreversibility of the Raman spectra upon release. Piezochromism was observed with the translucent yellow TNBA gradually darkening and becoming opaque black at ~25 GPa. This correlated to the absorption edge gradually shifting to the red in the visible spectrum. Signs of two possible additional structural transitions were detected in the 32.4–41.0 GPa range as suggested by a jump in the absorption edge, the irreversible changes in the absorption spectrum upon release to ambient pressure, and by the lack of Raman modes in recovered samples. Here, the crystal and electronic structures of TNBA were also investigated up to 10 GPa by using DFT calculations and crystal structure prediction (CSP) simulations. In agreement with the experimentally observed transition at 7 GPa, the simulations at 10 GPa found a bevy of polymorphs lower in enthalpy and higher in density than P2 1 /c. The lowest calculated enthalpy structure was determined to be P2 1 2 1 2 1 , being in a different space group than the ambient experimental result.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗