At least 937 records · Page 52

(U) Energy-Dependent Perturbations of Scattering Cross Sections Using the PERT Card in MCNP6.2

The PERT card is used for first- and second-order perturbations of material densities, isotope densities, and isotope cross sections in the MCNP6.2 Monte Carlo code. Using the PERT card for firstand second-order sensitivities is straightforward. Reference 2 only looked at density perturbations with no energy dependence. This report looks at the sensitivity of a response to scattering cross sections as a function of energy and finds that there is a bug in the PERT capability. The SENSMG multigroup neutron sensitivity code was recently given the capability of computing sensitivities to user-specified reactions whose cross sections are available in a user-supplied NJOY output file. SENSMG uses the PARTISN multigroup discrete ordinates code for the transport. The NJOY-reaction capability is similar to that of SUSD3D, which also uses PARTISN for the multigroup transport. The PERT bug was identified by comparing MCNP6.2 outputs with SENSMG outputs. The next section of this report describes the test problem. Section III presents the MCNP6.2 PERT bug and proposes a solution. Section IV is a summary and conclusions. The SENSMG and MCNP input files are listed in the appendix.

07 ISOTOPE AND RADIATION SOURCES↗

High-resolution wall temperature measurements with distributed fiber optic sensors

Conventional approaches of surface temperature measurement are often unreliable, and other methods may not be practical in closed, high-temperature spaces. In this study, surface temperature measurements of the cooling panel of a natural circulation facility were performed with fiber optic distributed temperature sensors (DTS). High resolution surface temperature profiles of the cooling panel were acquired under two steady experimental conditions, and compared with measurements performed with nearby thermocouples. The total measurement error of the DTS results presented has been estimated to be ±4.4 °C. The findings reflected herein show that these DTS can reasonably measure surface temperature when installed with the methods developed in this study. Through the analysis of the DTS data collected, the interesting behavior of the cooling panel was revealed, providing new insights on the system's behavior that may be beneficial to the design and optimization of such heat transfer devices. These sensors can also provide the measurement density necessary for validation efforts with highly-resolved prediction methods such as finite element analysis (FEA) or computational fluid dynamics (CFD).

47 OTHER INSTRUMENTATION↗

Solid waste bin detection and classification using Dynamic Time Warping and MLP classifier

Highlights: • Solid waste bin level detection using Dynamic Time Warping (DTW). • Gabor wavelet filter is used to extract the solid waste image features. • Multi-Layer Perceptron classifier network is used for bin image classification. • The classification performance evaluated by ROC curve analysis. - Abstract: The increasing requirement for Solid Waste Management (SWM) has become a significant challenge for municipal authorities. A number of integrated systems and methods have introduced to overcome this challenge. Many researchers have aimed to develop an ideal SWM system, including approaches involving software-based routing, Geographic Information Systems (GIS), Radio-frequency Identification (RFID), or sensor intelligent bins. Image processing solutions for the Solid Waste (SW) collection have also been developed; however, during capturing the bin image, it is challenging to position the camera for getting a bin area centralized image. As yet, there is no ideal system which can correctly estimate the amount of SW. This paper briefly discusses an efficient image processing solution to overcome these problems. Dynamic Time Warping (DTW) was used for detecting and cropping the bin area and Gabor wavelet (GW) was introduced for feature extraction of the waste bin image. Image features were used to train the classifier. A Multi-Layer Perceptron (MLP) classifier was used to classify the waste bin level and estimate the amount of waste inside the bin. The area under the Receiver Operating Characteristic (ROC) curves was used to statistically evaluate classifier performance. The results of this developed system are comparable to previous image processing based system. The system demonstration using DTW with GW for feature extraction and an MLP classifier led to promising results with respect to the accuracy of waste level estimation (98.50%). The application can be used to optimize the routing of waste collection based on the estimated bin level.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamics from noisy data with extreme timing uncertainty

Imperfect knowledge of the times at which ‘snapshots’ of a system are recorded degrades our ability to recover dynamical information, and can scramble the sequence of events. In X-ray free-electron lasers, for example, the uncertainty—the so-called timing jitter—between the arrival of an optical trigger (‘pump’) pulse and a probing X-ray pulse can exceed the length of the X-ray pulse by up to two orders of magnitude, marring the otherwise precise time-resolution capabilities of this class of instruments. The widespread notion that little dynamical information is available on timescales shorter than the timing uncertainty has led to various hardware schemes to reduce timing uncertainty. These schemes are expensive, tend to be specific to one experimental approach and cannot be used when the record was created under ill-defined or uncontrolled conditions such as during geological events. Here we present a data-analytical approach, based on singular-value decomposition and nonlinear Laplacian spectral analysis, that can recover the history and dynamics of a system from a dense collection of noisy snapshots spanning a sufficiently large multiple of the timing uncertainty. In this work, the power of the algorithm is demonstrated by extracting the underlying dynamics on the few-femtosecond timescale from noisy experimental X-ray free-electron laser data recorded with 300-femtosecond timing uncertainty. Using a noisy dataset from a pump-probe experiment on the Coulomb explosion of nitrogen molecules, our analysis reveals vibrational wave-packets consisting of components with periods as short as 15 femtoseconds, as well as more rapid changes, which have yet to be fully explored. Our approach can potentially be applied whenever dynamical or historical information is tainted by timing uncertainty.

47 OTHER INSTRUMENTATION↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Moment expansion of polarized dust SED: A new path towards capturing the CMB B -modes with LiteBIRD

Accurate characterization of the polarized dust emission from our Galaxy will be decisive in the quest for the cosmic microwave background (CMB) primordial B-modes. An incomplete modeling of its potentially complex spectral properties could lead to biases in the CMB polarization analyses and to a spurious measurement of the tensor-to-scalar ratio r. It is particularly crucial for future surveys like the LiteBIRD satellite, the goal of which is to constrain the faint primordial signal leftover by inflation with an accuracy on the tensor-to-scalar ratio r of the order of 10 –3 . Variations of the dust properties along and between lines of sight lead to unavoidable distortions of the spectral energy distribution (SED) that cannot be easily anticipated by standard component-separation methods. This issue can be tackled using a moment expansion of the dust SED, an innovative parametrization method imposing minimal assumptions on the sky complexity. In the present paper, we apply this formalism to the B-mode cross-angular power spectra computed from simulated LiteBIRD polarization data at frequencies between 100 and 402 GHz that contain CMB, dust, and instrumental noise. The spatial variation of the dust spectral parameters (spectral index β and temperature T) in our simulations lead to significant biases on r (~21 σ r ) if not properly taken into account. Performing the moment expansion in β, as in previous studies, reduces the bias but does not lead to sufficiently reliable estimates of r. We introduce, for the first time, the expansion of the cross-angular power spectra SED in both β and T, showing that, at the sensitivity of LiteBIRD, the SED complexity due to temperature variations needs to be taken into account in order to prevent analysis biases on r. Thanks to this expansion, and despite the existing correlations between some of the dust moments and the CMB signal responsible for a rise in the error on r, we can measure an unbiased value of the tensor-to-scalar ratio with a dispersion as low as σ r = 8.8 × 10 –4 .

79 ASTRONOMY AND ASTROPHYSICS↗

Design of and data reduction from compact Thomson parabola spectrometers

Thomson parabola spectrometers are used to characterize MeV ion beams produced in high intensity laser interactions. These spectrometers disperse multiple ion species according to their charge to mass ratio through the use of parallel electric and magnetic fields. Analytical solutions for ion deflection in electric and magnetic fields have been used to extract ion spectra with the assumption that fringing effects are negligible. Experimental space restrictions and dynamic range requirements necessitate designs that stress the analytical assumptions. Depending on design parameters, the error in the analytical assumption can be comparable to the energy resolution. Estimates are provided to approximate the error on the total ion deflection. A method for modeling ion trajectories including fringing effects is presented using software freely available or in common use. The magnetostatic fields are modeled in 3D, including material properties of nearby magnetic materials using RADIA. Electrostatic fields are modeled in 2D for a spectrometer implementing angled plates using the partial differential equation toolbox in MATLAB. Using these models to calculate the ion trajectory allows for analysis of a Thomson parabola spectrometer with an arbitrary field configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A plastic miniature x-ray emission spectrometer based on the cylindrical von Hamos geometry

We present a short working distance miniature x-ray emission spectrometer (miniXES) based on the cylindrical von Hamos geometry. We describe the general design principles for the spectrometer and detail a specific implementation that covers K{beta} and valence level emission from Fe. Large spatial and angular access to the sample region provides compatibility with environmental chambers, microprobe, and pump/probe measurements. The primary spectrometer structure and optic is plastic, printed using a 3-dimensional rapid-prototype machine. The spectrometer is inexpensive to construct and is portable; it can be quickly set up at any focused beamline with a tunable narrow bandwidth monochromator. The sample clearance is over 27 mm, providing compatibility with a variety of environment chambers. An overview is also given of the calibration and data processing procedures, which are implemented by a multiplatform user-friendly software package. Finally, representative measurements are presented. Background levels are below the level of the K{beta}{sub 2,5} valence emission, the weakest diagram line in the system, and photometric analysis of count rates finds that the instrument is performing at the theoretical limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Practical considerations in realizing a magnetic centrifugal mass filter

The magnetic centrifugal mass filter concept represents a variation on the plasma centrifuge, with applications that are particularly promising for high-throughput separation of ions with large mass differences. A number of considerations, however, constrain the parameter space in which this device operates best. The rotation speed, magnetic field intensity, and ion temperature are constrained by the ion confinement requirements. Collisions must also be large enough to eject ions, but small enough not to eject them too quickly. The existence of favorable regimes meeting these constraints is demonstrated by a single-particle orbit code. As an example of interest, it is shown that separation factors of about 2.3 are achievable in a single pass when separating Aluminum from Strontium ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Permanent magnet electron beam ion source/trap systems with bakeable magnets for improved operation conditions

The magnetic system of a Dresden electron beam ion source (EBIS) generating the necessary magnetic field with a new type of permanent magnet made of high energy density NdFeB-type material operable at temperatures above 100 °C has been investigated and tested. The employment of such kind of magnets provides simplified operation without the time-consuming installation and de-installation procedures of the magnets for the necessary baking of the ion source after commissioning and maintenance work. Furthermore, with the use of a new magnetization technique the geometrical filling factor of the magnetic Dresden EBIS design could be increased to a filling factor of 100% leading to an axial magnetic field strength of approximately 0.5 T exceeding the old design by 20%. Simulations using the finite element method software Field Precision and their results compared with measurements are presented as well. It could be shown that several baking cycles at temperatures higher than 100 °C did not change the magnetic properties of the setup.

43 PARTICLE ACCELERATORS↗

A reliable control system for measurement on film thickness in copper chemical mechanical planarization system

In recent years, a variety of film thickness measurement techniques for copper chemical mechanical planarization (CMP) are subsequently proposed. In this paper, the eddy-current technique is used. In the control system of the CMP tool developed in the State Key Laboratory of Tribology, there are in situ module and off-line module for measurement subsystem. The in situ module can get the thickness of copper film on wafer surface in real time, and accurately judge when the CMP process should stop. This is called end-point detection. The off-line module is used for multi-points measurement after CMP process, in order to know the thickness of remained copper film. The whole control system is structured with two levels, and the physical connection between the upper and the lower is achieved by the industrial Ethernet. The process flow includes calibration and measurement, and there are different algorithms for two modules. In the process of software development, C++ is chosen as the programming language, in combination with Qt OpenSource to design two modules’ GUI and OPC technology to implement the communication between the two levels. In addition, the drawing function is developed relying on Matlab, enriching the software functions of the off-line module. The result shows that the control system is running stably after repeated tests and practical operations for a long time.

42 ENGINEERING↗

A differential dielectric spectroscopy setup to measure the electric dipole moment and net charge of colloidal quantum dots

A sensitive dielectric spectroscopy setup is built to measure the response of nanoparticles dispersed in a liquid to an alternating electric field over a frequency range from 10{sup −2} to 10{sup 7} Hz. The measured complex permittivity spectrum records both the rotational dynamics due to a permanent electric dipole moment and the translational dynamics due to net charges. The setup consists of a half-transparent capacitor connected in a bridge circuit, which is balanced on pure solvent only, using a software-controlled compensating voltage. In this way, the measured signal is dominated by the contributions of the nanoparticles rather than by the solvent. We demonstrate the performance of the setup with measurements on a dispersion of colloidal CdSe quantum dots in the apolar liquid decalin.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inner surface flash-over of insulator of low-inductance high-voltage self-breakdown gas switch and its application

In this paper, the inner surface flash-over of high-voltage self-breakdown switch, which is used as a main switch of pulse modulator, is analyzed in theory by employing the method of distributed element equivalent circuit. Moreover, the field distortion of the switch is simulated by using software. The results of theoretical analysis and simulation by software show that the inner surface flash-over usually starts at the junction points among the stainless steel, insulator, and insulation gas in the switch. A switch with improved structure is designed and fabricated according to the theoretical analysis and simulation results. Several methods to avoid inner surface flash-over are used to improve the structure of switch. In experiment, the inductance of the switch is no more than 100 nH, the working voltage of the switch is about 600 kV, and the output voltage and current of the accelerator is about 500 kV and 50 kA, respectively. And the zero-to-peak rise time of output voltage at matched load is less than 30 ns due to the small inductance of switch. The original switch was broken-down after dozens of experiments, and the improved switch has been worked more than 200 times stably.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies on the coupling transformer to improve the performance of microwave ion source

A 2.45 GHz microwave ion source has been developed and installed at the Variable Energy Cyclotron Centre to produce high intensity proton beam. It is operational and has already produced more than 12 mA of proton beam with just 350 W of microwave power. In order to optimize the coupling of microwave power to the plasma, a maximally flat matching transformer has been used. In this paper, we first describe an analytical method to design the matching transformer and then present the results of rigorous simulation performed using ANSYS HFSS code to understand the effect of different parameters on the transformed impedance and reflection and transmission coefficients. Based on the simulation results, we have chosen two different coupling transformers which are double ridged waveguides with ridge widths of 24 mm and 48 mm. We have fabricated these transformers and performed experiments to study the influence of these transformers on the coupling of microwave to plasma and extracted beam current from the ion source.

43 PARTICLE ACCELERATORS↗

Design of 95 GHz gyrotron based on continuous operation copper solenoid with water cooling

The design work for 2nd harmonic 95 GHz, 50 kW gyrotron based on continuous operation copper solenoid is presented. Thermionic magnetron injection gun specifications were calculated according to the linear trade off equation, and simulated with CST program. Numerical code is used for cavity design using the non-uniform string equation as well as particle motion in the “cold” cavity field. The mode TE02 with low Ohmic losses in the cavity walls was chosen as the operating mode. The Solenoid is designed to induce magnetic field of 1.8 T over a length of 40 mm in the interaction region with homogeneity of ±0.34%. The solenoid has six concentric cylindrical segments (and two correction segments) of copper foil windings separated by water channels for cooling. The predicted temperature in continuous operation is below 93 °C. The parameters of the design together with simulation results of the electromagnetic cavity field, magnetic field, electron trajectories, and thermal analyses are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hysteresis prediction inside magnetic shields and application

We have developed a simple model that is able to describe and predict hysteresis behavior inside Mumetal magnetic shields, when the shields are submitted to ultra-low frequency (<0.01 Hz) magnetic perturbations with amplitudes lower than 60 μT. This predictive model has been implemented in a software to perform an active compensation system. With this compensation the attenuation of longitudinal magnetic fields is increased by two orders of magnitude. The system is now integrated in the cold atom space clock called PHARAO. The clock will fly onboard the International Space Station in the frame of the ACES space mission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computer tomography of large dust clouds in complex plasmas

The dust density is a central parameter of a dusty plasma. Here, a tomography setup for the determination of the three-dimensionally resolved density distribution of spatially extended dust clouds is presented. The dust clouds consist of micron-sized particles confined in a radio frequency argon plasma, where they fill almost the entire discharge volume. First, a line-of-sight integrated dust density is obtained from extinction measurements, where the incident light from an LED panel is scattered and absorbed by the dust. Performing these extinction measurements from many different angles allows the reconstruction of the 3D dust density distribution, analogous to a computer tomography in medical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An open source digital servo for atomic, molecular, and optical physics experiments

We describe a general purpose digital servo optimized for feedback control of lasers in atomic, molecular, and optical physics experiments. The servo is capable of feedback bandwidths up to roughly 1 MHz (limited by the 320 ns total latency); loop filter shapes up to fifth order; multiple-input, multiple-output control; and automatic lock acquisition. The configuration of the servo is controlled via a graphical user interface, which also provides a rudimentary software oscilloscope and tools for measurement of system transfer functions. We illustrate the functionality of the digital servo by describing its use in two example scenarios: frequency control of the laser used to probe the narrow clock transition of {sup 27}Al{sup +} in an optical atomic clock, and length control of a cavity used for resonant frequency doubling of a laser.