Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Conversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

A closed, digital telephone system

Digital system can accommodate sixteen or more telephone or data units and eight, simultaneous two-way conversations through only four interconnecting wires. It uses fewer circuit components, is not bulky or complex, and requires no central exchange control.

Monford, L. G., Jr.↗

Digital receiver study and implementation

Computer software was developed which makes it possible to use any general purpose computer with A/D conversion capability as a PSK receiver for low data rate telemetry processing. Carrier tracking, bit synchronization, and matched filter detection are all performed digitally. To aid in the implementation of optimum computer processors, a study of general digital processing techniques was performed which emphasized various techniques for digitizing general analog systems. In particular, the phase-locked loop was extensively analyzed as a typical non-linear communication element. Bayesian estimation techniques for PSK demodulation were studied. A hardware implementation of the digital Costas loop was developed.

Fogle, D. A.↗

Flexstab on the IBM 360

FLEXSTAB, an array of computer programs developed on CDC equipment, has been converted to operate on the IBM 360 computation system. Instructions for installing, validating, and operating FLEXSTAB on the IBM 360 are included. Hardware requirements are itemized and supplemental materials describe JCL sequences, the CDC to IBM conversion, the input output subprograms, and the interprogram data flow.

Pyle, R. S.↗

Comparative performance of solar thermal power generation concepts

A performance comparison is made between the central receiver system (power tower) and a distributed system using either dishes or troughs and lines to transport fluids to the power station. These systems were analyzed at a rated capacity of 30 MW of thermal energy delivered in the form of superheated steam at 538 C (1000 F) and 68 atm (1000 psia), using consistent weather data, collector surface waviness, pointing error, and electric conversion efficiency. The comparisons include technical considerations for component requirements, land utilization, and annual thermal energy collection rates. The relative merits of different representative systems are dependent upon the overall conversion as expressed in the form of performance factors in this paper. These factors are essentially indices of the relative performance effectiveness for different concepts based upon unit collector area. These performance factors enable further economic tradeoff studies of systems to be made by comparing them with projected production costs for these systems.

Wen, L.↗

Measurements of the O+ plus N2 and O+ plus O2 reaction rates from 300 to 900 K

Rate coefficients for the O(+) + N2 atom transfer and O(+) + O2 charge transfer reactions are determined at thermal energies between 300 K and 900 K difference in a heated drift tube mass spectrometer apparatus. At 300 K the values K(O(+) + N2) = (1.2 plus or minus 0.1) x 10 to the negative 12 power cubic cm/sec and k(O(+) + O2) = (2.1 plus or minus 0.2) x 10 to the negative 11 power cubic cm/sec were obtained, with a 50% difference decrease in the reaction rates upon heating to 700 K. These results are in good agreement with heated flowing afterglow results, but the O(+) + O2 thermal rate coefficients are systematically lower than equivalent Maxwellian rates inferred by conversion of nonthermal drift tube and flow drift data.

Chen, A.↗

Pupillometry, a bioengineering overview

The pupillary control system is examined using a microprocessor based integrative pupillometer. The real time software functions of the microprocessor include: data collection, stimulus generation and area to diameter conversion. Results of an analysis of linear and nonlinear phenomena are presented.

Myers, G.↗

Neutron and gamma-ray signatures for particle acceleration in solar flares

The production of neutrons, 4 to 7 MeW nuclear gamma rays, positrons and pions resulting from the interaction of flare accelerated particles with the solar atmosphere was calculated. For the energy spectra of these particles the Bessel function predicted by stochastic acceleration and power laws which could result from acceleration at large-scale planar shocks was used, with the thick-target model. It is assumed that in the interaction region the accelerated particles are isotropic. The neutron-to-2.223 MeV photon conversion factors for various flare locations on the Sun are derived by averaging conversion factors over these spectra. Comparing calculations with data confirms that for most gamma-ray flares the bulk of the accelerated particles remain trapped at the Sun and that these particles have spectra similar to the spectra of flare particles observed in interplanetary space.

Ramaty, R.↗

Life sciences flight experiments microcomputer

A promising microcomputer configuration for the Spacelab Life Sciences Lab. Equipment inventory consists of multiple processors. One processor's use is reserved, with additional processors dedicated to real time input and output operations. A simple form of such a configuration, with a processor board for analog to digital conversion and another processor board for digital to analog conversion, was studied. The system used digital parallel data lines between the boards, operating independently of the system bus. Good performance of individual components was demonstrated: the analog to digital converter was at over 10,000 samples per second. The combination of the data transfer between boards with the input or output functions on each board slowed performance, with a maximum throughput of 2800 to 2900 analog samples per second. Any of several techniques, such as use of the system bus for data transfer or the addition of direct memory access hardware to the processor boards, should give significantly improved performance.

Bartram, Peter N.↗

Summary of Current Radiometric Calibration Coefficients for Landsat MSS, TM, ETM+, and EO-1 ALI Sensors

This paper provides a summary of the current equations and rescaling factors for converting calibrated Digital Numbers (DNs) to absolute units of at-sensor spectral radiance, Top-Of- Atmosphere (TOA) reflectance, and at-sensor brightness temperature. It tabulates the necessary constants for the Multispectral Scanner (MSS), Thematic Mapper (TM), Enhanced Thematic Mapper Plus (ETM+), and Advanced Land Imager (ALI) sensors. These conversions provide a basis for standardized comparison of data in a single scene or between images acquired on different dates or by different sensors. This paper forms a needed guide for Landsat data users who now have access to the entire Landsat archive at no cost.

Chander, Gyanesh↗

An Improved Plastically Dilatant Unified Viscoplastic Constitutive Formulation for Multiscale Analysis of Polymer Matrix Composites Under High Strain Rate Loading

Polymer matrix composites are commonly used to fabricate energy-absorbing structures expected to experience impact loading. As such, a detailed understanding of the dynamic response of the constituent materials is necessary. Since the rate, temperature, and pressure dependence of carbon fiber reinforced polymer matrix composites are primarily manifestations of the rate, temperature, and pressure dependence of the polymer matrix, it is crucial that the constitutive behavior of the matrix be accurately characterized. In this work, an existing unified viscoplastic constitutive formulation is extended to ensure thermodynamic consistency and to more accurately account for the tension-compression asymmetry observed in the response of polymeric materials. A new plastic potential function is proposed, and elementary loading conditions are utilized to determine relations between model constants to ensure nonnegative plastic dissipation, a necessary thermodynamic requirement. Expressions for plastic Poisson’s ratios are derived and are bounded by enforcing nonnegative plastic dissipation. The model is calibrated against available experimental data from tests conducted over a range of strain rates, temperatures, and loading cases on a representative thermoset epoxy; good correlation between simulations and experimental data is obtained. Temperature rises due to the conversion of plastic work to heat are computed via the adiabatic heat energy equation. The viscoplastic polymer model is then used as a constitutive model in the generalized method of cells micromechanics theory to investigate the effects of matrix adiabatic heating on the high strain rate response of a unidirectional composite. The thermodynamic consistency of the model ensures plastic dissipation can only cause an increase in temperature. Simulation results indicate that significant thermal softening due to the conversion of plastic work to heat is observed in the composite for matrix dominated deformation modes.

Impact loading↗

Addressing the Energy Crisis At Uranus via Magnetic Reconnection

The long-standing 'energy crisis' at Uranus refers to the seemingly anomalous heating of the planet's thermosphere (requires ~200GW) compared to the available input energy from the Sun (~20GW). At Uranus this crisis is further exacerbated by a decades-long thermospheric cooling of H3+ observed from 1980 to present. Input energy from the magnetosphere has been invoked as a possible solution to the energy crisis, though the total available energy and how it may vary with time have not been quantified. We apply a recent scaling of the energy conversion rate of magnetic reconnection developed from recent data from NASA's Magnetospheric Multiscale (MMS) mission to the Uranus system. We find that the energy input is most modulated by solar activity, producing >100GW in solar max and approximately half that during solar minimum. During solar minimum, the remaining energy input required to the Uranus system may be dominated by the Kelvin-Helmholtz instability that is more active for time periods with weaker interplanetary magnetic fields. The declining intensity of solar maxima over the past several decades could account for the observed thermospheric cooling and the ascending phase of the current solar cycle should lead to increases in observed thermospheric H3+ temperatures. Neither process of energy input appears to be significantly impacted by Uranus season or magnetospheric

Daniel Gershman↗

Performance Risk Model Validation with Operationally Relevant Tasks

Human Research Program aims to develop methods to support astronauts’ health and productivity during spaceflight. The Crew Health and Performance Probabilistic Risk Assessment (CHP-PRA) team uses powerful computational methods to predict mission risk in both domains: medical and performance. Here, we show how CHP-PRA uses the Performance Risk Model (PRisM) to quantify the performance risk and show an application of the model on operationally relevant tasks. There are various metrics adopted across performance researchers that PRisM can accommodate. For data analysis, interpretation, and integration, we use a method of unifying data from multiple sources by converting each to a single metric. We consult subject matter experts prior to integrating the converted data into PRisM. The method we use is inspired by the Cooper-Harper rating scale [1]. Using this unified metric, we can easily combine data from various tests and lab groups. We explain our conversion method in detail and show how it pertains to the process of testing and validation of PRisM on operational tasks. We conducted an initial validation in collaboration with the Behavioral Health and Performance (BHP) lab. We test PRisM using data on their operationally relevant task ROBoT-r, a track-and-capture task for grappling incoming resupply vehicles [2]. Several other labs at NASA Johnson Space Center worked together to design 7 Functional Task Tests (FTTs) in pursuit of simulating the tasks required after landing on a planetary surface and after return to Earth [3]. Here we use the results from both ROBoT-r and the 7 FTTs and compare their experiment data to PRisM’s computational output to demonstrate how PRisM can support operations by predicting crew performance on future missions.

performance modeling↗

Next Generation Hydrogen Station Analysis

This presentation was part of the U.S. Department of Energy Hydrogen Program's Annual Merit Review and Peer Evaluation Meeting, reporting on project TA042, hydrogen refueling station evaluation.

CDP↗

Radiation Tolerant Electronics and Digital Processing for the Phase-1 Read-out Upgrade of the ATLAS Liquid Argon Calorimeters

The ATLAS Liquid Argon calorimeters are designed and built to study proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV. Liquid argon (LAr) sampling calorimeters are employed for all electromagnetic calorimetry in the pseudorapidity region |η|<3.2, and for hadronic calorimetry in the region from |η|=1.5 to |η|=4.9. Although the nominal LHC experimental programme is still in progress, an upgrade of the read-out electronics is being launched to cope with luminosities of up to 3x10{sup 34} cm{sup -2}s{sup -1}, which are beyond the original design by a factor of 3. An improved spatial granularity of the trigger primitives is therefore proposed in order to improve the identification performance for trigger signatures, like electrons, photons, tau leptons, jets, total and missing energy, at high background rejection rates. For the upgrade Phase-1 in 2018, new LAr Trigger Digitizer Boards (LTDB) are being designed to receive higher granularity signals, digitize them on detector and send them via fast optical links to a new LAr digital processing system (LDPS). The LDPS applies a digital filtering and identifies significant energy depositions in each trigger channel. The refined trigger primitives are then transmitted to the first level trigger system to extract improved trigger signatures. The read-out of the trigger signals will process 34000 so-called Super Cells at every LHC bunch-crossing at a frequency of 40 MHz. The new LTDB on-detector electronics is designed to be radiation tolerant in order to be operated for the remaining live-time of the ATLAS detector up to a total luminosity of 3000 fb{sup -1}. For the analog-to-digital conversion (12-bit ADC at 40 MSPS), the data serialization and the fast optical link (5.44 Gb/s) custom components have been developed. They have been qualified for the expected radiation environment of a total ionization dose of 1.3 kGy and a hadron fluence of 6 x 10{sup 13} h/cm{sup 2} with energies above 20 MeV. For the digital components like the ADC, cross-sections for single event effects have been determined. This talk will present R and D results from tests of the radiation tolerant components, the fast data processing electronics and prototypes of the LTDB and LDPS boards. First experience from a Demonstrator setup will be reported, in which about 1/10 of the full Super Cell readout will be equipped with prototype versions of the LTDB and LDPS boards. The Demonstrator will be operated in parallel to the regular ATLAS trigger read-out during the upcoming LHC run. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship

Purpose: The conversion of the computed tomography (CT) number to electron density is one of the main processes that determine the accuracy of patient dose calculations in radiotherapy treatment planning. However, the CT number and electron density of tissues cannot be generally interrelated via a simple one-to-one correspondence because the CT number depends on the effective atomic number as well as the electron density. The purpose of this study is to present a simple conversion from the energy-subtracted CT number ({Delta}HU) by means of dual-energy CT (DECT) to the relative electron density ({rho}{sub e}) via a single linear relationship. Methods: The {Delta}HU-{rho}{sub e} conversion method was demonstrated by performing analytical DECT image simulations that were intended to imitate a second-generation dual-source CT (DSCT) scanner with an additional tin filtration for the high-kV tube. The {Delta}HU-{rho}{sub e} calibration line was obtained from the image simulation with a 33 cm-diameter electron density calibration phantom equipped with 16 inserts including polytetrafluoroethylene, polyvinyl chloride, and aluminum; the elemental compositions of these three inserts were quite different to those of body tissues. The {Delta}HU-{rho}{sub e} conversion method was also applied to previously published experimental CT data, which were measured using two different CT scanners, to validate the clinical feasibility of the present approach. In addition, the effect of object size on {rho}{sub e}-calibrated images was investigated by image simulations using a 25 cm-diameter virtual phantom for two different filtrations: with and without the tin filter for the high-kV tube. Results: The simulated {Delta}HU-{rho}{sub e} plot exhibited a predictable linear relationship over a wide range of {rho}{sub e} from 0.00 (air) to 2.35 (aluminum). Resultant values of the coefficient of determination, slope, and intercept of the linear function fitted to the data were close to those of the ideal case. The maximum difference between the ideal and simulated {rho}{sub e} values was -0.7%. The satisfactory linearity of {Delta}HU-{rho}{sub e} was also confirmed from analyses of the experimental CT data. In the experimental cases, the maximum difference between the nominal and simulated {rho}{sub e} values was found to be 2.5% after two outliers were excluded. When compared with the case without the tin filter, the {Delta}HU-{rho}{sub e} conversion performed with the tin filter yielded a lower dose and more reliable {rho}{sub e} values that were less affected by the object-size variation. Conclusions: The {Delta}HU-{rho}{sub e} calibration line with a simple one-to-one correspondence would facilitate the construction of a well-calibrated {rho}{sub e} image from acquired dual-kV images, and currently, second generation DSCT may be a feasible modality for the clinical use of the {Delta}HU-{rho}{sub e} conversion method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗