Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Highly Selective Detection of Cr{sup 3+} Ion with Colorimetric & Fluorescent Response Via Chemodosimetric Approach in Aqueous Medium

So far, very few numbers of chemosensors for Cr{sup 3+} ion have been reported. However, the main drawback of reported receptors are the lack of selectivity and other trivalent cations such as Fe{sup 3+}, Al{sup 3+} and anions like F{sup −} and {sup −}OAc frequently interfere with such assays. This paper present the synthesis, characterization & sensor studies of Schiff base containing naphthalene moiety which selectively detect Cr{sup 3+} ion by chemodosimetric approach. Using FT-IR, {sup 1}H NMR, {sup 13}C NMR and ESI mass spectroscopic techniques the probe was characterized. This receptor exhibit more selectivity and sensitivity towards Cr{sup 3+} than other divalent and trivalent cations like Mn{sup 2+}, Zn{sup 2+}, Co{sup 2+}, Ni{sup 2+}, Cd{sup 2+}, Cu{sup 2+}, Hg{sup 2+}, Fe{sup 3+}, and Al{sup 3+} ions. After the addition of chromium ion the receptor get change from yellow to colorless in aqueous medium. But no color change was observed on the addition of other metal ions. Using UV-Vis and PL studies, it was confirmed that the selective hydrolysis of imine group of receptor by Cr{sup 3+} ions takes place with high fluorescence enhancement that is corresponding to 1-naphthylamine. Receptor acts as selective chemodosimeter for Cr{sup 3+} ions with 2:1 stoichiometry and micro molar detection limit. This chemodosimetric approach was applied successfully for bio-imaging of HeLa cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of Specific Interaction between bis(p-phenylene)-34-crown-10-based Substituted Macrocycle and Ni{sup 2+}

A novel macrocyclic host has been synthesized for the determination of Ni (II) ions in aqueous solution (H{sub 2}O-CH{sub 3}CN, v/v = 1:1). Its molecular structure has been verified by {sup 1}H-NMR, {sup 13}C NMR and mass spectrometry (ESI).This probe shows selectivity towards the presence of Ni (II) ion among various alkali, alkaline earth, and transition metal ions. The formation of a new fluorescence band at 311 nm has been detected due to possible complex formation with increasing Ni{sup 2+} concentration in the range of 10{sup −5}–10{sup −4} M. The detection limit is calculated to be 5.22 μM. To our knowledge, it will be the first case for bis(p-phenylene)-34-crown-10 based molecules to recognize Ni{sup 2+} ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Novel Fluorescent Nanoparticle for Sensitive Detection of Cry1Ab Protein In Vitro and In Vivo

Here, we report the synthesis and characterization of CoFe{sub 2}O{sub 4} doping Ag{sub 2}S dendrimer-modified nanoparticles (CoFe{sub 2}O{sub 4}-Ag{sub 2}S DMNs) in Cry1Ab protein detection and imaging. The near-infrared Ag{sub 2}S quantum dots were first prepared by using the thermal decomposition method, followed by modification of the water-soluble quantum dots using the method of solvent evaporation and ligand exchange, and finally the fluorescent magnetic bifunctional nanoparticles were obtained by binding with CoFe{sub 2}O{sub 4}. As-prepared CoFe{sub 2}O{sub 4}-Ag{sub 2}S DMNs were characterized by fluorescence (FL) spectroscopy and transmission electron microscopy (TEM). Results showed that Ag{sub 2}S DMNs could sensitively detect Cry1Ab both in vitro and in vivo. In vitro, the enhanced FL intensity as a function of the concentration is notably consistent with the Langmuir binding isotherm equation in the range of 0–200 ng/mL of Cry1Ab proteins. The detection limit of this method was found to be 0.2 ng/mL. Meanwhile, the fluorescence wavelength was extended to the second near-infrared range (NIR-II, 1.0~1.4 μm), which enables in vivo imaging. This study highlights the importance of NIR QDs doping magnetic materials as a new method to trace Bacillus thuringiensis (Bt) in insects and their potential applications in in vivo NIR tissue imaging.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Bis-(2-Hydroxybenzylidene)-1H-Pyrazole 3,5-Dicarbohydrazide as a Novel Chemosensor for the Detection of Endogenous Zinc: A Fluorometric Study

The study reports synthesis and photophysical studies of a new zinc sensing pyrazole scaffold structurally characterized to be bis(2-hydroxybenzylidene)-1H-pyrazole-3,5-dicarbohydrazide (PHSA). Excitation of the probe at 330 nm results in an emission band at 417 nm which ratiometrically red shifts to 466 nm upon Zn{sup 2+} addition in an unprecedented way. The photo induced electron transfer (PET) coupled intramolecular charge transfer (ICT) working for a dual-channel fluorescence emission pathway is observed and studies were supported with density functional theory and NMR titration experiments. The probe exhibited dissociation constant of 1.2156 and detection limit as low as 992 nM. The cytotoxic effects of the probe on 60 tumour cell lines were tested. The intracellular zinc sensing with reversible binding potential is verified with fluorescence microscopy experiment.

74 ATOMIC AND MOLECULAR PHYSICS↗

Radioxenon production through neutron irradiation of stable xenon gas

The Spectral Deconvolution Analysis Tool (SDAT) software was developed to improve counting statistics and detection limits for nuclear explosion radionuclide measurements. SDAT utilizes spectral deconvolution spectroscopy techniques and can analyze both β-γ coincidence spectra for radioxenon isotopes and high-resolution HPGe spectra from aerosol monitors. The deconvolution algorithm of the SDAT requires a library of β-γ coincidence spectra of individual radioxenon isotopes to determine isotopic ratios in a sample. In order to get experimentally produced spectra of the individual isotopes we have irradiated enriched samples of 130Xe, 132Xe, and 134Xe gas with a neutron beam from the TRIGA reactor at The University of Texas. The samples produced were counted in an Automated Radioxenon Sampler/Analyzer (ARSA) style β-γ coincidence detector. The spectra produced show that this method of radioxenon production yields samples with very high purity of the individual isotopes for 131mXe and 135Xe and a sample with a substantial 133mXe to 133Xe ratio.

ARSA↗

Rapid Determination Of Radiostrontium In Large Soil Samples

A new method for the determination of radiostrontium in large soil samples has been developed at the Savannah River Environmental Laboratory (Aiken, SC, USA) that allows rapid preconcentration and separation of strontium in large soil samples for the measurement of strontium isotopes by gas flow proportional counting. The need for rapid analyses in the event of a Radiological Dispersive Device (RDD) or Improvised Nuclear Device (IND) event is well-known. In addition, the recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid analyses for radionuclides in environmental samples in the event of a nuclear accident. The method employs a novel pre-concentration step that utilizes an iron hydroxide precipitation (enhanced with calcium phosphate) followed by a final calcium fluoride precipitation to remove silicates and other matrix components. The pre-concentration steps, in combination with a rapid Sr Resin separation using vacuum box technology, allow very large soil samples to be analyzed for {sup 89,90}Sr using gas flow proportional counting with a lower method detection limit. The calcium fluoride precipitation eliminates column flow problems typically associated with large amounts of silicates in large soil samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid determination of actinides in seawater samples

A new rapid method for the determination of actinides in seawater samples has been developed at the Savannah River National Laboratory. The actinides can be measured by alpha spectrometry or inductively-coupled plasma mass spectrometry. The new method employs novel pre-concentration steps to collect the actinide isotopes quickly from 80 L or more of seawater. Actinides are co-precipitated using an iron hydroxide co-precipitation step enhanced with Ti +3 reductant, followed by lanthanum fluoride co-precipitation. Stacked TEVA Resin and TRU Resin cartridges are used to rapidly separate Pu, U, and Np isotopes from seawater samples. TEVA Resin and DGA Resin were used to separate and measure Pu, Am and Cm isotopes in seawater volumes up to 80 L. This robust method is ideal for emergency seawater samples following a radiological incident. It can also be used, however, for the routine analysis of seawater samples for oceanographic studies to enhance efficiency and productivity. In contrast, many current methods to determine actinides in seawater can take 1–2 weeks and provide chemical yields of ~30–60 %. This new sample preparation method can be performed in 4–8 h with tracer yields of ~85–95 %. By employing a rapid, robust sample preparation method with high chemical yields, less seawater is needed to achieve lower or comparable detection limits for actinide isotopes with less time and effort.

61 RADIATION PROTECTION AND DOSIMETRY↗

Rapid method for the determination of 226Ra in hydraulic fracturing wastewater samples

A new method that rapidly preconcentrates and measures 226 Ra from hydraulic fracturing wastewater samples was developed in the Savannah River Environmental Laboratory. The method improves the quality of 226 Ra measurements using gamma spectrometry by providing up to 100x preconcentration of 226 Ra from this difficult sample matrix, which contains very high levels of calcium, barium, strontium, magnesium and sodium. The high chemical yield, typically 80-90%, facilitates a low detection limit, important for lower level samples, and indicates method ruggedness. Ba-133 tracer is used to determine chemical yield and correct for geometry-related counting issues. The 226 Ra sample preparation takes < 2 hours.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated approaches for reducing sample size for measurements of trace elemental impurities in plutonium by ICP-OES and ICP-MS

This study has demonstrated that bulk plutonium chemical analysis can be performed at small scales (\50 mg material) through three case studies. Analytical methods were developed for ICP-OES and ICP-MS instruments to measure trace impurities and gallium content in plutonium metals with comparable or improved detection limits, measurement accuracy and precision. In two case studies, the sample size has been reduced by 109, and in the third case study, by as much as 50009, so that the plutonium chemical analysis can be performed in a facility rated for lower-hazard and lower-security operations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Simultaneous sub-picogram speciation of methylmercury and ethylmercury in caustic nuclear tank waste using direct aqueous propylation

Organomercury species are present at regulatory levels in the tanks at the Savannah River Site. Calibration of methylmercury and ethylmercury ranged three orders of magnitude, generating detection limits of 0.033 pg and 7.50 pg, respectively. Calibration verifications maintained 101 and 103% accuracy, respectively, with mean recovery from waste samples of 104%. Here, dilution volume was optimized to eliminate sample distillation, decreasing method runtime by 337% and reducing total instrumentation footprint by 60.4% compared with current standard methods. Finally, compared with standard methods, this work represents a significant improvement in safety, efficiency, and reproducibility of organomercury speciation, particularly for industrial and nuclear analysis.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Unique & challenging aspects of plutonium metal standards exchange program for actinide measurements

The Los Alamos National Laboratory exchange program is the only program of its kind for the distribution of plutonium (Pu) standards materials with a range of impurity contents to multiple laboratories for destructive measurements of elemental concentration. This paper discusses statistical methods used to address challenges in Pu metal exchange data by way of two case studies. Challenges include how to evaluate a data set when a large fraction of the values are minimum detection limits (MDLs), and how to determine potential outliers with limited in-formation on the true spread of the data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertainty improvement of 22 Na based radioactive tracer dilution for determining total mass of pyroprocessing molten salt systems by 154 Eu removal

To determine the total salt mass of the molten salt systems for pyroprocessing spent nuclear fuels, a 22 Na based radioactive tracer dilution was studied in Idaho National Laboratory in recent years. This 22 Na based RTD technique was deemed feasible, but due to the gamma energy peak of 22 Na coinciding with one of the energy peaks of 154 Eu radioisotope in the molten salt, the uncertainty of the 22 Na radioactivity in the 22 Na-spiked salt samples was quite high. To improve the uncertainty of the 22 Na based RTD technique, we proposed to chemically remove the 154 Eu of the salt samples by DGA resin for gamma spectroscopy. The effectiveness of removing 154 Eu on uncertainty improvement was evaluated. Furthermore, it was found that (1) the 154 Eu fission product effect on the uncertainty and detection limit can be effectively eliminated by chemically removing the 154 Eu during the salt sample preparation and (2) the uncertainty of 22 Na radioactivity in the salt samples for electrorefining was significantly improved from 13% to 2%, showing the potential of practical engineering application of 22 Na based RTD as a safeguards technique for molten salt systems for pyroprocessing spent nuclear fuels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Designing a high sensitivity hexagonal nano-cavity photonic crystal resonator for the purpose of seawater salinity sensing

In this paper a sensing platform based on nano-cavity photonic crystal resonator (NC-PCR) is proposed for seawater salinity concentration detection. It has been demonstrated that the proposed NC-PCR has high sensitivity and selectivity for various concentrations of seawater salinity. The sensitivity is computed to be as high as 544 nm/RIU (nm per refractive index unit) and the quality factor (Q) is 3860. Also it has been shown that the figure of merit for the proposed structure calculated to be as high as ~ 1.234 × 10{sup 3} RIU{sup −1} which is very appropriate for sensing applications. Moreover, the minimum detection limit for the presented structure is obtained as 8.1 × 10{sup −5} RIU. The finite-difference time-domain method is employed to investigate the transmission characteristics of the device for a verity of refractive indices. It should also be mentioned that our design is comparatively easy to fabricate and certainly the advantages of our design justify its usage in sensing applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Design of refractive index sensing based on 2D PhC air-slot width-modulated line-defect microcavity

In this paper, we propose an investigated sensor array based on two-dimensional photonic crystal air-slot width-modulated line-defect microcavity. This sensor consists of a waveguide coupled with microcavity. To achieve a high quality factor, we have tuned some parameters of the microcavity. The principle of sensing is based on the resonance wavelength shift when the refractive index is changed. For sensitivity analysis, we proposed various conventional designs (A–D). We demonstrated that the design D has the highest sensitivity. An air-slot is created within the line-defect. The existence of the slots enhances the light-matter interactions. The simulation results are obtained by using finite-deference time-domain method. The sensitivity can achieve 400 nm/RIU, with detection limit of 2.98 × 10{sup −5} RIU.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Voltammetric determination of vitamin B{sub 6} (pyridoxine) at a graphite screen-printed electrode modified with graphene oxide/Fe{sub 3}O{sub 4}@SiO{sub 2} nanocomposite

The preparation and study of electrochemical properties of a graphite screen-printed electrode (SPE) modified with the GO/Fe{sub 3}O{sub 4}@SiO{sub 2} (GO is graphene oxide) nanocomposites are described. The morphologies of the GO/Fe{sub 3}O{sub 4}@SiO{sub 2} nanocomposites were examined by scanning electron microscopy. The electrochemical oxidation of vitamin B{sub 6} (pyridoxine) on SPE modified with the GO/Fe{sub 3}O{sub 4}@SiO{sub 2} nanocomposite was investigated by cyclic voltammetry, differential pulse voltammetry, and chronoamperometry. Under optimum conditions (pH 7.0), the vitamin B{sub 6} oxidation at the surface of the modified SPE occurs at a potential about 190 mV less positive than that at the unmodified SPE. A linear voltammetric response for vitamin B{sub 6} was obtained in the concentration range 1.0•10 {sup 6}—9.0•10 {sup 4} mol L{sup –1} with a detection limit of 5.2•10 {sup 7} mol L{sup –1} using differential pulse voltammetry. The developed sensor was also successfully applied for determination of trace level of vitamin B{sub 6} in both the standard vitamin B{sub 6} sample and biological samples (urine).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Shear Displacement and Stress Changes on Fracture Hydraulic Aperture and Flow Anisotropy

Fluid flow in fractures has the potential to drastically change the economic, environmental, and safety risks associated with a subsurface operation. This work focuses on the analysis of experimental shear fracturing and subsequent shear displacement of a shale specimen that contains multiple pre-existing natural fractures. A triaxial direct shear apparatus with concurrent µCT imaging allowed continuous monitoring of sample permeability and changes in fracture geometry during fracture creation, displacement, and changes in stress. Steady-state, low Reynolds number fluid flow simulations were used to determine the changes of each individual fracture’s hydraulic aperture due to displacement and effective stress. The development of anisotropy in the hydraulic aperture of a generated shear fracture was determined for shear displacements of 0.38, 0.74, and 2.04 mm. At high confining stress (30 MPa), shear displacement significantly reduced the hydraulic aperture of the shear fracture to below flow detectable limits and X-ray imaging resolution (23 × 23 × 23 µm 3 ). The shear generated fracture was found to be more sensitive to changes in effective stress compared to the pre-existing natural fractures. Existing models derived from fluid flow equations accounting for stochastic fracture roughness were able to partially fit the simulated flow properties of the pre-existing fractures, but no model was found to fit the flow properties of the newly formed shear fracture. These results are the first report of simultaneous changes in the geometry and flow properties of surrounding, parallel natural fractures as a shear fracture is generated with varying stress and shear displacement conditions.

58 GEOSCIENCES↗

Growth effects and assimilation of organic acids in Chemostat and Batch Cultures of Acidithiobacillus caldus

The ability of Acidithiobacillus caldus to grow aerobically using pyruvate, acetate, citrate, 2-ketoglutarate, succinate, and malate as either an electron donor and carbon source (heterotrophic growth), or as a carbon source when potassium tetrathionate was added as an electron donor (mixotrophic growth), was tested in chemostat cultures. Under both heterotrophic and mixotrophic conditions, organic acids were added to a sub-lethal concentration (50 M). Under mixotrophic conditions, potassium tetrathionate was added to an excess concentration (10 mM). No cell growth was observed under heterotrophic conditions; however effluent cell concentrations increased over three-fold when pyruvate was coupled with potassium tetrathionate. Under these conditions, the effluent pyruvate concentration was reduced to below the detection limit (2 M), and oxygen consumption increased by approximately 100%. Although pyruvate provided a carbon source in these experiments, ambient carbon dioxide was also available to the cells. To test whether At. caldus could grow mixotrophically using pyruvate as a sole carbon source and potassium tetrathionate as an electron donor, cells were batch cultured in a medium free of dissolved inorganic carbon, and with no carbon dioxide in the headspace. These experiments showed that At. caldus was able to convert pyruvate between 65 ± 8 and 82 ± 15% of the pyruvate carbon to cellular biomass, depending on the initial pyruvate concentrations. This work is the first to identify a defined organic-carbon source, other than glucose, that At. caldus can assimilate. This has important implications, as mixotrophic and heterotrophic activity has been shown to increase mineral leaching in acidic systems.

60 APPLIED LIFE SCIENCES↗

Silicon Production via Reaction of Silicon Tetrachloride and Aluminum Subchloride

Silicon tetrachloride reduction by aluminum subchloride was studied experimentally. Aluminum subchloride was synthesized in a reaction of metallic aluminum and AlCl{sub 3}; a burner-like construction of the reactor was used to avoid the direct reaction of aluminum and SiCl{sub 4}. The reduction was conducted at a pressure of 0.1 MPa and two temperature regimes: 1273 K and 1373 K (1000 °C and 1100 °C). As a result, two types of products were obtained: crystals and fine particles. The crystals formation occurred in the high-temperature zone, whereas the particles were dispersed by argon flow and concentrated mainly in aluminum chloride by-product in the cold part of the reactor. It was shown that silicon yield increased with increasing AlCl concentration. The temperature of the reduction process did not have a significant effect on the ultimate silicon yield. However, the silicon etching reaction rate and fine particles yield increased as temperature increased. X-ray diffraction and scanning electron microscopy analysis showed that the impurities content in silicon crystals was below the detection limit. In contrast, the aluminum content in the powder product was 2 to 3 wt pct. Another type of product, yellow blanket-like silicon fibers, was obtained with a high yield at 1373 K (1100 °C) and low [AlCl]:[SiCl{sub 4}] ratio.

36 MATERIALS SCIENCE↗