Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Observational Possibility of the Early GRBs using a Gaseous Electron Tracking Compton Camera in sub-MeV and MeV regions

GRBs have been recently known as a unique probe to catch the highest z galaxies and stars. Here I propose the new trigger method to catch high-z GRBs with z>10 efficiently by imaging sub-MeV gamma rays from GRBs. We have developed the Electron Tracking Compton Camera (ETCC) with reconstructing tracks of the recoil electron in Compton process to explore the MeV gamma-ray astronomy. By measuring the track of a recoil electron, the direction of the incident gamma ray is determined for each photon, which enables us to reconstruct the direction of GRBs by detecting only several ten photons (>100 keV). Ability of the large ETCC (100 cm{sup 2} effective area) to detect GRBs with z{approx}20 is revealed, based on the results of the balloon experiment and laboratory imaging test using the small ETCC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling laser wakefield accelerators in a Lorentz boosted frame

Modeling of laser-plasma wakefield accelerators in an optimal frame of reference is shown to produce orders of magnitude speed-up of calculations from first principles. Obtaining these speedups requires mitigation of a high-frequency instability that otherwise limits effectiveness in addition to solutions for handling data input and output in a relativistically boosted frame of reference. The observed high-frequency instability is mitigated using methods including an electromagnetic solver with tunable coefficients, its extension to accomodate Perfectly Matched Layers and Friedman's damping algorithms, as well as an efficient large bandwidth digital filter. It is shown that choosing the frame of the wake as the frame of reference allows for higher levels of filtering and damping than is possible in other frames for the same accuracy. Detailed testing also revealed serendipitously the existence of a singular time step at which the instability level is minimized, independently of numerical dispersion, thus indicating that the observed instability may not be due primarily to Numerical Cerenkov as has been conjectured. The techniques developed for Cerenkov mitigation prove nonetheless to be very efficient at controlling the instability. Using these techniques, agreement at the percentage level is demonstrated between simulations using different frames of reference, with speedups reaching two orders of magnitude for a 0.1 GeV class stages. The method then allows direct and efficient full-scale modeling of deeply depleted laser-plasma stages of 10 GeV-1 TeV for the first time, verifying the scaling of plasma accelerators to very high energies. Over 4, 5 and 6 orders of magnitude speedup is achieved for the modeling of 10 GeV, 100 GeV and 1 TeV class stages, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization Of An EBL System: The Influence Of Process Parameters On Thickness Resist And Engraving Shapes

In LIGA process, the low flexibility due to the use of masks might be overcome using the electron beam of a scansion electron microscope (SEM) instead of the synchrotron radiation. In this way, through the vector control of the beam, it is possible to irradiate a specific path on the resist without using any mask. Anyway, it is important to remark that the Electron Beam Lithography (EBL) can not include all the applications of the X-ray LIGA technique but it could be a valid alternative only for some specific uses. In particular, some limits concerning the impression of high thickness resists are expected. An EBL system based on a SEM was recently implemented by the authors and some tests were carried out to characterize the device performances. Aim of this work is to asses the system performances in terms of maximum impressible thickness resist and shape of the engraved entities. Several tests were carried out by varying the resist thickness and the process parameters.

07 ISOTOPE AND RADIATION SOURCES↗

Jets and Heavy Flavors at HERA

Recent results on jet cross sections and heavy-flavor production in photoproduction and neutral current deep inelastic ep scattering from the H1 and ZEUS Collaborations are presented. The jet measurements are used to perform stringent tests of perturbative QCD, to extract precise values of the strong coupling and to constrain further the proton and photon parton distribution functions. The measurement of beauty and charm production at HERA is an important testing ground for perturbative QCD and can provide information on the structure of the proton.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Minimization of nanosatellite low frequency magnetic fields

Small weight and dimensions of the micro- and nanosatellites constrain researchers to place electromagnetic sensors on short booms or on the satellite body. Therefore the electromagnetic cleanliness of such satellites becomes a central question. This paper describes the theoretical base and practical techniques for determining the parameters of DC and very low frequency magnetic interference sources. One of such sources is satellite magnetization, the reduction of which improves the accuracy and stability of the attitude control system. We present design solutions for magnetically clean spacecraft, testing equipment, and technology for magnetic moment measurements, which are more convenient, efficient, and accurate than the conventional ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bell-inequality tests with macroscopic entangled states of light

Quantum correlations may violate the Bell inequalities. Most experimental schemes confirming this prediction have been realized in all-optical Bell tests suffering from the detection loophole. Experiments which simultaneously close this loophole and the locality loophole are highly desirable and remain challenging. An approach to loophole-free Bell tests is based on amplification of the entangled photons (i.e., on macroscopic entanglement), for which an optical signal should be easy to detect. However, the macroscopic states are partially indistinguishable by classical detectors. An interesting idea to overcome these limitations is to replace the postselection by an appropriate preselection immediately after the amplification. This is in the spirit of state preprocessing revealing hidden nonlocality. Here, we examine one of the possible preselections, but the presented tools can be used for analysis of other schemes. Filtering methods making the macroscopic entanglement useful for Bell tests and quantum protocols are the subject of an intensive study in the field nowadays.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On refractive processes in strong laser field quantum electrodynamics

Refractive processes in strong-field QED are pure quantum processes, which involve only external photons and the background electromagnetic field. We show analytically that such processes occurring in a plane-wave field and involving external real photons are all characterized by a surprisingly modest net exchange of energy and momentum with the laser field, corresponding to a few laser photons, even in the limit of ultra-relativistic laser intensities. We obtain this result by a direct calculation of the transition matrix element of an arbitrary refractive QED process and accounting exactly for the background plane-wave field. A simple physical explanation of this modest net exchange of laser photons is provided, based on the fact that the laser field couples with the external photons only indirectly through virtual electron–positron pairs. For stronger and stronger laser fields, the pairs cover a shorter and shorter distance before they annihilate again, such that the laser can transfer to them an energy corresponding to only a few photons. These results can be relevant for the future experiments aiming to test strong-field QED at present and next-generation facilities. -- Highlights: •Investigation of the one-loop amplitude of refractive QED processes in a laser field. •The amplitude is suppressed for a large number of net-exchanged laser photons. •Suggestion for first observation of high-nonlinear vacuum effects in a laser field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cerenkov radio pulses from electromagnetic showers in the time domain

The electric field of the Cerenkov radio pulse produced by a single charged particle track in a dielectric medium is derived from first principles. An algorithm is developed to obtain the pulse in the time domain for numerical calculations. The algorithm is implemented in a Monte Carlo simulation of electromagnetic showers in dense media (specifically designed for coherent radio emission applications) as might be induced by interactions of ultrahigh energy neutrinos. The coherent Cerenkov radio emission produced by such showers is obtained simultaneously both in the time and frequency domains. A consistency check performed by Fourier transforming the pulse in time and comparing it to the frequency spectrum obtained directly in the simulations yields, as expected, fully consistent results. The reversal of the time structure inside the Cerenkov cone and the signs of the corresponding pulses are addressed in detail. The results, besides testing algorithms used for reference calculations in the frequency domain, shed new light into the properties of the radio pulse in the time domain. The shape of the pulse in the time domain is directly related to the depth development of the excess charge in the shower and its width to the observation angle with respect to the Cerenkov direction. This information can be of great practical importance for interpreting actual data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma generation for controlled microwave-reflecting surfaces in plasma antennas

The idea of replacing metal antenna elements with equivalent plasma objects has long been of interest because of the possibility of switching the antenna on and off. In general, two kinds of designs have so far been reported: (a) Separate plasma “wires” which are thin glass tubes filled with gas, where plasma appears due to discharge inside. (b) Reflecting surfaces, consisting of tightly held plasma wires or specially designed large discharge devices with magnetic confinement. The main disadvantages of these antennas are either large weight and size or too irregular surfaces for proper reflection. To design a microwave plasma antenna in the most common radar wavelength range of 1–3 cm with a typical gain of 30 dB, a smooth plasma mirror having a 10–30 cm diameter and a proper curvature is required. The plasma density must be 10{sup 12}–10{sup 14} cm{sup −3} in order to exceed the critical density for the frequency of the electromagnetic wave. To achieve this we have used a ferromagnetic inductively coupled plasma (FICP) source, where a thin magnetic core of a large diameter is fully immersed in the plasma. In the present paper, we show a way to adapt the FICP source for creating a flat switchable microwave plasma mirror with an effective diameter of 30 cm. This mirror was tested as a microwave reflector and there was found no significant difference when compared with a copper plate having the same diameter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

El-CID: a filter for gravitational-wave electromagnetic counterpart identification

ABSTRACT As gravitational-wave (GW) interferometers become more sensitive and probe ever more distant reaches, the number of detected binary neutron star mergers will increase. However, detecting more events farther away with GWs does not guarantee corresponding increase in the number of electromagnetic counterparts of these events. Current and upcoming wide-field surveys that participate in GW follow-up operations will have to contend with distinguishing the kilonova (KN) from the ever increasing number of transients they detect, many of which will be consistent with the GW sky-localization. We have developed a novel tool based on a temporal convolutional neural network architecture, trained on sparse early-time photometry and contextual information for Electromagnetic Counterpart Identification (El-CID). The overarching goal for El-CID is to slice through list of new transient candidates that are consistent with the GW sky localization, and determine which sources are consistent with KNe, allowing limited target-of-opportunity resources to be used judiciously. In addition to verifying the performance of our algorithm on an extensive testing sample, we validate it on AT2017gfo – the only EM counterpart of a binary neutron star merger discovered to date – and AT2019npv – a supernova that was initially suspected as a counterpart of the GW event, GW190814, but was later ruled out after further analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-H-BRA-07: Design, Construction, and Installation of An Experimental Beam Line for the Development of MRI-Linac Compatible Electron Accelerator

Purpose: MRI guided radiation therapy (MRIgRT) is a rapidly growing field; however, Linac operation in MRI fringe fields represents an ongoing challenge. We have previously shown in-silico that Linacs could be redesigned to function in the in-line orientation with no magnetic shielding by adopting an RF-gun configuration. Other authors have also published insilico studies of Linac operation in magnetic fields; however to date no experimental validation data is published. This work details the design, construction, and installation of an experimental beam line to validate our in-silico results. Methods: An RF-gun comprising 1.5 accelerating cells and capable of generating electron energies up to 3.2MeV is used. The experimental apparatus was designed to monitor both beam current (toroid current monitor), spot size (two phosphor screens with viewports), and generate peak magnetic fields of at least 1000G (three variable current electromagnetic coils). Thermal FEM simulations were developed to ensure coil temperature remained within 100degC. Other design considerations included beam disposal, vacuum maintenance, radiation shielding, earthquake safety, and machine protection interlocks. Results: The beam line has been designed, built, and installed in a radiation shielded bunker. Water cooling, power supplies, thermo-couples, cameras, and radiation shielding have been successfully connected and tested. Interlock testing, vacuum processing, and RF processing have been successfully completed. The first beam on is expected within weeks. The coil heating simulations show that with care, peak fields of up to 1200G (320G at cathode) can be produced using 40A current, which is well within the fields expected for MRI-Linac systems. The maximum coil temperature at this current was 84degC after 6 minutes. Conclusion: An experimental beam line has been constructed and installed at SLAC in order to experimentally characterise RF gun performance in in-line magnetic fields, validate in-silico design work, and provide the first published experimental data relating to accelerator functionality for MRIgRT.

43 PARTICLE ACCELERATORS↗

Status of the endcap BGO calorimeter of the CMD-3 detector

The electromagnetic endcap BGO calorimeter of the CMD-3 detector is ready for experiments at the new e{sup +}e{sup -} collider VEPP-2000. Light readout is performed by silicon photodiodes. A thermalcontrol system that is able to maintain the calorimeter temperature at a level of 12 {+-}1 deg. C was designed and manufactured. All blocks of the endcap calorimeter are assembled, tested, and prepared for installing at the detector.

43 PARTICLE ACCELERATORS↗

Transfer learning for metamaterial design and simulation

Abstract We demonstrate transfer learning as a tool to improve the efficacy of training deep learning models based on residual neural networks (ResNets). Specifically, we examine its use for study of multi-scale electrically large metasurface arrays under open boundary conditions in electromagnetic metamaterials. Our aim is to assess the efficiency of transfer learning across a range of problem domains that vary in their resemblance to the original base problem for which the ResNet model was initially trained. We use a quasi-analytical discrete dipole approximation (DDA) method to simulate electrically large metasurface arrays to obtain ground truth data for training and testing of our deep neural network. Our approach can save significant time for examining novel metasurface designs by harnessing the power of transfer learning, as it effectively mitigates the pervasive data bottleneck issue commonly encountered in deep learning. We demonstrate that for the best case when the transfer task is sufficiently similar to the target task, a new task can be effectively trained using only a few data points yet still achieve a test mean absolute relative error of 3 % with a pre-trained neural network, realizing data reduction by a factor of 1000.

Peng, Rixi↗

Fusion Energy Science Joint Facilities and Theory Research Target 2011: Final Report for the Period October 1, 2010 through September 30, 2011

Briefly stated, the goal of this combined experiment/theory milestone was to improve our knowledge of the physics processes that control the H-mode pedestal by applying models of these mechanisms to experimental data. A concerted and coordinated effort of experimental, theory and modeling activities has examined several physics mechanisms of interest, and has met the goals of the milestone. A few noteworthy results will be noted here. The activity has applied peeling-ballooning theory to all three machines, and increased confidence that the theory predicts the ultimate limits to pedestal height in an ELMing plasma. The activity has expanded the range of conditions for testing of the EPED model, and increased confidence in the ability of the model to compute the pedestal pressure height in medium aspect ratio tokamaks. Kinetic neoclassical models have been used to verify that an important analytic model for the pedestal bootstrap current has good accuracy in many regimes of interest but needs correction at high collisionality. A benchmarking effort between electromagnetic gyrokinetic codes has provided increased understanding of how to use these codes in the pedestal, and has laid the groundwork for using these codes to study linear stability of gyrokinetic modes in and on top of the pedestal. Comparisons of data and models have led to successful simulations of a quasi-coherent mode in C-Mod and to the tentative identification of a high frequency mode in DIII-D. A kinetic neoclassical model qualitatively agrees with some features of pedestal density profiles. A paleoclassical transport model quantitatively predicts some features of the electron temperature profiles in NSTX and DIII-D. The milestone activity also laid the groundwork for future advancements in understanding and predicting the pedestal. All three machines obtained a wealth of pedestal data under a wide variety of operating conditions. Some of these data have been analyzed already, and the analysis and comparison with models will provide important results over the next year or two. Many codes were improved in significant ways in order to model data under the challenging conditions of the pedestal. In addition, new and strengthened collaborations were established between experiment, modeling and theory, and these efforts include providing mechanisms for sharing experimental data. All of these efforts will continue to provide major benefits to future pedestal studies. Much of the experimental and modeling work performed to support this milestone is reported in detail in the research contributions to this report. Here, a summary of results from the various contributions, as they pertain to several proposed pedestal physics processes, is discussed here. Emphasis is placed on mechanisms for which there are results from one or more machines or one or more models. Work from preceding quarterly reports is used for some of this summary. At the end of this summary, a brief summary of implications for ITER and implications for future work will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of GEANT4 very low energy cross section models with experimental data in water

Purpose: The GEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (H{sup 0}, H{sup +}) and (He{sup 0}, He{sup +}, He{sup 2+}), respectively, in liquid water, the main component of biological systems, down to the electron volt regime and the submicrometer scale, providing GEANT4 users with the so-called ''GEANT4-DNA'' physics models suitable for microdosimetry simulation applications. The corresponding software has been recently re-engineered in order to provide GEANT4 users with a coherent and unique approach to the simulation of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature. Methods: An evaluation of the closeness between the total and differential cross section models available in the GEANT4 toolkit for microdosimetry and experimental reference data is performed using a dedicated statistical toolkit that includes the Kolmogorov-Smirnov statistical test. The authors used experimental data acquired in water vapor as direct measurements in the liquid phase are not yet available in the literature. Comparisons with several recommendations are also presented. Results: The authors have assessed the compatibility of experimental data with GEANT4 microdosimetry models by means of quantitative methods. The results show that microdosimetric measurements in liquid water are necessary to assess quantitatively the validity of the software implementation for the liquid water phase. Nevertheless, a comparison with existing experimental data in water vapor provides a qualitative appreciation of the plausibility of the simulation models. The existing reference data themselves should undergo a critical interpretation and selection, as some of the series exhibit significant deviations from each other. Conclusions: The GEANT4-DNA physics models available in the GEANT4 toolkit have been compared in this article to available experimental data in the water vapor phase as well as to several published recommendations on the mass stopping power. These models represent a first step in the extension of the GEANT4 Monte Carlo toolkit to the simulation of biological effects of ionizing radiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

The scintillator surface detector of the Pierre Auger observatory

Data collected so far by the Pierre Auger Observatory have enabled major advances in ultra-high energy cosmic ray physics and demonstrated that improved determination of masses of primary cosmic-ray particles, preferably on an event-by-event basis, is necessary for understanding their origin and nature. Improvement in primary mass measurements was the main motivation for the upgrade of the Pierre Auger Observatory, called AugerPrime. As part of this upgrade, scintillator detectors are added to the existing water-Cherenkov surface detector stations. By making use of the differences in detector response to the electromagnetic particles and muons between scintillator and water-Cherenkov detectors, the electromagnetic and muonic components of cosmic-ray air showers can be disentangled. Since the muonic component is sensitive to the primary mass, such combination of detectors provides a powerful way to improve primary mass composition measurements over the original Auger surface detector design. In this paper, the so-called Scintillator Surface Detectors are discussed, including their design characteristics, production process, testing procedure and deployment in the field.

Detector design and construction technologies and ↗

Absorption of Axion Dark Matter in a Magnetized Medium

Detection of axion dark matter heavier than an meV is hindered by its small wavelength, which limits the useful volume of traditional experiments. This problem can be avoided by directly detecting in-medium excitations, whose ∼ meV – eV energies are decoupled from the detector size. We show that for any target inside a magnetic field, the absorption rate of electromagnetically coupled axions into in-medium excitations is determined by the dielectric function. As a result, the plethora of candidate targets previously identified for sub-GeV dark matter searches can be repurposed as broadband axion detectors. We find that a kg yr exposure with noise levels comparable to recent measurements is sufficient to probe parameter space currently unexplored by laboratory tests. Noise reduction by only a few orders of magnitude can enable sensitivity to the QCD axion in the ∼ 10 meV – 10 eV mass range. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗