Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Storage System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Clemson Hydrogen Combined Heat and Power Storage System

The objective of this project named H2 Orange, was to develop a conceptual design including a technoeconomic study, technology gap assessment and maturation plan, and commercialization plan of a nominal 50-megawatt hours (MWh) hydrogen energy storage system. The project investigated how to optimally size, design and integrate the hydrogen energy storage system with an existing 14.3-megawatt (MW) gas turbine fossil asset supplying thermal power at the Clemson University Combined Heat & Power (CHP) plant.

03 NATURAL GAS↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks: Q1 2021

Based on our bottom-up modeling, the Q1 2021 PV and energy storage cost benchmarks are: $\$2.65$ per watt DC (WDC) (or $\$3.05$/WAC) for residential PV systems, 1.56/WDC (or $\$1.79$/WAC) for commercial rooftop PV systems, $\$1.64$/WDC (or $\$1.88$/WAC) for commercial ground-mount PV systems, $\$0.83$/WDC (or $\$1.13$/WAC) for fixed-tilt utility-scale PV systems, $\$0.89$/WDC (or $\$1.20$/WAC) for one-axis-tracking utility-scale PV systems, $\$30,326$-$\$33,618$ for a 7.15-kWDC residential PV system with 5 kW/12.5 kWh nameplate of storage, $\$2.04$ - $\$2.10$ million for a 1-MWDC commercial ground-mount PV system colocated with 600 kW/2.4 MWhusable of storage, $\$166$ - $\$167$ million for a 100-MWDC one-axis tracker PV system colocated with 60 MW/240 MWhusable of storage. Between 2020 and 2021, there were 3.3% ($\$0.0$9/W), 10.7% ($\$0.19$/W), and 12.3% ($\$0.13$/W) reductions (in 2020 USD) in the residential, commercial rooftop, and utility-scale (one-axis) PV system cost benchmarks respectively. Balance of system (BOS) costs have either increased or remained flat across sectors, year-on-year, unlike in previous benchmark reports, which generally have reported declining BOS costs. The increase in BOS cost has been offset by a 17% reduction in module cost. Overall, modeled PV installed costs across the three sectors have declined compared to our Q1 2020 system costs.

14 SOLAR ENERGY↗

The Role of Energy Storage in Commercial Building

Motivation and Background of Study This project was motivated by the need to understand the full value of energy storage (thermal and electric energy storage) in commercial buildings, the opportunity of benefits for building operations and the potential interactions between a building and a smart grid infrastructure. On-site or local energy storage systems are not new to the commercial building sector; they have been in place in US buildings for decades. Most building-scale storage technologies are based on thermal or electrochemical storage mechanisms. Energy storage technologies are not designed to conserve energy, and losses associated with energy conversion are inevitable. Instead, storage provides flexibility to manage load in a building or to balance load and generation in the power grid. From the building owner's perspective, storage enables load shifting to optimize energy costs while maintaining comfort. From a grid operations perspective, building storage at scale could provide additional flexibility to grid operators in managing the generation variability from intermittent renewable energy resources (wind and solar). To characterize the set of benefits, technical opportunities and challenges, and potential economic values of storage in a commercial building from both the building operation's and the grid operation's view-points is the key point of this project. The research effort was initiated in early 2010 involving Argonne National Laboratory (ANL), the National Renewable Energy Laboratory (NREL), and Pacific Northwest National Laboratory (PNNL) to quantify these opportunities from a commercial buildings perspective. This report summarizes the early discussions, literature reviews, stakeholder engagements, and initial results of analyses related to the overall role of energy storage in commercial buildings. Beyond the summary of roughly eight months of effort by the laboratories, the report attempts to substantiate the importance of active DOE/BTP R&D activities in this space.

14 SOLAR ENERGY↗

Hybrid Turbine Electric Vehicle

Hybrid electric power trains may revolutionize today's ground passenger vehicles by significantly improving fuel economy and decreasing emissions. The NASA Lewis Research Center is working with industry, universities, and Government to develop and demonstrate a hybrid electric vehicle. Our partners include Bowling Green State University, the Cleveland Regional Transit Authority, Lincoln Electric Motor Division, the State of Ohio's Department of Development, and Teledyne Ryan Aeronautical. The vehicle will be a heavy class urban transit bus offering double the fuel economy of today's buses and emissions that are reduced to 1/10th of the Environmental Protection Agency's standards. At the heart of the vehicle's drive train is a natural-gas-fueled engine. Initially, a small automotive engine will be tested as a baseline. This will be followed by the introduction of an advanced gas turbine developed from an aircraft jet engine. The engine turns a high-speed generator, producing electricity. Power from both the generator and an onboard energy storage system is then provided to a variable-speed electric motor attached to the rear drive axle. An intelligent power-control system determines the most efficient operation of the engine and energy storage system.

Viterna, Larry A.↗

Power Quality and Stability in a Cluster of Microgrids with Coordinated Power and Energy Management

Distributed Energy Resources (DER) such as photovoltaic (PV) systems and battery energy storage systems (BESS) can be operated collectively as microgrids. Microgrids can be effective in meeting local load requirements as well as in improving the power quality and stability in a modern power distribution system. Multiple microgrids can also be operated in a coordinated manner as a cluster, to improve the resiliency of the power distribution system. In the event of an outage caused by a transmission system failure, the microgrids in a cluster can use their distributed generation capacity and energy storage resources to recover and extend power availability to the critical loads in the system. In this paper, an illustrative cluster of two microgrids based on the IEEE 13-bus model with DERs has been used, to demonstrate the operation of the concept using real-time simulations. Using real-time simulations, capabilities such as switching reconfiguration following faults, identification of optimal DER placement for effective power quality management, and power electronic controller validation have been demonstrated. For the two-microgrid cluster, this paper also presents improvements in load voltage quality and

Chowdhury, Prithwiraj Roy↗

Bi-Directional DC-DC Converter for PHEV Applications

Plug-In Hybrid Electric Vehicles (PHEV) require high power density energy storage system (ESS) for hybrid operation and high energy density ESS for Electric Vehicle (EV) mode range. However, ESS technologies to maximize power density and energy density simultaneously are not commercially feasible. The use of bi-directional DC-DC converter allows use of multiple energy storage, and the flexible DC-link voltages can enhance the system efficiency and reduce component sizing. This will improve fuel consumption, increase the EV mode range, reduce the total weight, reduce battery initial and life cycle cost, and provide flexibility in system design.

25 ENERGY STORAGE↗

Methods and systems for thermal energy storage and their use in buildings applications

The present disclosure relates to particle-based thermal energy storage (TES) systems employed for the heating and cooling applications for residential and/or commercial buildings. Particle-based TES systems may store thermal energy in the particles during off-peak times (i.e., when electricity demand and/or costs are relatively low) and remove the stored thermal energy for heating or cooling applications for buildings during peak times (i.e., when electricity demand and/or costs are relatively high).

Ma, Zhiwen↗

Flywheel Energy Storage - Dynamic Modeling

A flywheel energy storage systems (FESS) is suitable for high-power, low-energy content to deliver or absorb power in surges. This type of application is very suitable for frequency regulation in an electric grid. In addition, a modern FESS is built as a high-efficiency, high-speed motor/generator drive system that employs modern power electronics, therefore, the power quality of the grid-connected output is excellent. In addition, a FESS is very valuable to delivering ancillary services to the grid, and it can contribute reactive power compensation. Thus, a FESS can maintain high reliability in power systems by providing ride-through capability to the power system area while the rest of the generating fleet, which has a slower response in the power system, performs primary and secondary frequency response to the grid. A FESS has several advantages compared to a chemical-based energy storage (CBES) system, namely: it has high energy density and durability, and it can be cycled frequently without impacting performance. The response of FESS is faster than that of a CBES. Also, unlike some CBES, FESS has the same performance regardless of the number of cycles of charging/discharging performed throughout its lifetime.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a frequency regulation duty-cycle for standardized energy storage performance testing

The US DOE Protocol for uniformly measuring and expressing the performance of energy storage systems, first developed in 2012 through inclusive working group activities, provides standardized methodologies for evaluating an energy storage system’s ability to supply specific services to electrical grids. This article elaborates on the data and decisions behind the duty-cycle used for frequency regulation in this protocol. Analysis of a year of publicly available frequency regulation control signal data from a utility was considered in developing the representative signal for this use case. Moreover, this showed that signal standard deviation can be used as a metric for aggressiveness or rigor. From these data, we select representative 2 h long signals that exhibit nearly all of dynamics of actual usage under two distinct regimens, one for average use and the other for highly aggressive use. Our results were combined into a 24-h duty-cycle comprised of average and aggressive segments. The benefits and drawbacks of the selected duty-cycle are discussed along with its potential implications to the energy storage industry.

25 ENERGY STORAGE↗

A Novel Resilience-Oriented Cellular Grid Formation Approach for Distribution Systems with Behind-the-Meter Distributed Energy Resources

This paper presents a resilience-oriented cellular grid formation approach to achieve scalable and reconfigurable community microgrid operations for distribution systems with behind-the-meter distributed energy resources. A set of interconnected solar photovoltaics, energy storage systems, and load is termed as a cell, implying a subset of the grid that can operate independently using its own resources. Cells are identified such that each cell inherently has sufficient energy resources to black start and can provide a certain level of backup power for its load under the loss of utility power supply. The proposed cell formation approach builds on a unique self-organizing map-based method (SomRes) to quantify a system's resilience. Using SomRes and a non-dominated sorting-based genetic algorithm (NSGA-II), a fast and efficient cell formation algorithm is developed to identify cells in a distribution system that are resilient against extreme events. The efficacy of the proposed approach is demonstrated on a numerical model of a real distribution feeder in Colorado, United States.

distributed energy resource↗

Hierarchically Structured Materials for Lithium Batteries

Lithium-ion battery (LIB) is one of the most promising power sources to be deployed in electric vehicles (EV), including solely battery powered vehicles, plug-in hybrid electric vehicles, and hybrid electrical vehicles. With the increasing demand on devices of high energy densities (>500 Wh/kg) , new energy storage systems, such as lithium-oxygen (Li-O2) batteries and other emerging systems beyond the conventional LIB also attracted worldwide interest for both transportation and grid energy storage applications in recent years. It is well known that the electrochemical performances of these energy storage systems depend not only on the composition of the materials, but also on the structure of electrode materials used in the batteries. Although the desired performances characteristics of batteries often have conflict requirements on the micro/nano-structure of electrodes, hierarchically designed electrodes can be tailored to satisfy these conflict requirements. This work will review hierarchically structured materials that have been successfully used in LIB and Li-O2 batteries. Our goal is to elucidate 1) how to realize the full potential of energy materials through the manipulation of morphologies, and 2) how the hierarchical structure benefits the charge transport, promotes the interfacial properties, prolongs the electrode stability and battery lifetime.

energy storage↗

Energy Storage Improves Power Plant Flexibility and Economic Performance

Most existing coal-fired power plants were designed for sustained operation at full load to maximize efficiency, reliability, and revenue, as well as to operate air pollution control devices at design conditions. Depending on plant type and design, these plants can adjust output within a fixed range in response to plant operating or market conditions. The need for flexibility driven by increased penetration of variable and non-dispatchable power generation, such as wind and solar, is shifting the traditional mission profile of thermoelectric power plants in three ways: more frequent shutdowns when market or grid conditions warrant, more aggressive load ramp rates (rate of output change), and a lower minimum sustainable load, which provides a wider operating range and helps avoid costly plant shutdowns. Recent studies have shown that the flexibility of a coal-fired power plant can be improved by energy storage. The objective of this work was to analyze a set of energy storage options and determine their impact on the flexibility and economics of a representative coal-fired power plant. The effect of three energy storage systems integrated with a coal power plant on plant flexibility and economics was investigated. The results obtained in this project show that energy storage systems integrated with a thermal power plant improve plant flexibility and participation in the energy and ancillary services markets, which improves plant financial performance.

20 FOSSIL-FUELED POWER PLANTS↗

THE WIDE-AREA ENERGY STORAGE AND MANAGEMENT SYSTEM PHASE II Final Report - Flywheel Field Tests

This research was conducted by Pacific Northwest National Laboratory (PNNL) operated for the U.S. department of Energy (DOE) by Battelle Memorial Institute for Bonneville Power Administration (BPA), California Institute for Energy and Environment (CIEE) and California Energy Commission (CEC). A wide-area energy management system (WAEMS) is a centralized control system that operates energy storage devices (ESDs) located in different places to provide energy and ancillary services that can be shared among balancing authorities (BAs). The goal of this research is to conduct flywheel field tests, investigate the technical characteristics and economics of combined hydro-flywheel regulation services that can be shared between Bonneville Power Administration (BPA) and California Independent System Operator (CAISO) controlled areas. This report is the second interim technical report for Phase II of the WAEMS project. This report presents: 1) the methodology of sharing regulation service between balancing authorities, 2) the algorithm to allocate the regulation signal between the flywheel and hydro power plant to minimize the wear-and-tear of the hydro power plants, 3) field results of the hydro-flywheel regulation service (conducted by the Beacon Power), and 4) the performance metrics and economic analysis of the combined hydro-flywheel regulation service.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmark: Q1 2021 [Slides]

Our benchmarking method includes bottom-up accounting for all necessary system and projectdevelopment costs incurred when installing residential, commercial, and utility-scale systems, and it models the Q1 2021 costs for such systems, excluding any previous supply agreements or contracts. In general, we attempt to model the typical installation techniques and business operations from an installed-cost perspective, and our benchmarks are national averages. The residential PV-only benchmark and the commercial rooftop PV-only benchmark average costs by inverter type (string inverters, string inverters with direct current [DC] optimizers, and microinverters), weighted by inverter market share. The residential PV-only benchmark is further averaged across small installer and national integrator business models, weighted by market share. All benchmarks include variations—accounting for the differences in size, equipment, and operational use (particularly for storage)—that are currently available in the marketplace. All benchmarks assume nonunionized construction labor; residential and commercial PV systems predominantly use nonunionized labor, and the type of labor required for utility-scale PV systems depends heavily on the development process. All benchmarks assume the use of monofacial monocrystalline silicon PV modules. Benchmarks using cadmium telluride or bifacial modules could result in significantly different results. The data in this annual benchmark report inform the formulation of and track progress toward the U.S. Department of Energy (DOE) Solar Energy Technologies Office’s Government Performance and Reporting Act cost targets.

14 SOLAR ENERGY↗

Performance of Energy Storage with Nuclear and Renewable Power Systems

Nuclear power represents a traditional baseload power component to the grid, while renewables output variable amounts of power at unpredictable times. Nuclear and renewable energy integration (NREI) systems have previously been explored as valuable additions to the existing power grid. Energy storage systems can allow power plants to store energy mechanically using pumped hydro or compressed air, thermally using liquid salt or steam accumulators, or chemically with batteries. The addition of energy storage to NREI systems can allow for the discharge of electricity to adjust to demands placed on the grid. The allocation of energy to adjust to grid demand is explored through a historical 8,760-hour analysis including nuclear, wind, and solar NREI systems with energy storage. The operation of storage systems is compared through simulations of different storage and discharge parameters based off the maximum daily grid demands, and hourly electricity prices. The overall profitability of storage systems is determined by comparing simulation results for the overall net revenue increases exceeding storage efficiency losses. Several NREI systems have increased the value of electricity for both solar PV and wind energy, in combination with nuclear power. Optimization of these systems is developed using MATLAB code and the simulations of the most profitable results are explored.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Toward High-Voltage Cathodes for Zinc-Ion Batteries: Discovery Pipeline and Material Design Rules

Efficient energy storage systems are crucial to address the intermittency of renewable energy sources. As multivalent batteries, Zn-ion batteries (ZIBs), while inherently low voltage, offer a promising low-cost alternative to Li-ion batteries due to the viable use of zinc as the anode. However, to maximize the potential impact of ZIBs, rechargeable cathodes with improved Zn diffusion are needed. To better understand the chemical and structural factors influencing Zn-ion mobility within battery electrode materials, we employ a high-throughput computational screening approach to systematically evaluate candidate intercalation hosts for ZIB cathodes, expanding the chemical search space on empty intercalation hosts that do not contain Zn. We leverage a high-throughput screening funnel to identify promising cathodes in ZIBs, integrating screening criteria with density functional theory (DFT)-based calculations of Zn2+ intercalation and diffusion inside the host materials. Using these data, we identify the design principles that favor Zn-ion mobility in candidate cathode materials. Building on previous work on divalent-ion cathodes, this study broadens the chemical space for next-generation multivalent energy storage systems.

electrodes↗

Powertrain Controls Optimization for HD Hybrid Line Haul Trucks - FY2014 Annual Report

This is a vehicle system level project, encompassing analytical modeling and supervisory controls development as well as experimental verification/validation testing at the component, powertrain, and full vehicle system level. This project supports the goal of petroleum consumption reduction for medium and heavy trucks through the development of advanced hybrid technologies and control systems. VSST has invested previously in R&D to support hybrid energy storage systems (Li-ion plus ultra-caps) for light duty, passenger car applications. This research will be extended to the MD and HD sector where current battery technology is not mature enough to handle the substantial regenerative braking power levels these trucks are capable of producing. With this hybrid energy storage system, substantial gains in overall vehicle efficiency are possible. In addition, advanced combustion technologies, such as RCCI, will be implemented into an advanced hybrid powertrain for a Class 8 line haul application. This powertrain, leveraged from other VSST work (Meritor, a current ORNL/VSST partner), is ideal for taking advantage of the benefits of RCCI operation due to its series hybrid mode of operation. Emissions control is also a focus of this project, especially due to the fact that RCCI creates a low temperature exhaust stream that must addressed.

33 ADVANCED PROPULSION SYSTEMS↗