Search NASASearch

SEARCH · Search NASA

Results for “Engineering - Instrumentation related to nuclear science and technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,581 records · Page 52

A Laboratory Breadboard System for Dual-Arm Teleoperation

The computing architecture of a novel dual-arm teleoperation system is described. The novelty of this system is that: (1) the master arm is not a replica of the slave arm; it is unspecific to any manipulator and can be used for the control of various robot arms with software modifications; and (2) the force feedback to the general purpose master arm is derived from force-torque sensor data originating from the slave hand. The computing architecture of this breadboard system is a fully synchronized pipeline with unique methods for data handling, communication and mathematical transformations. The computing system is modular, thus inherently extendable. The local control loops at both sites operate at 100 Hz rate, and the end-to-end bilateral (force-reflecting) control loop operates at 200 Hz rate, each loop without interpolation. This provides high-fidelity control. This end-to-end system elevates teleoperation to a new level of capabilities via the use of sensors, microprocessors, novel electronics, and real-time graphics displays. A description is given of a graphic simulation system connected to the dual-arm teleoperation breadboard system. High-fidelity graphic simulation of a telerobot (called Phantom Robot) is used for preview and predictive displays for planning and for real-time control under several seconds communication time delay conditions. High fidelity graphic simulation is obtained by using appropriate calibration techniques.

A K Bejczy

A Battery Charger and State of Charge Indicator

A battery charger which has a full wave rectifier in series with a transformer isolated 20 kHz dc-dc converter with high frequency switches, which are programmed to actively shape the input dc line current to be a mirror image of the ac line voltage is discussed. The power circuit operates at 2 kW peak and 1 kW average power. The BC/SCI has two major subsystems: (1) the battery charger power electronics with its controls; and (2) a microcomputer subsystem which is used to acquire battery terminal data and exercise the state of charge software programs. The state of charge definition employed is the energy remaining in the battery when extracted at a 10 kW rate divided by the energy capacity of a fully charged new battery. The battery charger circuit is an isolated boost converter operating at an internal frequency of 20 kHz. The switches selected for the battery charger are the single most important item in determining its efficiency. The combination of voltage and current requirements dictate the use of high power NPN Darlington switching transistors. The power circuit topology is a three switch design which utilizes a power FET on the center tap of the isolation transformer and the power Darlingtons on each of the two ends. An analog control system is employed to accomplish active input current waveshaping as well as the necessary regulation.

Latos, T. S.

Synthetic battery cycling

The use of interactive computer graphics is suggested as an aid in battery system development. Mathematical representations of simplistic but fully representative functions of many electrochemical concepts of current practical interest will permit battery level charge and discharge phenomena to be analyzed in a qualitative manner prior to the assembly and testing of actual hardware. This technique is a useful addition to the variety of tools available to the battery system designer as he bridges the gap between interesting single cell life test data and reliable energy storage subsystems.

Thaller, L. H.

Fluid-Thermal-Structural Interactions Induced by an Asymmetric Shock-Wave/Boundary-Layer Interaction in a Mach-6 Compression Corner

An experimental study is conducted of the fluid-thermal-structural interaction of a clamped compliant panel exposed to a three dimensional shock-wave/boundary-layer interaction (SWBLI) induced by a Mach-6 compression ramp with a spanwise nonuniform incoming boundary layer. The nonuniform boundary layer was produced by placing trips on one side of the upstream flat plate, resulting in largely turbulent flow on the tripped side and transitional flow on the untripped side. Measurements of the flowfield confirmed that the tripped boundary layer contained elevated levels of unsteadiness, and the SWBLI was observed to vary from attached to fully separated as the ramp angle was increased from 10◦ to 38◦; the separation region on the tripped side of the panel was noticeably smaller, showing the elevated turbulence levels of the tripped-side flow to remain relatively localized rather than diffusing across the whole model. Full-field, time-resolved panel deformations were measured using high-speed photogrammetry and the vibrational response at each compression angle was characterized. Although the measured modes conformed largely to those from classical clamped-plate theory, some skewing of the mode shapes was observed. IR thermography highlighted regions of the compliant region where elevated temperatures were likely to promote thermal softening effects to the transient panel response. The quasi-static deformation and stress field was used to characterize the internal stress factor of each mode and showed a meaningful relationship between transient panel response and stress contained within each mode: modes with antinodes lying in high-stress areas of the plate tended to exhibit increases in vibrational frequency and decreases in vibrational power, whereas the opposite was true for modes with antinodes in low-stress areas.

Spectral Proper Orthogonal Decomposition

Battery Design and Safety

Power is essential for crewed and uncrewed spaceflight operations. Spacecraft batteries are designed and tested to be safe under extreme environmental conditions.

Melvin Abraham

A Study of the Aligned-Grid Retarding Potential Analyzer for Electric Propulsion Applications

During the development of energy analyzers for NASA’s Solar Electric Propulsion Plasma Diagnostics Package, detailed studies were performed to compare the benefits and drawbacks of different types of gridded potential analyzers. In particular, modeling and testing were performed on three types of retarding potential analyzer with aligned grids, and one type with unaligned grids. Additionally, a type of gridded energy analyzer was tested. Analyses of the model and test results showed that manufacturing an analyzer with aligned grids required greater precision and knowledge than other analyzers. A properly designed analyzer with aligned grids exhibited superior signal level, acceptance angle control, energy resolution, and compactness compared to an analyzer with unaligned grids. Additionally, the gridded energy analyzer was found to accept a broad range of incidence angles while having superior signal, energy resolution, and compactness compared to retarding potential analyzer with unaligned grid. This article describes the basic design principles deployed in the study, the associated modeling work, and the characterization tests that were performed. The article summarizes the benefits and drawbacks associated with each type of energy analyzer tested.

Electric Propulsion

A nickel-cadmium battery reconditioning circuit

The circuit presented is simple and small enough to be included in a typical battery charge/power control assembly, yet provides the advantage of a complete ground-type battery reconditioning discharge. Test results on the circuit when used to recondition two 24 cell, 20 A-h nickel-cadmium batteries are given. These results show that a battery reconditioned with this circuit returns to greater than 90 percent of its original capacity (greater than nameplate capacity) and follows a typical new battery degradation curve even after over 20,000 simulated orbital cycles for a 4 year period. Applications of the circuit are considered along with recommendations relative to its use. Its application in low voltage (22 to 36 Vdc) power systems and in high voltage (100 to 150 Vdc) power systems is discussed. The implications are that the high voltage systems have a greater need for battery reconditioning than their low voltage counterparts, and that using these circuit techniques, the expected life of a battery in low Earth orbit can be up to 5 years.

Lanier, R.

First N 2 Profile for Venus’ Deep Lower Atmosphere

We present the first N 2 profile for Venus’ deep lower atmosphere (<15 km) and a constrained isotopic composition for cloud N 2 [1]. This work directly addresses unresolved questions for Venus using legacy observations. Prior to this work, there were no reported measurements for N 2 abundances at <15 km and the isotopic composition remained unconstrained [2]. The N 2 parameters are critical to understanding the evolution and thermal properties of the atmosphere [3-7]. Our N 2 results were obtained by re-analysis of data acquired in 1978 by the Pioneer Venus Large Probe Neutral Mass Spectrometer (LNMS) [8]. The archived mass spectra from 64.2 to 0.2 km were treated using the analytical procedures specifically developed for the LNMS [9-11]. Judicious peak fitting permitted disambiguation of (A) N 2 + and CO + at 28 u and (B) 14 N 15 N+, 13 CO + , and C 2 H 5 + at 29 u. Quality controls included comparing the (A) LNMS CO + /CO 2 + ratios to the NIST database and literature and (B) fitted counts for CO + to the expected counts of CO + calculated from C 18 O + and 13 CO + using the LNMS 16 O/ 18 O and 12 C/ 13 C ratios (obtained from CO 2 ). Our results show that N 2 is uniformly mixed across the deep lower atmosphere between ~0.2 and 15 km (2.49 ± 0.10 v%). In contrast, N 2 is non-uniformly mixed across the sub-cloud atmosphere and clouds (~15–59 km), where N 2 abundances increase by ~ 2-fold between ~15 km (2.45 ± 0.32 v%) and ~59-51 km (5.21 ± 0.18 v%). Using the cloud data, we also obtained a constrained 15 N/ 14 N ratio (2.93×10 -3 ± 0.13×10 -3 ) and δ 15 N value (-204 ± 35‰). Thus, the LNMS results [1] suggest that (A) the atmosphere is unstable at <15 km, (B) N 2 is not well-mixed >15 km, and (C) the cloud δ 15 N falls between Earth and the solar wind [12, 13]. Comparisons of the N 2 abundances and isotopic compositions for nitrogen, carbon, and oxygen to other Venus measurements will be discussed.

deep lower atmosphere

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series are: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and to develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

Ben Swartout

The NASA Turbulent Heat Flux (THX) Experiments: Summary and Lessons Learned

The Turbulent Heat Flux (THX) experiments were conducted at NASA Glenn Research Center (GRC) in order to collect measurements of velocities and temperatures for computational fluid dynamics (CFD) validation of heated flows, with a focus on propulsion system components. The experiments spanned 5 phases; four of which were conducted in the GRC AeroAcoustic Propulsion Laboratory (AAPL) using the Small Hot Jet Flow Rig (SHJAR). In addition to making velocity measurements with Particle Image Velocimetry (PIV), the THX experiments introduced a new Raman-scattering based capability to measure temperatures. Computational studies were also conducted for each of the experimental configurations, in order to provide a baseline of expected CFD results and conduct an assessment of the capability of various CFD approaches for calculating flows where the turbulent transport of heat was important. Two of the collected sets of data were used for American Institute of Aeronautics and Astronautics (AIAA) Propulsion Aerodynamic Workshops (PAWs). The data set from the 5th phase, collected for heated supersonic jets, was also used to construct new validation cases for the NASA Turbulence Model Resource (TMR). This paper provides an overview of the experiments and associated computations for each of the 5 test phases. Key experimental findings are presented. Lessons learned are provided concerning the effect of computational modeling choice on accuracy of predicting turbulent flows where thermal transport is important. Emphasis is placed on comparing Reynolds-averaged Navier-Stokes approaches with large-eddy simulation approaches. The benefits of utilizing a conjugate heat transfer method in conjunction with CFD solver for film cooling is demonstrated.

RANS

Management and Performance of APPLE Battery in High Temperature Environment

India's first experimental communication satellite, APPLE, carried a 12 AH Ni-Cd battery for supplying power during eclipse. Failure to deploy one of the two solar panels resulted in the battery operating in a high temperature environment, around 40 C. This also resulted in the battery being used in diurnal cycles rather than just half yearly eclipse seasons. The management and performance of the battery during its life of two years are described. An attempt to identify the probable degradation mechanisms is also made.

Suresh, M. S.

Development and Validation of a High-Vacuum Thermal Conductivity Testbed for Aerospace Interface Materials

Thermal Interface Materials (TIMs) are critical components in spacecraft thermal management systems, where thermal performance is strongly influenced by vacuum conditions, interface contact resistance, and layered metallic joint behavior. However, manufacturer-reported thermal conductivity values are often derived under idealized conditions and may not accurately represent performance within operational aerospace applications. To address this limitation, the Testbed for Advanced Interface Materials in Vacuum (TAIMV) was developed as a modular vacuum-compatible thermal conductivity characterization platform capable of evaluating aerospace-relevant TIM configurations under both ambient and high-vacuum environments. The testbed was derived from the ASTM C1044-16 guarded hot plate methodology and incorporates interchangeable layers of stainless steel coupon geometries, independently controlled main and guard heaters, embedded resistance temperature detectors (RTDs), thermocouples, multi-layer insulation (MLI), and a temperature-controlled cold plate to characterize through-thickness thermal gradients across layered interfaces. In the current configuration, interface compression is limited to the nominal contact pressure generated by the experimental stack assembly. Initial experimental campaigns were conducted at ambient pressure and below 1×10-5 torr for vacuum cases using multiple interface materials including Braycote 601EF and Krytox-based greases across a range of thermal operating conditions. In parallel, a coupled numerical Python thermal model was developed to predict temperature distribution throughout the stack while accounting for conduction, radiation, and parasitic heat transfer pathways and effective interface resistance effects. Experimental measurements and numerical predictions showed consistent thermal trends across multiple operating conditions and environmental states. Results also revealed measurable differences between ambient and vacuum thermal behavior, demonstrating the importance of interface resistance, parasitic heat transfer mechanisms, and stack geometry in determining effective thermal performance within layered thermal interfaces. The presented work establishes a foundation for future thermal model correlation efforts and expanded characterization of aerospace thermal interface materials under representative environmental conditions. Future work will focus on the integration of a load cell system to enable controlled pressure-dependent characterization of thermal interface materials under compressive loading. This capability will allow investigation of the influence of contact pressure on effective thermal conductivity, interface resistance, and thermal performance within layered aerospace thermal interfaces under representative operational conditions.

Thermal Development Testing

NASA. Johnson Space Center primary battery applications

The role of the Power Branch/EP5 of JSC in primary battery applications is to support those JSC organizations having direct application responsibility with trade studies, battery selection recommendations, and with development, qualification, and provisioning of primary batteries. Battery subsystem management is provided. Payload hazard report preparation is supported, as is the review and comment of such reports for the JSC Payload Safety Panel, who approves the flight safety for all Orbiter payloads. JSC battery users are provided with safety analysis and test support to achieve safety approval. Finally, it is the responsibility of the Power Branch to define and maintain battery safety requirement documentation for JSC.

Bragg, Bob J.

Synthetic battery cycling

The trend in energy storage is toward systems with high-voltage and high-power outputs. These conditions accentuate the cumulative effects of small differences in characteristics from cell to cell in any large multicell battery. These considerations are of particular concern with a number of emerging electrochemical concepts where convenient overcharge reactions do not exist. The use of interactive computer graphics is suggested as an aid in battery system development. Mathematical representations of simplistic but fully representative functions of many electrochemical concepts of current practical interest will permit battery-level charge and discharge phenomena to be analyzed in a qualitative manner prior to the assembly and testing of actual hardware. This technique will be a useful addition to the variety of tools available to the battery system designer as he bridges the gap between interesting single-cell life test data and reliable energy storage subsystems.

Thaller, L. H.

The NASA Turbulent Heat Flux Experiments: Summary and Lessons Learned

The Turbulent Heat Flux (THX) experiments were conducted at NASA Glenn Research Center (GRC) in order to collect measurements of velocities and temperatures for computational fluid dynamics (CFD) validation of heated flows, with a focus on propulsion system components. The experiments spanned 5 phases; four of which were conducted in the GRC AeroAcoustic Propulsion Laboratory (AAPL) using the Small Hot Jet Flow Rig (SHJAR). In addition to making velocity measurements with Particle Image Velocimetry (PIV), the THX experiments introduced a new Raman-scattering based capability to measure temperatures. Computational studies were also conducted for each of the experimental configurations, in order to provide a baseline of expected CFD results and conduct an assessment of the capability of various CFD approaches for calculating flows where the turbulent transport of heat was important. Two of the collected sets of data were used for American Institute of Aeronautics and Astronautics (AIAA) Propulsion Aerodynamic Workshops (PAWs). The data set from the 5th phase, collected for heated supersonic jets, was also used to construct new validation cases for the NASA Turbulence Model Resource (TMR). This paper provides an overview of the experiments and associated computations for each of the 5 test phases. Key experimental findings are presented. Lessons learned are provided concerning the effect of computational modeling choice on accuracy of predicting turbulent flows where thermal transport is important. Emphasis is placed on comparing Reynolds- averaged Navier-Stokes approaches with large-eddy simulation approaches. The benefits of utilizing a conjugate heat transfer method in conjunction with CFD solver for film cooling is demonstrated.

RANS

Exploiting the Cannibalistic Traits of Reed-Solomon Codes

In Reed-Solomon codes and all other maximum distance separable codes, there is an intrinsic relationship between the size of the symbols in a codeword and the length of the codeword. Increasing the number of symbols in a codeword to improve the efficiency of the coding system thus requires using a larger set of symbols. However, long Reed-Solomon codes are difficult to implement and many communications or storage systems cannot easily accommodate an increased symbol size, e.g., M-ary frequency shift keying (FSK) and photon-counting pulse-position modulation demand a fixed symbol size. A technique for sharing redundancy among many different Reed-Solomon codewords to achieve the efficiency attainable in long Reed-Solomon codes without increasing the symbol size is described. Techniques both for calculating the performance of these new codes and for determining their encoder and decoder complexities is presented. These complexities are usually found to be substantially lower than conventional Reed-Solomon codes of similar performance.

O Collins

Battery life test using reconditioning

A discussion is presented on nickel cadmium battery life tests using reconditioning and some comparative tests not using reconditioning. The discussion is aimed at the program application part of the testing. The goals of the program were to get an increased utilization out of the battery system in geosynchronous orbit. An attempt was made to push the depth of discharge operation up around 80 to 85 percent and the intent with the reconditioning program was to extend this type of utilization out towards a 10-year life and attune the voltage regulation.

Sparks, R. H.

Copper-Wire-Card Detectors

Card Design - Each copper-wire-card detector consisted of a winding of fine wire mounted to a 1.45- by 7 .00-inch rectangular card. Two wire sizes were used - 2-mil and 3-mil (fourteen 2-mil cards and thirty-two 3-mil cards). The total exposed effective area was about 1.2 square feet (0.11 square meters). A sketch of a detector is shown in figure X-1. These detectors are similar to the detectors flown on previous satellites. Quadrant Design - The 36 cards are arranged in four groups of 12 cards each with four pairs of 3-mil cards in parallel and four single 2-mil cards in parallel. Each group is mounted on a fiber-glass support that can readily be removed from the payload for repairs or replacements with appropriate spares. Individual cards can be replaced readily if necessary. The assembly of the quadrants is shown in figure II-2. Temperature-Balance Experiment - The grids for the temperature-balance experiment were wound with insulated wire. The thermal balance of such a winding has been examined under conditions approximating flight environment. One card of 3-mil wire with a thermistor attached was enclosed in a bell jar and exposed to the sun after evacuation. External radiation was reduced by shading the bell jar except for a window which allowed the sun's rays to strike the winding. The temperature of the thermistor was recorded at intervals. Figure X-2 shows that the temperature does not rise beyond 65° C in 20 minutes of continuous exposure to the sun. Complementary tests made by Dr. Roger E. Gaumer of Lockheed Aircraft Corp. give a ratio of absorptivity to emissivity of 1 for this type of enamel insulated wire. Compensation for Resistance Changes - Temperatures at the wire-card surfaces were expected to extend from -10° C to a maximum of 60° C. Since copper has a thermal coefficient of resistance of 0.33 percent per °C, the resistance of the wire would change 22 percent and a compensator had to be provided. A 100-ohm thermistor with a negative coefficient of -3-9 percent per °C was selected, wired in parallel with a 300-ohm fixed resistor and installed in series with each 2-mil card and with each pair of 3-mil cards. The effective resistance of 2-mil and 3-mil compensated cards is shown in figure X-3 for various temperatures and compared with the resistance of uncompensated copper. The increase in resistance from 20° C to 60° C is 12 ohms or 2.7 percent. Below 20° C the effective resistance also increases and the curve is similar to that obtained for high temperatures.

Detector