Search NASA⌕ Search

SEARCH · Search NASA

Results for “Enhanced Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Dosimetry in Thermal Neutron Irradiation Facility at BMRR

Radiation dosimetry for Neutron Capture Therapy (NCT) has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF) of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR). In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1) in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2) out of core moderator remodeling, done by replacing thicker D 2 O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3) beam shutter upgrade to reduce strayed neutrons and gamma dose, (4) beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5) beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates) to reduce prompt gamma and fast neutron doses, (6) sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7) holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4 - 7 % lower than the statistical mean derived from the Monte-Carlo modeling (5% uncertainty). The dose rate measured by ion chambers was 6 - 10 % lower than the output tallies (7% uncertainty). The detailed dosimetry that was performed at the TNIF for the NCT will be described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accurate Characterization of Real Networks from Inaccurate Measurements

Our nation's dependence on information networks makes it vital to anticipate disruptions or find weaknesses in these networks. But networks like the Internet are vast, distributed, and there is no mechanism to completely collect their structure. We are restricted to specific data collection schemes (like traceroute samples from router interfaces) that examine tiny portions of such a network. It has been empirically documented and theoretically proven that these measurements have significant biases, and direct inferences from them will be wrong. But these data collection mechanisms have limited flexibility and cannot be easily modified. Moreover, in many applications there are limits on how much data can be collected. How do we make accurate inferences of network properties with biased and limited measurements? The general problem this report deals with is how to work with incompletely observed networks. We will present several different approaches to this problem. First we will present an approach to estimate the degree distribution of a graph by sampling only a small portion of the vertices. This algorithm provides provably accurate results with sublinear samples. An alternative approach would be to try to enhance the information in the by selective collecting new information by probing for neighbors of a vertex or presence of individual edges. A different setting for working with incomplete arises when we have full access to local information, but do not have any global version of the graph. Can we still identify critical nodes in such a graph? We present an approach to identify such nodes efficiently. Finally, how can we put these ideas together to identify the structure of a network? We present an approach that can complement the existing approaches for network mapping. We start with an estimate of network structure based on existing network mapping methods. Then we find a critical router in the network, use the traffic through this network to selectively collect new data to enhance our prediction.

97 MATHEMATICS AND COMPUTING↗

Atom Probe characterization of neutron irradiated commercial ZIRLO® and AXIOM X2® alloys

As part of the Mechanistic Understanding of ZIrconium Corrosion (MUZIC) program, this team has been instrumental to obtain EPRI and Westinghouse sponsorships to prepare the neutron irradiated ZIRLO® and X2® from Vogtle nuclear power plant and ship them from Studsvik’s (Sweden) hot cells to Idaho National Laboratory (INL) to be part of the NSUF library. The uniqueness of these sets of neutron irradiated alloys is that they are at the same two extremes of the fuel cycles, allowing us to study the microchemistry evolution as a function of irradiation doses, exposure time and solute content. Advanced commercial Zirconium-Niobium (Zr-Nb) alloys, such as ZIRLO® and AXIOM®, have been developed by Westinghouse to enhance the corrosion resistance of fuel cladding material for longer service time. This study specifically aims at investigating the neutron irradiation induced Nb redistribution in AXIOM® X2® to understand the effect of neutron irradiation induced microchemistry changes and the irradiation enhanced corrosion resistance observed in ZrNb alloys. The detailed sample information on chemical composition and irradiation is given in shown in Table 1a and 1b respectively. To study the neutron IIP/nanoclusters and Nb concentration in the solid solution, atom probe tomography (APT) is the primary tool to obtain reliable chemical information. APT specimens were prepared in shielded focused ion beam (FIB) at the Irradiated Materials Characterization Laboratory (IMCL) at INL followed by APT analysis at CAES facility using LEAP 4000XR

36 MATERIALS SCIENCE↗

Assessment of Weld Microstructure Through Sound Velocity Measurements for Power Plant Applications

Here, this research study employed an immersion-based micro-resolution ultrasonic velocity measurement technique (MUVT) to evaluate Grade 91 (9Cr-1Mo-V) steel welds. This process utilized a 20 MHz focused ultrasonic beam with a spot size of 250 µm, a 6 µm laser vibrometer spot size for detection, and an automated 3-axis raster scanner to accurately collect ultrasonic velocity data from two Grade 91 steel welds fabricated using cold metal transfer (CMT) and flux-cored arc welding (FCAW) processes. By analyzing the MUVT data, the Poisson’s ratio (υ) and modulus of elasticity (E), which are important mechanical properties for weldments, were calculated. The correlation between mechanical properties and ultrasonic velocity was examined. The results indicated that longitudinal ultrasonic velocity could effectively identify base metal, heat-affected zone (HAZ), and weld metal areas, showing a strong correlation with hardness. In particular, the distinctive V-shaped dip in velocity and hardness data across the HAZ areas of both samples highlighted changes in the microstructure of creep strength–enhanced ferritic steel welds. Importantly, the immersion-based MUVT demonstrated high accuracy in small sections of the weld, surpassing the conventional contact ultrasonic testing method in spatial resolution detection.

arc welding↗

Tailoring the Spin Reorientation Transition of Co Films by Pd Monolayer Capping

We have characterized the magnetization easy-axis of ultra-thin Co films (2–5 atomic layers, AL) grown on Ru(0001) when they are capped with a monolayer of Pd. The addition of a Pd monolayer turns the magnetization of 3 and 4 AL-thick Co films from an in-plane to an out-of-plane alignment, but not that of a 5 AL-thick film. These observations are explained in terms of an enhancement of the surface anisotropy. The exposure of the sample to hydrogen, CO or a combination of both gases does not overcome this effect.

Chemistry↗

Reconstructing Masses of Merging Neutron Stars from Stellar r -process Abundance Signatures

We report that neutron star mergers (NSMs) are promising astrophysical sites for the rapid neutron-capture ("r") process, but can their integrated yields explain the majority of heavy-element material in the Galaxy? One method to address this question implements a forward approach that propagates NSM rates and yields along with stellar formation rates and compares those results with observed chemical abundances of r-process-rich, metal-poor stars. In this work, we take the inverse approach by utilizing r-process-element abundance ratios of metal-poor stars as input to reconstruct the properties -especially the masses - of their neutron star (NS) binary progenitors. This novel analysis provides an independent avenue for studying the population of the original NS binary systems that merged and produced the r-process material now incorporated in Galactic metal-poor halo stars. We use ratios of elements typically associated with the limited-r-process and the actinide region to those in the lanthanide region (i.e., Zr/Dy and Th/Dy) to probe the NS masses of the progenitor merger. We find that NSMs can account for all r-process material in metal-poor stars that display r-process signatures, while simultaneously reproducing the present-day distribution of double-NS systems. Notably, with our model assumptions and the studied stellar sample, we postulate that the most r-process enhanced stars (the r–II stars) on their own would require progenitor NSMs of asymmetric systems that are distinctly different from present ones in the Galaxy. We also explore variations to the model and find that the predicted degree of asymmetry is most sensitive to the electron fraction of the remnant disk wind.

79 ASTRONOMY AND ASTROPHYSICS↗

A statistical analysis of the effects of urease pre-treatment on the measurement of the urinary metabolome by gas chromatography–mass spectrometry

Urease pre-treatment of urine has been utilized since the early 1960s to remove high levels of urea from samples prior to further processing and analysis by gas chromatography-mass spectrometry (GC-MS). Aside from the obvious depletion or elimination of urea, the effect, if any, of urease pre-treatment on the urinary metabolome has not been studied in detail. Here, we report the results of three separate but related experiments that were designed to assess possible indirect effects of urease pre-treatment on the urinary metabolome as measured by GC-MS. In total, 235 GC-MS analyses were performed and over 106 identified and 200 unidentified metabolites were quantified across the three experiments. The results showed that data from urease pre-treated samples 1) had the same or lower coefficients of variance among reproducibly detected metabolites, 2) more accurately reflected quantitative differences and the expected ratios among different urine volumes, and 3) increased the number of metabolite identifications. Altogether, we observed no negative consequences of urease pre-treatment. In contrast, urease pretreatment enhanced the ability to distinguish between volume-based and biological sample types compared to no treatment. Taken together, these results show that urease pretreatment of urine offers multiple beneficial effects that outweigh any artifacts that may be introduced to the data in urinary metabolomics analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancement of Magnetization and Tailoring of Blocking Temperatures of Nano-Ni–Zn Ferrite Powder Synthesized Using Microwave-assisted Combustion Method

Single-phase nano-Ni–Zn ferrite samples in the range of 6 to 75 nm were synthesized using microwave-assisted combustion method. Enhancement of saturation magnetization (M{sub s}) was observed in comparison with previously reported results. Minor variation of (M{sub s}) due to composition change can be explained on the basis of strengthening of A–B exchange interaction due to replacement of nonmagnetic Zn ions by Ni ions. Low coercivity (H{sub c}) and retentivity (M{sub r}) indicate low loss in the samples. SQUID analysis showed that the blocking temperature (T{sub B}) of the samples can be tailored in the present work.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Flux Maximization from a DD Neutron Generator

The University of Sharjah recently acquired a model DD-109.4M neutron generator from Adelphi Technology. The generator is moderated and has three neutron ports which are capable of providing fast and thermal neutrons. The neutron ports are plugged with polyethylene layers of different thickness in order to control the neutron flux at different regions in the port. Neutron Activation Analysis (NAA) is an important analysis technique to determine the amounts of isotopes in a sample at different concentrations. For many isotopes the ability to precisely determine their concentrations is enhanced by utilizing thermal neutrons in the activation process; where the capture cross section is greatest. It is thus important to subject the sample to the maximum thermal flux in order to minimize the time required to activate the sample and consequently extend the lifetime of the neutron generator. A detailed MCNP model of the neutron generator has been developed for the purpose of determining the moderator thickness required to maximize the thermal neutron flux in the neutron port. The maximization of the neutron flux must therefore take into account both the forward and backscattered neutrons reaching the sample. Also provided in this work is a mapping of the thermal flux at different moderator thicknesses in order to study the variation of the flux over the area of the sample. The developed model will be used as the basis for optimizing experiments and predicting their results. A study was performed to determine the moderator thickness needed to maximize the thermal neutron flux that can be obtained from a DD neutron generator. This has a significant role in the efficient utilization of the neutron generator. The maximum thermal neutron flux was found at approximately a 3.2 cm moderator thickness. The thermal neutron flux is resulting from both the directly moderated neutrons and the backscattered neutrons from the surrounding polyethylene. The results obtained in this work will be verified experimentally by irradiating samples at different moderator thickness and performing a neutron activation analysis for these samples. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Effect of Gd and Zr co-substitution on multiferroic properties of BiFeO{sub 3}

Single phase Bi{sub 1−x}Gd{sub x}Fe{sub 1−y}Zr{sub y}O{sub 3} (x=0.06;y=0, x= 0.10, y=0 and x=0.10,y= 0.03) nanoparticles were prepared to study the combined effect of Gd and Zr substitution on structural, magnetic and optical properties of BiFeO3. Rietveld refinement of X-ray diffraction patterns predicted that sample with x=0.06, y=0 was indexed to rhombohedral structure while samples with x=0.10, y=0 and x=0.10, y=0.03 were crystallized in multiphase (rhombohedral + orthorhombic). Magnetic properties were significantly enhanced with increasing concentration of Gd ions, however, magnetization reduced slightly with addition of 3% Zr ions in the system. Electron spin Resonance analysis indicated that breaking of spin cycloid is the main reason for enhancement of magnetization. Optical properties were investigated and direct band gap was found for all the samples.

36 MATERIALS SCIENCE↗

The Influence of Poly(3-Hexylthiophene) Regioregularity on Fullerene-Composite Solar Cell Performance

A comparison of three samples of poly(3-hexylthiophene) having regioregularities of 86, 90, and 96% is used to elucidate the effect of regioregularity on polymer-fullerene-composite solar cell performance. It is observed that polymer samples with lower regioregularity are capable of generating fullerene composites that exhibit superior thermal stability. The enhanced thermal stability of the composites is attributed to a lower driving force for polymer crystallization in the less regioregular polymer samples, which is supported with two-dimensional grazing incidence X-ray scattering and differential scanning calorimetry measurements. Furthermore, it is demonstrated that all three polymer samples are capable of generating solar cells with equivalent peak efficiencies of {approx}4% in blends with [6,6]-phenyl-C{sub 61}-butyric acid methyl ester. While it may be non-intuitive that polymers with lower regioregularity can exhibit higher efficiencies, it is observed that the charge-carrier mobility of the three polymers is on the same order of magnitude (10{sup -4} cm{sup 2} V{sup -1} s{sup 01}) when measured from the space-charge-limited current, suggesting that highly regioregular and crystalline polythiophenes are not required in order to effectively transport charges in polymer solar cells. Overall, these results suggest a design principle for semicrystalline conjugated polymers in fullerene-composite solar cells in which crystallization-driven phase separation can be dramatically suppressed via the introduction of a controlled amount of disorder into the polymer backbone.

14 SOLAR ENERGY↗

Effect of ultrasound treatment on the morpho-structural and luminescent characteristics of cerium doped yttrium silicate phosphors

Highlights: • Y{sub 2}SiO{sub 5}:Ce is prepared by gel combustion in ultrasound conditions (US). • Morpho-structural characteristics are revealed based on FTIR, SEM, XRD, BET. • Incorporation of Ce{sup 3+} in X1/X2 type centers depends on preparative conditions. • US treatment increases the luminescent performances up to 151%. - Abstract: Cerium activated yttrium silicate (Y{sub 2}SiO{sub 5}:Ce) phosphors were prepared by gel-combustion, using yttrium–cerium nitrate as oxidizer, aspartic acid as fuel and TEOS as source of silicon. Two modalities for samples preparation were approached namely: the classical gel-combustion and sonication gel-combustion. The ultrasound treatment during the gelling stage has a positive effect on the structural and luminescent characteristics of the final product. Therefore, a well crystallized single X2–Y{sub 2}SiO{sub 5} phase phosphor was obtained at 1200 °C. Based on FT-IR and XRD investigations, conversion of X1 to X2–Y{sub 2}SiO{sub 5} phases is observed as the firing temperature is varied (1100 °C, 1200 °C, 1300 °C 1400 °C). The ultrasound treatment leads to smaller particle size and enhances the luminescent performances up to 151% in comparison with samples prepared by classical way.

36 MATERIALS SCIENCE↗

Micro-CT scouting for transmission electron microscopy of human tissue specimens

Transmission electron microscopy (TEM) provides sub-nanometre-scale details in volumetric samples. Samples such as pathology tissue specimens are often stained with a metal element to enhance contrast, which makes them opaque to optical microscopes. As a result, it can be a lengthy procedure to find the region of interest inside a sample through sectioning. Here, we describe micro-CT scouting for TEM that allows noninvasive identification of regions of interest within a block sample to guide the sectioning step. In a tissue pathology study, a bench-top micro-CT scanner with 10 m resolution was used to determine the location of patches of the mucous membrane in osmium-stained human nasal scraping samples. Furthermore, once the regions of interest were located, the sample block was sectioned to expose that location, followed by ultra-thin sectioning and TEM to inspect the internal structure of the cilia of the membrane epithelial cells with nanometre resolution. This method substantially reduced the time and labour of the search process from typically 20 sections for light microscopy to three sections with no added sample preparation. Lay description Electron microscopy provides very high levels of detail in a small area, and thus the question of where to look in an opaque sample, such as a stained tissue specimen, needs to be answered by sectioning the sample in small steps and examining the sections under a light microscope, until the region of interest is found. The search process can be lengthy and labor intensive, especially for a study involving a large number of samples. Small areas of interest can be missed in the process if not enough regions are examined. We also describe a method to directly locate the region of interest within a whole sample using micro-CT imaging, bypassing the need of blindly sectioning. Micro-CT enables locating the region within 3D space; this information provides a guide for sectioning the sample to expose that precise location for high resolution electron microscopy imaging. In a human tissue specimen study, this method considerably reduced the time and labor of the search process.

60 APPLIED LIFE SCIENCES↗

Influence of Nb alloying on Nb recrystallization and the upper critical field of Nb 3 ⁢Sn

Nb 3 Sn conductors are important candidates for high-field magnets for particle accelerators, and they continue to be widely used for many laboratory and NMR magnets. However, the critical current density, J c , of present Nb 3 Sn conductors declines swiftly above 12-15 T. State-of-the-art Ta- and Ti-doped strands exhibit upper critical field, H c2 , values of ~ 24-26.5 T (4.2 K) and do not reach the FCC target J c , which serves as the present stretch target for Nb 3 Sn development. As recently demonstrated, to meet this goal requires enhanced vortex pinning but an independent and supplementary approach is to significantly enhance H c2 . In this study, we have arc-melted multiple Nb alloys with added Hf, Zr, Ta and Ti and drawn them successfully into monofilament wires to investigate the possibilities of H c2 enhancement through alloying. H c2 (T) was measured for all samples in fields up to 16 T and some up to 31 T. We have found that all alloys show good agreement with the standard Werthamer, Helfand, and Hohenberg (WHH) fitting procedure without the need to adjust the paramagnetic limitation parameter (α) and spin-orbit scattering parameter (λ so ). The evaluation of dH c2 /dT near T c , which is proportional to the electronic specific heat coefficient γ and the normal state resistivity ρn, allows a better understanding of the induced disorder introduced by alloying in the A15 phase. So far, we have observed that Hf alloying of pure Nb can enhance H c2 (0) by 3-4 T to ~28 T, while adding just 1 at. %Hf or Zr into a Nb4Ta base alloy can raise H c2 (0) to ~31 T. Very importantly we find that Hf and Zr raise the alloy recrystallization temperature above the usual A15 reaction temperature range of 650°C – 750°C, thus ensuring denser A15 phase nucleation in the Nb alloy grain boundaries, possibly leading to a more homogeneous A15 phase Sn content and refined A15 grain size. Furthermore, the potential for further advancements in Nb 3 Sn properties is explored in relation to the recrystallization of the Nb alloy and the factors controlling the upper critical field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TESTING TRIGGERED STAR FORMATION IN SIX H II REGIONS

We investigated six H II regions with infrared, bright rimmed bubble or cometary morphology, in search of quantitative evidence for triggered star formation, both collect and collapse and radiatively driven implosion (RDI). We identified and classified 458 young stellar objects (YSOs) in and around the H II regions. YSOs were determined by fitting a collection of radiative transfer model spectral energy distributions to infrared photometry for a large sample of point sources. We determined areas where there exist enhanced populations of relatively unevolved YSOs on the bright rims of these regions, suggesting that star formation has been triggered there. We further investigated the physical properties of the regions by using radio continuum emission as a proxy for ionizing flux powering the H II regions, and {sup 13}CO (1-0) observations to measure masses and gravitational stability of molecular clumps. We used an analytical model of collect and collapse triggered star formation, as well as a simulation of RDI, and thus we compare the observed properties of the molecular gas with those predicted in the triggering scenarios. Notably, those regions in our sample that show evidence of cometary, or 'blister', morphology are more likely to show evidence of triggering.

79 ASTRONOMY AND ASTROPHYSICS↗

The ALICE Electromagnetic Calorimeter

ALICE is the general purpose experiment at the LHC dedicated to the study of heavy-ion collisions. The electromagnetic calorimeter (EMCal) is a late addition to the ALICE suite of detectors with first modules installed in ALICE this year. The EMCal is designed to trigger on high energy gamma-rays and jets, and to enhance the capabilities of ALICE for these measurements. The EMCal is a Pb/scintillator sampling shish-kebab type calorimeter. The EMCal construction, readout, and performance in beam tests at the CERN SPS and PS are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a Welding Procedure for Making Critical Aluminum Welds on the LBNF Absorber Core Block

The LBNF Absorber consists of thirteen 6061-T6 aluminum core blocks. The core blocks are water cooled with de-ionized (DI) water which becomes radioactive during beam operations. The cooling water flows through gun-drilled channels in the core blocks. A weld quality optimization was performed to produce National Aeronautical Standard 1514 Class I quality welds on the aluminum core blocks. This was not successful in all cases. An existing Gas Tungsten Arc Welding Procedure Specification was fine tuned to minimize, in most cases, and eliminate detect-able tungsten inclusions in the welds. All the weld coupons, however passed welding inspection as per the piping code: ASME B31.3 Normal Fluid Service. Tungsten electrode diameter, type, and manufacturer were varied. Some of the samples were pre-heated and others were not. It was observed that larger diameter electrodes, 5/32 in., with pre-heated joints resulted in welds with the least number of tungsten inclusions. It is hypothesized that thinner electrodes breakdown easily and get lodged into the weld pool during the welding process. This breakdown is further enhanced by the large temperature differential between the un-preheated sample and the hot electrode.

43 PARTICLE ACCELERATORS↗

Optimization of a Welding Procedure for Making Critical Aluminum Welds on the LBNF Absorber Core Block

he LBNF Absorber consists of thirteen 6061-T6 aluminum core blocks. The core blocks are water cooled with de-ionized (DI) water which becomes radioactive during beam operations. The cooling water flows through gun-drilled channels in the core blocks. A weld quality optimization was performed to produce National Aeronautical Standard (NAS) 1514 Class I quality welds on the aluminum core blocks. This was not successful in all cases. An existing Gas Tungsten Arc Welding (GTAW) Welding Procedure Specification (WPS) was fine tuned to minimize, in most cases, and eliminate detectable tungsten inclusions in the welds. All the weld coupons however, passed welding inspection as per the piping code: ASME B31.3 Normal Fluid Service. Tungsten electrode diameter, type, and manufacturer were varied. Some of the samples were pre-heated and others were not. It was observed that larger diameter electrodes, 5/32 in., with pre-heated joints resulted in welds with the least number of tungsten inclusions. It is hypothesized that thinner electrodes breakdown easily and get lodged into the weld pool during the welding process. This breakdown is further enhanced by the large temperature differential between the un-preheated sample and the hot electrode.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗