Search NASA⌕ Search

SEARCH · Search NASA

Results for “FACTORIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Anomaly detection in collider physics via factorized observables

To maximize the discovery potential of high-energy colliders, experimental searches should be sensitive to unforeseen new physics scenarios. This goal has motivated the use of machine learning for unsupervised anomaly detection. In this paper, we introduce a new anomaly detection strategy called : factorized observables for regressing conditional expectations. Our approach is based on the inductive bias of factorization, which is the idea that the physics governing different energy scales can be treated as approximately independent. Assuming factorization holds separately for signal and background processes, the appearance of nontrivial correlations between low- and high-energy observables is a robust indicator of new physics. Under the most restrictive form of factorization, a machine-learned model trained to identify such correlations will in fact converge to the optimal new physics classifier. We test on a benchmark anomaly detection task for the Large Hadron Collider involving collimated sprays of particles called jets. By teasing out correlations between the kinematics and substructure of jets, our method can reliably extract percent-level signal fractions. This strategy for uncovering new physics adds to the growing toolbox of anomaly detection methods for collider physics with a complementary set of assumptions. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Breakdown of collinear factorization in the exclusive photoproduction of a π 0 γ pair with large invariant mass

We study the exclusive photoproduction of a π 0 γ pair with large invariant mass M γ π 2 , which is sensitive to the exchange of either two quarks or two gluons in the t channel. In this paper, we show that the process involving two-gluon exchanges does factorize in the Bjorken limit at the leading twist. This can be explicitly demonstrated by the fact that there exist diagrams, which contribute at the leading twist, for which are , due to the pinching of the contour integration of the plus and minus component of the Glauber gluon momentum. For the same reason, π 0 -nucleon scattering to two photons also suffers from the same issue. On the other hand, we stress that there are no issues with respect to collinear factorization for the quark channels. By considering an analysis of all potential reduced diagrams of leading pinch-singular surfaces, we argue that the quark channel is safe from Glauber pinches, and therefore, a collinear factorization in that case follows through without any problems. This means that processes where gluon exchanges are forbidden, such as the exclusive photoproduction of π ± γ and ρ 0 , ± γ , are unaffected by the factorization breaking effects we point out in this paper. Published by the American Physical Society 2025

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Post-Newtonian factorized multipolar waveforms for spinning, nonprecessing black-hole binaries

We generalize the factorized resummation of multipolar waveforms introduced by Damour, Iyer, and Nagar to spinning black holes. For a nonspinning test particle spiraling a Kerr black hole in the equatorial plane, we find that factorized multipolar amplitudes which replace the residual relativistic amplitude f{sub lm} with its lth root, {rho}{sub lm}=f{sub lm}{sup 1/l}, agree quite well with the numerical amplitudes up to the Kerr-spin value q{<=}0.95 for orbital velocities v{<=}0.4. The numerical amplitudes are computed solving the Teukolsky equation with a spectral code. The agreement for prograde orbits and large spin values of the Kerr black-hole can be further improved at high velocities by properly factoring out the lower-order post-Newtonian contributions in {rho}{sub lm}. The resummation procedure results in a better and systematic agreement between numerical and analytical amplitudes (and energy fluxes) than standard Taylor-expanded post-Newtonian approximants. This is particularly true for higher-order modes, such as (2,1), (3,3), (3,2), and (4,4), for which less spin post-Newtonian terms are known. We also extend the factorized resummation of multipolar amplitudes to generic mass-ratio, nonprecessing, spinning black holes. Lastly, in our study we employ new, recently computed, higher-order post-Newtonian terms in several subdominant modes and compute explicit expressions for the half and one-and-half post-Newtonian contributions to the odd-parity (current) and even-parity (odd) multipoles, respectively. Those results can be used to build more accurate templates for ground-based and space-based gravitational-wave detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Up, down, and strange nucleon axial form factors from lattice QCD

Here, we report a calculation of the nucleon axial form factors $G_A^q(Q^2)$ and $G_P^q(Q^2)$ for all three light quark flavors $q\in\{u,d,s\}$ in the range $0\leq Q^2\lesssim 1.2\text{ GeV}^2$ using lattice QCD. Our work was done using a single ensemble with pion mass 317 MeV and made use of the hierarchical probing technique to efficiently evaluate the required disconnected loops. We perform nonperturbative renormalization of the axial current, including a nonperturbative treatment of the mixing between light and strange currents due to the singlet-nonsinglet difference caused by the axial anomaly. The form factor shapes are fit using the model-independent $z$ expansion. From $G_A^q(Q^2)$, we determine the quark contributions to the nucleon spin and axial radii. By extrapolating the isovector $G_P^{u-d}(Q^2)$, we obtain the induced pseudoscalar coupling relevant for ordinary muon capture and the pion-nucleon coupling constant. We also found that the disconnected contributions to $G_P$ form factors are large, and give an interpretation based on the dominant influence of the pseudoscalar poles in these form factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Conduction and Valence Bands g -Factors in a Transition Metal Dichalcogenide Monolayer

The electron valley and spin degree of freedom in monolayer transition-metal dichalcogenides can be manipulated in optical and transport measurements performed in magnetic fields. The key parameter for determining the Zeeman splitting, namely, the separate contribution of the electron and hole g factor, is inaccessible in most measurements. Here we present an original method that gives access to the respective contribution of the conduction and valence band to the measured Zeeman splitting. It exploits the optical selection rules of exciton complexes, in particular the ones involving intervalley phonons, avoiding strong renormalization effects that compromise single particle g -factor determination in transport experiments. These studies yield a direct determination of single band g factors. We measure g c1 = 0.86 ± 0.1, g c2 = 3.84 ± 0.1 for the bottom (top) conduction bands and g v = 6.1 ± 0.1 for the valence band of monolayer WSe 2 . These measurements are helpful for quantitative interpretation of optical and transport measurements performed in magnetic fields. In addition, the measured g factors are valuable input parameters for optimizing band structure calculations of these 2D materials.

36 MATERIALS SCIENCE↗

Nucleation of stoichiometric compounds from liquid: Role of the kinetic factor

The nucleation rate depends on the free-energy barrier and the kinetic factor. While the role of the free energy barrier is a text-book subject, the importance of the kinetic factor is frequently underestimated. Here in this study, we applied the mean first-passage time method, to obtain the free-energy landscape and kinetic factor directly from the molecular dynamics (MD) simulations of the nucleation of the face-centered cubic (fcc) phase in the pure Ni and the B2 phases in the Ni 50 Al 50 and Cu 50 Zr 50 alloys. The obtained data show that while the free-energy barrier for nucleation is higher in pure Ni the nucleation rate is considerably lower in the Ni 50 Al 50 alloy. This result can be explained by the slow attachment kinetics in the N i 50 A l 50 alloy, which was related to the ordered nature of the B2 phase. Even smaller fraction of the antisite defects in the C u 50 Z r 50 alloy leads to such a slow attachment kinetics that the nucleation is never observed for this alloy in the course of the MD simulation. Finally, this is consistent with the experimental facts that the Cu 50 Zr 50 alloy is a good glass forming alloy and the Ni 50 Al 50 alloy is not. Thus the present study demonstrates that the atom attachment rate can be the critical factor that controls the nucleation process under certain conditions.

36 MATERIALS SCIENCE↗

Factors correlating with significant differences between X-ray structures of myoglobin

Conformational differences between myoglobin structures are studied. Most structural differences in whale myoglobin beyond the uncertainty threshold can be correlated with a few specific structural factors. There are always exceptions and a search for additional factors is needed. The results might have serious implications for biological insights from conformational differences. Validation of general ideas about the origins of conformational differences in proteins is critical in order to arrive at meaningful functional insights. Here, principal component analysis (PCA) and distance difference matrices are used to validate some such ideas about the conformational differences between 291 myoglobin structures from sperm whale, horse and pig. Almost all of the horse and pig structures form compact PCA clusters with only minor coordinate differences and outliers that are easily explained. The 222 whale structures form a few dense clusters with multiple outliers. A few whale outliers with a prominent distortion of the GH loop are very similar to the cluster of horse structures, which all have a similar GH-loop distortion apparently owing to intermolecular crystal lattice hydrogen bonds to the GH loop from residues near the distal histidine His64. The variations of the GH-loop coordinates in the whale structures are likely to be owing to the observed alternative intermolecular crystal lattice bond, with the change to the GH loop distorting bonds correlated with the binding of specific ‘unusual’ ligands. Such an alternative intermolecular bond is not observed in horse myoglobins, obliterating any correlation with the ligands. Intermolecular bonds do not usually cause significant coordinate differences and cannot be validated as their universal cause. Most of the native-like whale myoglobin structure outliers can be correlated with a few specific factors. However, these factors do not always lead to coordinate differences beyond the previously determined uncertainty thresholds. The binding of unusual ligands by myoglobin, leading to crystal-induced distortions, suggests that some of the conformational differences between the apo and holo structures might not be ‘functionally important’ but rather artifacts caused by the binding of ‘unusual’ substrate analogs. The causes of P6 symmetry in myoglobin crystals and the relationship between crystal and solution structures are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Beyond integration: modeling every pixel to obtain better structure factors from stills

Most crystallographic data processing methods use pixel integration. In serial femtosecond crystallography (SFX), the intricate interaction between the reciprocal lattice point and the Ewald sphere is integrated out by averaging symmetrically equivalent observations recorded across a large number (10 4 -10 6 ) of exposures. Although sufficient for generating biological insights, this approach converges slowly, and using it to accurately measure anomalous differences has proved difficult. This report presents a novel approach for increasing the accuracy of structure factors obtained from SFX data. A physical model describing all observed pixels is defined to a degree of complexity such that it can decouple the various contributions to the pixel intensities. Model dependencies include lattice orientation, unit-cell dimensions, mosaic structure, incident photon spectra and structure factor amplitudes. Maximum likelihood estimation is used to optimize all model parameters. The application of prior knowledge that structure factor amplitudes are positive quantities is included in the form of a reparameterization. The method is tested using a synthesized SFX dataset of ytterbium(III) lysozyme, where each X-ray laser pulse energy is centered at 9034 eV. This energy is 100 eV above the Yb 3+ L -III absorption edge, so the anomalous difference signal is stable at 10 electrons despite the inherent energy jitter of each femtosecond X-ray laser pulse. This work demonstrates that this approach allows the determination of anomalous structure factors with very high accuracy while requiring an order-of-magnitude fewer shots than conventional integration-based methods would require to achieve similar results.

59 BASIC BIOLOGICAL SCIENCES↗

Power Factor revisited

Power factor is a term whose value can be found by dividing the power in a load to the product of the voltage and the current. It has been used as a rule of thumb to estimate the cost of the losses incurred in delivering reactive power. But it has been extremely troublesome. The same load might be penalized by some definitions, and might not by others. That is still the situation today. There have been two efforts at solution. In 1919 a committee of experts was formed to solve the problem of its definition. The effort did not succeed at producing a definition; two alternatives were recommended in the committee’s final report, but both were adopted. In 2010, IEEE issued Standard 1459 to give definitions. In this standard, definitions of power factor appear under no less than seven different headings. The problem demands solution. The matter is of considerable economic importance to power producers, consumers, and instrument makers. This paper examines the history of the topic, and explores reasons for the difficulty of definition in terms of measurement theory. It is shown that power factor is not suited to purpose. In fact, no definition can exist that will define power factor usefully for its intended economic purpose. Two alternatives are proposed.

power factror, definitions, measurement theory, IE↗

A Communication-Avoiding 3D LU Factorization Algorithm for Sparse Matrices

We propose a new algorithm to improve the strong scalability of right-looking sparse LU factorization on distributed memory systems. Our 3D sparse LU algorithm uses a three-dimensional MPI process grid, aggressively exploits elimination tree parallelism and trades off increased memory for reduced per-process communication. We also analyze the asymptotic improvements for planar graphs (e.g., from 2D grid or mesh domains) and certain non-planar graphs (specifically for 3D grids and meshes). For planar graphs with n vertices, our algorithm reduces communication volume asymptotically in n by a factor of O{log n} and latency by a factor of O{log n}. For non-planar cases, our algorithm can reduce the per-process communication volume by 3× and latency by O{n^1/3} times. In all cases, the memory needed to achieve these gains is a constant factor. We implemented our algorithm by extending the 2D data structure used in superLU. Our new 3D code achieves speedups up to 27× for planar graphs and up to 3.3× for non-planar graphs over the baseline 2D superLU when run on 24,000 cores of a Cray XC30.

Sao, Piyush↗

Implementation and Tuning of Batched Cholesky Factorization and Solve for NVIDIA GPUs

Many problems in engineering and scientific computing require the solution of a large number of small systems of linear equations. Due to their high processing power, Graphics Processing Units became an attractive target for this class of problems, and routines based on the LU and the QR factorization have been provided by NVIDIA in the cuBLAS library. This work addresses the situation where the systems of equations are symmetric positive definite. The paper describes the implementation and tuning of the kernels for the Cholesky factorization and the forward and backward substitution. Targeted workloads involve the solution of thousands of linear systems of the same size, where the focus is on matrix dimensions from 5 by 5 to 100 by 100. Due to the lack of a cuBLAS Cholesky factorization, execution rates of cuBLAS LU and cuBLAS QR are used for comparison against the proposed Cholesky factorization in this work. Execution rates of forward and backward substitution routines are compared to equivalent cuBLAS routines. Comparisons against optimized multicore implementations are also presented. Superior performance is reached in all cases.

Computer Science↗

COM1 , a factor of alternative non‐homologous end joining, lagging behind the classic non‐homologous end joining pathway in rice somatic cells

SUMMARY The role of rice ( Oryza sativa ) COM1 in meiotic homologous recombination (HR) is well understood, but its part in somatic double‐stranded break (DSB) repair remains unclear. Here, we show that for rice plants COM1 conferred tolerance against DNA damage caused by the chemicals bleomycin and mitomycin C, while the COM1 mutation did not compromise HR efficiencies and HR factor (RAD51 and RAD51 paralogues) localization to irradiation‐induced DSBs. Similar retarded growth at the post‐germination stage was observed in the com1‐2 mre11 double mutant and the mre11 single mutant, while combined mutations in COM1 with the HR pathway gene ( RAD51C ) or classic non‐homologous end joining (NHEJ) pathway genes ( KU70 , KU80 , and LIG4 ) caused more phenotypic defects. In response to γ‐irradiation, COM1 was loaded normally onto DSBs in the ku70 mutant, but could not be properly loaded in the MRE11 RNAi plant and in the wortmannin‐treated wild‐type plant. Under non‐irradiated conditions, more DSB sites were occupied by factors (MRE11, COM1, and LIG4) than RAD51 paralogues (RAD51B, RAD51C, and XRCC3) in the nucleus of wild‐type; protein loading of COM1 and XRCC3 was increased in the ku70 mutant. Therefore, quite differently to its role for HR in meiocytes, rice COM1 specifically acts in an alternative NHEJ pathway in somatic cells, based on the Mre11–Rad50–Nbs1 (MRN) complex and facilitated by PI3K‐like kinases. NHEJ factors, not HR factors, preferentially load onto endogenous DSBs, with KU70 restricting DSB localization of COM1 and XRCC3 in plant somatic cells.

Xu, Zhan↗

A Discussion of Strength Reduction Factor Development for Thermal Aging Effect on Nuclear Structural Alloys

In consideration of structural alloy property deterioration during long-term exposure to elevated temperatures, the yield and ultimate tensile strength reduction factors are provided in the Boiler and Pressure Vessel Code Section III for nuclear reactor component design and operation analysis. Because the Gen IV reactor requirement of 40 ~ 60 years of service life makes it difficult to acquire such long exposure test data for developing the reduction factors, they must be derived from test data with relatively short exposure by predictive methods considered to be reasonably reliable. A novel approach with a physically-based model has recently been proposed for application to development of reduction factors for 9Cr-1Mo-V. In the model, contributors to the tensile strength are first identified and related to definite microstructural features of the alloy, then some physically-based methods are employed to simulate the microstructural evolution, and finally the model is assembled with test-data-calibrated parameters to generate the yield and ultimate tensile strength reduction factors covering elevated temperature exposure for up to 57 years. The approach is undoubtedly a trailblazing development that will, if proven reliable, lead to a paradigm shift in predicting thermal aging behavior of many other alloys. Its debut application to Section III, however, concerns nuclear safety and naturally warrants objective, impartial, and thorough technical scrutiny. In the present paper, the novel and conventional approaches are discussed. Necessary improvements to the novel approach are recommended for its application to nuclear structural component design and analysis, and for its potential expanded use to other alloys.

Ren, Weiju↗

Factor analysis in automated face detection: gender, occlusion, eyewear, brightness, contrast, and focus measure

Computer-based facial recognition algorithms exploit the unique characteristics of faces in images. However, in non-cooperative situations these unique characteristics are often disturbed. In this study, we examine the effect of six different factors on face detection in an unconstrained imaging environment: image brightness, image contrast, focus measure, eyewear, gender, and occlusion. The aim of this study is twofold: first, to quantify detection rates of conventional Haar cascade algorithms across these six factors; and second, to propose methods for automatically labeling datasets whose size prohibits manual labeling. First, we manually classify a uniquely challenging dataset comprising 9,688 images of passengers in vehicles acquired from a roadside camera system. Next, we quantify how each of the aforementioned factors affect face detection on this dataset. Of the six factors studied, occlusion had the most significant impact, resulting in a 54% decrease in detection rate between unoccluded and severely occluded faces in our unique dataset. Finally, we provide a methodology for data analytics of large datasets where manual labeling of the whole dataset is not possible.

Jafek, Benjamin↗

Measurement of relative output factors for the 8 and 4 mm collimators of Leksell Gamma Knife Perfexion by film dosimetry

Three types of films, Kodak EDR2, Gafchromic EBT, and Gafchromic MD-V2-55, were used to measure relative output factors of 4 and 8 mm collimators of the Leksell Gamma Knife Perfexion. The optical density to dose calibration curve for each of the film types was obtained by exposing the films to a range of known doses. Ten data points were acquired for each of the calibration curves in the dose ranges from 0 to 4 Gy, 0 to 8 Gy, and 0 to 80 Gy for Kodak EDR2, Gafchromic EBT, and Gafchromic MD-V2-55 films, respectively. For the measurement of relative output factors, five films of each film type were exposed to a known dose. All films were scanned using EPSON EXPRESSION 10000 XL scanner with 200 dpi resolution in 16 bit gray scale for EDR2 film and 48 bit color scale for Gafchromic films. The scanned images were imported in the red channel for both Gafchromic films. The background corrections from an unexposed film were applied to all films. The output factors obtained from film measurements were in a close agreement both with the Monte Carlo calculated values of 0.924 and 0.805 for 8 and 4 mm collimators, respectively. These values are provided by the vendor and used as default values in the vendor's treatment planning system. The largest differences were noted for the Kodak EDR 2 films (-2.1% and -4.5% for 8 and 4 mm collimators, respectively). The best agreement observed was for EBT Gafchromic film (-0.8% and +0.6% differences for 8 and 4 mm collimators, respectively). Based on the present values, no changes in the default relative output factor values were made in the treatment planning system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Replacement correction factors for cylindrical ion chambers in electron beams

Purpose: In the TG-21 dosimetry protocol, for cylindrical chambers in electron beams the replacement correction factor P{sub repl} (or the product p{sub dis}p{sub cav} in the IAEA's notation), was conceptually separated into two components: the gradient correction (P{sub gr}) accounting for the effective point of measurement and the fluence correction (P{sub fl}) dealing with the change in the electron fluence spectrum. At the depth of maximum dose (d{sub max}), P{sub gr} is taken as 1. There are experimental data available at d{sub max} for the values of P{sub fl} (or P{sub repl}). In the TG-51 dosimetry protocol, the calibration is at the reference depth d{sub ref}=0.6R{sub 50}-0.1 (cm) where P{sub gr} is required for cylindrical chambers and P{sub fl} is unknown and so the measured values at d{sub max} are used with the corresponding mean electron energy at d{sub ref}. Monte Carlo simulations are employed in this study to investigate the replacement correction factors for cylindrical chambers in electron beams. Methods: Using previously established Monte Carlo calculation methods, the values of P{sub repl} and P{sub fl} are calculated with high statistical precision (<0.1%) for cylindrical cavities of a variety of diameters and lengths in a water phantom irradiated by various electron beams. The values of P{sub gr} as defined in the TG-51 dosimetry protocol are also calculated. Results: The calculated values of the fluence correction factors P{sub fl} are in good agreement with the measured values when the wall correction factors are taken into account for the plane-parallel chambers used in the measurements. An empirical formula for P{sub fl} for cylindrical chambers at d{sub ref} in electron beams is derived as a function of the chamber radius and the beam quality specifier R{sub 50}. Conclusions: The mean electron energy at depth is a good beam quality specifier for P{sub fl}. Thus TG-51's adoption of P{sub fl} at d{sub max} with the same mean electron energy for use at d{sub ref} is proven to be accurate. The values of P{sub gr} for a Farmer-type chamber as defined in the TG-51 dosimetry protocol may be wrong by 0.3% for high-energy electron beams and by more than 1% for low-energy electron beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector

Purpose: This work presents the experimental extraction of the overall perturbation factor P{sub Q} in megavoltage electron beams for NACP-02 and Roos parallel-plate ionization chambers using a plastic scintillation detector (PSD). Methods: The authors used a single scanning PSD mounted on a high-precision scanning tank to measure depth-dose curves in 6, 12, and 18 MeV clinical electron beams. The authors also measured depth-dose curves using the NACP-02 and PTW Roos chambers. Results: The authors found that the perturbation factors for the NACP-02 and Roos chambers increased substantially with depth, especially for low-energy electron beams. The experimental results were in good agreement with the results of Monte Carlo simulations reported by other investigators. The authors also found that using an effective point of measurement (EPOM) placed inside the air cavity reduced the variation of perturbation factors with depth and that the optimal EPOM appears to be energy dependent. Conclusions: A PSD can be used to experimentally extract perturbation factors for ionization chambers. The dosimetry protocol recommendations indicating that the point of measurement be placed on the inside face of the front window appear to be incorrect for parallel-plate chambers and result in errors in the R{sub 50} of approximately 0.4 mm at 6 MeV, 1.0 mm at 12 MeV, and 1.2 mm at 18 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo calculations of k{sub Q}, the beam quality conversion factor

Purpose: To use EGSnrc Monte Carlo simulations to directly calculate beam quality conversion factors, k{sub Q}, for 32 cylindrical ionization chambers over a range of beam qualities and to quantify the effect of systematic uncertainties on Monte Carlo calculations of k{sub Q}. These factors are required to use the TG-51 or TRS-398 clinical dosimetry protocols for calibrating external radiotherapy beams. Methods: Ionization chambers are modeled either from blueprints or manufacturers' user's manuals. The dose-to-air in the chamber is calculated using the EGSnrc user-code egs{sub c}hamber using 11 different tabulated clinical photon spectra for the incident beams. The dose to a small volume of water is also calculated in the absence of the chamber at the midpoint of the chamber on its central axis. Using a simple equation, k{sub Q} is calculated from these quantities under the assumption that W/e is constant with energy and compared to TG-51 protocol and measured values. Results: Polynomial fits to the Monte Carlo calculated k{sub Q} factors as a function of beam quality expressed as %dd(10){sub x} and TPR{sub 10}{sup 20} are given for each ionization chamber. Differences are explained between Monte Carlo calculated values and values from the TG-51 protocol or calculated using the computer program used for TG-51 calculations. Systematic uncertainties in calculated k{sub Q} values are analyzed and amount to a maximum of one standard deviation uncertainty of 0.99% if one assumes that photon cross-section uncertainties are uncorrelated and 0.63% if they are assumed correlated. The largest components of the uncertainty are the constancy of W/e and the uncertainty in the cross-section for photons in water. Conclusions: It is now possible to calculate k{sub Q} directly using Monte Carlo simulations. Monte Carlo calculations for most ionization chambers give results which are comparable to TG-51 values. Discrepancies can be explained using individual Monte Carlo calculations of various correction factors which are more accurate than previously used values. For small ionization chambers with central electrodes composed of high-Z materials, the effect of the central electrode is much larger than that for the aluminum electrodes in Farmer chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗