Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Storage Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

14 SOLAR ENERGY↗

Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An integrated equipment for massive segmentation and packaging of control Rod Guide Tubes - 15161

Over time, some utilities have decided to undergo safety upgrades that include replacement of some ageing components like control rod guide tubes (GT's). GT's are safety related components because they control the path of the control rods into and out of the core. These components are usually stored underwater in interim storage pools to decay their radioactivity. When the interim storage facility reaches saturation, treatment and final disposal of the retired Guide Tubes needs to be performed. Based on more than 30 years of experience and lessons learned in the development of segmentation and packaging technologies for nuclear components, Westinghouse has designed, commissioned and will operate a dedicated system for cutting and packaging retired GT's from 900 MW plants, currently stored in a EDF maintenance facility located in the south of France. The first main technical challenge was the waste volume optimization. Two separate waste streams had to be considered for coping with the highly irradiated portion of the GT's (lower part) and the very low level waste sections (upper part). The segmentation plan has been designed to minimize the waste volume of the highly irradiated waste and therefore develop a process which could be adapted to the container size specified by EDF. Metallic baskets have been designed to optimize the packaging and storage density in the containers. All cutting techniques previously used by Westinghouse in similar applications were assessed and underwater mechanical cutting with a band saw was selected as the preferred method. A turning stand positions the GT in front of the band saw. When the cut is completed, the remnant GT is inserted into the next turning stand for the next cut. Each cell of the turning stand positions the GT at the pre-defined cutting height. An integrated water filtration system is used to ensure good visibility during the cutting operations and to minimize water volume and limit the final liquid effluents. The whole process of GT insertion, cutting, packaging and waste conditioning is carried out in a hot cell and controlled remotely. The operator can therefore follow the packaging plan accurately and safely by using a four axis pick and place unit, while keeping personal radiation exposure low. This innovative process allows cutting and packaging large quantities of GT's in a safe and efficient manner. The pilot project covers the segmentation of 93 GT's but it can be further used for cutting larger quantities of retired GT's resulting from the upcoming GT replacement campaigns. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NRC Technical Research Program to Evaluate Extended Storage and Transportation of Spent Nuclear Fuel - 12547

Any new direction proposed for the back-end of spent nuclear fuel (SNF) cycle will require storage of SNF beyond the current licensing periods. The Nuclear Regulatory Commission (NRC) has established a technical research program to determine if any changes in the 10 CFR part 71, and 72 requirements, and associated guidance might be necessary to regulate the safety of anticipated extended storage, and subsequent transport of SNF. This three part program of: 1) analysis of knowledge gaps in the potential degradation of materials, 2) short-term research and modeling, and 3) long-term demonstration of systems, will allow the NRC to make informed regulatory changes, and determine when and if additional monitoring and inspection of the systems is necessary. The NRC has started a research program to obtain data necessary to determine if the current regulatory guidance is sufficient if interim dry storage has to be extended beyond the currently approved licensing periods. The three-phased approach consists of: - the identification and prioritization of potential degradation of the components related to the safe operation of a dry cask storage system, - short-term research to determine if the initial analysis was correct, and - a long-term prototypic demonstration project to confirm the models and results obtained in the short-term research. The gap analysis has identified issues with the SCC of the stainless steel canisters, and SNF behavior. Issues impacting the SNF and canister internal performance such as high and low temperature distributions, and drying have also been identified. Research to evaluate these issues is underway. Evaluations have been conducted to determine the relative values that various types of long-term demonstration projects might provide. These projects or follow-on work is expected to continue over the next five years. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Facile synthesis of mesophase pitch/exfoliated graphite nanoplatelets nanocomposite and its application as anode materials for lithium-ion batteries

Mesophase pitch (MP)/exfoliated graphite nanoplatelets (GNPs) nanocomposite has been prepared by an efficient method with an initiation of graphite intercalation compounds (GIC). X-ray diffraction, optical microscopy, high-resolution transmission electron microscopy and scanning electron microscopy analysis techniques are used to characterize the samples. It is observed that GIC has exfoliated completely into GNPs during the formation of MP/GNPs nanocomposite and the GNPs are distributed uniformly in MP matrix, which represent a conductive path for a movement of electrons throughout the composites. Electrochemical tests demonstrate that the carbonized MP/GNPs nanocomposite displays higher capacity and better cycle performance in comparison with the pure carbonized MP. It is concluded that such a large improvement of electrochemical performance within the nanocomposite may in general be related to the enhanced electronic conductivity, which is achieved by good dispersion of GNPs within MP matrix and formation of a 3D network of GNPs. - Graphical abstract: Uniform mesophase pitch/exfoliated graphite nanoplatelets nanocomposite has been efficiently fabricated with an initiation of graphite intercalation compounds. The as-prepared composite electrode exhibited high electrochemical performance for Li-ion batteries.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Nodal capacity expansion planning with flexible large-scale load siting

We propose explicitly incorporating large-scale load siting into a stochastic nodal power system capacity expansion planning model that concurrently co-optimizes generation, transmission, and storage expansion. The potential operational flexibility of some of these large loads is also taken into account by considering them as consisting of a set of tranches with different reliability requirements, which are modeled as a constraint on expected served energy across operational scenarios. We implement our model as a two-stage stochastic mixed-integer optimization problem with cross-scenario expectation constraints. To overcome the challenge of scalability, we build upon existing work to implement this model on a high performance computing platform and exploit scenario parallelization using an augmented Progressive Hedging Algorithm. The algorithm is implemented using the bounding features of mpisppy, which have shown to provide satisfactory provable optimality gaps despite the absence of theoretical guarantees of convergence. We test our approach and assess the value of this proactive planning framework on total system cost and reliability metrics using realistic testcases geographically assigned to San Diego and South Carolina, with datacenter and direct air capture facilities as large loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct Measurement of Ammonia Storage on Passive SCR Systems for Lean Gasoline NOx Reduction Using Radio Frequency Sensing

Lean gasoline engine operation provides clear efficiency benefits relative to conventional stoichiometric combustion approaches. One of the key hurdles to the widespread, practical implementation of lean gasoline combustion remains the challenge of lean NOx control. One of the potential approaches for controlling NOx emission from lean gasoline engines is the so-called passive selective catalytic reduction (SCR) system. In such systems, periods of rich operation generate ammonia over a three-way catalyst (TWC), which is then adsorbed on the downstream SCR and consumed during lean operation. Brief periods of rich operation must occur in response to the depletion of stored ammonia on the SCR, which requires reliable measurements of the SCR ammonia inventory. Presently, lean exhaust system controls rely on a variety of gas sensors mounted up- and downstream of the catalysts, and which only provide an indirect inference of the operation state.In this study, a radio frequency (RF) sensor was used to provide a direction measurement of the amount of ammonia adsorbed on the SCR in real-time. The RF sensor was calibrated and deployed on a BMW N43B20 4-cylinder lean gasoline engine equipped with a passive SCR system. Brief periods of rich operation performed at lambda values between 0.98 and 0.99 generated the ammonia, subsequently stored on the SCR for consumption during periods of lean operation. The experiments compared real-time measurements of SCR ammonia inventory from the RF sensor with estimates of ammonia coverage derived from exhaust gas composition measurements upstream and downstream of the catalyst. The results showed a high degree of correlation between the RF measurements and SCR ammonia storage inventory, and demonstrated NOx conversion efficiencies above 98%, confirming the feasibility of the concept. Relative to stoichiometric operation, lean-gasoline operation resulted in fuel efficiency gains of up to 10%, which may be further improved through direct feedback control from the RF sensor to optimize lean–rich cycling based on actual, measured SCR ammonia levels.

Ragaller, Paul↗

Structure-Property Relationships of Hydrogel-Salt Composites for Extreme Sorption Performance

Hydrogel-salt composites have emerged as a promising low-cost material for a wide range of sorption applications including thermal energy storage, atmospheric water harvesting, and dehumidification. Despite significant efforts devoted to the synthesis of novel hydrogels and their implementation in sorption devices, very little is known about the fundamental connection between the hydrogel structure and composition with their material-level properties. This knowledge, however, is critical to enable the rational design of high-performance hydrogels targeted at the various applications. In this work, we elucidate via experiments and modeling the link between the hydrogel structure, including its salt content and polymer nanostructure, and its sorption properties. Using lithium chloride-embedded polyacrylamide hydrogels as model systems, we demonstrate that the hydrogel uptake and its kinetics are dominated by the content and properties of the salt. In fact, the polymer nanostructure has no a minor effect in its sorption performance. Based on our experimental insights, we develop a model for the simultaneous diffusion of water and salts in hydrogels, which helps to explain the observed relationship between hydrogel structure and its sorption properties. Furthermore, we leverage these insights to synthesize hydrogels with record-high water vapor uptakes of 1.79 g/g, 2.58 g/g, 3.86 g/g, and 8.51 g/g at 30%, 50%, 70%, and 90% relative humidity, respectively, owing to the use of large amounts of highly hygroscopic salts. By demonstrating the structure-property relationships, this work enables the rational design of salt-embedded hydrogels for low-cost and high-performance thermal energy storage, atmospheric freshwater production, and space conditioning.

Díaz-Marín, Carlos D↗

Aqueous vs. nonaqueous Zn-ion batteries: consequences of the desolvation penalty at the interface

Zinc ion batteries using metallic zinc as the negative electrode have gained considerable interest for electrochemical energy storage, whose development is crucial for the adoption of renewable energy technologies, as zinc has a very high volumetric capacity (5845 mA h cm -3 ), is inexpensive and compatible with aqueous electrolytes. However, the divalent charge of zinc ions, which restricts the choice of host material due to hindered solid-state diffusion, can also pose a problem for interfacial charge transfer. We report our findings on reversible intercalation of up to two Zn 2+ ions in layered V 3 O 7 ·H 2 O. This material exhibits very high capacity and power (375 mA h g -1 at a 1C rate, and 275 mA h g -1 at an 8C rate) in an aqueous electrolyte compared to a very low capacity and slow rate capabilities in a nonaqueous medium. Operando XRD studies, together with impedance analysis, reveal solid solution behavior associated with Zn 2+ -ion diffusion within a water monolayer in the interlayer gap in both systems, but very sluggish interfacial charge transfer in the nonaqueous electrolyte. This points to desolvation at the interface as a major factor in dictating the kinetics. Temperature dependent impedance studies show high activation energies associated with the nonaqueous charge transfer process, identifying the origin of poor electrochemical performance.

25 ENERGY STORAGE↗

Revealing the working mechanism of a multi-functional block copolymer binder for lithium-sulfur batteries

The lithium-sulfur (Li-S) battery is one of the most promising substitutes for current energy storage systems because of its low cost, high theoretical capacity, and high energy density. However, the high solubility of intermediate products (i.e., lithium polysulfides) and the resultant shuttle effect lead to rapidly fading capacity and a low coulombic efficiency, which hinder the practical application of Li-S batteries. In this study, block copolymers are constructed with both an ethylene oxide unit and a styrene unit and then used as binders for Li-S batteries. Electrochemical performance improvements are attributed to the synergistic effects contributed by the different units of the block copolymer. Here, the ethylene oxide unit traps polysulfide, which bonds strongly with the intermediate lithium polysulfide, and enhances the transport of lithium ions to reach high capacity. Meanwhile, the styrene unit maintains cathode integrity by improving the mechanical properties and elasticity of the constructed block copolymer to accommodate the large volume changes. By enabling multiple functions via different units in the polymer chain, high sulfur utilization is achieved, polysulfide diffusion is confined, and the shuttle effect is suppressed during the cycle life of Li-S batteries, as revealed by operando ultraviolet–visible spectroscopy and S K-edge X-ray absorption spectroscopy.

25 ENERGY STORAGE↗

Digital Twin Development of FASTR

This work package is focused on creating a digital twin (DT) of the Facility to Alleviate Salt Technology Risks (FASTR) experiment. FASTR is a high-profile facility tasked with maturing molten salt applications such as liquid salt energy storage, concentrated solar power facilities, and molten salt cooling systems supporting other advanced reactor technologies, all of which may be incorporated as components within the Integrated Energy Systems (IES) program. As part of creating a digital twin (DT), verification and validation (V&V) has been performed for the physics-based model, and gaps have been identified. Additionally, a preliminary integration of the FASTR model has been completed with the existing physics-based model of the Thermal Energy Distribution System (TEDS)/Microreactor AGile Non-nuclear Experimental Testbed (MAGNET) facility at Idaho National Laboratory (INL). A Functional Mock-up Unit (FMU) of the physics-based system model and a reduced-order model (ROM) were both used to test for a preliminary hardware in the loop operation when the physical loop was offline. Future tasks could include improving the physics-based model to better match the available experimental data, improving the hardware in the loop integration, and improving the integration with the TEDS model.

14 SOLAR ENERGY↗

Waste Management Processing Projects in the PRC - 16551

EnergySolutions continues to provide waste treatment solutions in the Peoples Republic of China (PRC). In 2015 ES had completed installation of systems at two different Nuclear power sites (Haiyang, an AP-1000{sup TM} site and Yangjiang, a CPR1000 site). This paper discusses progress on these two projects, and provides new information regarding the operation of the systems. The Yangjiang project became operational in the fall of 2015 while the Haiyang project will be done is nearly done with commissioning and is waiting for reactor operations. Haiyang Project: In the Shandong Province on China's northeast coast, EnergySolutions, as part of a consortium with China Power Investment (CPI) and Yuanda Environmental Protection Engineering Company (a PRC state-owned company), has designed and constructed the site's Site Rad Waste Treatment Facility (SRTF). The SRTF provides solid waste processing services for up to 8 AP-1000s{sup TM}. The SRTF performs the following functions: 1. Five year storage for HICs containing spent resin and filters from the nuclear power plants' waste liquid systems (WLS); 2. Sorting and Compaction System for solid waste generated from Nuclear Power Plant (NPP) operations. This system implements: a) Real time radiography to screen 200 liter waste drums for prohibited items, b) Pre-compaction, c) High Resolution Gamma Spectrophotometry (HRGS) for waste characterization, d) Supercompaction, e) Solidification of compacted drums inside overpack drums which are filled with 60 MPa compressive strength grout, and f) Automatic drum lidding which crimps the drum lid to the drum body. 3. Laundry services for NPP anti-contamination clothing. 4. At the nuclear islands, EnergySolutions is providing mobile liquid waste processing systems that utilize EnergySolutions Advanced Liquid Processing System ALPS{sup TM}/Advanced Injection Method System AIM{sup TM} processing systems to supplement the NPP's WLS system when radionuclide concentrations exceed release criteria. The spent resins and filters from the nuclear power plants are placed in EnergySolutions supplied HICs, dewatered using EnergySolutions Self Engaging Dewatering System (SEDS{sup TM}), and then placed in EnergySolutions 8-120B Type B cask for the transport of the HIC between the NPP and the SRTF and, ultimately, to a disposal site once it is ready for operations Yangjiang Project: EnergySolutions is providing liquid waste treatment system (TEU) and solid waste treatment system (TES) for Yangjiang units 3 and 4 for the China Nuclear Power Engineering Company (CNPEC). The Yangjiang site is located approximately 300 kilometers west of Hong Kong. The TEU system processes floor drain, chemical drain, and process drain tanks liquids to achieve a release concentration less than 37 Bq/l. The TES system receives spent resin and filters into HIC containers which are dewatered and subsequently transported to the Yangjiang sites QT building where they are stored for a period of up to 5 years or until a disposal site are available. TEU (Liquid waste treatment) consists of the following unit operations: - ALPS{sup TM}/AIM{sup TM} system, which includes two separate 8 vessel water treatment systems that consist of granular activated carbon (GAC), cation, anion ion and mixed bed media ion exchange (IX) columns; and: - A reverse osmosis system for final polishing, - TES (solid waste system), - SEDS (Self Engaging Dewatering System), - Shielding for the loading and storage of HICs, - Shielded transport container for the transfer of HIC to the QT building for storage, - Shielded transfer bell for the transport of spent filters from the NPP operating area to HIC. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy Smart Management of Scientific Data

Scientific data centers comprised of high-powered computing equipment and large capacity disk storage systems consume considerable amount of energy. Dynamic power management techniques (DPM) are commonly used for saving energy in disk systems. These involve powering down disks that exhibit long idle periods and placing them in standby mode. A file request from a disk in standby mode will incur both energy and performance penalties as it takes energy (and time) to spin up the disk before it can serve a file. For this reason, DPM has to make decisions as to when to transition the disk into standby mode such that the energy saved is greater than the energy needed to spin it up again and the performance penalty is tolerable. The length of the idle period until the DPM decides to power down a disk is called idlenessthreshold. In this paper, we study both analytically and experimentally dynamic power management techniques that save energy subject to performance constraints on file access costs. Based on observed workloads of scientific applications and disk characteristics, we provide a methodology for determining file assignment to disks and computing idleness thresholds that result in significant improvements to the energy saved by existing DPMsolutions while meeting response time constraints. We validate our methods with simulations that use traces taken from scientific applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ROOT: A C++ framework for petabyte data storage, statistical analysis and visualization

ROOT is an object-oriented C++ framework conceived in the high-energy physics (HEP) community, designed for storing and analyzing petabytes of data in an efficient way. Any instance of a C++ class can be stored into a ROOT file in a machine-independent compressed binary format. In ROOT the TTree object container is optimized for statistical data analysis over very large data sets by using vertical data storage techniques. These containers can span a large number of files on local disks, the web or a number of different shared file systems. In order to analyze this data, the user can chose out of a wide set of mathematical and statistical functions, including linear algebra classes, numerical algorithms such as integration and minimization, and various methods for performing regression analysis (fitting). In particular, the RooFit package allows the user to perform complex data modeling and fitting while the RooStats library provides abstractions and implementations for advanced statistical tools. Multivariate classification methods based on machine learning techniques are available via the TMVA package. A central piece in these analysis tools are the histogram classes which provide binning of one- and multi-dimensional data. Results can be saved in high-quality graphical formats like Postscript and PDF or in bitmap formats like JPG or GIF. The result can also be stored into ROOT macros that allow a full recreation and rework of the graphics. Users typically create their analysis macros step by step, making use of the interactive C++ interpreter CINT, while running over small data samples. Once the development is finished, they can run these macros at full compiled speed over large data sets, using on-the-fly compilation, or by creating a stand-alone batch program. Finally, if processing farms are available, the user can reduce the execution time of intrinsically parallel tasks - e.g. data mining in HEP - by using PROOF, which will take care of optimally distributing the work over the available resources in a transparent way.

99 GENERAL AND MISCELLANEOUS↗

Hvac: Removing I/O Bottleneck for Large-Scale Deep Learning Applications

Scientific communities are increasingly adopting deep learning (DL) models in their applications to accelerate scientific discovery processes. However, with rapid growth in the computing capabilities of HPC supercomputers, large-scale DL applications have to spend a significant portion of training time performing I/O to a parallel storage system. Previous research works have investigated optimization techniques such as prefetching and caching. Unfortunately, there exist non-trivial challenges to adopting the existing solutions on HPC supercomputers for large-scale DL training applications, which include non-performance and/or failures at extreme scale, lack of portability and generality in design, complex deployment methodology, and being limited to a specific application or dataset. To address these challenges, we propose High-Velocity AI Cache (HVAC), a distributed read-cache layer that targets and fully exploits the node-local storage or near node-local storage technology. HVAC seamlessly accelerates read I/O by aggregating node-local or near node-local storage, avoiding metadata lookups and file locking while preserving portability in the application code. We deploy and evaluate HVAC on 1,024 nodes (with over 6000 NVIDIA V100 GPUS) of the Summit supercomputer. In particular, we evaluate the scalability, efficiency, accuracy, and load distribution of HVAC compared to GPFS and XFS-on-NVMe. With four different DL applications, we observe an average 25 % performance improvement atop GPFS and 9% drop against XFS-on-NVMe, which scale linearly and are considered the performance upper bound. We envision HVAC as an important caching library for upcoming HPC supercomputers such as Frontier.

Khan, Awais↗

Role of Cations in the Cation-Driven Assembly Process and their Effect on the Charge Storage Properties of Bilayered Vanadium Oxide and Reduced Graphene Oxide Heterostructures in Alkali Ion Systems

Exfoliated δ-Li x V 2 O 5 ·nH 2 O (ex-LVO) and reduced graphene oxide (rGO) heterostructures were constructed using different assembling cations (i.e., Li⁺, Na⁺, and K⁺ ions). The ex-LVO and rGO nanoflakes were stacked together using a concentrated chloride solution of each assembling cation and vacuum annealed at 200 °C to form three distinct two-dimensional (2D) layered architectures. X-ray diffraction and thermogravimetric analysis confirmed that the assembling ions can control the interlayer spacing of the bilayered vanadium oxide (BVO) phase as well as impact the crystallographic water content, which in turn affects the electrochemical performance. Scanning electron microscopy, scanning transmission electron microscopy (STEM), electron energy-loss spectroscopy (EELS), and X-ray photoelectron spectroscopy confirmed that a 2D heterointerface formed between LVO and rGO and that the cations used to assemble the heterostructure are trapped in the interlayer BVO region. High-resolution STEM imaging also showed the rGO dispersion throughout the LVO layers. Moreover, STEM-EELS identified a V 2 O 3 phase that forms along the rGO interface and can stabilize the materials during cycling. A charge storage mechanism analysis, combined with the galvanostatic intermittent titration technique, found that increased interlayer spacings of the BVO phase and using the assembling cations to define intercalation sites for identical charge-carrying ions lead to improved ion diffusion and increased capacities during cycling. Therefore, the Li⁺ and Na⁺ ion assembled heterostructures showed improved charge-carrying ion diffusion and charge storage capacities in each of their respective charge storage systems (i.e., Li-ion and Na-ion half-cells). In total, the cation used for heterostructure assembly can modify the final material structure and tailor the ion diffusion and charge storage capacity to tune its properties for the desired electrochemical system using a variety of 2D materials.

25 ENERGY STORAGE↗

One System Overview - 16579

The U.S. Department of Energy (DOE), Office of River Protection (ORP) is responsible for managing and completing the River Protection Project mission, which is to 'safeguard the nuclear waste stored in Hanford's 177 underground tanks, and to manage the waste safely and responsibly until it can be treated in the Waste Treatment and Immobilization Plant for final disposition'. The Office of River Protection's work scope is currently performed through two primary contracts: - The Tank Operations Contract, held by Washington River Protection Solutions LLC, (WRPS) includes the construction, operation, and maintenance activities necessary to safely store, retrieve, and transfer tank wastes; provide supplemental tank waste treatment; provide storage and/or disposal of primary and secondary waste streams; design, construction and commissioning of the Low-Activity Waste Pretreatment System; and support ORP to integrate Hanford Tank Waste Treatment and Immobilization Plant (WTP) completion and startup with Tank Farms operations. - The WTP Contract, held by Bechtel National, Inc. (BNI), includes the design, construction, and commissioning of a Pretreatment Facility, two vitrification facilities (one for high-level waste and one for low-activity waste), a dedicated analytical laboratory, and supporting facilities to treat radioactive tank wastes by immobilizing them into a stable glass waste form. One System was established as a means to improve the integration between the tank farms and the WTP project to support its safe and successful startup. One System's scope and purpose focus on mission integration consistent with DOE's plans to treat tank waste in phases, starting with direct feed of the low-activity waste stream to the WTP's Low-Activity Waste (LAW) Vitrification Facility (referred to as DFLAW). The One System organization now has four major focus areas: - Flowsheet Integration? Integrated River Protection Project (RPP) flowsheet development and management; developing a gaps, risks, and opportunities management plan and technical roadmap; and waste feed qualification. - Mission Analysis and Planning? Strategic planning, system planning, and modeling integration. - WTP Startup, Commissioning, and Operations Integration? Interface Control Document (ICD) management, coordinating facilities startup-to-commissioning-to-operations, contract directives and standards identification, and DFLAW program integration. - Project Integration and Controls? Integrated schedule, metrics/dashboards monitoring, and One System risk register. ORP established the DFLAW Program Office in February 2015 as one of its key performance goals. ORP staff, along with contractor managers, have identified roles and responsibilities for the each of the four major focus areas. One System has established an Executive Council and Governance Board to drive program progress and make decisions on DFLAW. This approach allows appropriate government and contractor senior management involvement in the DFLAW Program. Monthly critical path analysis on the integrated DFLAW schedule is being performed. Interface control documents specific to DFLAW have been developed, and system planning and modeling tools are being used to help define the DFLAW flowsheet. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗