Search NASA⌕ Search

SEARCH · Search NASA

Results for “High precision control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

E-Beam Generated Plasma Etching for Developing High-Reflectance Mirrors for Far-Ultraviolet Astronomical Instrument Applications

Astronomical space telescopes to study astrophysical phenomena from the far-ultraviolet (FUV) to the near infrared (NIR) will require mirror coatings with high reflectance over this entire spectral region. While coatings for the optical and NIR part of the spectrum are fairly well developed with proven performance, the FUV presents significant challenges. The U.S. Naval Research Laboratory (NRL) has developed a processing system based on an electron beam-generated plasma that provides for controlled fluorination and/or etching of surfaces with near monolayer precision and minimal changes to surface morphology. In this paper, we report recent results of samples treated in the NRL Large Area Plasma Processing System (LAPPS) where restoration of the high intrinsic reflectance in the FUV spectral range have been observed of aluminum (Al) mirrors protected with a magnesium di-fluoride (MgF2) overcoat. This paper will also extend these studies to other Al mirrors protected with aluminum tri-fluoride (AlF3) in order to realize the high intrinsic reflectance Al down to FUV wavelengths (100−200 nm), while still maintaining the high reflectance in the optical and NIR spectral regions. Laboratory test data and optical diagnostic techniques used to verify surface scattering and durability of selected coatings will be presented. Finally, we will discuss the scalability of the LAPPS etching process in order to realize these high-reflectivity coatings on mirror segments as large as those proposed for the Large Ultraviolet, Optical, and Infrared (LUVOIR) astronomical telescope system (1+meter class).

LUVOIR↗

New hardware and software platform for experiments on a HUBER-5042 X-ray diffractometer with a DISPLEX DE-202 helium cryostat in the temperature range of 20–300 K

Huber-5042 diffractometer with a closed-cycle Displex DE-202 helium cryostat is a unique scientific instrument for carrying out X-ray diffraction experiments when studying the single crystal structure in the temperature range of 20–300 K. To make the service life longer and develop new experimental techniques, the diffractometer control is transferred to a new hardware and software platform. To this end, a modern computer; a new detector reader unit; and new control interfaces for stepper motors, temperature controller, and cryostat vacuum pumping system are used. The system for cooling the X-ray tube, the high-voltage generator, and the helium compressor and pump for maintaining the desired vacuum in the cryostat are replaced. The system for controlling the primary beam shutter is upgraded. A biological shielding is installed. The new program tools, which use the Linux Ubuntu operating system and SPEC constructor, include a set of drivers for control units through the aforementioned interfaces. A program for searching reflections from a sample using fast continuous scanning and a priori information about crystal is written. Thus, the software package for carrying out the complete cycle of precise diffraction experiment (from determining the crystal unit cell to calculating the integral reflection intensities) is upgraded. High quality of the experimental data obtained on this equipment is confirmed in a number of studies in the temperature range from 20 to 300 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Piezoelectric Polymers Actuators for Precise Shape Control of Large Scale Space Antennas

Extremely large, lightweight, in-space deployable active and passive microwave antennas are demanded by future space missions. This paper investigates the development of PVDF based piezopolymer actuators for controlling the surface accuracy of a membrane reflector. Uniaxially stretched PVDF films were poled using an electrodeless method which yielded high quality poled piezofilms required for this application. To further improve the piezoperformance of piezopolymers, several PVDF based copolymers were examined. It was found that one of them exhibits nearly three times improvement in the in-plane piezoresponse compared with PVDF and P(VDF-TrFE) piezopolymers. Preliminary experimental results indicate that these flexible actuators are very promising in controlling precisely the shape of the space reflectors.

actuators↗

Transpiration-purged optical probe: a novel sensor for high temperature harsh environments

Typical control systems that are found in modern power plants must control the many physical aspects of the complex processes that occur inside the various components of the power plant. As detection and monitoring of pollutants becomes increasingly important to plant operation, these control systems will become increasingly complex, and will depend upon accurate monitoring of the concentration levels of the various chemical species that are found in the gas streams. In many cases this monitoring can be done optically. Optical access can also be used to measure thermal emissions and the particulate loading levels in the fluid streams. Some typical environments were optical access is needed are combustion chambers, reactor vessels, the gas and solid flows in fluidized beds, hot gas filters and heat exchangers. These applications all have harsh environments that are at high temperatures and pressures. They are often laden with products of combustion and other fine particulate matter which is destructive to any optical window that could be used to monitor the processes in these environments in order to apply some control scheme over the process. The dust and char that normally collects on the optical surfaces reduces the optical quality and thus impairs the ability of the optical surface to transmit data. Once this has occurred, there is generally no way to clean the optical surface during operation. The probe must be dismounted from the vessel, disassembled and cleaned or replaced, then remounted. This would require the shutdown of the particular component of the plant where optical monitoring is required. This renders the probe ineffective to be used as the monitoring part of any control system application. The components of optical monitoring equipment are usually built in supporting structures that require precise alignment. This is almost always accomplished using fine scale adjustments to specialized mounting hardware that is attached to the reactor vessel. When the temperature of these supporting structures increases due to the high temperature process that is occurring inside the vessel, the optical alignment can often suffer due to the thermal expansion of the mounting structure. This can render them useless especially for gas velocity measurements or other situations where precise optical alignment is required. What is needed is an optical probe that can be inserted into any hazardous environment that will not suffer alignment problems or other failure modes that are related to high temperature dirty environments, and at the same time maintain a clean optical surface through the lifetime of the devise so that it may be continually used for optical inspection or for control system applications. This paper describes details of the construction and the use of a transpiration purged optical probe which mitigates the problems that are outlined above. The transpiration probe may be used as either an emitter or a detector. The probe is implemented in the harsh high temperature environment of the NETL pulsed combustion system where products of combustion and particulate matter have been shown to degrade the performance of a normal optical window. Assessments of combustion heat release are made by monitoring the ultraviolet signatures that are produced by the concentration of OH during a pulsed combustion process. It is shown that these measurements are directly correlated with the pressure within the pulsed combustor. Probe temperature measurements are also presented to show how the probe and its mounting hardware remain at constant temperatures well below the high temperature environment which they monitor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study of semi-inclusive deep inelastic (e,e'{pi}{sup {+-}}) production with a polarized {sup 3}He target

The 12 GeV upgrade at Jefferson Lab will open a new era of precision measurement of the Transverse Momentum Dependent parton distribution functions (TMDs) through the Semi-Inclusive Deep-Inelastic Scattering (SIDIS). In this talk, we discussed the projected results on measurements of TMDs using a newly proposed large acceptance solenoid detector together with the standard Hall A polarized {sup 3}He target. The high luminosity and the large acceptance detector will allow for a precise 3-D (x, z and P{sub T}) mapping of azimuthal asymmetries. Furthermore, the full 2{pi} azimuthal angular coverage for the solenoid detector is essential to control the relevant systematic uncertainties in extracting the azimuthal asymmetries. With a 40 cm long transversely polarized {sup 3}He target, a total of 60 days of beam time at a beam current of 15 {mu}A, we can determine tensor charge of d quark to 10% in a model independent way. The extracted Sivers asymmetry will provide important information to understand the correlation between the quark orbital angular momentum and the nucleon spin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HIL Testbed and Motion Control Strategy for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) was proposed in recent years to increase system efficiency of high power mobile machines and to reap the benefits of electrification without the need for large electric machines. It uses a set of common pressure rails to provide the majority of power hydraulically and small electric motors to modulate that power for precise control. This paper presents the development of a Hardware-in-the-loop (HIL) test-bed for testing motion control strategies for the HHEA. Precise motion control is important for off-road vehicles whose utility requires the machine being dexterous and performing tasks exactly as commanded. Motion control for the HHEA is challenging due to its intrinsic use of discrete pressure rail switches to minimize system efficiency or to keep the system within the torque capabilities of the electric motor. The motion control strategy utilizes two different controllers: a nominal passivity based back-stepping controller used in between pressure rail switches and a transition controller used to handle the event of a pressure rail switch. In this paper, the performance of the nominal control under various nominal and rail switching scenarios is experimentally evaluated on the HIL testbed.

33 ADVANCED PROPULSION SYSTEMS↗

Developing Magnetorheological Finishing (MRF) Technology for the Manufacture of Large-Aperture Optics in Megajoule Class Laser Systems

Over the last eight years we have been developing advanced MRF tools and techniques to manufacture meter-scale optics for use in Megajoule class laser systems. These systems call for optics having unique characteristics that can complicate their fabrication using conventional polishing methods. First, exposure to the high-power nanosecond and sub-nanosecond pulsed laser environment in the infrared (>27 J/cm{sup 2} at 1053 nm), visible (>18 J/cm{sup 2} at 527 nm), and ultraviolet (>10 J/cm{sup 2} at 351 nm) demands ultra-precise control of optical figure and finish to avoid intensity modulation and scatter that can result in damage to the optics chain or system hardware. Second, the optics must be super-polished and virtually free of surface and subsurface flaws that can limit optic lifetime through laser-induced damage initiation and growth at the flaw sites, particularly at 351 nm. Lastly, ultra-precise optics for beam conditioning are required to control laser beam quality. These optics contain customized surface topographical structures that cannot be made using traditional fabrication processes. In this review, we will present the development and implementation of large-aperture MRF tools and techniques specifically designed to meet the demanding optical performance challenges required in large-aperture high-power laser systems. In particular, we will discuss the advances made by using MRF technology to expose and remove surface and subsurface flaws in optics during final polishing to yield optics with improve laser damage resistance, the novel application of MRF deterministic polishing to imprint complex topographical information and wavefront correction patterns onto optical surfaces, and our efforts to advance the technology to manufacture large-aperture damage resistant optics.

42 ENGINEERING↗

Deep Understanding of Strong Metal Interface Confinement: A Journey of Pd/FeO x Catalysts

Tuning the atomic interface configuration of noble metals (NMs) and transition-metal oxides is an effective straightforward yet challenging strategy to modulate the activity and stability of heterogeneous catalysts. Herein, Pd supported on mesoporous Fe 2 O 3 with a high specific surface area was rationally designed and chosen to construct the Pd/iron oxide interface. As a versatile model, the physicochemical environments of Pd nanoparticles (NPs) could be precisely controlled by taming the reduction temperature. The experimental and density functional theory calculation results unveiled that the catalyst in the support–metal interface confinement (SMIC) state showed significantly enhanced catalytic activity and sintering resistance for CO oxidation. The constructed Fe sites at the interfaces between FeO x overlayers and Pd NPs not only provided additional coordinative unsaturated ferrous sites for the adsorption and activation of O 2 , thereby facilitating the activation efficiency of O 2 , but also impressively changed the reaction pathway of CO oxidation. As a result, the catalyst followed the Pd/Fe dual-site mechanism instead of the classical Mars–van Krevelen mechanism. For the catalyst in the strong metal–support interaction (SMSI) state, its catalytic activity was seriously suppressed because of the excessive encapsulation of the active Pd sites by FeO x overlayers. Thus, the present study therefore provides detailed insights into the SMIC and SMSI in ferric oxide-supported Pd catalysts, which could guide the preparation of highly efficient supported catalysts for practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Modeling Tools for Thermal Analysis and Applications

Integrated modeling of spacecraft systems is a rapidly evolving area in which multidisciplinary models are developed to design and analyze spacecraft configurations. These models are especially important in the early design stages where rapid trades between subsystems can substantially impact design decisions. Integrated modeling is one of the cornerstones of two of NASA's planned missions in the Origins Program -- the Next Generation Space Telescope (NGST) and the Space Interferometry Mission (SIM). Common modeling tools for control design and opto-mechanical analysis have recently emerged and are becoming increasingly widely used. A discipline that has been somewhat less integrated, but is nevertheless of critical concern for high precision optical instruments, is thermal analysis and design. A major factor contributing to this mild estrangement is that the modeling philosophies and objectives for structural and thermal systems typically do not coincide. Consequently the tools that are used in these discplines suffer a degree of incompatibility, each having developed along their own evolutionary path. Although standard thermal tools have worked relatively well in the past. integration with other disciplines requires revisiting modeling assumptions and solution methods. Over the past several years we have been developing a MATLAB based integrated modeling tool called IMOS (Integrated Modeling of Optical Systems) which integrates many aspects of structural, optical, control and dynamical analysis disciplines. Recent efforts have included developing a thermal modeling and analysis capability, which is the subject of this article. Currently, the IMOS thermal suite contains steady state and transient heat equation solvers, and the ability to set up the linear conduction network from an IMOS finite element model. The IMOS code generates linear conduction elements associated with plates and beams/rods of the thermal network directly from the finite element structural model. Conductances for temperature varying materials are accommodated. This capability both streamlines the process of developing the thermal model from the finite element model, and also makes the structural and thermal models compatible in the sense that each structural node is associated with a thermal node. This is particularly useful when the purpose of the analysis is to predict structural deformations due to thermal loads. The steady state solver uses a restricted step size Newton method, and the transient solver is an adaptive step size implicit method applicable to general differential algebraic systems. Temperature dependent conductances and capacitances are accommodated by the solvers. In addition to discussing the modeling and solution methods. applications where the thermal modeling is "in the loop" with sensitivity analysis, optimization and optical performance drawn from our experiences with the Space Interferometry Mission (SIM), and the Next Generation Space Telescope (NGST) are presented.

Milman, Mark H.↗

Development and Testing of a High-Precision Position and Attitude Measuring System for a Space Mechanism

This paper describes a high-precision optical metrology system - a unique ground test equipment which was designed and implemented for simultaneous precise contactless measurements of 6 degrees-of-freedom (3 translational + 3 rotational) of a space mechanism end-effector [1] in a thermally controlled ISO 5 clean environment. The developed contactless method reconstructs both position and attitude of the specimen from three cross-sections measured by 2D distance sensors [2]. The cleanliness is preserved by the hermetic test chamber filled with high purity nitrogen. The specimen's temperature is controlled by the thermostat [7]. The developed method excludes errors caused by the thermal deformations and manufacturing inaccuracies of the test jig. Tests and simulations show that the measurement accuracy of an object absolute position is of 20 micron in in-plane measurement (XY) and about 50 micron out of plane (Z). The typical absolute attitude is determined with an accuracy better than 3 arcmin in rotation around X and Y and better than 10 arcmin in Z. The metrology system is able to determine relative position and movement with an accuracy one order of magnitude lower than the absolute accuracy. Typical relative displacement measurement accuracies are better than 1 micron in X and Y and about 2 micron in Z. Finally, the relative rotation can be measured with accuracy better than 20 arcsec in any direction.

Khanenya, Nikolay↗

How to Compute a Slot Marker - Calculation of Controller Managed Spacing Tools for Efficient Descents with Precision Scheduling

This paper describes the underlying principles and algorithms for computing the primary controller managed spacing (CMS) tools developed at NASA for precisely spacing aircraft along efficient descent paths. The trajectory-based CMS tools include slot markers, delay indications and speed advisories. These tools are one of three core NASA technologies integrated in NASAs ATM technology demonstration-1 (ATD-1) that will operationally demonstrate the feasibility of fuel-efficient, high throughput arrival operations using Automatic Dependent Surveillance Broadcast (ADS-B) and ground-based and airborne NASA technologies for precision scheduling and spacing.

efficient arrivals↗

Designing Low Tortuosity Electrodes through Pattern Optimization for Fast-Charging

The development of fast-charging technologies is crucial for expediting the progress and promotion of electric vehicles. In addition to innovative material exploration, reduction in the tortuosity of electrodes is a favored strategy to enhance the fast-charging capability of lithium-ion batteries by optimizing the ion-transfer kinetics. To realize the industrialization of low-tortuosity electrodes, a facile, cost-effective, highly controlled, and high-output continuous additive manufacturing roll-to-roll screen printing technology is proposed to render customized vertical channels within electrodes. Extremely precise vertical channels are fabricated by applying the as-developed inks, using LiNi 0.6 Mn 0.2 Co 0.2 O 2 as the cathode material. Additionally, the relationship between the electrochemical properties and architecture of the channels, including the pattern, channel diameter, and edge distance between channels, is revealed. The optimized screen-printed electrode exhibited a seven-fold higher charge capacity (72 mAh g -1 ) at a current rate of 6 C and superior stability compared with that of the conventional bar-coated electrode (10 mAh g -1 , 6 C) at a mass loading of 10 mg cm -2 . Finally, this roll-to-roll additive manufacturing can potentially be applied to various active materials printing to reduce electrode tortuosity and enable fast charging in battery manufacturing.

42 ENGINEERING↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

A novel low-rank matrix completion approach to estimate missing entries in Euclidean distance matrix

A Euclidean distance matrix (EDM) is a table of distance-square between points on a k-dimensional Euclidean space, with applications in many fields (e.g., engineering, geodesy, economics, genetics, biochemistry, and psychology). A problem that often arises is the absence (or uncertainty) of some EDM elements. In many situations, only a subset of all pairwise distances is available and it is desired to have some procedure to estimate the missing distances. In this paper, we address the problem of missing data in EDM through low-rank matrix completion techniques. We exploit the fact that the rank of a EDM is at most k+2 and does not depend on the number of points, which is, in general, much bigger then k. We use a singular value decomposition approach that considers the rank of the matrix to be completed and computes, in each iteration, a parameter that controls the convergence of the method. After performing a number of computational experiments, we could observe that our proposal was able to recover, with high precision, random EDMs with more than 1000 points and up to 98% of missing data in few minutes. In addition, our method required a smaller number of iterations when compared to other competitive state-of-art technique.

97 MATHEMATICS AND COMPUTING↗

Solid-phase hetero epitaxial growth of α-phase formamidinium perovskite

Conventional epitaxy of semiconductor films requires a compatible single crystalline substrate and precisely controlled growth conditions, which limit the price competitiveness and versatility of the process. We demonstrate substrate-tolerant nano-heteroepitaxy (NHE) of high-quality formamidinium-lead-tri-iodide (FAPbI 3 ) perovskite films. The layered perovskite templates the solid-state phase conversion of FAPbI 3 from its hexagonal non-perovskite phase to the cubic perovskite polymorph, where the growth kinetics are controlled by a synergistic effect between strain and entropy. The slow heteroepitaxial crystal growth enlarged the perovskite crystals by 10-fold with a reduced defect density and strong preferred orientation. This NHE is readily applicable to various substrates used for devices. The proof-of-concept solar cell and light-emitting diode devices based on the NHE-FAPbI 3 showed efficiencies and stabilities superior to those of devices fabricated without NHE.

36 MATERIALS SCIENCE↗

ANALYSIS OF KEPLER'S SHORT-CADENCE PHOTOMETRY FOR TrES-2b

We present an analysis of 18 short-cadence (SC) transit light curves of TrES-2b using quarter 0 (Q0) and quarter 1 (Q1) from the Kepler Mission. The photometry is of unprecedented precision, 237 ppm minute{sup -1}, allowing for the most accurate determination of the transit parameters yet obtained for this system. Global fits of the transit photometry, radial velocities, and known transit times are used to obtain a self-consistent set of refined parameters for this system, including updated stellar and planetary parameters. Special attention is paid to fitting for limb darkening and eccentricity. We place an upper limit on the occultation depth to be <72.9 ppm to 3{sigma} confidence, indicating TrES-2b has the lowest determined geometric albedo for an exoplanet, of A{sub g} < 0.146. We also produce a transit timing analysis using Kepler's SC data and demonstrate exceptional timing precision at the level of a few seconds for each transit event. With 18 fully sampled transits at such high precision, we are able to produce stringent constraints on the presence of perturbing planets, Trojans, and extrasolar moons. We introduce the novel use of control data to identify phasing effects. We also exclude the previously proposed hypotheses of short-period transit time variation and additional transits but find that the hypothesis of long-term inclination change is neither supported nor refuted by our analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Frequency Matching in Light-Storage Spectroscopy of Atomic Raman Transitions

We investigate the storage of light in an atomic sample with a LAMBDA-type coupling scheme driven by optical fields at variable two-photon detuning. In the presence of electromagnetically induced transparency (EIT), light is stored and retrieved from the sample by dynamically varying the group velocity. It is found that for any two-photon detuning of the input light pulse within the EIT transparency window, the carrier frequency of the retrieved light pulse matches the two-photon resonance frequency with the atomic ground state transition and the control field. This effect which is not based on spectral filtering is investigated both theoretically and experimentally. It can be used for high-speed precision measurements of the two-photon resonance as employed, e.g., in optical magnetometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrochemical Synthesis of Polycrystalline Semiconductor Electrodes with Controlled Compositions and Morphologies for Use in Solar Fuel Production

The major goal of our research during the previous funding period was to gain the ability in electrochemical synthesis to precisely control compositions and morphologies of various oxide-based polycrystalline photoelectrodes in order to establish the composition-morphology photoelectrochemical property relationships while discovering highly efficient photoelectrode systems for use in solar energy conversion. The most significant achievements made during June 2011-May 2012 are summarized below.

08 HYDROGEN↗