Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Observation of Low-Energy Proton Direct Ionization in a 72-Layer 3D NAND Flash Memory

Single-event upsets are observed in a 72-layer 3D NAND flash memory operated in single-level cell mode after low-energy proton (500 keV-1.2 MeV) and heavy ion irradiation. The layer-by-layer error count is analyzed to visualize the stopping of low energy protons within the memory stack, and Monte Carlo simulations are correlated with the experimental data. Direct ionization by low-energy protons is identified by three-dimensional data analysis and the energy dependence of device sensitive cross-section. Heavy ion data is also presented for comparison.

Direct ionization↗

A Polymer Canvas with the Stiffness of the Bone Matrix to Study and Control Mesenchymal Stem Cell Response

Reproducing in vitro the complex multiscale physical features of human tissues creates novel biomedical opportunities and fundamental understanding of cell–environment interfaces and interactions. While stiffness has been recognized as a key driver of cell behavior, systematic studies on the role of stiffness have been limited to values in the KPa–MPa range, significantly below the stiffness of bone. Here, in this work, a platform enabling the tuning of the stiffness of a biocompatible polymeric interface up to values characteristic of human bone is reported, which are in the GPa range, by using extremely thin polymer films on glass and cross-linking the films using ultraviolet (UV) light irradiation. It is shown that a higher stiffness is related to better adhesion, proliferation, and osteogenic differentiation, and that it is possible to switch on/off cell attachment and growth by solely tuning the stiffness of the interface, without any surface chemistry or topography modification. Since the stiffness is tuned directly by UV irradiation, this platform is ideal for rapid and simple fabrication of stiffness patterns and gradients, thus representing an innovative tool for combinatorial studies of the synergistic effect of tissue environmental cues on cell behavior, and creates new opportunities for next-generation biosensors, single-cell patterning, and lab-on-a-chip devices.

60 APPLIED LIFE SCIENCES↗

Photoelectric conversion on Earth’s surface via widespread Fe- and Mn-mineral coatings

Sunlight drives photosynthesis and associated biological processes, and also influences inorganic processes that shape Earth’s climate and geochemistry. Bacterial solar-to-chemical energy conversion on this planet evolved to use an intricate intracellular process of phototrophy. However, a natural nonbiological counterpart to phototrophy has yet to be recognized. In this work, we reveal the inherent “phototrophic-like” behavior of vast expanses of natural rock/soil surfaces from deserts, red soils and karst environments, all of which can drive photon-to-electron conversions. Using scanning electron microscopy, transmission electron microscopy, micro-Raman spectroscopy and X-ray absorption spectroscopy, Fe and Mn (oxyhydr)oxide-rich coatings were found in rock varnishes, as were Fe (oxyhydr)oxides on red soil surfaces and minute amounts of Mn oxides on karst rock surfaces. By directly fabricating a photoelectric detection device on the thin section of a rock varnish sample, we have recorded the first in situ photocurrent micromapping of the coatings, which behave as highly sensitive and stable photoelectric systems. Additional measurements of red soil and powder separated from the outermost surface of karst rocks yielded photocurrents that are also sensitive to irradiation. The prominent solar-responsive capability of the phototrophic-like rocks/soils is ascribed to the semiconducting Fe and Mn (oxyhydr)oxide mineral coatings. The native semiconducting Fe/Mn-rich coatings may play a role similar in part to photosynthetic systems and thus provide a distinctive driving force for redox (bio)geochemistry on Earth’s surfaces.

Lu, Anhuai↗

RADIOLOGICAL SEALED SOURCE LIBRARY: A NUCLEAR FORENSICS TOOL

If a terrorist were to obtain and possibly detonate a device that contained radiological material, radiological forensic analysis of the material and source capsule could provide law enforcement with valuable clues about the origin of the radiological material; this information could then provide further leads on where the material and sealed source was obtained, and the loss of control point. This information could potentially be utilized for attribution and prosecution. Analyses of nuclear forensic signatures for radiological materials are generally understood to include isotopic ratios, trace element concentrations, the time since irradiation or purification, and morphology. Radiological forensic signatures for sealed sources provide additional information that leverages information on the physical design and chemical composition of the source capsule and containers, physical markings indicative of an owner or manufacturer. Argonne National Laboratory (Argonne), in collaboration with Idaho National Laboratory (INL), has been working since 2003 to understand signatures that could be used to identify specific source manufacturers. These signatures include the materials from which the capsule is constructed, dimensions, weld details, elemental composition, and isotopic abundances of the radioactive material. These signatures have been compiled in a library known as the Argonne/INL Radiological Sealed Source Library. Data collected for the library has included open-source information from vendor catalogs and web pages; discussions with source manufacturers and touring of production facilities (both protected through non-disclosure agreements); technical publications; and government registries such as the U.S. Nuclear Regulatory Commission’s Sealed Source and Device Registry.

National Nuclear Forensics Library↗

Subcutaneous power supply by NIR-II light

Implantable medical devices are wished to be recharged via contactless power transfer technologies without interventional operations. Superior to subcutaneous power supply by visible light or electromagnetic wave, second near-infrared (NIR-II) light is predicted to possess 60 times subcutaneous power transmission but hard to be utilized. Here we report a photo-thermal-electric converter via the combination of photothermal conversion and thermoelectric conversion. It is able to generate an output power as high as 195 mW under the coverage of excised tissues, presenting advantages of non-invasion, high output power, negligible biological damage, and deep tissue penetration. As an in vivo demonstration, the output power of a packaged converter in the abdominal cavity of a rabbit reaches 20 mW under NIR-II light irradiation through the rabbit skin with a thickness of 8.5 mm. This value is high enough to recharge an implanted high-power-consumption wireless camera and transfer video signal out of body in real-time.

60 APPLIED LIFE SCIENCES↗

Aerospace devices for magnetic replicas

Retained persistent magnetic field has been studied and improved in the superconductor YBa2Cu3O7 (Y123). During the study, trapped magnetic field, B(t), has been increased by over a factor of 10(exp 5). Methods used to improve magnetic field trapping were principally: (1) the adoption of the Melt Texturing process to increase grain size; (2) the addition of excess Y to disperse deposits of Y2BaCuO5 (Y211) and again increase grain size; (3) irradiation with high energy particles including 1H+, 3He++, 4He++, and fission fragments; and (4) utilizing temperatures below 77 K has also been quantified as a way to increase trapped field. In addition, in our study of B(t), we have found laws governing creep, activation, temperature dependence, creep vs. current flow, etc. In the range 20 K less than or equal to T less than or equal to 65 K, and for B less than 10 Tesla, a simple empirical relationship was found: B(trap) (T2) = B(trap) (T1) ((Tc - T2)/(Tc - T1))squared where Tc is the critical temperature. The highest experimental trapped field was B(trap) = 3.96 Tesla, at 65 K. We believe this to be the highest persistent field ever produced, by any method. A two component model of the persistent currents has been developed. This accurately reproduces the data, using as parameters only the magnitude of a constant surface current, J(s), and a constant volume current J(v). The model successfully predicts B(t) (xyz) for the case of maximum trapped field, for all samples observed. It has also been extended to describe the unsaturated case either zero field cooled, or field cooled. Loss of strap with time has been studied for the critical state (Bt,max), and non critical state (Bt less than Bt,max), for times from a few minutes to a few months, for unirradiated material, for irradiation by 1H+, 3He++, 4He++, high z projectiles, and neutrons, and for all materials used in the overall study. We conclude that: (1) multi Tesla trapped fields are attained; (2) fields over 10 T are achievable; (3) creep is not a large problem; (4) application is feasible to motors, generators, magnets for particle beam optics, separators, levitating bearings, energy storage, shielding, and transportation.

Weinstein, Roy↗

Bright and stable light-emitting diodes made with perovskite nanocrystals stabilized in metal–organic frameworks

Perovskite nanocrystals are exceptional candidates for light-emitting diodes (LEDs). However, they are unstable in the solid film and tend to degrade back to the bulk phase, which undermines their potential for LEDs. Here we demonstrate that perovskite nanocrystals stabilized in metal–organic framework (MOF) thin films make bright and stable LEDs. The perovskite nanocrystals in MOF thin films can maintain the photoluminescence and electroluminescence against continuous ultraviolet irradiation, heat and electrical stress. As revealed by optical and X-ray spectroscopy, the strong emission originates from localized carrier recombination. Bright LEDs made from perovskite-MOF nanocrystals are demonstrated with a maximum external quantum efficiency of over 15% and a high brightness of over 10 5 cd m -2 after the device reaches stabilization. During LED operation, the nanocrystals can be well preserved, free of ion migration or crystal merging through protection by the MOF matrix, leading to a stable performance over 50 hours.

36 MATERIALS SCIENCE↗

Time delay and integration array (TDI) using charge transfer device technology. Phase 2, volume 1: Technical

The 20x9 TDI array was developed to meet the LANDSAT Thematic Mapper Requirements. This array is based upon a self-aligned, transparent gate, buried channel process. The process features: (1) buried channel, four phase, overlapping gate CCD's for high transfer efficiency without fat zero; (2) self-aligned transistors to minimize clock feedthrough and parasitic capacitance; and (3) transparent tin oxide electrode for high quantum efficiency with front surface irradiation. The requirements placed on the array and the performance achieved are summarized. This data is the result of flat field measurements only, no imaging or dynamic target measurements were made during this program. Measurements were performed with two different test stands. The bench test equipment fabricated for this program operated at the 8 micro sec line time and employed simple sampling of the gated MOSFET output video signal. The second stand employed Correlated Doubled Sampling (CDS) and operated at 79.2 micro sec line time.

Source record↗

Magnetic properties of intercalated quasi-2D Fe 3-x GeTe 2 van der Waals magnet

Among several well-known transition metal-based compounds, cleavable van der Waals (vdW) Fe 3-x GeTe 2 (FGT) magnet is a strong candidate for use in two-dimensional (2D) magnetic devices due to its strong perpendicular magnetic anisotropy, sizeable Curie temperature (T C ~154 K), and versatile magnetic character that is retained in the low-dimensional limit. While the T C remains far too low for practical applications, there has been a successful push toward improving it via external driving forces such as pressure, irradiation, and doping. Here we present experimental evidence of a room temperature (RT) ferromagnetic phase induced by the electrochemical intercalation of common tetrabutylammonium cations (TBA+) into quasi-2D FGT. We obtained Curie temperatures as high as 350 K with chemical and physical stability of the intercalated compound. The temperature-dependent Raman measurements, in combination with vdW-corrected ab initio calculations, suggest that charge transfer (electron doping) upon intercalation could lead to the observation of RT ferromagnetism. This work demonstrates that molecular intercalation is a viable route in realizing high-temperature vdW magnets in an inexpensive and reliable manner and has the potential to be extended to bilayer and few-layer vdW magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Raman spectroscopy and electrical properties of InAs nanowires with local oxidation enabled by substrate micro-trenches and laser irradiation

The thermal gradients along indium arsenide nanowires were engineered by a combination of fabricated micro-trenches in the supporting substrate and focused laser irradiation. This allowed local spatial control of thermally activated oxidation reactions of the nanowire on the scale of the diffraction limit. The locality of the oxidation was detected by micro-Raman mapping, and the results were found to be consistent with numerical simulations of the temperature profile. Applying the technique to nanowires in electrical devices the locally oxidized nanowires remained conducting with a lower conductance as expected for an effectively thinner conducting core.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring

Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Results: Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80 000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% − 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Conclusions: Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.

60 APPLIED LIFE SCIENCES↗

Deep levels and radiation effects in p-InP

A survey was conducted on past studies of hole traps in InP. An experiment was designed to evaluate hole traps in Zn-doped InP after fabrication, after electron irradiation and after annealing using deep level transient spectroscopy. Data similar to that of Yamaguchi was seen with observation of both radiation-induced hole and electron traps at E sub A=0.45 eV and 0.03 eV, respectively. Both traps are altered by annealing. It is also shown that trap parameters for surface-barrier devices are influenced by many factors such as bias voltage, which probes traps at different depths below the surface. These devices require great care in data evaluation.

Anderson, W. A.↗

SU-D-BRE-05: Feasibility and Limitations of Laser-Driven Proton Therapy: A Treatment Planning Study

Purpose: Laser-acceleration of particles may offer a cost- and spaceefficient alternative for future radiation therapy with particles. Laser-driven particle beams are pulsed with very short bunch times, and a high number of particles is delivered within one laser shot which cannot be portioned or modulated during irradiation. The goal of this study was to examine whether good treatment plans can be produced for laser-driven proton beams and to investigate the feasibility of a laser-driven treatment unit. Methods: An exponentially decaying proton spectrum was tracked through a gantry and energy selection beam line design to produce multiple proton spectra with different energy widths centered on various nominal energies. These spectra were fed into a treatment planning system to calculate spot scanning proton plans using different lateral widths of the beam and different numbers of protons contained in the initial spectrum. The clinical feasibility of the resulting plans was analyzed in terms of dosimetric quality and the required number of laser shots as an estimation of the overall treatment time. Results: We were able to produce treatment plans with plan qualities of clinical relevance for a maximum initial proton number per laser shot of 6*10{sup 8}. However, the associated minimum number of laser shots was in the order of 10{sup 4}, indicating a long delivery time in the order of at least 15 minutes, when assuming an optimistic repetition rate of the laser system of 10 Hz. Conclusion: With the simulated beam line and the assumed shape of the proton spectrum it was impossible to produce clinically acceptable treatment plans that can be delivered in a reasonable time. The situation can be improved by a method or a device in the beam line which can modulate the number of protons from shot to shot. Supported by DFG Cluster of Excellence: Munich-Centre for Advanced Photonics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced tunable magnetoresistance properties over a wide temperature range in epitaxial (La{sub 0.7}Sr{sub 0.3}MnO{sub 3}){sub 1−x}:(CeO{sub 2}){sub x} nanocomposites

Vertically aligned nanocomposite (VAN) (La{sub 0.7}Sr{sub 0.3}MnO{sub 3}){sub 1−x}:(CeO{sub 2}){sub x} (LSMO:CeO{sub 2}) thin films have been grown on SrTiO{sub 3} (001) substrates by pulsed laser deposition. Tunable magnetoresistance properties as well as microstructures are demonstrated in these VAN films by modulating the film composition (x = 0, 0.3, 0.4, 0.45, 0.5, and 0.55). The sample of x = 0.3 shows a large low-field magnetoresistance (LFMR) in a high temperature range, i.e., over 10% at the range of 280 K to 320 K under 1 T and with a peak value of ∼13.5% at 310 K. In addition, a vast enhancement of LFMR in a low temperature range of 20–150 K with peak of ≈34.3% at 45 K for 1 T could be achieved with x = 0.5. The enhanced LFMR properties can be attributed to both the phase boundary induced spin fluctuation and the magnetic tunneling effect through vertical ferromagnetic/insulator/ferromagnetic structures. The observed enhanced LFMR performance, especially at high temperatures, as well as its simple growth method, offers a great potential for LSMO:CeO{sub 2}nanocomposites to be used in spintronic devices in a large temperature range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-healing effects in a semi-ordered liquid for stable electronic conversion of high-energy radiation

Radiation damage in solid-state semiconductors has, until now, placed strict limitations on the acceptable decay energies of radioisotopes in radiovoltaic cells. Relegation to low-energy beta-emitting isotopes has minimized the power output from these devices and limited the technology’s ability to deliver greater energy densities and longer lifetimes than conventional batteries. We demonstrate the self-healing abilities of a liquid-phase semiconducting alloy which can withstand high-energy alpha radiation. Neutron difraction of liquid selenium-sulfur shows the liquid phase repairing damage sustained in the irradiation of the solid phase. This self-healing behavior results in long-lived power output in a liquid selenium-sulfur alphavoltaic cell. To the best of our knowledge, this marks the only successful demonstration of resistance to high-energy radiation (>500keV) in a semiconducting material. This new robustness can potentially allow increases to the available energy density in radiovoltaic cells near 1000 times the current state of the art.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TU-C-BRE-04: 3D Gel Dosimetry Using ViewRay On-Board MR Scanner: A Feasibility Study

Purpose: MR based 3D gel has been proposed for radiation therapy dosimetry. However, access to MR scanner has been one of the limiting factors for its wide acceptance. Recent commercialization of an on-board MR-IGRT device (ViewRay) may render the availability issue less of a concern. This work reports our attempts to simulate MR based dose measurement accuracy on ViewRay using three different gels. Methods: A spherical BANG gel dosimeter was purchased from MGS Research. Cylindrical MAGIC gel and Fricke gel were fabricated in-house according to published recipes. After irradiation, BANG and MAGIC were imaged using a dual-echo spin echo sequence for T2 measurement on a Philips 1.5T MR scanner, while Fricke gel was imaged using multiple spin echo sequences. Difference between MR measured and TPS calculated dose was defined as noise. The noise power spectrum was calculated and then simulated for the 0.35 T magnetic field associated with ViewRay. The estimated noise was then added to TG-119 test cases to simulate measured dose distributions. Simulated measurements were evaluated against TPS calculated doses using gamma analysis. Results: Given same gel, sequence and coil setup, with a FOV of 180×90×90 mm3, resolution of 3×3×3 mm3, and scanning time of 30 minutes, the simulated measured dose distribution using BANG would have a gamma passing rate greater than 90% (3%/3mm and absolute). With a FOV 180×90×90 mm3, resolution of 4×4×5 mm3, and scanning time of 45 minutes, the simulated measuremened dose distribution would have a gamma passing rate greater than 97%. MAGIC exhibited similar performance while Fricke gel was inferior due to much higher noise. Conclusions: The simulation results demonstrated that it may be feasible to use MAGIC and BANG gels for 3D dose verification using ViewRay low-field on-board MRI scanner.

60 APPLIED LIFE SCIENCES↗

Low-noise, radiation tolerant SiCpms

Over the last 10 years, our R&D effort has resulted in a steady progress on improving Geiger detector array technology performance, verifying their reliability and developing three cell layout libraries containing more than 2200 primitive cells for Si and SiC Geiger based single-photon detectors and silicon ROIC array fabrication. Awards from DOE, NASA and DOD, as wells as commercial R&D orders supported much progress, relevant to this program. The expertise gained and the technologies developed or qualified during these programs provided the design database and expertise to carry out the development of this new SiC photomultiplier (SiCpm) technology, successful fabrication of SiCpm detectors, and evaluation of their radiation hardness. After irradiation with protons and neutrons at 1015cm-2 and 1014cm-2 respectively, SiCpms proved radiation hardness, exceeding the expected radiation tolerance The defects induced by irradiation were mainly point defects. A new improved DLTS method (fDLTS – full wave DLTS) hardware and data processing software specific to investigating radiation damage in SiC was developed. Further work is needed to better characterize and control defects induced by charged particles. We recommend further funding of radiation hardened technology development and validation; qualification of device-specific characterization methods like f-DLTS, development of more methods to evaluate defects in SiC, more active involvement of the national labs in evaluating the SiCpm devices, and DOE support of technology transfer to a qualified foundry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1985 Annual Conference on Nuclear and Space Radiation Effects, 22nd, Monterey, CA, July 22-24, 1985, Proceedings

Basic mechanisms of radiation effects in structures and materials are discussed, taking into account the time dependence of interface state production, process dependent build-up of interface states in irradiated N-channel MOSFETs, bias annealing of radiation and bias induced positive charges in n- and p-type MOS capacitors, hole removal in thin-gate MOSFETs by tunneling, and activation energies of oxide charge recovery in SOS or SOI structures after an ionizing pulse. Other topics investigated are related to radiation effects in devices, radiation effects in integrated circuits, spacecraft charging and space radiation effects, single-event phenomena, hardness assurance and radiation sources, SGEMP/IEMP phenomena, EMP phenomena, and dosimetry and energy-dependent effects. Attention is given to a model of the plasma wake generated by a large object, gate charge collection and induced drain current in GaAs FETs, simulation of charge collection in a multilayer device, and time dependent dose enhancement effects on integrated circuit transient response mechanisms.

Jones, C. W.↗