Detection of melting by X-ray imaging at high pressure

The occurrence of partial melting at elevated pressure and temperature is documented in real time through measurement of volume strain induced by a fixed temperature change. Here we present the methodology for measuring volume strains to one part in 10{sup −4} for mm{sup 3} sized samples in situ as a function of time during a step in temperature. By calibrating the system for sample thermal expansion at temperatures lower than the solidus, the onset of melting can be detected when the melting volume increase is of comparable size to the thermal expansion induced volume change. We illustrate this technique with a peridotite sample at 1.5 GPa during partial melting. The Re capsule is imaged with a CCD camera at 20 frames/s. Temperature steps of 100 K induce volume strains that triple with melting. The analysis relies on image comparison for strain determination and the thermal inertia of the sample is clearly seen in the time history of the volume strain. Coupled with a thermodynamic model of the melting, we infer that we identify melting with 2 vol.% melting.

36 MATERIALS SCIENCE↗

Source localization for neutron imaging systems using convolutional neural networks

The nuclear imaging system at the National Ignition Facility (NIF) is a crucial diagnostic for determining the geometry of inertial confinement fusion implosions. The geometry is reconstructed from a neutron aperture image via a set of reconstruction algorithms using an iterative Bayesian inference approach. An important step in these reconstruction algorithms is finding the fusion source location within the camera field-of-view. Currently, source localization is achieved via an iterative optimization algorithm. In this paper, we introduce a machine learning approach for source localization. Specifically, we train a convolutional neural network to predict source locations given a neutron aperture image. We show that this approach decreases computation time by several orders of magnitude compared to the current optimization-based source localization while achieving similar accuracy on both synthetic data and a collection of recent NIF deuterium–tritium shots.

47 OTHER INSTRUMENTATION↗

Pinhole Cameras for NSLS-II Storage Ring

The pinhole camera has been a workhorse for measuring electron beam size on the storage ring-based light sources. The NSLS-II storage ring will utilize diffraction limited in vertical plane electron beam in order to achieve unprecedented brightness. The goal of the study described in this paper is to define the resolution of the imaging systems and to optimize the beamline design. Initially, the storage ring will have only three damping wigglers installed, and first commissioning will be performed without the damping wigglers. In the final configuration, up to eight damping wigglers are planned.

36 MATERIALS SCIENCE↗

Source localization for neutron imaging systems using convolutional neural networks

The nuclear imaging system at the National Ignition Facility (NIF) is a crucial diagnostic for determining the geometry of inertial confinement fusion implosions. The geometry is reconstructed from a neutron aperture image via a set of reconstruction algorithms using an iterative Bayesian inference approach. An important step in these reconstruction algorithms is finding the fusion source location within the camera field-of-view. Currently, source localization is achieved via an iterative optimization algorithm. In this paper, we introduce a machine learning approach for source localization. Specifically, we train a convolutional neural network to predict source locations given a neutron aperture image. We show that this approach decreases computation time by several orders of magnitude compared to the current optimization-based source localization while achieving similar accuracy on both synthetic data and a collection of recent NIF deuterium–tritium shots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vegetation Warming Experiment: Chamber and ambient plot digital camera imagery for vegetation phenology, Utqiagvik (Barrow), Alaska, 2018

Time lapse photography of experimental plots within five warming chambers (ZPWs) and paired control plots located on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska. Images were recorded from 17 June to 24 September, 2018 to capture vegetation dynamics during the growing season. Vegetation phenology, including green up and senescence were captured. Images are *.jpg files recorded daily at 30 minute intervals, from 11:00 - 14:30 Alaska daylight time (AKDT, UTC-8), using Wingscapes TimelapseCam cameras. The target species was Arctagrostis latifolia. Additional information in *.pdf and *.csv files. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Integration of conductivity probe with optical and x-ray imaging systems for local air–water two-phase flow measurement

Various techniques have been developed in the past to measure different parameters in two-phase flow. Among them, the multi-sensor conductivity probe is one of the most commonly used techniques because of its good overall performance. Recently, more advanced techniques such as high speed optical imaging and fast X-ray densitometry become mature and easily accessible. The main objective of this work is to compare and integrate these different techniques, to achieve a more accurate and complete measurement of two-phase flow. In this study, a double-sensor conductivity probe is used to measure the local time-averaged parameters along the radial direction of a 2.54 cm ID round pipe. An X-ray densitometry system is used to measure the chordal averaged void fraction and gas velocity. A high speed camera system is employed to provide the visualization of the two-phase flow structure and obtain the line-averaged gas velocity. The unique advantages and main uncertainties of these three techniques are analyzed by considering their measuring principles and possible issues in practical measurements. From this, a method is developed to integrate the data obtained by the optical and X-ray systems into the probe signal processing. Finally, a better accuracy could be achieved using this method for various local two-phase flow parameters including void fraction, bubble velocity and superficial gas velocity, compared to the original probe measurements.

42 ENGINEERING↗

In situ strain and temperature measurement and modelling during arc welding

In this study, experiments and numerical models were applied to investigate the thermal and mechanical behaviours of materials adjacent to the weld pool during arc welding. In the experiment, a new high temperature strain measurement technique based on digital image correlation (DIC) was developed and applied to measure the in situ strain evolution. In contrast to the conventional DIC method that is vulnerable to the high temperature and intense arc light involved in fusion welding processes, the new technique utilised a special surface preparation method to produce high temperature sustaining speckle patterns required by the DIC algorithm as well as a unique optical illumination and filtering system to suppress the influence of the intense arc light. These efforts made it possible for the first time to measure in situ the strain field 1 mm away from the fusion line. The temperature evolution in the weld and the adjacent regions was simultaneously monitored by an infrared camera. Finally and additionally, a thermal–mechanical finite element model was applied to substantiate the experimental measurement.

36 MATERIALS SCIENCE↗

Electron cyclotron resonance ion source plasma characterization by X-ray spectroscopy and X-ray imaging

An experimental campaign aiming to investigate electron cyclotron resonance (ECR) plasma X-ray emission has been recently carried out at the ECRISs—Electron Cyclotron Resonance Ion Sources laboratory of Atomki based on a collaboration between the Debrecen and Catania ECR teams. In a first series, the X-ray spectroscopy was performed through silicon drift detectors and high purity germanium detectors, characterizing the volumetric plasma emission. The on-purpose developed collimation system was suitable for direct plasma density evaluation, performed “on-line” during beam extraction and charge state distribution characterization. A campaign for correlating the plasma density and temperature with the output charge states and the beam intensity for different pumping wave frequencies, different magnetic field profiles, and single-gas/gas-mixing configurations was carried out. The results reveal a surprisingly very good agreement between warm-electron density fluctuations, output beam currents, and the calculated electromagnetic modal density of the plasma chamber. A charge-coupled device camera coupled to a small pin-hole allowing X-ray imaging was installed and numerous X-ray photos were taken in order to study the peculiarities of the ECRIS plasma structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Installation of a fast framing visible camera on KSTAR

Visible camera technologies have made remarkable progress in recent years, and the fast camera has proven itself to be a capable imaging diagnostic in studies of specific fusion plasma issues such as the start-up physics, plasma wall interactions, edge-localized modes, and disruptions. For the purpose of favorable visible imaging, a fast framing camera has recently been installed on the Korea Superconducting Tokamak Advanced Research (KSTAR) device. The camera uses a complementary metal-oxide semiconductor detector with a maximum resolution of 1280x1024 at 1000 frames/s (fps) and a minimum resolution of 1280x16 at 64 kfps. A 2-m-long viewport having a novel optical rail system was installed on a tangential port to view the tokamak interior. The system is fully controlled from the main control room and protected by a shutter from deposits. To verify that the camera electronics are safe from the high magnetic field and its rapid time variation, possible influences are considered theoretically and experimentally. In this work, we present the design and installation of the fast camera system on the KSTAR device with discussions on the field variation effect issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SEARCH FOR THE OPTICAL COUNTERPART TO SGR 0418+5729

We report broadband Hubble Space Telescope imaging of the field of soft {gamma}-ray repeater SGR 0418+5729 with Advanced Camera for Surveys/Wide Field Channel and Wide Field Camera 3/IR. Observing in two wide filters, F606W and F110W, we find no counterpart within the positional error circle derived from Chandra observations, to limiting magnitudes m{sub F606W} > 28.6 and m{sub F110W} > 27.4 (Vega system), equivalent to reddening-corrected luminosity limits L{sub F606W} < 5 Multiplication-Sign 10{sup 28} and L{sub F110W} < 6 Multiplication-Sign 10{sup 28} erg s{sup -1} for a distance d = 2 kpc, at 3{sigma} confidence. This, in turn, imposes lower limits on the contemporaneous X-ray/optical flux ratio of {approx_equal}1100 and the X-ray/near-infrared flux ratio of {approx_equal}1000. We derive an upper limit on the temperature and/or size of any fall-back disk around the magnetar. We also compare the detection limits with observations of other magnetars.

79 ASTRONOMY AND ASTROPHYSICS↗

Methods and systems for detecting cancer

A technique for classifying lesions as malignant or benign is disclosed. The technique can include: cooling an area of skin including a lesion of a patient to initiate a warm-up process; receiving a temporal sequence of thermal images of the area of skin representing a thermal recovery of the area of skin, the temporal sequence of thermal images generated by an infrared camera; generating a temporal profile of the thermal recovery based on the temporal sequence of thermal images; analyzing temporal statistical properties of the temporal profile; determining a malignancy probability that the lesion is malignant based on an analysis of the temporal profile, wherein the determining includes extracting one or more statistical features based on continuous-time stochastic signals in the sequence of thermal images; and classifying the lesion based on the malignancy probability.

47 OTHER INSTRUMENTATION↗

Laser-induced radical generation and evolution to a self-sustaining flame

Images and emission spectra of sparks produced by laser-induced breakdown of methane and propane air mixtures were investigated with a high degree of spatial and temporal resolution. The laser-induced breakdown was generated by focusing a 532-nm nanosecond pulse from a Q-switched Nd:YAG laser. The data were collected using an intensified high-speed camera and a single/multi-fiber Cassegrain optics system coupled to an ICCD spectrometer. Emission spectra of OH{sup *}, CN{sup *}, CH{sup *}, and C{sup *}{sub 2} radicals were also collected using spectra boxes. The results provided information about the different stages of the laser-induced breakdown, with a specific focus on the transition from a flame kernel to a self-sustaining flame. The plasma shape and emission spectrum were very reproducible. The differences in the size of the flame kernel and the evolution of the radical emissions were analyzed for mixtures that fired or misfired. The impact of the level of radicals in the flame kernel was a critical parameter for the firing process, starting around 1 {mu}s after the laser-induced breakdown. The transition from plasma cooling to the classical chemical reactions in the combustion zone was analyzed. Even though the flame kernel size was directly linked to the spark energy, this was not a key parameter toward evolution to a self-sustaining flame. The Taylor blast wave theory was used to plot the location of the shock based on the evolution of the flame kernel size. The location was calculated using a laser-supported detonation model. A very good correlation was observed with the hot gas ignition process. Our results allowed us to obtain information about the process leading to firing or misfiring for similar environments, resulting in a better understanding of the laser breakdown phenomena and the means of utilizing this technique in an industrial context. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE SCHMIDT-KENNICUTT LAW OF MATCHED-AGE STAR-FORMING REGIONS; Pa{alpha} OBSERVATIONS OF THE EARLY-PHASE INTERACTING GALAXY TAFFY I

In order to test a recent hypothesis that the dispersion in the Schmidt-Kennicutt law arises from variations in the evolutionary stage of star-forming molecular clouds, we compared molecular gas and recent star formation in an early-phase merger galaxy pair, Taffy I (UGC 12915/UGC 12914, VV 254) which went through a direct collision 20 Myr ago and whose star-forming regions are expected to have similar ages. Narrowband Pa{alpha} image is obtained using the ANIR near-infrared camera on the mini-TAO 1 m telescope. The image enables us to derive accurate star formation rates within the galaxy directly. The total star formation rate, 22.2 M{sub Sun} yr{sup -1}, was found to be much higher than previous estimates. Ages of individual star-forming blobs estimated from equivalent widths indicate that most star-forming regions are {approx}7 Myr old, except for a giant H II region at the bridge which is much younger. Comparison between star formation rates and molecular gas masses for the regions with the same age exhibits a surprisingly tight correlation, a slope of unity, and star formation efficiencies comparable to those of starburst galaxies. These results suggest that Taffy I has just evolved into a starburst system after the collision, and the star-forming sites are at a similar stage in their evolution from natal molecular clouds except for the bridge region. The tight Schmidt-Kennicutt law supports the scenario that dispersion in the star formation law is in large part due to differences in evolutionary stage of star-forming regions.

79 ASTRONOMY AND ASTROPHYSICS↗

A WIDE-FIELD SURVEY OF THE ORION NEBULA CLUSTER IN THE NEAR-INFRARED

We present J, H, and K {sub S} photometry of the Orion Nebula Cluster (ONC) obtained at the CTIO/Blanco 4 m telescope at Cerro Tololo with the Infrared Side Port Imager camera. From the observations we have assembled a catalog of about {approx}7800 sources distributed over an area of approximately 30' x 40', the largest of any survey deeper than the Two Micron All Sky Survey (2MASS) in this region. The catalog provides absolute coordinates accurate to about 0.15 arcsec and 3{sigma} photometry in the 2MASS system, enough to detect planetary size objects 1 Myr old under A{sub V} {approx_equal} 10 mag of extinction at the distance of the Orion Nebula. We present a preliminary analysis of the catalog, done by comparing the (J-H, H-K {sub S} ) color-color diagram, the (H, J-H) and (K {sub S} , H-K {sub S} ) color-magnitude diagrams, and the J H K {sub S} luminosity functions (LFs) of three regions at an increasing projected distance from the Trapezium. Sources in the inner region typically show IR colors compatible with reddened T Tauri stars, whereas the outer fields are dominated by field stars seen through an amount of extinction which decreases with the distance from the center. The color-magnitude diagrams make it possible to clearly distinguish between the main ONC population, spread across the full field, and background sources. The LFs of the inner region, corrected for completeness, remain relatively flat in the substellar regime regardless of the strategy adopted to remove background contamination.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-A-BRD-06: In Vivo Cherenkov Video Imaging to Verify Whole Breast Irradiation Treatment

Purpose: To show in vivo video imaging of Cherenkov emission (Cherenkoscopy) can be acquired in the clinical treatment room without affecting the normal process of external beam radiation therapy (EBRT). Applications of Cherenkoscopy, such as patient positioning, movement tracking, treatment monitoring and superficial dose estimation, were examined. Methods: In a phase 1 clinical trial, including 12 patients undergoing post-lumpectomy whole breast irradiation, Cherenkov emission was imaged with a time-gated ICCD camera synchronized to the radiation pulses, during 10 fractions of the treatment. Images from different treatment days were compared by calculating the 2-D correlations corresponding to the averaged image. An edge detection algorithm was utilized to highlight biological features, such as the blood vessels. Superficial dose deposited at the sampling depth were derived from the Eclipse treatment planning system (TPS) and compared with the Cherenkov images. Skin reactions were graded weekly according to the Common Toxicity Criteria and digital photographs were obtained for comparison. Results: Real time (fps = 4.8) imaging of Cherenkov emission was feasible and feasibility tests indicated that it could be improved to video rate (fps = 30) with system improvements. Dynamic field changes due to fast MLC motion were imaged in real time. The average 2-D correlation was about 0.99, suggesting the stability of this imaging technique and repeatability of patient positioning was outstanding. Edge enhanced images of blood vessels were observed, and could serve as unique biological markers for patient positioning and movement tracking (breathing). Small discrepancies exists between the Cherenkov images and the superficial dose predicted from the TPS but the former agreed better with actual skin reactions than did the latter. Conclusion: Real time Cherenkoscopy imaging during EBRT is a novel imaging tool that could be utilized for patient positioning, movement tracking, treatment monitoring, superficial dose and skin reaction estimation and prediction.

60 APPLIED LIFE SCIENCES↗

ePix100 camera: Use and applications at LCLS

The ePix100 x-ray camera is a new system designed and built at SLAC for experiments at the Linac Coherent Light Source (LCLS). The camera is the first member of a family of detectors built around a single hardware and software platform, supporting a variety of front-end chips. With a readout speed of 120 Hz, matching the LCLS repetition rate, a noise lower than 80 e-rms and pixels of 50 µm × 50 µm, this camera offers a viable alternative to fast readout, direct conversion, scientific CCDs in imaging mode. The detector, designed for applications such as X-ray Photon Correlation Spectroscopy (XPCS) and wavelength dispersive X-ray Emission Spectroscopy (XES) in the energy range from 2 to 10 keV and above, comprises up to 0.5 Mpixels in a very compact form factor. In this paper, we report the performance of the camera during its first use at LCLS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real time capable infrared thermography for ASDEX Upgrade

Infrared (IR) thermography is widely used in fusion research to study power exhaust and incident heat load onto the plasma facing components. Due to the short pulse duration of today’s fusion experiments, IR systems have mostly been designed for off-line data analysis. For future long pulse devices (e.g., Wendelstein 7-X, ITER), a real time evaluation of the target temperature and heat flux is mandatory. This paper shows the development of a real time capable IR system for ASDEX Upgrade. A compact IR camera has been designed incorporating the necessary magnetic and electric shielding for the detector, cooler assembly. The camera communication is based on the Camera Link industry standard. The data acquisition hardware is based on National Instruments hardware, consisting of a PXIe chassis inside and a fibre optical connected industry computer outside the torus hall. Image processing and data evaluation are performed using real time LabVIEW.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemical and physical transformations of carbon-based nanomaterials observed by liquid phase transmission electron microscopy

This article addresses recent advances in liquid phase transmission electron microscopy (LPTEM) for studying nanoscale synthetic processes of carbon-based materials that are independent of the electron beam—those driven by nonradiolytic chemical or thermal reactions. In particular, we focus on chemical/physical formations and the assembly of nanostructures composed of organic monomers/polymers, peptides/DNA, and biominerals. The synthesis of carbon-based nanomaterials generally only occurs at specific conditions, which cannot be mimicked by aqueous solution radiolysis. Carbon-based structures themselves are also acutely sensitive to the damaging effects of the irradiating beam, which make studying their synthesis using LPTEM a unique challenge that is possible when beam effects can be quantifi ed and mitigated. With new direct sensing, high frame rate cameras, and advances in liquid-cell holder designs, combined with a growing understanding of irradiation effects and proper experimental controls, microscopists have been able to make strides in observing traditionally problematic carbon-based materials under conditions where synthesis can be controlled, and imaged free from beam effects, or with beam effects quantified and accounted for. These materials systems and LPTEM experimental techniques are discussed, focusing on nonradiolytic chemical and physical transformations relevant to materials synthesis.

Parent, Lucas R.↗