Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Mapping of Benthic Habitats at Marine Renewable Energy Sites Using Multibeam Echosounder and Sediment Profile Imaging Technologies

Objectives/Scope: The goal of this work was to develop a consistent and semi-automated seafloor survey method for generating high-resolution, benthic habitat maps for environmental assessments and monitoring of marine renewable energy sites. Sediment profile and plan view imaging (SPI/PV) technology was combined with multibeam bathymetry and acoustic backscatter methods to demonstrate a rapid, cost-effective benthic mapping protocol. A key technical innovation of this project was the development of an image processing platform that automatically measures key features from the images. Methods: Multibeam echosounder (MBES) acoustic and SPI/PV surveys were conducted at three coastal areas off the U.S. west coast, including the PacWave South energy test site off of Newport, Oregon. Point data on physical and biological sediment conditions obtained from the SPI/PV imagery were used to efficiently ground-truth the high-resolution MBES bathymetry and backscatter mosaics. The SPI camera is an optical corer that obtains an undisturbed 21 by 15 cm, high-resolution, cross-sectional image of the sediment–water interface and upper sediment column. The plan view camera attached to the SPI camera frame captures a downward looking view of the seabed immediately before the SPI image is obtained. As part of this project, we developed a computer vision image processing platform (iSPI) that uses deep convolutional neural networks and other approaches to automatically identify and measure key features in the images, such as grain size and surface relief. Results: Detailed benthic habitat maps were generated using this mapping approach for three different marine settings. The sites mapped included a silt-dominated embayment; a sloping, nearshore, transitional very fine to coarse sand bottom; and a medium, sand-dominated continental shelf marine energy test site. In each case, acoustic and imaging surveys were completed in less than week, and detailed benthic habitat maps were generated within 60 days. The results were placed within the Coastal and Marine Ecological Classification Standard (CMECS) habitat mapping framework, and various combinations of the bathymetry, backscatter, and SPI and PV data were used to generate CMECS component maps. Novel Information: This project developed and demonstrated a repeatable and cost-effective approach for efficiently mapping benthic habitat conditions over broad areas of the seafloor by combining state-of-the-art acoustic and imaging techniques. The primary survey tools used in this project have been used previously in both the offshore renewable (wind) and oil and gas sectors to map and monitor benthic environments. This project’s innovations include 1) the focused use of high-resolution SPI/PV imagery to ground-truth acoustic mosaics, and 2) the development of a computer automated image analysis processing tool that both streamlines and standardizes the generation of data from the imagery and makes the data extraction process more cost-effective and repeatable.

13 HYDRO ENERGY↗

Compatibility of a Diffractive Pupil and Coronagraphic Imaging

Detection and characterization of exo-earths require direct-imaging techniques that can deliver contrast ratios of 10(exp 10) at 100 milliarc-seconds or smaller angular separation. At the same time, astrometric data is required to measure planet masses and can help detect planets and constrain their orbital parameters. To minimize costs, a single space mission can be designed using a high efficiency coronograph to perform direct imaging and a diffractive pupil to calibrate wide-field distortions to enable high precision astrometric measurements. This paper reports the testing of a diffractive pupil on the high-contrast test bed at the NASA Ames Research Center to assess the compatibility of using a diffractive pupil with coronographic imaging systems. No diffractive contamination was found within our detectability limit of 2x10(exp -7) contrast outside a region of 12lambda/D and 2.5x10(exp -6) within a region spanning from 2 to 12lambda/D. Morphology of the image features suggests that no contamination exists even beyond the detectability limit specified or at smaller working angles. In the case that diffractive contamination is found beyond these stated levels, active wavefront control would be able to mitigate its intensity to 10(exp -7) or better contrast.

Bendek, Eduardo↗

Bent Laue crystal anatomy: new insights into focusing and energy-dispersion properties

X-ray Laue-type monochromators are common and essential optical components at many high-power X-ray facilities, e.g. synchrotron facilities. The X-ray optics of bent Laue crystals is a well developed area. An incident X-ray beam penetrating a bent Laue crystal will result in a diffracted beam with different angles and energies. There is a need for a way of organizing the rays that allows one to sort out the energy and spatial properties of the diffracted beam. The present work introduces a new approach for describing the general behaviour of bent Laue crystals from a ray-tracing point of view. This quasi-monochromatic beam approach provides an intuitive view of bent-crystal diffraction and leads to deeper understanding. It explains the energy and spatial properties of common and special cases of bent Laue optics, predicts phenomena that can improve energy-dispersion-related X-ray imaging techniques and provides a theoretical framework that makes ray-tracing simulation easier to realize.

36 MATERIALS SCIENCE↗

Stereo image visualization of numerically simulated turbulence

Stereo imaging techniques are used in the current study to analyze the results of a direct Navier-Stokes simulation of a turbulent boundary layer. Coherent structures embedded within the unsteady, highly three-dimensional turbulent flow fields are significantly enhanced through the use of stereo computer graphic renderings. In the paper, the geometrical foundations of two different methods for generating stereo images are reviewed. Sufficient detail is provided to enable readers to code stereo display algorithms from scratch. The effects of varying the geometric parameters of the stereo algorithm are demonstrated. Sample image pairs from animations of the turbulence numerical simulation are presented in color. Stereo imagery, especially when used with time-evolving data, provides new insight into the physical processes responsible for the generation an maintenance of turbulence within boundary layers.

Robinson, Stephen K.↗

Isothermal oxidation of zirconium using steam

Oxidation of zirconium and its alloys under any atmosphere is generally characterised by a protective and non-protective stage. During the protective stage, the kinetics of oxidation are quasi-parabolic, while the oxide scale formed on the surface of the metal is black, compact, and protective in nature. For the non-protective stage, the oxidation rate becomes linear, while the protective oxide film turns into a deteriorated white scale. Breakaway is known as the transition point from protective to non-protective stage. The actual mechanism leading to breakaway of zirconium is still a matter of controversy, however some of the most common factors affecting breakaway are the following: - Impurities on the metal (Carbon, Oxygen, Nitrogen); - Oxidizing atmosphere (Presence of H{sub 2}O (g) or N{sub 2} (g)); - Sample preparation (Chemically etched or polished); - Temperature (LWR, LOCA). This research investigates the effect of temperature on 'breakaway' when zirconium is oxidized isothermally in steam for 60 min at 800 and 900 deg. C using thermogravimetric and optical microscopic imaging techniques. 1. Steam isothermal oxidations were performed on zirconium at 800 and 900 deg. C using a Thermogravimetric Analyzer (TGA). 2. Log-log plots of mass gain vs time were obtained from thermogravimetric results to calculate the reaction orders (n) and reaction rate constants (K) during oxidation. 3. Results of the kinetics of reaction were correlated with optical microscopic images form Light Microscope (LM) and Scanning Electron Microscope (SEM). Breakaway depends very strongly on temperature. At 800 deg. C, the weight gain followed a cubic-parabolic behaviour with evidence of a protective oxide film. On the other hand, oxidation at 900 deg. C showed signs of breakaway since the oxide film was cracked and oxidation rate was almost linear throughout the reaction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Merging single-shot XFEL diffraction data from inorganic nanoparticles: a new approach to size and orientation determination

X-ray free-electron lasers (XFELs) provide new opportunities for structure determination of biomolecules, viruses and nanomaterials. With unprecedented peak brilliance and ultra-short pulse duration, XFELs can tolerate higher X-ray doses by exploiting the femtosecond-scale exposure time, and can thus go beyond the resolution limits achieved with conventional X-ray diffraction imaging techniques. Using XFELs, it is possible to collect scattering information from single particles at high resolution, however particle heterogeneity and unknown orientations complicate data merging in three-dimensional space. Using the Linac Coherent Light Source (LCLS), synthetic inorganic nanocrystals with a core–shell architecture were used as a model system for proof-of-principle coherent diffractive single-particle imaging experiments. To deal with the heterogeneity of the core–shell particles, new computational methods have been developed to extract the particle size and orientation from the scattering data to assist data merging. The size distribution agrees with that obtained by electron microscopy and the merged data support a model with a core–shell architecture.

36 MATERIALS SCIENCE↗

Enhancing NDE Reliability for Grade 91 Steel Welds: Ultrasonic Imaging and Microstructural Correlations

Ensuring the integrity of Grade 91 (9Cr-1Mo-V) steel welds is vital for the safe and reliable operation of fossil fuel–fired and nuclear power plants. Here, this study applies an imaging technique for the ultrasonic characterization of two Grade 91 steel welds created with cold metal transfer and flux-cored arc welding processes. Ultrasonic immersion testing in the through-transmission configuration was employed to generate shear waves, which helped identify the weld metal, heat-affected zone, and base metal regions. These weld microstructures were also correlated to their ultrasonic images using metallography, ultrasonic amplitude, hardness measurements, and grain size. The findings from this study can assist practitioners in developing new nondestructive evaluation technologies, improving the inspection reliability of creep strength–enhanced ferritic steel welds by potentially identifying weld microstructure regions susceptible to creep-type failures.

Grade 91 steel↗

Identification of lithium hydride and its hydrolysis products with neutron imaging

In this study, lithium hydride (LiH) and its hydrolysis products were investigated non-destructively with neutron radiography and neutron computed tomography. Relative neutron transmission intensities (I/I 0 ) were measured for LiOH, Li 2 O and LiH, and their linear attenuation coefficients calculated from this data. We show that 7 Li is necessary for creating large differences in I/I 0 for facile identification of these compounds. The thermal decomposition of LiOH to Li 2 O was also observed with neutron radiography. Computed tomography shows that the samples were fairly homogeneous, with very few macroscopic defects. Lastly, the results shown here demonstrate the feasibility of observing LiH hydrolysis with neutron imaging techniques in real time.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The footprints of visual attention in the Posner cueing paradigm revealed by classification images

In the Posner cueing paradigm, observers' performance in detecting a target is typically better in trials in which the target is present at the cued location than in trials in which the target appears at the uncued location. This effect can be explained in terms of a Bayesian observer where visual attention simply weights the information differently at the cued (attended) and uncued (unattended) locations without a change in the quality of processing at each location. Alternatively, it could also be explained in terms of visual attention changing the shape of the perceptual filter at the cued location. In this study, we use the classification image technique to compare the human perceptual filters at the cued and uncued locations in a contrast discrimination task. We did not find statistically significant differences between the shapes of the inferred perceptual filters across the two locations, nor did the observed differences account for the measured cueing effects in human observers. Instead, we found a difference in the magnitude of the classification images, supporting the idea that visual attention changes the weighting of information at the cued and uncued location, but does not change the quality of processing at each individual location.

Non-NASA Center↗

Image Correlation Pattern Optimization for Micro-Scale In-Situ Strain Measurements

The accuracy and precision of digital image correlation (DIC) is a function of three primary ingredients: image acquisition, image analysis, and the subject of the image. Development of the first two (i.e. image acquisition techniques and image correlation algorithms) has led to widespread use of DIC; however, fewer developments have been focused on the third ingredient. Typically, subjects of DIC images are mechanical specimens with either a natural surface pattern or a pattern applied to the surface. Research in the area of DIC patterns has primarily been aimed at identifying which surface patterns are best suited for DIC, by comparing patterns to each other. Because the easiest and most widespread methods of applying patterns have a high degree of randomness associated with them (e.g., airbrush, spray paint, particle decoration, etc.), less effort has been spent on exact construction of ideal patterns. With the development of patterning techniques such as microstamping and lithography, patterns can be applied to a specimen pixel by pixel from a patterned image. In these cases, especially because the patterns are reused many times, an optimal pattern is sought such that error introduced into DIC from the pattern is minimized. DIC consists of tracking the motion of an array of nodes from a reference image to a deformed image. Every pixel in the images has an associated intensity (grayscale) value, with discretization depending on the bit depth of the image. Because individual pixel matching by intensity value yields a non-unique scale-dependent problem, subsets around each node are used for identification. A correlation criteria is used to find the best match of a particular subset of a reference image within a deformed image. The reader is referred to references for enumerations of typical correlation criteria. As illustrated by Schreier and Sutton and Lu and Cary systematic errors can be introduced by representing the underlying deformation with under-matched shape functions. An important implication, as discussed by Sutton et al., is that in the presence of highly localized deformations (e.g., crack fronts), error can be reduced by minimizing the subset size. In other words, smaller subsets allow the more accurate resolution of localized deformations. Contrarily, the choice of optimal subset size has been widely studied and a general consensus is that larger subsets with more information content are less prone to random error. Thus, an optimal subset size balances the systematic error from under matched deformations with random error from measurement noise. The alternative approach pursued in the current work is to choose a small subset size and optimize the information content within (i.e., optimizing an applied DIC pattern), rather than finding an optimal subset size. In the literature, many pattern quality metrics have been proposed, e.g., sum of square intensity gradient (SSSIG), mean subset fluctuation, gray level co-occurrence, autocorrelation-based metrics, and speckle-based metrics. The majority of these metrics were developed to quantify the quality of common pseudo-random patterns after they have been applied, and were not created with the intent of pattern generation. As such, it is found that none of the metrics examined in this study are fit to be the objective function of a pattern generation optimization. In some cases, such as with speckle-based metrics, application to pixel by pixel patterns is ill-conditioned and requires somewhat arbitrary extensions. In other cases, such as with the SSSIG, it is shown that trivial solutions exist for the optimum of the metric which are ill-suited for DIC (such as a checkerboard pattern). In the current work, a multi-metric optimization method is proposed whereby quality is viewed as a combination of individual quality metrics. Specifically, SSSIG and two auto-correlation metrics are used which have generally competitive objectives. Thus, each metric could be viewed as a constraint imposed upon the others, thereby precluding the achievement of their trivial solutions. In this way, optimization produces a pattern which balances the benefits of multiple quality metrics. The resulting pattern, along with randomly generated patterns, is subjected to numerical deformations and analyzed with DIC software. The optimal pattern is shown to outperform randomly generated patterns.

Bomarito, G. F.↗

Design of optimal collimation for dedicated molecular breast imaging systems

Molecular breast imaging (MBI) is a functional imaging technique that uses specialized small field-of-view gamma cameras to detect the preferential uptake of a radiotracer in breast lesions. MBI has potential to be a useful adjunct method to screening mammography for the detection of occult breast cancer. However, a current limitation of MBI is the high radiation dose (a factor of 7-10 times that of screening mammography) associated with current technology. The purpose of this study was to optimize the gamma camera collimation with the aim of improving sensitivity while retaining adequate resolution for the detection of sub-10-mm lesions. Square-hole collimators with holes matched to the pixilated cadmium zinc telluride detector elements of the MBI system were designed. Data from MBI patient studies and parameters of existing dual-head MBI systems were used to guide the range of desired collimator resolutions, source-to-collimator distances, pixel sizes, and collimator materials that were examined. General equations describing collimator performance for a conventional gamma camera were used in the design process along with several important adjustments to account for the specialized imaging geometry of the MBI system. Both theoretical calculations and a Monte Carlo model were used to measure the geometric efficiency (or sensitivity) and resolution of each designed collimator. Results showed that through optimal collimation, collimator sensitivity could be improved by factors of 1.5-3.2, while maintaining a collimator resolution of either {<=}5 or {<=}7.5 mm at a distance of 3 cm from the collimator face. These gains in collimator sensitivity permit an inversely proportional drop in the required dose to perform MBI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase contrast tomography of the mouse cochlea at microfocus x-ray sources

We present phase contrast x-ray tomography of functional soft tissue within the bony cochlear capsule of mice, carried out at laboratory microfocus sources with well-matched source, detector, geometry, and reconstruction algorithms at spatial resolutions down to 2 μm. Contrast, data quality and resolution enable the visualization of thin membranes and nerve fibers as well as automated segmentation of surrounding bone. By complementing synchrotron radiation imaging techniques, a broad range of biomedical applications becomes possible as demonstrated for optogenetic cochlear implant research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser speckle contrast imaging of cerebral autoregulation in rats at a macro- and microcirculation level

Using the method of laser speckle imaging for the simultaneous study of macro- and microcirculation in cerebral vessels of healthy rats, we show that the mechanisms underlying cerebral autoregulation depend on the initial condition of the organism and the sex of individual animals. The pharmacological dose-dependent stimulation of the peripheral arterial pressure increase is not accompanied by the cerebral circulation responses of analogous intensity, but manifests itself as 'compensating' reactions, namely, the redistribution of the blood flow at the level of macro- (in females) and microcirculation (in females and males). The obtained results extend our understanding of the capabilities of laser speckle imaging technique in neurophysiological studies of reserve abilities of cerebral circulation autoregulation under the conditions of hypertensive status formation. (laser biophotonics)

60 APPLIED LIFE SCIENCES↗

Status of the Whipple Observatory Cerenkov air shower imaging telescope array

Recently the power of the Cerenkov imaging technique in Very High Energy gamma-ray astronomy was demonstrated by the detection of the Crab nebula at high statistical significance. In order to further develop this technique to allow the detection of weaker or more distant sources a second 10 m class reflector was constructed about 120 m from the original instrument. The addition of the second reflector will allow both a reduction in the energy threshold and an improvement in the rejection of the hadronic background. The design and construction of the second reflector, Gamma Ray Astrophysics New Imaging TElescope (GRANITE) is described.

Akerlof, C. W.↗

Simulation of Detecting Damage in Composite Stiffened Panel Using Lamb Waves

Lamb wave damage detection in a composite stiffened panel is simulated by performing explicit transient dynamic finite element analyses and using signal imaging techniques. This virtual test process does not need to use real structures, actuators/sensors, or laboratory equipment. Quasi-isotropic laminates are used for the stiffened panels. Two types of damage are studied. One type is a damage in the skin bay and the other type is a debond between the stiffener flange and the skin. Innovative approaches for identifying the damage location and imaging the damage were developed. The damage location is identified by finding the intersection of the damage locus and the path of the time reversal wave packet re-emitted from the sensor nodes. The damage locus is a circle that envelops the potential damage locations. Its center is at the actuator location and its radius is computed by multiplying the group velocity by the time of flight to damage. To create a damage image for estimating the size of damage, a group of nodes in the neighborhood of the damage location is identified for applying an image condition. The image condition, computed at a finite element node, is the zero-lag cross-correlation (ZLCC) of the time-reversed incident wave signal and the time reversal wave signal from the sensor nodes. This damage imaging process is computationally efficient since only the ZLCC values of a small amount of nodes in the neighborhood of the identified damage location are computed instead of those of the full model.

Wang, John T.↗

The Diamond Beamline I13L for Imaging and Coherence

I13L is the first long beamline at Diamond dedicated to imaging and coherence. Two independent branches will operate in the energy range of 6-30 keV with spatial resolution on the micro- to nano-lengthscale. The Imaging branch is dedicated to imaging and tomography with In-line phase contrast and full-field microscopy on the micron to nano-length scale. Ultimate resolution will be achieved on the Coherence branch at I13L with imaging techniques in the reciprocal space. The experimental stations will be located about 250 m from the source, taking advantage of the coherence properties of the source. The beamline has some outstanding features such as the mini-beta layout of the storage ring's straight section. The optical layout is optimized for beam stability and high optical quality to preserve the coherent radiation. In the experimental stations several methods will be available, starting for the first user with in-line phase contrast imaging on the imaging branch and Coherent X-ray Diffraction (CXRD) on the coherence branch.

43 PARTICLE ACCELERATORS↗

Low irradiance multiphoton imaging with alloyed lanthanide nanocrystals

Abstract Multiphoton imaging techniques that convert low-energy excitation to higher energy emission are widely used to improve signal over background, reduce scatter, and limit photodamage. Lanthanide-doped upconverting nanoparticles (UCNPs) are among the most efficient multiphoton probes, but even UCNPs with optimized lanthanide dopant levels require laser intensities that may be problematic. Here, we develop protein-sized, alloyed UCNPs (aUCNPs) that can be imaged individually at laser intensities >300-fold lower than needed for comparably sized doped UCNPs. Using single UCNP characterization and kinetic modeling, we find that addition of inert shells changes optimal lanthanide content from Yb 3+ , Er 3+ -doped NaYF 4 nanocrystals to fully alloyed compositions. At high levels, emitter Er 3+ ions can adopt a second role to enhance aUCNP absorption cross-section by desaturating sensitizer Yb 3+ or by absorbing photons directly. Core/shell aUCNPs 12 nm in total diameter can be imaged through deep tissue in live mice using a laser intensity of 0.1 W cm −2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Super-resolving microscopy images of Li-ion electrodes for fine-feature quantification using generative adversarial networks

Abstract For a deeper understanding of the functional behavior of energy materials, it is necessary to investigate their microstructure, e.g., via imaging techniques like scanning electron microscopy (SEM). However, active materials are often heterogeneous, necessitating quantification of features over large volumes to achieve representativity which often requires reduced resolution for large fields of view. Cracks within Li-ion electrode particles are an example of fine features, representative quantification of which requires large volumes of tens of particles. To overcome the trade-off between the imaged volume of the material and the resolution achieved, we deploy generative adversarial networks (GAN), namely SRGANs, to super-resolve SEM images of cracked cathode materials. A quantitative analysis indicates that SRGANs outperform various other networks for crack detection within aged cathode particles. This makes GANs viable for performing super-resolution on microscopy images for mitigating the trade-off between resolution and field of view, thus enabling representative quantification of fine features.

30 DIRECT ENERGY CONVERSION↗