Search NASA⌕ Search

SEARCH · Search NASA

Results for “Injection testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Time-Based CAN IDS Paper Results Code

Modern vehicles are complex cyber-physical systems made of hundreds of electronic control units (ECUs) that communicate over controller area networks (CANs). This inherited complexity has expanded the CAN attack surface which is vulnerable to message injection attacks. These injections change the overall timing characteristics of messages on the bus, and thus, to detect these malicious messages, time-based intrusion detection systems (IDSs) have been proposed. However, time-based IDSs are usually trained and tested on low-fidelity datasets with unrealistic, labeled attacks. This makes difficult the task of evaluating, comparing, and validating IDSs. Here we detail and benchmark four time-based IDSs against the newly published ROAD dataset, the first open CAN IDS dataset with real (non-simulated) stealthy attacks with physically verified effects. We found that methods that perform hypothesis testing by explicitly estimating message timing distributions have lower performance than methods that seek anomalies in a distribution related statistic. In particular, these “distribution-agnostic” based methods outperform “distribution-based” methods by at least 55% in area under the precision-recall curve (AUC-PR). Our results expand the body of knowledge of CAN time-based IDSs by providing details of these methods and reporting their results when tested on datasets with real advanced attacks. Finally, we develop an after-market plug-in detector using lightweight hardware, which can be used to deploy the best performing IDS method on nearly any vehicle.

Moriano, Pablo [Oak Ridge National Lab. (ORNL), Oa↗

In Situ Plasma Processing of Superconducting Cavities at JLab

Jefferson Lab has an ongoing R&D program in plasma processing which is close to going into production pro-cessing in the CEBAF accelerator. Plasma processing is a common technique for removing hydrocarbons from surfaces, which increases the work function and reduces the secondary emission coefficient[1]. The initial focus of the effort is processing C100 cavities by injecting RF power into the HOM coupler ports. The goal will be to improve the operational gradients and the energy margin of the CEBAF linacs by processing cryomodules in situ. Results from processing cryomodule in the cryomodule test bunker as well as vertical test results will be present-ed. This work will describe the systems and methods used at JLAB for processing cavities using an argon oxygen gas mixture. Before and after plasma processing results will also be presented.

Powers, T.↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 10: Controllability and Observability Analysis (Deliverable D7))

It is common to have less than full observability for distribution systems, as the number of available measurements are not sufficient. Considering increasing penetration of distributed energy resources (DERs), it is imperative to understand and control distribution systems better. Developed for the transmission system, the original numerical observability analysis methods were based on the canonical DC Power Flow (DC-PF) model. However, the DC-PF model is ill-suited for the distribution system in which line resistance to reactance (R/X) ratios can be near unity. In this report, we apply the non-iterative Observability Test (OT) and Observable Island Identification Procedure (OIIP) in to the gain matrix from the distribution system state estimator. Because sensors are few in distribution systems, pseudo-measurements based on historical load profiles and zero-injection virtual measurements are often employed to ensure observability. However, both the observability and the accuracy of the state estimates are uncertain when historical data is limited/unavailable.

42 ENGINEERING↗

IV Administered Gadodiamide Enters the Lumen of the Prostatic Glands: X-Ray Fluorescence Microscopy Examination of a Mouse Model

In our objective, we descibe how dynamic contrast-enhanced MRI (DCE-MRI) has become a standard component of multiparametric protocols for MRI examination of the prostate, and its use is incorporated into current guidelines for prostate MRI examination. Analysis of DCE-MRI data for the prostate is usually based on the distribution of gadolinium-based agents, such as gadodiamide, into two well-mixed compartments, and it assumes that gadodiamide does not enter into the glandular lumen. However, this assumption has not been directly tested. The purpose of this study was to use x-ray fluorescence microscopy (XFM) imaging in situ to measure the concentration of gadodiamide in the epithelia and lumens of the prostate of healthy mice after IV injection of the contrast agent. For our materials and methods, six C57Bl6 male mice (age, 28 weeks) were sacrificed 10 minutes after IV injection of gadodiamide (0.13 mmol/kg), and three mice were sacrificed after saline injection. Prostate tissue samples obtained from each mouse were harvested and frozen; 7-μm-thick slices were sectioned for XFM imaging, and adjacent 5-μm-thick slices were sectioned for H and E staining. Elemental concentrations were determined from XFM images. Our results show mean (± SD) baseline concentration of gadolinium of 0.01 ± 0.01 mM was determined from XFM measurements of prostatic tissue samples when no gadodiamide was administered, and it was used to determine the measurement error. When gadodiamide was added, the mean concentrations of gadolinium in the epithelia and lumens in 32 prostatic glands from six mice were 1.00 ± 0.13 and 0.36 ± 0.09 mM, respectively. In conclusion, our data suggest that IV administration of gadodiamide results in uptake of contrast agent by the glandular lumens of the mouse prostate. We were able to quantitatively determine gadodiamide distributions in mouse prostatic epithelia and lumens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinematic Evidence for an Embedded Planet in the IM Lupi Disk

Abstract We test the hypothesis that an embedded giant planet in the IM Lupi protostellar disk can produce velocity kinks seen in CO line observations as well as the spiral arms seen in scattered light and continuum emission. We inject planets into 3D hydrodynamics simulations of IM Lupi, generating synthetic observations using Monte Carlo radiative transfer. We find that an embedded planet of 2–3 M Jup can reproduce non-Keplerian velocity perturbations, or “kinks”, in the 12 CO J = 2–1 channel maps. Such a planet can also explain the spiral arms seen in 1.25 mm dust continuum emission and 1.6 μ m scattered-light images. We show that the wake of the planet can be traced in the observed peak velocity map, which appears to closely follow the morphology expected from our simulations and from analytic models of planet–disk interaction.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal Coordinated EV Charging with Reactive Power Support in Constrained Distribution Grids

Electric vehicle (EV) charging/discharging can take place in any P-Q quadrants, which means EVs could support reactive power to the grid while charging the battery. In controlled charging schemes, distribution system operator (DSO) coordinates with the charging of EV fleets to ensure grid’s operating constraints are not violated. In fact, this refers to DSO setting upper bounds on power limits for EV charging. In this work, we demonstrate that if EVs inject reactive power into the grid while charging, DSO could issue higher upper bounds on the active power limits for the EVs for the same set of grid constraints. We demonstrate the concept in an 33-node test feeder with 1,500 EVs. Case studies show that in constrained distribution grids in coordinated charging, average costs of EV charging could be reduced if the charging takes place in the fourth P-Q quadrant compared to charging with unity power factor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of CO 2 Detection Methods Tested in Shallow Groundwater Monitoring Wells at a Geological Sequestration Site

The geological storage of anthropogenic carbon dioxide (CO 2 ) is one method of reducing the amount of CO 2 released into the atmosphere. Monitoring programs typically determine baseline conditions in surface and near-surface environments before, during, and after CO 2 injection to evaluate if impacts related to injection have occurred. Because CO 2 concentrations in groundwater fluctuate naturally due to complex geochemical and geomicrobiologicalinteractions, a clear understanding of the baseline behavior of CO 2 in groundwater near injection sites is important. Numerous ways of measuring aqueous CO 2 in the field and lab are currently used, but most methods have significant shortcomings (e.g., are tedious, lengthy, have interferences, or have significant lag time before a result is determined). In this study, we examined the effectiveness of two novel CO 2 detection methods and their ability to rapidly detect CO2in shallow groundwater monitoring wells associated with the Illinois Basin –Decatur Project geological sequestration site. The CarboQC beverage carbonation meter was used to measure the concentration of CO 2 in water by monitoring temperature and pressure changes and calculating the PCO 2 from the ideal gas law. Additionally, a non-dispersive infrared (NDIR) CO< sub>2 sensor enclosed in a gas-permeable, water-impermeable membrane measured CO2by determining an equilibrium concentration. Results showed that the CarboQC method provided rapid (< 3 min) and repeatable results under field conditions within a measured concentration range of 15 –125 mg/L CO 2 . The NDIR sensor results correlated well (r 2 = 0.93) with the CarboQC data, but CO 2 equilibration required at least 15 minutes, making the method somewhat less desirable under field conditions. In contrast, NDIR-based sensors have a greater potential for long-term deployment. Both systems are adaptable to in-line groundwater sampling methods. Other specific advantages and disadvantages associated with the two approaches, and anomalies associated with specific samples, are discussed in greater detail in this poster.

54 ENVIRONMENTAL SCIENCES↗

A multi-species powder dropper for magnetic fusion applications

Here, we present a device for controlled injection of a variety of materials in powder form. The system implements four independent feeder units, arranged to share a single vertical drop tube. Each unit consists of a 80 ml reservoir, coupled to a horizontal linear trough, where a layer of powder is advanced by piezo-electric agitation at a speed proportional to the applied voltage, until it falls into a drop tube. The dropper has been tested with a number of impurities of low (B, BN, C), intermediate (Si, SiC), and high Z (Sn) and a variety of microscopic structures (flakes, spheres, rocks) and sizes (5-200 μm). For low Z materials, drop rates ~2-200 mg/s have been obtained showing good repeatability and uniformity. A calibrated light-emitting diode (LED)-based flowmeter allows measuring and monitoring the drop rate during operation. The fast time-response of the four feeders allows combination of steady and pulsed injections, providing a flexible tool for controlled-dose, real-time impurity injection in fusion plasmas.

47 OTHER INSTRUMENTATION↗

Liquefaction of Forest Biomass to "Drop-in" Hydrocarbon Biofuels

The overall goal of the project was to demonstrate solvent liquefaction as a viable path to stable intermediates for subsequent upgrading to fuel blendstocks. Iowa State University (ISU) utilized technology developed by Chevron to produce “green crude” via continuous biomass liquefaction to bio-oil without catalyst or reducing gas, then upgraded the crude to drop-in hydrocarbon liquid transportation fuels. Original benchmarks for the project included conversion of biomass to bio-oil at a yield of 50% or more, produce bio-oil with oxygen content below 20 wt%, and recycle a portion of the bio-oil product for use as solvent, displacing initial hydrocarbon solvent. Initial testing and technology development was completed by Chevron using a custom Small Continuous Liquefaction Unit (SCLU) operated in “once-through” mode. In this system, liquid product and solid residual/char was collected together and required both off-line solids removal and product separation. This unit was disassembled and major components incorporated into a redesigned solvent liquefaction system at ISU capable of processing biomass at rates up to 1 kg/h. Online, continuous solids separation and bio-oil recovery/separation systems were successfully implemented. Online solids removal using an acetone injection to aid in separation achieved over 99% solids removal efficiency, and acetone recovery of greater than 97% was achieved. The gas stripping system developed for the separation of medium wood oil (MWO) for the recycle stream from the heavy wood oil (HWO) product stream was also successful in recovering approximately 93 wt% of the initial solvent from the biomass-derived products. Due to the generation of fine particulate and the high molecular weight of the HWO which both negatively affect the ability to separate the product oil, solvent recycle was not fully implemented in the system. The biomass used in this project is loblolly pine forest residue. The solvent was a blend of two hydrocarbon liquids. The majority of the solvent was comprised of commercially available naphthalene-depleted heavy aromatic solvent. The hydrogen donor solvent was a proprietary cut of light cycle oil (LCO) that was hydrotreated. As much as 25 wt% of the solvent mixture was comprised of the hydrotreated LCO. Higher blend ratios were limited by the economics of providing hydrogen to the process in this manner. Two cases were evaluated for technical feasibility on the SCLU. These are 1. Simulated phenolic solvent recycle and 2. Hydrocarbon-rich solvent processing. The simulated phenolic solvent recycle case was based on an idealistic solvent mixture where only 5% makeup or hydrogen donor solvent entered the system. The resulting solvent mixture at steady state was estimated to be 75 wt% depleted hydrogen donor, 20 wt% biomass derived phenolic monomers, and 5 wt% HLCO. This case resulted in the highest bio-oil organic yield observed in the project of 66.7 wt% on a solvent-less, dry biomass basis and relatively low oxygen content of 12%. Additionally, these conditions deconstructed the biomass so well, that extremely fine particulate was generated such that 5 micron barrier filters were unable to remove the material. Offline addition of acetone, centrifugation and acetone removal were required in order to remove the particulate prior to fractionation with the stripping column. The resulting HWO had a high molecular weight and was therefore very viscous in nature, remaining solid at room temperature. Additionally, the column was unable to sustainably strip enough MWO to close the recycle loop balance while maintaining flowability of product oil exiting the column. It was determined that additional HLCO would be required at the front of the process to decrease product viscosity both by dilution and additional hydrogen transfer into the HWO product oil. The hydrocarbon rich mixture was the preferred mixture for a majority of the project and featured a 25% donor or HLCO content and 75% depleted hydrogen donor mix. A series of three tests were conducted using this mixture and serve as the basis for a paper detailing the system. While the online acetone injection system for high pressure solids removal was demonstrated early on using this mixture, difficulty controlling process flows led to the use of an atmospheric stirred tank filtration system. At these high donor solvent levels, the product stream easily partitioned with sufficient MWO to close the recycle loop balance. Additionally, this mixture produced HWO product oil at just over 55% yield, <5% oxygen content, and a reasonable viscosity at room temperature. A 56 hour campaign was conducted with the ISU pilot to produce a large enough batch of HWO product oil to conduct upgrading experiments at Chevron’s Richmond, CA facility. Benchtop hydrotreating units were used to conduct long-duration hydrogenation/hydrogenolysis reactions in order to provide yield data and help validate assumptions made in the TEA model. Resulting products featured an oxygen content of <1%, near the detectability limit. Hydrocracking simulations were also performed, and a distribution of heavy wood oil to refinery products was determined. These distributions are based on a database of commercial and pilot plant operation used by Chevron to estimate product yield from novel inputs based on the input physical and chemical characteristics. While multi-week benchtop hydrotreating tests were successfully conducted without fouling, analysis and testing of the heavy wood oil suggest it may be better suited for hydrocracking. Metals content in the heavy wood oil would likely create catalyst fouling over time and reduce lifetime of hydrotreating catalysts. Yields and product partitioning were also more favorable from hydrocracking compared to those from hydrotreating.

09 BIOMASS FUELS↗

Muon Borehole Detector Design for Use in 4-D Density Overburden Monitoring

The increase of atmospheric CO2 concentrations has initiated research into carbon sequestration methods. One possibility is to store CO2 in subsurface porous reservoirs. The monitoring of the injected CO2 plume is vital because escaping CO2 poses health and environmental risks. Typically, seismic reflection methods are used to determine the change in density due to the replacement of brine by CO2 in the reservoir, but this is expensive and not continuous. A potential alternative is to use cosmic muon tomography to measure density changes in the reservoir as a function of time. This paper describes the development of a muon detector that will be capable of being deployed in boreholes. The detector has the required dimensions, an angular resolution of approximately 2 degrees, and is robust. The design is based on alternating layers of scintillating rods, which can provide 4-D tomographic data to detect small changes in density at depths up to approximately 2 km. Geant4, a Monte Carlo simulation code, is being used to develop models to guide the design of the physical configuration. Preliminary testing and measurements have been performed to validate the simulation predictions and optimize the performance of the system. The simulation and preliminary experimental results are presented here.

Borehole Detector, CO¬2 Sequestration, Geant4, Muo↗

Effects of stratification and charge cooling on combustion in a gasoline direct-injection compression ignition (GDCI) engine

With the development of low temperature engine combustion strategies, performance of gasoline-type fuels under compression ignition conditions has attracted extensive research interest. Meanwhile, for the sake of co-optimization of engines and fuels for future ground transportation, identification and evaluation of general fuel properties should be a core research priority instead of endless testing of specific fuels. In this study, the roles of fuel octane sensitivity in characterizing the ignition performance of gasoline surrogates have been systematically investigated under typical gasoline direct ignition compression ignition (GDCI) engine conditions using 3D combustion CFD simulation, especially considering the subsequent in-cylinder charge stratification and charge cooling. Two different operating conditions, high boost pressure low boost temperature (beyond-RON) case and low boost pressure high boost temperature (beyond-MON) case, were considered. By comparing with our previous zero-dimensional chemical kinetic study of gasoline surrogates in advanced compression ignition (ACI) engines, the effects of stratification and charge cooling on the combustion processes are investigated. It is found that different fuel octane sensitivities lead to slight difference in equivalence ratio stratification and charge cooling due to differences in volatility. However, fuel reactivity is still the more dominant factor than the stratification and charge cooling effects in determining combustion phasing. The present results help to justify the P-T domain framework for engine autoignition analysis of overlapping pressure-temperature trajectory with ignition delay iso-contour. Here, the results also provide useful guidance to the understanding of GCI combustion process, and to the evaluation of controlling fuel properties and the selection of alternative fuels in GCI engines.

33 ADVANCED PROPULSION SYSTEMS↗

Effect of ghrelin on the motor deficit caused by the ablation of nigrostriatal dopaminergic cells or the inhibition of striatal dopamine receptors

Highlights: • A functional ghrelin receptor GHSR1a is dominantly found in DA neurons in the SNc. • GHSR1a is also located on GABAergic neurons in the SNr. • Activation of GHSRs on SNc-DA neurons improves motor deficits. • GHSRs located on non-DA cells are not associated with motor function. Ghrelin plays roles in a wide range of central functions by activating the growth hormone secretagogue receptor (GHSR). This receptor has recently been found in the substantia nigra (SN) to control dopamine (DA)-related physiological functions. The dysregulation of DA neurons in the SN pars compacta (SNc) and the consequent depletion of striatal DA are known to underlie the motor deficits observed in Parkinson's disease (PD). In the present study, we further investigated the role of the SN-ghrelin system in motor function under the stereotaxic injection of AAV-CMV-FLEX-diphtheria toxin A (DTA) into the SN of dopamine transporter (DAT)-Cre (DAT{sup SN}::DTA) mice to expunge DA neurons of the SNc. First, we confirmed the dominant expression of GHSR1a, which is a functional GHSR, in tyrosine hydroxylase (TH)-positive DA neurons in the SNc of control mice. In DAT{sup SN}::DTA mice, we clearly observed motor dysfunction using several behavioral tests. An immunohistochemical study revealed a dramatic loss of TH-positive DA neurons in the SNc and DAT-labeled axon terminals in the striatum, and an absence of mRNAs for TH and DAT in the SN of DAT{sup SN}::DTA mice. The mRNA level of GHSR1a was drastically decreased in the SN of these mice. In normal mice, we also found the mRNA expression of GHSR1a within GABAergic neurons in the SN pars reticulata (SNr). Under these conditions, a single injection of ghrelin into the SN failed to improve the motor deficits caused by ablation of the nigrostriatal DA network using DAT{sup SN}::DTA mice, whereas intra-SN injection of ghrelin suppressed the motor dysfunction caused by the administration of haloperidol, which is associated with the transient inhibition of DA transmission. These findings suggest that phasic activation of the SNc-ghrelin system could improve the dysregulation of nigrostriatal DA transmission related to the initial stage of PD, but not the motor deficits under the depletion of nigrostriatal DA. Although GHSRs are found in non-DA cells of the SNr, GHSRs on DA neurons in the SNc may play a crucial role in motor function.

60 APPLIED LIFE SCIENCES↗

Compatibility of an Ultraselective Microcatheter and Epirubicin Loaded 300–500-μm DC Bead in Ex Vivo Study

PurposeThe purpose of this study is to examine whether epirubicin loaded DC Bead 300–500 μm in size can pass through a 1.8-Fr ultraselective microcatheter in ex vivo study.MethodsEpirubicin (25 mg/1 mL) loaded 100–300 and 300–500 μm DC Bead were tested. Both sizes were diluted 5, 10, and 30 times using contrast material. Ultraselective microcatheter with the outer diameter of 1.8 Fr and the inner diameter of .017 inch (431.8 μm) was used. The diluted DC Bead was injected at a speed of 1 mL/min, and the pressure was continuously measured. The microspheres’ shapes after ejection were observed by a stereomicroscope.ResultsThe maximum pressure of contrast material alone was 8.40 ± 0.21 psi. The maximum pressure in 5, 10, and 30 times dilution groups of 100–300 μm were 9.67 ± 1.18, 9.25 ± 0.25, and 9.71 ± 0.28 psi, respectively, whereas 21.10 ± 10.2, 10.48 ± 2.14, 10.09 ± 0.37 psi, respectively in 300–500 μm groups. The maximum pressure in 5 times dilution group of 300–500 μm was significantly higher than the other groups (P < 0.05). In 300–500 μm, 4 of 10 measurements showed high pressure over 24 psi (the maximum value was 43.5 psi) in 5 times dilution group, whereas in 10 times and 30 times dilution groups, all measurements showed less than 12 psi. No damages of microspheres were found.ConclusionsEpirubicin loaded DC Bead 300–500 μm in size can pass through a 1.8-Fr ultraselective microcatheter. To avoid high resistance due to microspheres’ aggregation, dilution more than 10 times is needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utah FORGE: Wells 16A(78)-32 and 16B(78)-32 Stimulation Program Report - May 2024

This dataset consists of a comprehensive report documenting the stimulation program conducted in May 2024 on Utah FORGE wells 16A(78)-32 and 16B(78)-32. It includes detailed accounts of operational and scientific objectives, stimulation methodologies, and testing outcomes. The report describes the hydraulic fracturing activities, equipment setups, proppant and fluid usage, and the execution of a nine-hour circulation test. It also includes observations from seismic and fiber optic monitoring systems, providing data on microseismic activity and fracture propagation. Detailed parameters for each stimulation stage are provided, alongside operational challenges and solutions. The dataset includes analyses of injection and production rates, well temperatures, and pressure data, supported by graphical illustrations and logs.

15 GEOTHERMAL ENERGY↗

Plasma Processing of SRF Cavities at Jefferson Lab

Jefferson Lab has an ongoing R&D program in plasma processing which is close to going into production pro-cessing in the CEBAF accelerator. Plasma processing is a common technique for removing hydrocarbons from surfaces, which increases the work function and reduces the secondary emission coefficient [1]. The initial focus of the effort is processing C100 cavities by injecting RF power into the HOM coupler ports. The goal will be to improve the operational gradients and the energy margin of the CEBAF linacs by processing cryomodules in situ. Results from processing a cryomodule in the cryomodule test bunker as well as cavity vertical test results will be presented. This work describes the systems and methods used at JLAB for processing cavities using an ar-gon/oxygen gas mixture.

Powers, T.↗

One Earth Energy Static and Dynamic Reservoir Modeling

This report presents the static and dynamic reservoir modeling conducted for the CarbonSAFE Phase III Illinois Storage Corridor project to assess the feasibility of commercial-scale CO 2 storage in the Mt. Simon Sandstone at the One Earth Energy (OEE) site in McLean County, Illinois. Three-dimensional geocellular models of the Mt. Simon storage complex were developed in Petrel ® by integrating petrophysical log data, core analyses, and seismic surveys from the OEE #1 stratigraphic test well and two nearby wells, with multiple model versions created as new data became available. Dynamic reservoir simulations, performed using Landmark's Nexus software, progressed through three phases (preliminary, sensitivity, and UIC Class VI permit studies) evaluating injection scenarios across varying rates, well orientations, permeability models, and multi-well configurations. Results demonstrate that commercial-scale storage is feasible: three injection wells spaced approximately one mile apart can store a total of 90 million tonnes of CO 2 over 20 years, producing a combined plume with an equivalent radius of 3.2 miles and a maximum pressure-front-defined Area of Review of 178 mi 2 at the end of injection that diminishes to 34 mi 2 after 50 years of post-injection monitoring. Sensitivity analyses indicate that a 20% change in porosity or permeability yields approximately a 7% change in AoR radius, and that perforating the high-permeability arkosic zone minimizes the pressure front compared to injection in the upper Mt. Simon Sandstone.

09 BIOMASS FUELS↗

Knock-limited combustion of ethanol-, isobutanol-, and 2-methyl-3-buten-2-ol-gasoline blends in a direct-injected spark-ignition engine

Knock-limited combustion of alcohol-gasoline fuel blends was studied in a direct-injection spark-ignition engine. Ethanol, isobutanol (2-methyl-1-propanol), and methylbutenol (2-methyl-3-buten-2-ol) were splash-blended with a blendstock for oxygenate blending (BOB) gasoline. Ethanol was blended in fractions of 10%, 20%, and 30% by volume (E10, E20, and E30). Isobutanol and methylbutenol were blended to match the oxygen weight percentage of the ethanol blends, resulting in blends of 16%, 32%, and 49% (I16, I32, and I49) isobutanol by volume and 18%, 37%, and 56% (M18, M37, and M56) methylbutenol by volume. Neat BOB and gasoline primary reference fuels (PRF) with octane numbers (ON) of 87 (PRF87) and 100 (PRF100) were included for reference. The engine was operated at fixed speed, equivalence ratio, and injection timing while knock-limited spark advance was located across a range of intake pressures. Low-level alcohol blends E10 and M18 had similar knocking behavior and appeared to be slightly more knock-resistant than I16. For mid-level blends, E20 showed further improvement over I32 while M37 showed noticeably better knock resistance, able to match the knock-resistance of PRF100 for loads above 1000 kPa gross indicated mean effective pressure (GIMEP). For high-level blends, the difference between E30 and I49 was similar to their mid-level counterparts. However, M56 showed significant improvement over E30 and I49 throughout the entire range of loads tested. M56 exceeded the knock-resistance of PRF100 for loads above 700 kPa GIMEP. The improved knock-resistance combined with the increased volumetric energy density of methylbutenol resulted in improved fuel consumption and indicated efficiency. The overall results of this study indicate that the order of knock-resistance of these three alcohols, for direct-injection operation with injection during the intake stroke, is isobutanol < ethanol < methylbutenol when compared on an equal oxygen weight basis.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of Adaptive Volt-VAR to Mitigate PV Impacts [Slides]

Distributed generation (DG) sources like photovoltaic (PV) systems with advanced inverters are able to perform grid-support functions, like autonomous Volt-VAR that attempts to mitigate voltage issues by injecting or consuming reactive power. However, the Volt-VAR function operates with VAR priority, meaning real power may be curtailed to provide additional reactive power support. Since some locations on the grid may be more prone to higher voltages than others, PV systems installed at those locations may be forced to curtail more power, adversely impacting the value of that PV system. Adaptive Volt-VAR (AVV) could be implemented as an alternative, whereby the Volt-VAR reference voltage changes over time, but this functionality has not been well-explored in the literature. In this work, the potential benefits and grid impacts of AVV were investigated using yearlong quasi-static time-series (QSTS) simulations. After testing a variety of allowable AVV settings, we found that even with aggressive settings AVV resulted in <0.01% real power curtailment and significantly reduced the reactive power support required from the PV inverter compared to conventional Volt-VAR but did not provide much mitigation for extreme voltage conditions. The reactive power support provided by AVV was injected to oppose large deviations in voltage (in either direction), indicating that it could be useful for other applications like reducing voltage flicker or minimizing interactions with other voltage regulating devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗