Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instruments & Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Building a Simplistic Automatic Extruder: Instrument Development Opportunities for the Laboratory

This work presents an automatic extruder as a research experience for undergraduate students. The system offers a user-friendly approach to preparing vesicles, such as liposomes or polymersomes, with a defined size and polydispersity properties crucial for research in biology and macromolecules. It comprises two syringe pumps connected by a membrane filter. The setup is controlled by software. Compared to manual extrusion, this automated system provides advantages, such as precisely controlled variables. The project describes a tool to enhance undergraduate learning in science and engineering laboratories. Building an automatic extruder serves as a simplified model of a complex industrial process. It offers a clear advantage: automating a well-understood manual extrusion process. To make this project accessible, it is broken down into three manageable tasks: software development, hardware assembly, and testing procedures. This breakdown describes the software created, the hardware components used, and the testing procedures conducted for this project. All project data, including software code, testing data, and procedures, are freely available online. This allows undergraduate students to not only begin their own projects but also contribute to this educational instrument’s ongoing development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Instrument for Time-Resolved OH and HO 2 Quantification in High-Pressure Laboratory Kinetics Studies

Here, we have constructed a new time-resolved high-pressure fluorescence assay by gas expansion (HP-FAGE) apparatus, optimized for the detection of OH and HO 2 radicals in complex gas-phase reactions. The new instrument fills a gap in the existing experimental toolkit for chemical kinetics by enabling the quantification of two key reactive species with microsecond time resolution from high-pressure sources, which was previously not attainable. The HP-FAGE is interfaced with a flow reactor, designed for pressures up to 100 bar and temperatures up to 1000 K, in which reactions are initiated by laser photolysis of radical precursors at repetition rates of 1–10 Hz. The HP-FAGE samples gas out of the reactor into a miniature FAGE chamber, where OH is detected by resonant laser-induced fluorescence using a time-delayed probe laser pulse. HO 2 is converted to OH via reaction with NO and then detected by OH fluorescence. The novel FAGE design places the probe region very close to the gas expansion, minimizing the transport time of sampled molecules and resulting in time resolution better than 20 μs for both OH and HO 2 . We calibrate the sensitivity of HP-FAGE, validate its performance with measurements of well-known reaction kinetics (OH + CH 4 , OH + OH, OH + HO 2 , and HO 2 + HO 2 ), and discuss prospects for its future use.

calibration↗

POLARRIS: A POLArimetric Radar Retrieval and Instrument Simulator

This paper introduces a synthetic polarimetric radar simulator and retrieval package, POLArimetric Radar Retrieval and Instrument Simulator (POLARRIS), for evaluating cloud-resolving models (CRMs). POLARRIS is composed of forward (POLARRIS-f) and inverse (retrieval and diagnostic) components (iPOLARRIS) to generate not only polarimetric radar observables ($Z_h, Z_{dr}, K_{dp}, ρ_{hv})$ but also radar-consistent geophysical parameters such as hydrometeor identification, vertical velocity, and rainfall rates retrieved from CRM data. To demonstrate its application and uncertainties, POLARRIS is applied to simulations of a mesoscale convective system over the Southern Great Plains on 23 May 2011, using the Weather Research and Forecasting model with both spectral bin microphysics (SBM) and the Goddard single-moment bulk 4ICE microphysics. Statistical composites reveal a significant dependence of simulated polarimetric observables $(Z_{dr}, K_{dp})$ on the assumptions of the particle axis ratio (oblateness) and orientation angle distributions. We note the simulated polarimetric variables differ considerably between the SBM and 4ICE microphysics in part due to the differences in their ice particle size distributions as revealed by comparisons with aircraft measurements. Regardless of these uncertainties, simulated hydrometeor identification distributions overestimate graupel and hail fractions, especially from the simulation with SBM. To minimize uncertainties in forward model, the particle shape and orientation angle distributions of frozen particles should be predicted in a microphysics scheme in addition to the size distributions and particle densities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planck 2013 results. IV. Low Frequency Instrument beams and window functions

This paper presents the characterization of the in-flight beams, the beam window functions, and the associated uncertainties for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is necessary for determining the transfer function to go from the observed to the actual sky anisotropy power spectrum. The main beam distortions affect the beam window function, complicating the reconstruction of the anisotropy power spectrum at high multipoles, whereas the sidelobes affect the low and intermediate multipoles. The in-flight assessment of the LFI main beams relies on the measurements performed during Jupiter observations. By stacking the datafrom multiple Jupiter transits, the main beam profiles are measured down to-20 dB at 30 and 44 GHz, and down to-25 dB at 70 GHz. The main beam solid angles are determined to better than 0.2% at each LFI frequency band. The Planck pre-launch optical model is conveniently tuned to characterize the main beams independently of any noise effects. This approach provides an optical model whose beams fully reproduce the measurements in the main beam region, but also allows a description of the beams at power levels lower than can be achieved by the Jupiter measurements themselves. The agreement between the simulated beams and the measured beams is better than 1% at each LFI frequency band. The simulated beams are used for the computation of the window functions for the effective beams. The error budget for the window functions is estimated from both main beam and sidelobe contributions, and accounts for the radiometer bandshapes. The total uncertainties in the effective beam window functions are: 2% and 1.2% at 30 and 44 GHz, respectively (at ℓ ≈ 600), and 0.7% at 70 GHz (at ℓ ≈ 1000).

79 ASTRONOMY AND ASTROPHYSICS↗

Planck 2013 results. II. Low Frequency Instrument data processing

We describe the data processing pipeline of the Planck Low Frequency Instrument (LFI) data processing centre (DPC) to create and characterize full-sky maps based on the first 15.5 months of operations at 30, 44, and 70 GHz. In particular, we discuss the various steps involved in reducing the data, from telemetry packets through to the production of cleaned, calibrated timelines and calibrated frequency maps. Data are continuously calibrated using the modulation induced on the mean temperature of the cosmic microwave background radiation by the proper motion of the spacecraft. Sky signals other than the dipole are removed by an iterative procedure based on simultaneous fitting of calibration parameters and sky maps. Noise properties are estimated from time-ordered data after the sky signal has been removed, using a generalized least squares map-making algorithm. A destriping code (Madam) is employed to combine radiometric data and pointing information into sky maps, minimizing the variance of correlated noise. Noise covariance matrices, required to compute statistical uncertainties on LFI and Planck products, are also produced. Main beams are estimated down to the ≈-20 dB level using Jupiter transits, which are also used for the geometrical calibration of the focal plane.

79 ASTRONOMY AND ASTROPHYSICS↗

Planck 2015 results: IV. Low Frequency Instrument beams and window functions

This article presents the characterization of the in-flight beams, the beam window functions, and the associated uncertainties for the Planck Low Frequency Instrument (LFI). The structure of the paper is similar to that presented in the 2013 Planck release; the main differences concern the beam normalization and the delivery of the window functions to be used for polarization analysis. The in-flight assessment of the LFI main beams relies on measurements performed during observations of Jupiter. By stacking data from seven Jupiter transits, the main beam profiles are measured down to -25 dB at 30 and 44 GHz, and down to -30 dB at 70 GHz. It has been confirmed that the agreement between the simulated beams and the measured beams is better than 1% at each LFI frequency band (within the 20 dB contour from the peak, the rms values are 0.1% at 30 and 70 GHz; 0.2% at 44 GHz). Simulated polarized beams are used for the computation of the effective beam window functions. The error budget for the window functions is estimated from both main beam and sidelobe contributions, and accounts for the radiometer band shapes. The total uncertainties in the effective beam window functions are 0.7% and 1% at 30 and 44 GHz, respectively (at ℓ ≈ 600); and 0.5% at 70 GHz (at ℓ ≈ 1000).

79 ASTRONOMY AND ASTROPHYSICS↗

Planck 2015 results: VIII. High Frequency Instrument data processing: Calibration and maps

This paper describes the processing applied to the cleaned, time-ordered information obtained from the Planck High Frequency Instrument (HFI) with the aim of producing photometrically calibrated maps in temperature and (for the first time) in polarization. The data from the entire 2.5-year HFI mission include almost five full-sky surveys. HFI observes the sky over a broad range of frequencies, from 100 to 857 GHz. To obtain the best accuracy on the calibration over such a large range, two different photometric calibration schemes have been used. The 545 and 857 GHz data are calibrated using models of planetary atmospheric emission. The lower frequencies (from 100 to 353 GHz) are calibrated using the time-variable cosmological microwave background dipole, which we call the orbital dipole. This source of calibration only depends on the satellite velocity with respect to the solar system. Using a CMB temperature of T CMB = 2.7255 ± 0.0006 K, it permits an independent measurement of the amplitude of the CMB solar dipole (3364.3 ± 1.5 μK), which is approximatively 1σ higher than the WMAP measurement with a direction that is consistent between the two experiments. We describe the pipeline used to produce the maps of intensity and linear polarization from the HFI timelines, and the scheme used to set the zero level of the maps a posteriori. We also summarize the noise characteristics of the HFI maps in the 2015 Planck data release and present some null tests to assess their quality. Lastly, we discuss the major systematic effects and in particular the leakage induced by flux mismatch between the detectors that leads to spurious polarization signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Planck 2018 results: III. High frequency instrument data processing and frequency maps

This paper presents the High Frequency Instrument (HFI) data processing procedures for the Planck 2018 release. Major improvements in mapmaking have been achieved since the previous Planck 2015 release, many of which were used and described already in an intermediate paper dedicated to the Planck polarized data at low multipoles. These improvements enabled the first significant measurement of the reionization optical depth parameter using Planck-HFI data. This paper presents an extensive analysis of systematic effects, including the use of end-to-end simulations to facilitate their removal and characterize the residuals. The polarized data, which presented a number of known problems in the 2015 Planck release, are very significantly improved, especially the leakage from intensity to polarization. Calibration, based on the cosmic microwave background (CMB) dipole, is now extremely accurate and in the frequency range 100-353 GHz reduces intensity-to-polarization leakage caused by calibration mismatch. The Solar dipole direction has been determined in the three lowest HFI frequency channels to within one arc minute, and its amplitude has an absolute uncertainty smaller than 0.35 μK, an accuracy of order 10 -4 . This is a major legacy from the Planck HFI for future CMB experiments. The removal of bandpass leakage has been improved for the main high-frequency foregrounds by extracting the bandpass-mismatch coefficients for each detector as part of the mapmaking process; these values in turn improve the intensity maps. This is a major change in the philosophy of "frequency maps", which are now computed from single detector data, all adjusted to the same average bandpass response for the main foregrounds. End-to-end simulations have been shown to reproduce very well the relative gain calibration of detectors, as well as drifts within a frequency induced by the residuals of the main systematic effect (analogue-to-digital convertor non-linearity residuals). Using these simulations, we have been able to measure and correct the small frequency calibration bias induced by this systematic effect at the 10 -4 level. There is no detectable sign of a residual calibration bias between the first and second acoustic peaks in the CMB channels, at the 10 -3 level.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-density laboratory spectra near the λ 335 channel of the SDO/AIA instrument

For a more complete interpretation of the extreme-ultraviolet (EUV) spectra of the solar corona, it is beneficial to acquire laboratory data of specific chemical elements obtained under coronal conditions. The EUV spectra of He, C, N, O, F, Ne, S, Ar, Fe, and Ni in a 30 Å wide wavelength interval near 335 have been excited in an electron beam ion trap. Results. We observe just under 200 lines, almost half of which are not yet identified and included in spectral models. Furthermore, our data serve as a check on atomic databases that are used to interpret solar corona data such as collected by the Solar Dynamics Observatory spacecraft or the EUNIS instrument on sounding rockets. Furthermore, our findings largely corroborate the databases. However, the accumulated flux of a multitude of mostly weak additional lines is comparable to that of various primary lines.

74 ATOMIC AND MOLECULAR PHYSICS↗

Invited Review Article: Contemporary instrumentation and application of charge exchange neutral particle diagnostics in magnetic fusion energy experiments

An overview of the developments postcirca 1980s in the instrumentation and application of charge exchange neutral particle diagnostics on magnetic fusion energy experiments is presented. First, spectrometers that employ only electric fields and hence provide ion energy resolution but not mass resolution are discussed. Next, spectrometers that use various geometrical combinations of both electric and magnetic fields to provide both energy and mass resolutions are reviewed. Finally, neutral particle diagnostics based on utilization of time-of-flight techniques are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring Quantum Gravity with Very-High-Energy Gamma-Ray Instruments - Prospects and Limitations

Some models for quantum gravity (QG) violate Lorentz invariance and predict an energy dependence of the speed of light, leading to a dispersion of high-energy gamma-ray signals that travel over cosmological distances. Limits on the dispersion from short-duration substructures observed in gamma-rays emitted by gamma-ray bursts (GRBs) at cosmological distances have provided interesting bounds on Lorentz invariance violation (LIV). Recent observations of unprecedentedly fast flares in the very-high energy gamma-ray emission of the active galactic nuclei (AGNs) Mkn 501 in 2005 and PKS 2155-304 in 2006 resulted in the most constraining limits on LIV from light-travel observations, approaching the Planck mass scale, at which QG effects are assumed to become important. I review the current status of LIV searches using GRBs and AGN flare events, and discuss limitations of light-travel time analyses and prospects for future instruments in the gamma-ray domain.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Fermi Gamma-ray Burst Monitor Instrument

The Fermi Gamma-ray Space Telescope launched on June 11, 2008 carries two experiments onboard--the Large Area Telescope (LAT) and the Gamma-ray Burst Monitor (GBM). The primary mission of the GBM instrument is to support the LAT in observing {gamma}-ray bursts (GRBs) by providing low-energy measurements with high temporal and spectral resolution as well as rapid burst locations over a large field-of-view ({>=}8 sr). The GBM will complement the LAT measurements by observing GRBs in the energy range 8 keV to 40 MeV, the region of the spectral turnover in most GRBs. The GBM detector signals are processed by the onboard digital processing unit (DPU). We describe some of the hardware features of the DPU and its expected limitations during intense triggers.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanopositioning techniques development for synchrotron radiation instrumentation applications at the Advanced Photon Source

At modern synchrotron radiation sources and beamlines, high-precision positioning techniques present a significant opportunity to support state-of-the-art synchrotron radiation research. Meanwhile, the required instrument positioning performance and capabilities, such as resolution, dynamic range, repeatability, speed, and multiple axes synchronization are exceeding the limit of commercial availability. This paper presents the current nanopositioning techniques developed for the Argonne Center for Nanoscale Materials (CNM)/Advanced Photon Source (APS) hard x-ray nanoprobe and high-resolution x-ray monochromators and analyzers for the APS X-ray Operations and Research (XOR) beamlines. Future nanopositioning techniques to be developed for the APS renewal project will also be discussed.

43 PARTICLE ACCELERATORS↗

Beamline Control and Instrumentation System using Industrial Interface Techniques

How should a beamline be designed, which satisfies the needs and requirements of scientists and is easy to build and operate? Today, most control and instrumentation systems for beamlines are based on scientific requirements. Scientific details of the beamline, e.g. vacuum and beam physics details; are usually extensively described. However, control system specifications are often reduced to few requirements, e.g. which beam-related device to use. Lots of these systems work perfectly from the physicist's point of view, but are hard to bring into service and operate and difficult to extend with additional equipment. To overcome this, the engineering company ENZ has developed components using industrial standard interfaces to guarantee high flexibility for equipment extension. Using special interface boards and galvanic isolation offers increased stability of motion control axes. This saves resources during commissioning and service. A control system was developed and installed at a Soft-X-ray beamline at ASP Melbourne. It is operated under EPICs on distributed embedded IOC's based on PC-hardware. Motion and vacuum systems, measurement devices, e.g. a Low-Current Monitor (LoCuM) for beam position monitoring, and parts of the equipment protection system were developed and most of them tested in cooperation with DELTA at the Technical University of Dortmund.

43 PARTICLE ACCELERATORS↗

Design and specifications of the diagnostics for the instrumented calorimeter of Source for the Production of Ions of Deuterium Extracted from Radio frequency plasma

In the development of the neutral beam injector for ITER experiment, the test facility SPIDER is going to be built. To measure the beam parameters, several diagnostics are used. One of them is the Short-Time Retractable Instrumented Kalorimeter Experiment (STRIKE) which measures beam uniformity, beamlet divergence, and stripping losses. This contribution gives an overview of the diagnostics dedicated to these measurements: thermal cameras, thermocouples, current sensors, and electrostatic sensors. The specifications of these diagnostics have been defined according to the results of electrostatic and thermal simulations. A failure modes and effects analysis has been performed during the design. Consequently the project of the STRIKE diagnostics has been optimized to reduce the possible failure risks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The beam diagnostic instruments in Beijing radioactive ion-beam facilities isotope separator on-line

The beam diagnostic instruments for Beijing Radioactive Ion-beam Facilities Isotope Separator On-Line are introduced [B. Q. Cui, Z. H. Peng, Y. J. Ma, R. G. Ma, B. Tang, T. Zhang, and W. S. Jiang, Nucl. Instrum. Methods 266, 4113 (2008); T. J. Zhang, X. L. Guan, and B. Q. Cui, in Proceedings of APAC 2004, Gyeongju, Korea, 2004, http://www.jacow.org , p. 267]. For low intensity ion beam [30–300 keV/1 pA–10 μA], the beam profile monitor, the emittance measurement unit, and the analyzing slit will be installed. For the primary proton beam [100 MeV/200 μA], the beam profile scanner will be installed. For identification of the nuclide, a beam identification unit will be installed. The details of prototype of the beam diagnostic units and some experiment results will be described in this article.

43 PARTICLE ACCELERATORS↗

Calibration facility for environment dosimetry instruments

In the last ten years, the nuclear activities, as well as the major nuclear events (see Fukushima accident) had an increasing impact on the environment, merely by contamination with radioactive materials. The most conferment way to quickly identify the presence of some radioactive elements in the environment, is to measure the dose-equivalent rate H. In this situation, information concerning the values of H due only to the natural radiation background must exist. Usually, the values of H due to the natural radiation background, are very low (∼10{sup −9} - 10{sup −8} Sv/h). A correct measurement of H in this range involve a performing calibration of the measuring instruments in the measuring range corresponding to the natural radiation background lead to important problems due to the presence of the natural background itself the best way to overlap this difficulty is to set up the calibration stand in an area with very low natural radiation background. In Romania, we identified an area with such special conditions at 200 m dept, in a salt mine. This paper deals with the necessary requirements for such a calibration facility, as well as with the calibration stand itself. The paper includes also, a description of the calibration stand (and images) as well as the radiological and metrological parameters. This calibration facilities for environment dosimetry is one of the few laboratories in this field in Europe.

61 RADIATION PROTECTION AND DOSIMETRY↗

SwissFEL instrument ESB femtosecond pump-probe diffraction and scattering

The ESB instrument at the SwissFEL ARAMIS hard X-ray free electron laser is designed to perform pump-probe experiments in condensed matter and material science employing photon-in and photon-out techniques. It includes a femtosecond optical laser system to generate a variety of pump beams, a X-ray optical scheme to tailor the X-ray probe beam, shot-to-shot diagnostics to monitor the X-ray intensity and arrival time, and two endstations operated at a single focus position that include multi-purpose sample environments and 2D pixel detectors for data collection.

43 PARTICLE ACCELERATORS↗