Locational Marginal Pricing in the Campus Power System at the Power Distribution Level

In the development of smart grid at distribution level, the realization of real-time nodal pricing is one of the key challenges. The research work in this paper implements and studies the methodology of locational marginal pricing at distribution level based on a real-world distribution power system. The pricing mechanism utilizes optimal power flow to calculate the corresponding distributional nodal prices. Both Direct Current Optimal Power Flow and Alternate Current Optimal Power Flow are utilized to calculate and analyze the nodal prices. The University of Denver campus power grid is used as the power distribution system test bed to demonstrate the pricing methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Locational Marginal Pricing (DLMP) for Congestion Management and Voltage Support

In this paper, a day-ahead market-clearing model for smart distribution systems is proposed. Various types of distributed energy resources (DERs), such as distributed energy storage, distributed generators, microgrids, and load aggregators, can bid into the day-ahead distribution-level electricity market. Considering system Volt/VAR control, network reconfiguration, and interactions with the wholesale market, an optimization model is built to clear the day-ahead market, through which the distribution locational marginal pricing (DLMPs) for both active power and reactive power are determined. Through derivations of the Lagrangian function and sensitivity factors, DLMPs are decomposed to five components (i.e., marginal costs for active power, reactive power, congestion, voltage support, and loss), which provide price signals to motivate DERs to contribute to congestion management and voltage support. Finally, case studies demonstrate the effectiveness of the proposed method.

congestion management↗

Robust Distribution State Estimation for Reliable Locational Marginal Pricing under Cyber-Attacks

Here this paper examines the impact of false data injection (FDI) cyber-attacks on distribution system state estimation (DSSE) and the resulting distribution locational marginal price (DLMP) in power markets. Two robust high-breakdown regression estimators, namely S- and MM- estimators, are implemented to provide resistance against FDI attacks targeting measurements and grid topology, creating leverage points. The introduced estimators are compared to the weighted least squares (WLS) with a bad data detection and rejection module (BDD) and the robust Huber M-estimator. The proposed estimators are shown to be effective and compare favorably to both existing Huber M- and the WLS with BDD in the presence of topology FDI attacks. Both the S- and MM-estimators provide good performance in the case of clean and corrupted measurements. Their performance is comparable in this case to the Huber M- and the WLS, followed by a BDD module. The simulation considered a modified distribution IEEE 13 and 34-bus systems where the impact of FDI attack scenarios is shown on the state and the DLMP pricing in the presence of distributed Generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Google Earth Locations of USA and Seafloor Hydrothermal Vents with Associated Rare Earth Element Data

Google Earth .kmz files that contain the locations of geothermal wells and thermal springs in the USA, and seafloor hydrothermal vents that have associated rare earth element data. The file does not contain the actual data, the actual data is available through the GDR website in two tier 3 data sets entitled "Compilation of Rare Earth Element Analyses from US Geothermal Fields and Mid Ocean Ridge (MOR) Hydrothermal Vents" and "Rare earth element content of thermal fluids from Surprise Valley, California"

15 GEOTHERMAL ENERGY↗

Hanford Single-Shell Tank Leak Causes and Locations - 241-B Farm

This document identifies 241-B Tank Farm (B Farm) leak cause and locations for the 100 series leaking tank (241-B-107) identified in RPP-RPT-49089, Hanford B-Farm Leak Inventory Assessments Report. This document satisfies the B Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Single-Shell Tank Leak Causes and Locations - 241-C Farm

This document identifies 241-C Tank Farm (C Farm) leak causes and locations for the 100 series leaking tanks (241-C-101 and 241-C-105) identified in RPP-RPT-33418, Rev. 2, Hanford C-Farm Leak Inventory Assessments Report. This document satisfies the C Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Single-Shell Tank Leak Causes and Locations - 241-A Farm

This document identifies 241-A Tank Farm (A Farm) leak causes and locations for the 100 series leaking tanks (241-A-104 and 241-A-105) identified in RPP-ENV-37956, Hanford A and AX Farm Leak Assessment Report. This document satisfies the A Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Single-Shell Tank Leak Causes and Locations - 241-U Farm

This document identifies 241-U Tank Farm (U Farm) leak causes and locations for the 100 series leaking tanks (241-U-104, 241-U-110, and 241-U-112) identified in RPP-RPT-50097, Rev. 0, Hanford 241-U Farm Leak Inventory Assessment Report. This document satisfies the U-Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Single-Shell Tank Leak Causes and Locations - 241-SX Farm

This document identifies 241-SX Tank Farm (SX Farm) leak causes and locations for the 100 series leaking tanks (241-SX-107, 241-SX-108, 241-SX-109, 241-SX-111, 241-SX-112, 241-SX-113, 241-SX-114, and 241-SX-115) identified in RPP-ENV-39658, Rev. 0, Hanford SX-Farm Leak Assessments Report. This document satisfies the SX Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Single-Shell Tank Leak Causes and Locations - 241-T Farm

This document identifies 241-T Tank Farm (T Farm) leak causes and locations for the 100 series leaking tanks (241-T-106 and 241-T-111) identified in RPP-RPT-55084, Rev. 0, Hanford 241-T Farm Leak Inventory Assessment Report. This document satisfies the T Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternative Fueling Station Locations

Alternative fueling stations are located throughout the United States and Canada, and their availability continues to grow. The Alternative Fuels Data Center (AFDC) maintains a website where you can find alternative fueling stations near you or on a route, obtain counts of alternative fueling stations by state, view maps, and more. The most recent dataset available for download here provides a "snapshot" of the alternative fueling station information for compressed natural gas (CNG), ethanol (E85), propane/liquefied petroleum gas (LPG), biodiesel (B20 and above), electric vehicle charging, hydrogen, and liquefied natural gas (LNG), as of July 29, 2021.

alt fuel↗

Defining a Use Case for the ADMS Test Bed: Fault Location, Isolation, and Service Restoration with Distributed Energy Resources: Preprint

Advanced distribution management systems (ADMS) integrate multiple enterprise-level functions into a single platform and offer advanced applications such as fault location, isolation, and service restoration (FLISR), to utilities to meet their operational needs for a modernized grid. These applications need to operate reliably even as distributed energy resource (DER) penetration increases on distribution systems. The ADMS test bed at the National Renewable Energy Laboratory offers utilities and vendors the opportunity to evaluate the performance of such advanced applications on distribution feeders of the future and to understand their potential benefits for a specific utility. This is done through defining use cases that address specific questions. This paper presents the definition of a use case on the performance of a commercially-available FLISR application on a feeder of an electric cooperative with DERs. Results from this use case will be disseminated to the electric utility and research community to improve understanding of the challenges and benefits that DERs present to ADMS applications and the operation of a modernized grid.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Single-Site Platinum CO Oxidation Catalyst in Zeolite KLTL: Microscopic and Spectroscopic Determination of the Locations of the Platinum Atoms

A stable site-isolated mononuclear platinum catalyst with a well-defined structure is presented. Platinum complexes supported in zeolite KLTL were synthesized from [Pt(NH 3 ) 4 ](NO 3 ) 2 , oxidized at 633 K, and used to catalyze CO oxidation. Finally, IR and X-ray absorption spectra and electron micrographs determine the structures and locations of the platinum complexes in the zeolite pores, demonstrate the platinum-support bonding, and show that the platinum remained site isolated after oxidation and catalysis.

N12994↗

Vegetation and location of water inflow affect evaporation in a subtropical wetland as indicated by the deuterium excess method: Evaporation Effects Indicated by Deuterium Excess Method

Evaporation represents a principal form of water loss from water bodies, but quantifying evaporation with transpiring vegetation is challenging, owing to the difficulties in disentangling evaporation from transpiration. As the two processes have different effects on water isotope signatures (i.e., oxygen and hydrogen stable isotope ratios expressed by δ 18 O and δ 2 H), we used both the δ 18 O and δ 2 H values of water samples to calculate their deuterium excess (d) values, which are proportionate to fraction of evaporation loss (E f ) of water being sampled. Comparing with a single isotope method, the d method holds the advantage that it does not require knowledge of the initial isotope ratios of source water. Limitations of the d method, for example, effects of prior-evaporation of water before entering water bodies, can be checked and corrected. The sampling locations throughout our study site differed in vegetation coverage, water depth, and distance to water inflow (or discharge gate of water inflow), which are three important factors in water management. This sampling design offered us a unique opportunity to quantify the influences of the above three factors on E f . We found the following: (1) There was a spatiotemporal pattern in δ 18 O distribution. (2) The E f was negatively related to the vegetation coverage, positively related to distance to the water source inflow but nonsignificantly related to water depth. Therefore, vegetation and distance to the water inflow are two important considerations for the control of evaporative water loss, and evaporation calculated by the d method can lead to more informed water management.

54 ENVIRONMENTAL SCIENCES↗