Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Understanding In-Situ Structure and Chemistry at Battery Interfaces Through Time-Resolved Cryo-EM

Transmission and scanning transmission electron microscopy are vital tools for characterizing interfacial structure and chemistry at high spatial resolutions but are limited by the fact that many materials are quickly damaged by electron beam irradiation. This is a challenge particularly for materials relevant to energy applications, such as lithium-containing battery materials, organic-inorganic hybrids, and liquid electrolytes. Cryogenic electron microscopy (cryo-EM) offers a partial solution to this issue by stabilizing beam-sensitive solid-solid or solid-liquid interfaces for characterization, but typical cryo-EM sample preparations are ex situ and thus cannot capture interfaces in their electrified state of interest to applications. Here, we present a method to prepare cryo-EM samples of electrified battery interfaces in situ to preserve the time-resolved structures and chemistry that arise under applied current or bias.

batteries↗

Study of an unrefined humate solution as a possible remediation method for groundwater contamination - 15698

Savannah River Site (SRS) was one of the major nuclear processing facilities in the U.S. where plutonium was produced during the Cold War. Approximately 1.8 billion gallons of low level acidic waste solution containing radionuclides and dissolved metals were discharged to a series of unlined seepage basins at the F/H Area. Uranium is a key contaminant of concern in the basin's groundwater. It is migrating into the groundwater creating an acidic plume with a pH between 3-5.5. Groundwater Actions: The pump-and-treat water treatment unit was designed and built in 1997 to remove metals and radionuclides. In 2004 a hybrid funnel-and-gate system was constructed to create a treatment zone in which the acidic nature of the contaminated sediments could be reversed. Huma-K is an organic fertilizer that comes from the alkaline extraction of leonardite (a low-rank coal). Huma-K has a high content of humic substances which consist of complex organic compounds formed by the decomposition of plant and animal tissue. The objective of this study is to determine if a low cost unrefined humate solution (Huma-K) can be used to facilitate uranium adsorption to control its mobility in acidic groundwater. This study can assist in evaluating whether Huma-K can be used as an in situ amendment for the remediation of groundwater contaminated with uranium. Sediments from FAW-1 70-90 ft were used in this experiment. Sediments were disaggregated and sieved to a particle size of . 2 mm. Concentrations in the range 10-500 ppm were tested. Once all the components were added, pH was adjusted to 4. Samples were vortex mixed and placed on a shaker table at 100 RPM for a period of 24 hours in order to reach the adsorption equilibrium. Once the adsorption equilibrate was reached, samples were centrifuged at 2700 RPM to separate the liquid and the solid phase. The liquid fraction was analyzed using a Thermo Scientific Genesys 10S UV-Vis spectrophotometer. The same experimental design was used as explained above. A known concentration of Huma-K was used to study the pH effect on the sorption process. pH values were measured at the beginning and at the end of the experiment. Spectra of Huma-K show a featureless character. Absorbance of light increases as the wavelength is decreased. Measurements were done at 254 nm due to the presence of aromatic rings. Apparently there are two sorption processes. The first one follows the same trend as the Langmuir isotherm up to 250 ppm. The second sorption process occurs after all the binding sites in the sediments have been occupied. Precipitation decreases as the pH is increased. Based on the sorption isotherm, humic substances apparently bind first to the binding sites of the sediments particles. Once all the binding sites have been occupied, other sorption processes may start to dominate. Sorption is affected by pH. Higher sorption is seen at low pH values. Increased precipitation at low pH values is probably due to the neutralization of surface charges of humic molecules making them agglomerate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A high-dimensional neural network potential for molecular dynamics simulations of condensed phase nickel and phase transitions

A high-dimensional neural network interatomic potential was developed and used in molecular dynamics simulations of condensed phase Ni and Ni systems with liquid–solid phase coexistence. The reference data set was generated by sampling the potential energy surface over a broad temperature-pressure domain using ab initio MD simulations to train a unified potential. Excellent agreement was achieved between bulk face-centered cubic nickel thermal expansion simulations and relevant experimental data. The same potential also yields accurate structures and diffusivities in the liquid state. The phase transition between liquid and solid phases was simulated using the two-phase interface method. The predicted melting point temperature is within a few kelvins of the literature value. Here, the general methodology could be applied to describe crystals with much more complex phase behaviors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Real-time observation of dynamic structure of liquid-vapor interface at nanometer resolution in electron irradiated sodium chloride crystals

The dynamics and structure of the liquid and vapor interface has remained elusive for decades due to the lack of an effective tool for directly visualization beyond micrometer resolution. Here, we designed a simple liquid-cell for encapsulating the liquid state of sodium for transmission electron microscopic (TEM) observation. The real-time dynamic structure of the liquid-vapor interface was imaged and videoed by TEM on the sample of electron irradiated sodium chloride (NaCl) crystals, a well-studied sample with low melting temperature and quantum super-shells of clusters. The nanometer resolution images exhibit the fine structures of the capillary waves, composed of first-time observed three zones of structures and features, i.e. flexible nanoscale fibers, nanoparticles/clusters, and a low-pressure area that sucks the nanoparticles from the liquid to the interface. Although the phenomenons were observed based on irradiated NaCl crystals, the similarities of the phenomenons to predictions suggest our real-time ovserved dynamic structure might be useful in validating long-debated theoretical models of the liquid-vapor interface, and enhancing our knowledge in understanding the non-equilibrium thermodynamics of the liquid-vapor interface to benefit future engineering designs in microfluidics.

36 MATERIALS SCIENCE↗

Improved Understanding of Zircaloy Hydrogen Pickup Mechanisms in BWRs. NSUF Report (Final Report)

Using an instrumented autoclave operating at 288°C and 1100 psi, electrical impedance spectroscopy (EIS) measurements were taken from three neutron irradiated fuel channel samples (Zircaloy-2 and Zircaloy-4). The three high priority fuel channel samples were tested at 288°C using a simulated PWR water with the AC frequency range extending down through 10 -4 Hz, with corresponding DC measurements to validate the resistance measurements. EIS measurements were also taken at room temperature using a simulated PWR water from four neutron irradiated fuel channel samples (Zircaloy-2 and Zircaloy-4). and four water rod samples (Zircaloy-2). EIS measurements were also performed on unirradiated Zircaloy-2 tubes that were previously oxidized in autoclaves at various temperatures for different time durations to obtain oxide layers of different thicknesses. These experiments proved to be more challenging than anticipated because of the small size of the samples, which required development of fixtures to allow valid testing of the materials, some of which are radioactive, under pressure and temperature. Equivalent circuits were used to model the data. Some samples resulted in Nyquist plots where the arcs were too close to each other resulting in the inability to separate the different oxide morphological thicknesses. Microstructural characterization in the form of optical microscopy, scanning electron microscopy and (scanning) transmission electron microscopy was performed to document the microstructural features of the oxidized Zr-2 and Zr-4 samples (oxide and metal/oxide interface) and to interpret the EIS results. At the start of this work, it was assumed that despite the laminar cracks and porosity visible in both optical and SEM, the oxide scale is dense near the metal, effectively preventing the water from contacting the metal directly. While it is generally accepted that the large laminar cracks pores allow the water to percolate into the oxide film, it is unknown just how deep it can go, and how interconnected is the porosity, which will dictate how much the porosity is connected electrically to the water within the oxide scale. The EIS results demonstrated that there is in fact a distribution of oxide thicknesses over the various samples, and within each material condition, that are communicating to the liquid. This is derived from the fact that Nyquist plots have an arc radius whose center point is often below the Z’ axis, implying that instead of a single oxide thickness, these oxides have a distribution of thicknesses. This distribution of thicknesses produces arcs that are not clearly separable in most of the samples.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LONG-TERM STABILITY TESTING RESULTS USING SURROGATES AND SORBENTS FOR SAVANNAH RIVER SITE ORGANIC AND AQUEOUS WASTESTREAMS - 10016

The U.S. Department of Energy (DOE) has tasked MSE Technology Applications, Inc. (MSE) with evaluating the long-term stability of various commercially available sorbent materials to solidify two organic surrogate wastestreams (both volatile and nonvolatile), a volatile organic surrogate with a residual aqueous phase, an aqueous surrogate, and an aqueous surrogate with a residual organic phase. The Savannah River Site (SRS) Legacy and F-Canyon plutonium/uranium extraction (PUREX) process waste surrogates constituted the volatile organic surrogates, and various oils constituted the nonvolatile organic surrogates. The aqueous surrogates included a rainwater surrogate and an aqueous organic surrogate. MSE also evaluated the PUREX surrogate with a residual aqueous component with and without aqueous type sorbent materials. Solidification of the various surrogate wastestreams listed above was performed from 2004 to 2006 at the MSE Test Facility located in Butte, Montana. This paper summarizes the comparison of the initial liquid release test (LRT) values with LRT results obtained during subsequent sampling events in an attempt to understand and define the long-term stability characteristics for the solidified wastestreams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fingerprints of a riming event on cloud radar Doppler spectra: observations and modeling

In this paper, Radar Doppler spectra measurements are exploited to study a riming event when precipitating ice from a seeder cloud sediment through a supercooled liquid water (SLW) layer. The focus is on the "golden sample" case study for this type of analysis based on observations collected during the deployment of the Atmospheric Radiation Measurement Program's (ARM) mobile facility AMF2 at Hyytiälä, Finland, during the Biogenic Aerosols – Effects on Clouds and Climate (BAECC) field campaign. The presented analysis of the height evolution of the radar Doppler spectra is a state-of-the-art retrieval with profiling cloud radars in SLW layers beyond the traditional use of spectral moments. Dynamical effects are considered by following the particle population evolution along slanted tracks that are caused by horizontal advection of the cloud under wind shear conditions. In the SLW layer, the identified liquid peak is used as an air motion tracer to correct the Doppler spectra for vertical air motion and the ice peak is used to study the radar profiles of rimed particles. A 1-D steady-state bin microphysical model is constrained using the SLW and air motion profiles and cloud top radar observations. The observed radar moment profiles of the rimed snow can be simulated reasonably well by the model, but not without making several assumptions about the ice particle concentration and the relative role of deposition and aggregation. In conclusion, this suggests that in situ observations of key ice properties are needed to complement the profiling radar observations before process-oriented studies can effectively evaluate ice microphysical parameterizations.

54 ENVIRONMENTAL SCIENCES↗

Seeing through walls at the nanoscale: Microwave microscopy of enclosed objects and processes in liquids

Here, noninvasive in situ nanoscale imaging in liquid environments is a current imperative in the analysis of delicate biomedical objects and electrochemical processes at reactive liquid–solid interfaces. Microwaves of a few gigahertz frequencies offer photons with energies of ≈10 μeV, which can affect neither electronic states nor chemical bonds in condensed matter. Here, we describe an implementation of scanning near-field microwave microscopy for imaging in liquids using ultrathin molecular impermeable membranes separating scanning probes from samples enclosed in environmental cells. We imaged a model electroplating reaction as well as individual live cells. Through a side-by-side comparison of the microwave imaging with scanning electron microscopy, we demonstrate the advantage of microwaves for artifact-free imaging.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: Analysis of human plasma and cerebrospinal fluid

Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

59 BASIC BIOLOGICAL SCIENCES↗

Radiochemical Separation and Quantification of Tritium in Metallic Radwastes Generated from CANDU Type NPP - 13279

As a destructive quantification method of {sup 3}H in low and intermediate level radwastes, bomb oxidation, sample oxidation, and wet oxidation methods have been introduced. These methods have some merits and demerits in the radiochemical separation of {sup 3}H radionuclides. That is, since the bomb oxidation and sample oxidation methods are techniques using heating at high temperature, the separation methods of the radionuclides are relatively simple. However, since {sup 3}H radionuclide has a property of being diffused deeply into the inside of metals, {sup 3}H which is distributed on the surface of the metals can only be extracted if the methods are applied. As an another separation method, the wet oxidation method makes {sup 3}H oxidized with an acidic solution, and extracted completely to an oxidized HTO compound. However, incomplete oxidized {sup 3}H compounds, which are produced by reactions of acidic solutions and metallic radwastes, can be released into the air. Thus, in this study, a wet oxidation method to extract and quantify the {sup 3}H radionuclide from metallic radwastes was established. In particular, a complete extraction method and complete oxidation method of incomplete chemical compounds of {sup 3}H using a Pt catalyst were studied. The radioactivity of {sup 3}H in metallic radwastes is extracted and measured using a wet oxidation method and liquid scintillation counter. Considering the surface dose rate of the sample, the appropriate size of the sample was determined and weighed, and a mixture of oxidants was added to a 200 ml round flask with 3 tubes. The flask was quickly connected to the distilling apparatus. 20 mL of 16 wt% H{sub 2}SO{sub 4} was given into the 200-ml round flask through a dropping funnel while under stirring and refluxing. After dropping, the temperature of the mixture was raised to 96 deg. C and the sample was leached and oxidized by refluxing for 3 hours. At that time, the incomplete oxidized {sup 3}H compounds were completely oxidized using the Pt catalysts and produced a stable HTO compound. After that, about a 20 ml solution was distilled in the separation apparatus, and the distillate was mixed with an ultimagold LLT as a cocktail solution. The solution in the vial was left standing for at least 24 hours. The radioactivity of {sup 3}H was counted directly using a liquid scintillation analyzer (Packard, 2500 TR/AB, Alpha and Beta Liquid Scintillation Analyzer). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress in Genetic Algorithm Fitting of X-Ray Fluorescence Data for Absorption Spectroscopy of Liquid Surfaces

X-ray fluorescence (XRF) spectroscopy of liquid surfaces is a promising approach to elemental analysis of forensic samples. Elements in the mixture can be identified from the XRF data because chemical elements are associated with unique spectra. This report describes progress in the development of automated identification of unknown mixtures of elements from XRF spectra using a genetic algorithm (GA). The XRF spectra are measured at the Advanced Photon Source (APS) at the liquid-liquid interface during solvent extraction process. The usage of the GA is demonstrated and future implementation for related problems are then discussed.

47 OTHER INSTRUMENTATION↗

Multimodal MSI in Conjunction with Broad Coverage Spatially Resolved MS2 Increases Confidence in Both Molecular Identification and Localization

One critical aspect of mass spectrometry imaging (MSI) is the need to con?dently identify detected analytes. While orthogonal tandem MS (e.g., LC-MS2) experiments from sample extracts can assist in annotating ions, the spatial information about these molecules is lost. Accordingly, this could cause mislead conclusions, especially in cases where isobaric species exhibit di?erent distributions within a sample. In this Technical Note, we employed a multimodal imaging approach, using matrix assisted laser desorption/ionization (MALDI)-MSI and liquid extraction surface analysis (LESA)-MS2I, to con?dently annotate and One critical aspect of mass spectrometry imaging (MSI) is the need to con?dently identify detected analytes. While orthogonal tandem MS (e.g., LC-MS2) experiments from sample extracts can assist in annotating ions, the spatial information about these molecules is lost. Accordingly, this could cause mislead conclusions, especially in cases where isobaric species exhibit di?erent distributions within a sample. In this Technical Note, we employed a multimodal imaging approach, using matrix assisted laser desorption/ionization (MALDI)-MSI and liquid extraction surface analysis (LESA)-MS2I, to con?dently annotate and localize a broad range of metabolites involved in a tripartite symbiosis system of moss, cyanobacteria, and fungus. We found that the combination of these two imaging modalities generated very congruent ion images, providing the link between highly accurate structural information onfered by LESA and high spatial resolution attainable by MALDI. These results demonstrate how this combined methodology could be very useful in di?erentiating metabolite routes in complex systems.

Velickovic, Dusan↗

Nanoparticles of La{sub 0.8}Ca{sub 0.2}Fe{sub 0.8}Ni{sub 0.2}O{sub 3-{delta}} perovskite for solid oxide fuel cell application

Polycrystalline samples of La{sub 0.8}Ca{sub 0.2}Fe{sub 0.8}Ni{sub 0.2}O{sub 3-{delta}} (LCFN) with perovskite type structure have been prepared by combustion, freeze drying, citrate-gel process and liquid mix method. The analysis of X-ray powder diffraction indicated that the samples were single phase and crystallized in an orthorhombic (space group, Pnma no. 62) structure. Transmission electron microscopy (TEM) analysis on the synthesized powder at 600 {sup o}C by liquid mix method showed clusters of 150 nm formed by nanoparticles of 20 nm. Electrochemical performance of LCFN cathodes, which are used for intermediate temperature solid oxide fuel cells, were investigated. The polarization resistance was studied using two different electrolytes: Y-doped zirconia (YSZ) and Sm-doped ceria (SDC). The dc four-probe measurement exhibits a total electrical conductivity, over 100 S cm{sup -1} at T {>=} 600 {sup o}C, pointing out that strontium can be substituted for the cheaper calcium cation without destroying the electrochemical properties. Experimental results indicate that nanoparticles have more advantages in terms of smaller particle size and better electrochemical performance.

36 MATERIALS SCIENCE↗

Methodology for the development of empirical models relating 13C NMR spectral features to fuel properties

Effective formulation of new gasoline or diesel fuels for internal combustion engines would benefit from the development of reliable models for predicting key fuel properties based on a set of molecular descriptors obtained from a single measurement. This is particularly relevant in the case of renewable fuels, where the available fuel sample quantity may be limited. In this work, we present a statistically-based methodology for building empirical models to predict multiple properties from one-dimensional 13C nuclear magnetic resonance (NMR) spectra measured on around 200 microliters of a liquid fuel. NMR spectra contain information about the molecular composition of a sample and the carbon types and molecular substructures therein. Our approach uses this information to build sparse, interpretable models, where the predicted properties are linked to specific molecular features. The approach takes into consideration the constrained nature of the features making up the one-dimensional NMR spectrum, which, after standardization, represent a relative fuel composition. We point to the limitations in interpretability that arise when building this type of empirical predictive model and suggest how these limitations may be diminished. Among the many properties important for maximizing engine performance and minimizing emissions, we build models that predict derived cetane number and distillation temperatures as these are of particular interest because of their links to fuel economy, drivability, and engine-out emissions. Results suggest that the properties of interest may be impacted by only a few of the 27 13C NMR regions represented in the data, pointing to new directions for further testing in the development of improved fuels.

predictive models, biofuels., NMR Analysis↗

Dramatic effect of oxide on measured liquid metal rheology

Liquid metals have traditionally been treated as Newtonian liquids, but several researchers have recently suggested that some metals may shear thin. While apparent shear thinning can be caused by surface oxidation, the reports of shear-thinning metals were investigated using cup and bob type rheometers, which are expected to only be weakly impacted by the surface contamination effects. We show here that even small amounts of oxide on the surface of liquid metals can cause dramatic changes to the measured viscosity of the sample. Using a Searle-type rotational rheometer, we measured the viscosity of eutectic gallium indium and tin in a low-oxygen environment. When either metal is slightly oxidized, the measured viscosity increases by orders of magnitude and the liquid displays erroneous shear-thinning behavior. When the oxide is removed via an active flux, the measured viscosity is Newtonian. The findings outlined here provide insight into the difficulties of measuring the viscosity of easily oxidized liquids and confirm that liquid metals are likely best described as Newtonian liquids at all measured shear rates.

36 MATERIALS SCIENCE↗

Quantifying replication through repeated analysis of UVM-A, a liquid reference material for cosmogenic 10 Be and 26 Al studies

In this study, in-situ produced cosmogenic nuclide sample preparation and analysis is a complicated, multi-step process with numerous possible sources of error, many of which have not been robustly quantified. Here, we use a liquid reference material (UVM-A) to test whether the analytic precision associated with individual isotopic ratios (n = 96) measured at two Accelerator Mass Spectrometry facilities (Lawrence Livermore National Laboratory and Purdue Rare Isotope Measurement Laboratory) accurately represents the range of values determined for aliquots prepared in a single laboratory over a period of five years. We find that 10 Be/ 9 Be ratios measured at the different accelerator facilities (n = 26 and n = 70) have statistically indistinguishable central tendencies, matching to within 0.1 %. Based on this large dataset, we suggest preliminary consensus values for UVM-A of 1.45 ± 0.06 x 10 -13 for 10 Be/ 9 Be (mean, one standard deviation, n = 96) and 4.47 ± 0.22 x 10 -13 for 26 Al/ 27 Al (mean, one standard deviation, n = 27). For both 10 Be/ 9 Be and 26 Al/ 27 Al, the relative standard deviations of the measured ratios are similar to the reported analytic uncertainties of sample measurement, suggesting that sample preparation introduced little if any additional scatter beyond the uncertainty of isotopic analysis. This dataset demonstrates that robust sample preparation and measurement can generate isotope ratio data reproducible at the level of counting statistics.

58 GEOSCIENCES↗

Quantitation of amiodarone and N-desethylamiodarone in single HepG2 cells by single-cell printing-liquid vortex capture-mass spectrometry

Quantitative measure of a drug and its associated metabolite(s) with single-cell resolution is often limited by sampling throughput or other compromises that limit broad use. Here, we demonstrate the use of single-cell printing-liquid vortex capture-mass spectrometry (SCP-LVC-MS) to quantitatively measure the intracellular concentrations of amiodarone (AMIO) and its metabolite, N-desethylamiodarone (NDEA), from thousands of single cells across several AMIO incubation concentrations ranging from 0 to 10 μM. Concentrations obtained by SCP-LVC-MS were validated through comparison with average assays and traditional measurement of cells in bulk. Average of SCP-LVC-MS measurements and aggregate vial collection assay the concentrations differed by < 5%. Both AMIO and NDEA had clear log-normal distributions with similar standard deviation of concentrations in the cell population. The mean of both AMIO and NDEA intracellular concentrations were positively correlated with AMIO incubation concentration, increasing from 0.026 to 0.520 and 0.0055 to 0.048 mM for AMIO and NDEA, respectively. The standard deviation of AMIO and NDEA log-normal distribution fits were relatively similar in value across incubation concentrations, 0.15–0.19 log 10 (mM), and exhibited a linear trend with respect to each other. The single cell-resolved conversion ratio of AMIO to NDEA increased with decreasing incubation concentration, 7 ± 2%, 18 ± 3%, and 20 ± 7% for 10.0, 1.0, and 0.1 μM AMIO incubation concentrations, respectively. Finally, association with simultaneously measured lipids had several ions with statistically significant difference in intensity but no clear correlations with AMIO intracellular content was observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗