Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

New approach in two-dimensional fluid modeling of edge plasma transport with high intermittency due to blobs and edge localized modes

A new approach is proposed to simulate intermittent, non-diffusive plasma transport (via blobs and filaments of edge localized modes (ELMs)) observed in the tokamak edge region within the framework of two-dimensional transport codes. This approach combines the inherently three-dimensional filamentary structures associated with an ensemble of blobs into a macro-blob in the two-dimensional poloidal cross-section and advects the macro-blob ballistically across the magnetic field, B. Intermittent transport is represented as a sequence of macro-blobs appropriately seeded in the edge plasma according to experimental statistics. In this case, the code is capable of reproducing both the long-scale temporal evolution of the background plasma and the fast spatiotemporal dynamics of blobs. We report the results from a two-dimensional edge plasma code modeling of a single macro-blob dynamics, and its interaction with initially stationary background plasma as well as with material surfaces. The mechanisms of edge plasma particle and energy losses from macro-blobs are analyzed. The effects of macro-blob sizes and advection velocity on edge plasma profiles are studied. The macro-blob impact on power loading and sputtering rates on the chamber wall and on inner and outer divertor plates is discussed. Temporal evolution of particle inventory of the edge plasma perturbed by macro-blobs is analyzed. Application of macro-blobs to ELM modeling is highlighted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of Differential Peptide Loading on Tandem Mass Tag-Based Proteomic and Phosphoproteomic Data Quality

Global and phosphoproteome profiling has demonstrated great utility for the analysis of clinical specimens. One major barrier to the broad clinical application of proteomic profiling is the large amount of biological material required, particularly for phosphoproteomics—currently on the order of 25 mg wet tissue weight, depending on tissue type. For hematopoietic cancers such as acute myeloid leukemia (AML), the sample requirement is in excess of 10 million (1E7) peripheral blood mononuclear cells (PBMCs). Throughout the course of a prospective study, this requirement will certainly exceed what is obtainable from many of the individual patients/timepoints. For this reason, we were interested in examining the impact of differential peptide loading across multiplex channels on proteomic data quality. Methods: To achieve this, we tested a range of channel loading amounts (20, 40, 100, 200, and 400 µg of tryptic peptides, or approximately the material obtainable from 5E5, 1E6, 2.5E6, 5E6, and 1E7 AML patient cells) to assess proteome coverage, quantification reproducibility and accuracy in experiments utilizing isobaric tandem mass tag (TMT) labeling. As expected, we found that fewer missing values are observed in TMT channels with higher peptide loading amounts compared to those with lower loading. Moreover, channels with lower loading amounts have greater quantitative variability than channels with higher loading amounts. Statistical analysis of the differences in means among the five loading groups showed that the 20 µg loading group was significantly different from the 400 µg loading group. However, no significant differences were detected among the 40, 100, 200 and 400 µg loading groups. Conclusions: These assessment data demonstrate the practical limits of loading differential quantities of peptides across channels in TMT multiplexes, and provide a basis for designing the optimal clinical proteomics study when specimen quantities are limited.

59 BASIC BIOLOGICAL SCIENCES↗

A Burnup Credit Approach for Margin Estimation of Loaded Boiling Water Reactor Canisters in UNF-ST&DARDS

This paper discusses the modeling approach applied in the Used Nuclear Fuel Storage, Transportation, & Disposal Analysis Resource and Data System (UNF-ST&DARDS) to take credit for the reduced reactivity associated with the burnup of boiling water reactor (BWR) fuel for canister-specific as loaded criticality analysis. Burnup credit is routinely used for the analysis of pressurized water reactor (PWR) spent nuclear fuel (SNF) storage (wet), transportation, and disposal. The fresh fuel assumption has historically been applied to BWR SNF criticality analyses for dry storage and transportation, and the peak reactivity method of burnup credit has been applied to pool storage. The fresh fuel assumption ignores the credit for gadolinium burnable absorbers in BWR fuel, as well as the burnup of the fuel, and is therefore conservative. This work employs the framework traditionally used for PWR burnup credit analyses and applies available data and recently published regulatory guidance to justify a new approach to model the as-loaded burnup and enrichment of SNF assemblies in currently loaded dry casks. The following features of this criticality analysis approach are presented in this paper: (1) selection of axial burnup profiles for BWR fuel from publicly available sources using methods derived from recently published research, (2) justification of the selected axial burnup profiles as relevant to all types of BWR fuel, (3) justification for modeling the fuel assemblies with a uniform axial and radial enrichment, and (4) justification for modeling the axial void profile and control blade insertion during depletion. This analysis approach was used to evaluate 153 already-loaded BWR casks at 8 sites as a function of time in UNF ST&DARDS. Finally, the results of the as-loaded criticality safety margin assessments are presented. The results show the k eff calculated for storage and transportation cases range from 0.71 to 0.83, and the eigenvalues calculated for the disposal cases range from 0.85 to 1.03, though the highest cases are dominated by very limiting hypothetical damaged fuel assumptions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A burnup credit approach for margin estimation of loaded boiling water reactor canisters in UNF-ST-DARDS

This paper discusses the modeling approach applied in the Used Nuclear Fuel Storage, Transportation, and Disposal Analysis Resource and Data System (UNF-ST-DARDS) to take credit for the reduced reactivity associated with the burnup of boiling water reactor (BWR) fuel for canister-specific as-loaded criticality analysis. Burnup credit is routinely used for the analysis of pressurized water reactor (PWR) spent nuclear fuel (SNF) storage (wet), transportation, and disposal. The fresh fuel assumption has historically been applied to BWR SNF criticality analyses for dry storage and transportation, and the peak reactivity method of burnup credit has been applied to pool storage. The fresh fuel assumption ignores the credit for gadolinium burnable absorbers in BWR fuel, as well as the burnup of the fuel, and is therefore conservative. This work employs the framework traditionally used for PWR burnup credit analyses and applies available data and recently published regulatory guidance to justify a new approach to model the as-loaded burnup and enrichment of SNF assemblies in currently loaded dry casks. The following features of this criticality analysis approach are presented in this paper: (1- selection of axial burnup profiles for BWR fuel from publicly available sources using methods derived from recently published research, (2- justification of the selected axial burnup profiles as relevant to all types of BWR fuel, (3- justification for modeling the fuel assemblies with a uniform axial and radial enrichment, and (4- justification for modeling the axial void profile and control blade insertion during depletion. This analysis approach was used to evaluate 153 already-loaded BWR casks at 8 sites as a function of time in UNF-ST-DARDS. Finally, the results of the as-loaded criticality safety margin assessments are presented. The results show the k{sub eff} calculated for storage and transportation cases range from 0.71 to 0.83, and the eigenvalues calculated for the disposal cases range from 0.85 to 1.03, though the highest cases are dominated by very limiting hypothetical damaged fuel assumptions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reversal of asymmetry of x-ray peak profiles from individual grains during a strain path change.

X-ray peak profiles are measured from individual bulk grains during tensile deformation. Two differently oriented copper samples pre-deformed in tension show the expected peak profile asymmetry caused by intra-grain stresses. One of the samples is oriented to achieve a significant change of the intra-grain stresses during in situ tensile loading and this is observed as a reversal of the sign of the peak profile asymmetry.

36 MATERIALS SCIENCE↗

Staged OMB for Modular Gasifier/Burner

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0031506. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UK CAER) (Recipient) has developed a staged opposed multi-burner (OMB) gasifier, scaled down from a commercial gasification technology to utilize coal slurry as feed for the high-temperature gasification. The project involved the design, fabrication, commissioning, parametric testing, and performance validation of the entrained gasifier with multiple burners to narrow the major near-term technical gaps that impede the application of small-size gasification by modularizing the system. Project results verified the UK CAER approach to address the major technical challenges on the gasification modularization for a distributed application at a small scale of 1-5 MWe, while maintaining advantages in cost and flexibility, which include: 1) a cost-effective burner configuration to provide high flexibility in both load and fuel feed; 2) the modularized staged-OMB to provide better gasification performance such as a desired temperature profile, better fuel conversion, better gasification efficiency, and long lifetimes of the refractory wall and burners; and 3) load control simply through changing the number of burners firing. UK CAER’s staged gasifier configuration, fuel blend performance, and economic evaluation shows promise, as summarized in this report, as an effective means for improved gasification efficiency with reduced operation cost and process complexity.

01 COAL, LIGNITE, AND PEAT↗

Development of a Pressure Box to Evaluate Reusable-Launch-Vehicle Cryogenic-Tank Panels

A cryogenic pressure-box test machine has been designed and is being developed to test full-scale reusable launch vehicle cryogenic-tank panels. This machine is equipped with an internal pressurization system, a cryogenic cooling system, and a heating system to simulate the mechanical and thermal loading conditions that are representative of a reusable launch vehicle mission profile. The cryogenic cooling system uses liquid helium and liquid nitrogen to simulate liquid hydrogen and liquid oxygen tank internal temperatures. A quartz lamp heating system is used for heating the external surface of the test panels to simulate cryogenic-tank external surface temperatures during re-entry of the launch vehicle. The pressurization system uses gaseous helium and is designed to be controlled independently of the cooling system. The tensile loads in the axial direction of the test panel are simulated by means of hydraulic actuators and a load control system. The hoop loads in the test panel are reacted by load-calibrated turnbuckles attached to the skin and frame elements of the test panel. The load distribution in the skin and frames can be adjusted to correspond to the tank structure by using these turnbuckles. The seal between the test panel and the cryogenic pressure box is made from a reinforced Teflon material which can withstand pressures greater than 52 psig at cryogenic temperatures. Analytical results and tests on prototype test components indicate that most of the cryogenic-tank loading conditions that occur in flight can be simulated in the cryogenic pressure-box test machine.

Ambur, Damodar R.↗

Power allocation by load aggregator with heterogeneous loads using weighted projection

With the recently increasing adoption of transactive energy markets, the role of a load aggregator is becoming increasingly important. Among the many tasks of an aggregator, the task of managing the electricity consumption among a group of grid-interactive efficient buildings according to the demand on the grid is taken up. Specifically, here, the task of allocating a certain amount of power among the participating customers while respecting their preferences and comfort is considered. Modeling this as an aggregate flexibility, the virtual battery conditions that are employed to verify the feasibility of a candidate power profile are derived. A feasible power profile, when allocated, satisfies specified comfort bands. To determine the ideal power requirement of the loads, the model-free control method is employed. The feasible power profile is allocated by embedding the customers’ preferences through weights, posing the power constraint as a hyperplane, and employing a weighted projection from the ideal power requirements onto the constraint plane to solve the considered task. The proposed method is computationally efficient and scalable to any number of heterogeneous thermostatically controlled loads in buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Noncontacting Laser Inspection System for Dimensional Profiling of Space Application Thermal Barriers

A noncontacting, two-dimensional (2-D) laser inspection system has been designed and implemented to dimensionally profile thermal barriers being developed for space vehicle applications. In a vehicle as-installed state, thermal barriers are commonly compressed between load sensitive thermal protection system (TPS) panels to prevent hot gas ingestion through the panel interface during flight. Loads required to compress the thermal barriers are functions of their construction, as well as their dimensional characteristics relative to the gaps in which they are installed. Excessive loads during a mission could damage surrounding TPS panels and have catastrophic consequences. As such, accurate dimensional profiling of thermal barriers prior to use is important. Due to the compliant nature of the thermal barriers, traditional contact measurement techniques (e.g., calipers and micrometers) are subjective and introduce significant error and variability into collected dimensional data. Implementation of a laser inspection system significantly enhanced the method by which thermal barriers are dimensionally profiled, and improved the accuracy and repeatability of collected data. A statistical design of experiments study comparing laser inspection and manual caliper measurement techniques verified these findings.

Taylor, Shawn C.↗

Field Test Protocol: Standard Internal Load Generation in Unoccupied Test Homes

This document describes a simple and general way to generate House Simulation Protocol (HSP)-consistent internal sensible and latent loads in unoccupied homes. It is newly updated based on recent experience, and provides instructions on how to calculate and set up the operational profiles in unoccupied homes. The document is split into two sections: how to calculate the internal load magnitudeand schedule, and then what tools and methods should be used to generate those internal loads to achieve research goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Test Protocol: Standard Internal Load Generation for Unoccupied Test Homes

This document describes a simple and general way to generate House Simulation Protocol (HSP)-consistent internal sensible and latent loads in unoccupied homes. It is newly updated based on recent experience, and provides instructions on how to calculate and set up the operational profiles in unoccupied homes. The document is split into two sections: how to calculate the internal load magnitude and schedule, and then what tools and methods should be used to generate those internal loads to achieve research goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Performance of Commercial Building Load Flexibility Using Model Predictive Control

Model Predictive Control (MPC) applied to buildings is starting to see some commercial adoption by companies. However, it is hard to estimate if relative energy cost savings are enough to justify the cost of MPC implementation with few reported demonstrations. In small commercial and residential buildings, a one size-fits-all solution can help reduce implementation costs, while in very large buildings or districts the potential energy cost savings magnitude can cover more tailored solutions. This estimation becomes harder for medium to large commercial buildings, where a one-size-fits-all solution cannot be adopted and potential energy cost savings might not be sufficient to cover a tailored solution. Therefore, value propositions in addition to energy efficiency alone can make MPC technology more attractive through additional energy cost savings. One such value proposition is load shifting in response to dynamic electricity prices. On this aspect, MPC is a key technology to unlock building thermal mass for energy flexibility in response to electric grid conditions. This study shows the experimental results of MPC control of an office building in Berkeley, where different dynamic electricity price profiles were used in the MPC objective function to shift the building load and to calculate hypothetical electricity costs. Results show potential 50% cost savings with respect to the existing controller with the dynamic price scenario.

Zanetti, Ettore↗

Analysis shear wave velocity structure obtained from surface wave methods in Bornova, Izmir

Properties of the soil from the bedrock is necessary to describe accurately and reliably for the reduction of earthquake damage. Because seismic waves change their amplitude and frequency content owing to acoustic impedance difference between soil and bedrock. Firstly, shear wave velocity and depth information of layers on bedrock is needed to detect this changing. Shear wave velocity can be obtained using inversion of Rayleigh wave dispersion curves obtained from surface wave methods (MASW- the Multichannel Analysis of Surface Waves, ReMi-Refraction Microtremor, SPAC-Spatial Autocorrelation). While research depth is limeted in active source study, a passive source methods are utilized for deep depth which is not reached using active source methods. ReMi method is used to determine layer thickness and velocity up to 100 m using seismic refraction measurement systems.The research carried out up to desired depth depending on radius using SPAC which is utilized easily in conditions that district using of seismic studies in the city. Vs profiles which are required to calculate deformations in under static and dynamic loads can be obtained with high resolution using combining rayleigh wave dispersion curve obtained from active and passive source methods. In the this study, Surface waves data were collected using the measurements of MASW, ReMi and SPAC at the İzmir Bornova region. Dispersion curves obtained from surface wave methods were combined in wide frequency band and Vs-depth profiles were obtained using inversion. Reliability of the resulting soil profiles were provided by comparison with theoretical transfer function obtained from soil paremeters and observed soil transfer function from Nakamura technique and by examination of fitting between these functions. Vs values are changed between 200-830 m/s and engineering bedrock (Vs>760 m/s) depth is approximately 150 m.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laminarization of Turbulent Boundary Layer on Flexible and Rigid Surfaces

An investigation of the control of turbulent boundary layer flow over flexible and rigid surfaces downstream of a concave-convex geometry has been made. The concave-convex curvature induces centrifugal forces and a pressure gradient on the growth of the turbulent boundary layer. The favorable gradient is not sufficient to overcome the unfavorable; thus, the net effect is a destabilizing, of the flow into Gortler instabilities. This study shows that control of the turbulent boundary layer and structural loading can be successfully achieved by using localized surface heating because the subsequent cooling and geometrical shaping downstream over a favorable pressure gradient is effective in laminarization of the turbulence. Wires embedded in a thermally insulated substrate provide surface heating. The laminarized velocity profile adjusts to a lower Reynolds number, and the structure responds to a lower loading. In the laminarization, the turbulent energy is dissipated by molecular transport by both viscous and conductivity mechanisms. Laminarization reduces spanwise vorticity because of the longitudinal cooling gradient of the sublayer profile. The results demonstrate that the curvature-induced mean pressure gradient enhances the receptivity of the flow to localized surface heating, a potentially viable mechanism to laminarize turbulent boundary layer flow; thus, the flow reduces the response of the flexible structure and the resultant sound radiation.

Maestrello, Lucio↗

Results of the Updated NASA Kennedy Space Center 50-MHz Doppler Radar Wind Profiler Operational Acceptance Test

We present here the methodology and results of the Operational Acceptance Test (OAT) performed on the new Kennedy Space Center (KSC) 50-MHz Doppler Radar Wind Profiler (DRWP). On day-of-launch (DOL), space launch vehicle operators have used data from the DRWP to invalidate winds in prelaunch loads and trajectory assessments due to the DRWP's capability to quickly identify changes in the wind profile within a rapidly-changing wind environment. The previous DRWP has been replaced with a completely new system, which needs to undergo certification testing before being accepted for use in range operations. The new DRWP replaces the previous three-beam system made of coaxial cables and a copper wire ground plane with a four-beam system that uses Yagi antennae with enhanced beam steering capability. In addition, the new system contains updated user interface software while maintaining the same general capability as the previous system. The new DRWP continues to use the Median Filter First Guess (MFFG) algorithm to generate a wind profile from Doppler spectra at each range gate. DeTect (2015) contains further details on the upgrade. The OAT is a short-term test designed so that end users can utilize the new DRWP in a similar manner to the previous DRWP during mission operations at the Eastern Range in the midst of a long-term certification process. This paper describes the Marshall Space Flight Center Natural Environments Branch's (MSFC NE's) analyses to verify the quality and accuracy of the DRWP's meteorological data output as compared to the previous DRWP. Ultimately, each launch vehicle program has the responsibility to certify the system for their own use.

Barbre', Robert E., Jr.↗

Mock Truss-Braced Wing Loads Calibration Research Utilizing Fiber-Optic Sensors

In support of the National Aeronautics and Space Administration Advanced Air Transonic Transport Truss-Braced Wing structural research, the Armstrong Flight Research Center Flight Loads Laboratory is performing pathfinder tests on a small, scaled test article (dubbed the mock Truss-Braced Wing) to study the application of a loads calibration on a truss-braced wing structure. The addition of a truss to the wing structure, as opposed to a purely cantilever beam setup, changes the strain-gage-based loads calibration techniques. In a truss-braced configuration, the internal shear and moments, inboard of the truss-wing connection, are not directly representative of the external aerodynamic loading as is the case for a traditional cantilever configuration. A 3-axis load cell was used at the wing-to-strut interface to estimate the load sharing between the two structural members. Crosstalk within the 3-axis load cell is added to the measurement uncertainties of the calibration effort, and the results, including crosstalk uncertainties, are presented. The calibration tests presented in this report are used as a pathfinder for developing an understanding how to perform loads calibration on a truss-braced wing structural configuration. The use of distributed fiber-optic strain sensors is leveraged to provide a near-full-span strain profile along the leading and trailing edge of the wing structure for strain-based loads calibration.

Francisco Peña↗

Bacterial Membranes Are More Perturbed by the Asymmetric Versus Symmetric Loading of Amphiphilic Molecules

Characterizing the biophysical properties of bacterial membranes is critical for understanding the protective nature of the microbial envelope, interaction of biological membranes with exogenous materials, and designing new antibacterial agents. Presented here are molecular dynamics simulations for two cationic quaternary ammonium compounds, and the anionic and nonionic form of a fatty acid molecule interacting with a Staphylococcus aureus bacterial inner membrane. The effect of the tested materials on the properties of the model membranes are evaluated with respect to various structural properties such as the lateral pressure profile, lipid tail order parameter, and the bilayer’s electrostatic potential. Conducting asymmetric loading of molecules in only one leaflet, it was observed that anionic and cationic amphiphiles have a large impact on the Staphylococcus aureus membrane’s electrostatic potential and lateral pressure profile as compared to a symmetric distribution. Nonintuitively, we find that the cationic and anionic molecules induce a similar change in the electrostatic potential, which points to the complexity of membrane interfaces, and how asymmetry can induce biophysical consequences. Finally, we link changes in membrane structure to the rate of electroporation for the membranes, and again find a crucial impact of introducing asymmetry to the system. Understanding these physical mechanisms provides critical insights and viable pathways for the rational design of membrane-active molecules, where controlling the localization is key.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of jet decay rate on jet induced loads on a flat plate

Experimental modelling of the interaction between a jet and an aircraft wing or fuselage in VTOL aircraft was undertaken using a cold jet exiting perpendicular to a flat plate in a uniform cross-flow. Effects of jet decay rate and jet-to-cross-flow velocity ratio, R, on the induced load distribution were investigated. Jet decay rate was increased by using cylindrical centerbodies submerged in the jet nozzle, which caused nonuniform initial jet velocity profiles. Quicker jet decay rate, corresponding to the presence of a centerbody, resulted in as much as 50% reduction in the induced pressure loads on the plate. This has implications in interpretation of results from earlier VTOL model studies of jet induced loads, where the jets have often had relatively slow decay rates due to uniform initial velocity profiles

Kuhlman, J. M.↗