Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROSCOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Large area direct-write focused ion-beam lithography with dual-beam microscope.

The authors have investigated the performance of focused ion-beam (FIB) direct-write lithography for large area (multiple write-field) patterning in an FEI Nova Nanolab 600 dual-beam microscope. Their system is configured with a 100 nm resolution X-Y stage and a RAITH ELPHY LITHOGRAPHY control interface, with its own integrated 16 bit DAC pattern generator and software. Key issues with regard to configuration, process parameters, and procedures have been addressed. Characterization of stitching errors, pattern repeatability, and drift were performed. Offset lithography (multiple exposures with offset write fields) and in-field registration marks were evaluated for correcting stitching errors, and a test microfluidic device covering an area of 1 x 1.4 mm{sup 2} was successfully fabricated. The authors found that by using a combination of offset lithography and in-field registration mark correction methods, the stitching errors can be kept well below 100 nm. They also found that due to higher beam deflection speed provided by the electrostatic scanning in FIB systems versus the wide-spread electron-beam systems with electromagnetic scanning, FIB lithography can be just as fast as electron-beam lithography for typical mill depths down to about 200-500 nm (material dependent). This opens the door for a large suite of applications for materials where pattern transfer is difficult or impossible by reactive methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Calibration of tip and sample temperature of a scanning tunneling microscope using a superconductive sample

The temperature of the electrodes is a crucial parameter in virtually all tunneling experiments. The temperature not only controls the thermodynamic state of the electrodes but also causes thermal broadening, which limits the energy resolution. Unfortunately, the construction of many scanning tunneling microscopes inherits a weak thermal link between tip and sample in order to make one side movable. Such, the temperature of that electrode is badly defined. Here, the authors present a procedure to calibrate the tip temperature by very simple means. The authors use a superconducting sample (Nb) and a standard tip made from W. Due to the asymmetry in the density of states of the superconductor (SC)—normal metal (NM) tunneling junction, the SC temperature controls predominantly the density of states while the NM controls the thermal smearing. By numerically simulating the I-V curves and numerically optimizing the tip temperature and the SC gap width, the tip temperature can be accurately deduced if the sample temperature is known or measureable. In our case, the temperature dependence of the SC gap may serve as a temperature sensor, leading to an accurate NM temperature even if the SC temperature is unknown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Growth of microscopic cones on titanium cathodes of sputter-ion pumps driven by sorption of large argon quantities

Microscopic cones have been observed on titanium cathodes of sputter-ion pumps (SIPs) after pump operation. The cones were studied by means of scanning electron microscopy and energy dispersive x-ray analysis. Size and morphology of these cones are clearly correlated with the nature and the relative amount of each gas species pumped by each SIP during its working life. In particular, their growth was found to be fed by sputtering mechanisms, mostly during Ar pumping, and to be driven by the electromagnetic field applied to the Penning cells of each SIP. Experimental findings suggest that the formation and extent of such conic structures on cathode surfaces might play a leading role in the onset of phenomena typically related to the functioning of SIPs, e.g., the so-called argon instability.

36 MATERIALS SCIENCE↗

Atomic precision imaging with an on-chip scanning tunneling microscope integrated into a commercial ultrahigh vacuum STM system

In this article, we replace the Z axis of the piezotube of a conventional Ultrahigh-Vacuum (UHV) Scanning Tunneling Microscope (STM) with a one-degree-of-freedom Microelectromechanical-System (MEMS) nanopositioner. As a result, a hybrid system is realized in which motions in the XY plane are carried out by the piezotube, while the MEMS device performs the Z-axis positioning with a smaller footprint and higher sensitivity. With the proposed system and a feedback loop, STM imaging is conducted on an H-passivated Si (100)-2×1 sample in a UHV condition, demonstrating that this on-chip STM is conducive to atomic precision scanning tunneling microscopy.

Engineering↗

Surface deposition of nanometer scale carbon structures on Bi 2 Sr 2 CaCu 2 O 8+δ using a low-cost scanning electron microscope

In this work, we investigate optically active nanostructures on Bi 2 Sr 2 CaCu 2 O 8+δ (BSCCO). The nanostructures are constructed from carbon nanocrystals formed using the electron beam of a scanning electron microscope to locally decompose residual hydrocarbons at the BSCCO surface. Atomic force microscopy is used to characterize the dimensions of these structures as a function of beam exposure time. This technique has been used to induce localized intercalation to form carbon nanoparticles up to tens of nanometers into a variety of 2D materials. Cross-sectional scanning transmission electron microscopy in BSCCO shows the presence of these carbon deposits on the surface, but there is no evidence they penetrate into the BSCCO substrate. Therefore, this technique is not suitable for localized intercalation in BSCCO, and it does have promise as a cost-effective approach to pattern nanometer scale etch stops.

2D materials↗

Binary pseudorandom test standard to determine the modulation transfer function of optical microscopes

This work reports on the development of a binary pseudo-random test sample optimized to calibrate the MTF of optical microscopes. The sample consists of a number of 1-D and 2-D patterns, with different minimum sizes of spatial artifacts from 300 nm to 2 microns. We describe the mathematical background, fabrication process, data acquisition and analysis procedure to return spatial frequency based instrument calibration. We show that the developed samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional super line-localization in low signal-to-noise microscope images via prior-apprised unsupervised learning (PAUL)

Biological processes such as processive enzyme turnover and intracellular cargo tracking involve the dynamic motion of a small "article" along a curvilinear biopolymer track. To understand these processes that occur across multiple length and time scales, one must acquire both the trajectory of the particle and the position of the track along which it moves, possibly by combining high-resolution single-particle tracking with conventional microscopy. Yet, usually there is a significant resolution mismatch between these modalities: while the tracked particle is localized with a precision of 10 nm, the image of the surroundings is limited by optical difraction, with 200 nm lateral and 500 nm axial resolutions. Compared to the particle's trajectory, the surrounding curvilinear structure appears as a blurred and noisy image. This disparity in the spatial resolutions of the particle trajectory and the surrounding curvilinear structure image makes data reconstruction, as well as interpretation, particularly challenging. Analysis is further complicated when the curvilinear structures are oriented arbitrarily in 3D space. Here, we present a prior-apprised unsupervised learning (PAUL) approach to extract information from 3D images where the underlying features resemble a curved line such as a filament or microtubule. This three-stage framework starts with a Hessian-based feature enhancement, which is followed by feature registration, where local line segments are detected on repetitively sampled subimage tiles. In the final stage, statistical learning, segments are clustered based on their geometric relationships. Principal curves are then approximated from each segment group via statistical tools including principal component analysis, bootstrap and kernel transformation. This procedure is characterized on simulated images, where sub-voxel medium deviations from true curves have been achieved. The 3D PAUL approach has also been implemented for successful line localization in experimental 3D images of gold nanowires obtained using a multifocal microscope. Lastly, this work not only bridges the resolution gap between two microscopy modalities, but also allows us to conduct 3D super line-localization imaging experiments, without using super-resolution techniques.

42 ENGINEERING↗

SU-E-T-293: Dosimetric Analysis of Microscopic Disease in SBRT for Lung Cancers

Purpose: To evaluate the dosimetry of microscopic disease (MD) region of lung cancer in stereotactic body radiation therapy (SBRT). Methods: For simplicity, we assume organ moves along one dimension. The probability distribution function of tumor position was calculated according to the breathing cycle. The dose to the MD region was obtained through accumulating the treatment planning system calculated doses at different positions in a breathing cycle. A phantom experiment was then conducted to validate the calculated results using a motion phantom (The CIRS ‘Dynamic’ Thorax Phantom). The simulated breathing pattern used a cos4(x) curve with an amplitude of 10mm. A 3-D conformal 7-field plan with 6X energy was created and the dose was calculated in the average intensity projection (AIP) simulation CT images. Both films (EBT2) and optically stimulated luminescence (OSL) detectors were inserted in the target of the phantom to measure the dose during radiation delivery (Varian Truebeam) and results were compared to planning dose parameters. Results: The Gamma analysis (3%/3mm) between measured dose using EBT2 film and calculated dose using AIP was 80.5%, indicating substantial dosimetric differences. While the Gamma analysis (3%/3mm) between measured dose using EBT2 and accumulated dose using 4D-CT was 98.9%, indicating the necessity of dose accumulation using 4D-CT. The measured doses using OSL and theoretically calculated doses using probability distribution function at the corresponding position were comparable. Conclusion: Use of static dose calculation in the treatment planning system could substantially underestimate the actually delivered dose in the MD region for a moving target. Funding Supported by NSFC, No.81372436.

60 APPLIED LIFE SCIENCES↗

SU-E-T-544: Microscopic Dose Enhancement of Gold Nanoparticles in Water for Proton Therapy: A Simulation Study

Purpose: To quantify the microscopic dose and linear energy transfer (LET) enhancement of gold nanoparticles (GNPs) in water for proton therapy. Methods: The GEANT4 toolkit (version 10) with low energy electromagnetic classes was used to create a series of simulations where three radii (r=5, 20, 100 nm) of gold nanoparticles (GNPs) were irradiated with 5 × 106 80 MeV protons. A cubic detector (10 × 10 × 10 um, divided in 25 × 25 × 25 voxels) were placed in a water phantom where the GNP rests in the center. The size of incident proton beam was set to be same as the GNPs and perpendicularly aiming to the target. Dose deposited to each voxel were recorded to calculate the overall deposited dose and the dose-averaged LET. The emitted secondary electron spectra were also collected in a spherical customized scorer (radius = 150 nm). Results: The average dose from a single GNP in a cubic water phantom was increased by 0.12 %, 1.12% and 2.3% and the mean dose-averaged LET was increased by 5.87% and 27.67% and 0.31% for GNP radius of 5 nm, 20 nm and 100 nm, respectively. Conclusion: The dose enhancement effect from the presence of a single GNP was qualified in a water phantom. A significant increase in the mean dose-averaged LET was found for 20 nm GNP.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-H-CAMPUS-TeP3-05: Evaluation of the Microscopic Dose Enhancement in the Nanoparticle-Enhanced Auger Therapy

Purpose: The aim of this study is to apply Monte Carlo simulations to investigate the nanoparticle dose enhancement for Auger therapy. Methods: Two nanoparticle fabrications were considered: nanoshell and nanosphere. In the first step, a single nanoparticle was irradiated with Auger emitters. The electrons were scored in a phase space at the outer surface of the nanoparticle with Geant4-Penelope. In the second step, the previously recorded phase space was used as a source and placed at the center of a cell-size water phantom. The nanoscale dose was evaluated in water around the nanoparticle with Geant4-DNA. The dose enhancement factor (DEF) is defined as the ratio of doses with and without nanoparticles. The nanoparticles were replaced by corresponding water nanoparticle with the same size and volume source which represents typical situation of Auger emitters without nanoparticle. Various sizes/materials of nanoparticles and isotopes were considered. Results: Nanoshell - Microscopic dose was increased up to 130% at 20 – 100 nm distances from the surface of Au-{sup 125}I nanoshell. However, dose at less than 20 nm distance was reduced due to absorbed low energy electrons in gold nanoshell. The amounts and regions of the dose enhancement were dependent on nanoshell size, materials, and isotopes. Nanosphere - The increased amounts of electrons up to 300% and reduced average energy with nanosphere were observed compared with water nanoparticle. We observed localized dose enhancement (up to a factor 3.6) in the immediate vicinity (< 50 nm) of Au-{sup 125} I nanosphere. The dose enhancement patterns vary according to nanosphere sizes and isotopes. Conclusion: We conclude that Auger therapy with nanoparticles can lead to change of electron energy spectrum and dose enhancements at certain range. The dose enhancement patterns vary according to nanoparticle sizes, materials, and isotopes. This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIP: Ministry of Science, ICT and Future Planning) (No. NRF-2013M2B2B1075776)

60 APPLIED LIFE SCIENCES↗

Microscopic theory of scattering of weak electromagnetic radiation by a dense ensemble of ultracold atoms

Based on the developed quantum microscopic theory, the interaction of weak electromagnetic radiation with dense ultracold atomic clouds is described in detail. The differential and total cooperative scattering cross sections are calculated for monochromatic radiation as particular examples of application of the general theory. The angular, spectral, and polarization properties of scattered light are determined. The dependence of these quantities on the sample size and concentration of atoms is studied and the influence of collective effects is analyzed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Microscopic K{sup +}-nucleus optical potential and calculations of differential elastic-scattering cross sections and total reaction cross sections

The differential elastic-scattering cross sections and the total reaction cross sections for the interaction of K{sup +} mesons with {sup 12}C and {sup 40}Ca nuclei at beam momenta of 0.635, 0.715, and 0.8 GeV/c are calculated. The microscopic optical potential derived in the high-energy approximation is used in these calculations. It is determined by the amplitude for kaon-nucleon scattering and the density distribution of pointlike nucleons of the target nucleus. In the high-energy approximation, the Klein-Gordon-Fock equation reduces to the form of the Schroedinger equation. It is shown that small distinctions between the reduction methods do not lead to significant changes in differential elastic-scattering cross sections, but the effects of relativization as such are quite large. Good agreement with experimental data on elastic K{sup +}A scattering is attained. The total reaction cross sections can be described upon adding, to the volume potential, a term that takes the form of its derivative and which has a maximum at the periphery, its contribution being fitted to experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A study on the Fresnel diffraction of {sup 6}He by means of different microscopic density distributions

The elastic scattering of the halo nucleus {sup 6}He from heavy targets such as {sup 197}Au and {sup 208}Pb has been investigated in order to explain the Coulomb rainbow peak due to the Fresnel-type diffraction observed in the experimental data. In order to examine the role of nuclear potential to describe {sup 6}He + {sup 197}Au and {sup 6}He + {sup 208}Pb systems, we have used the no-core shell model, few-body and Gaussian-shaped density distributions at various energies. The microscopic real parts of the complex nuclear potential have been obtained by using the double-folding model for each of the density distribution and the phenomenological imaginary potentials have been taken as the standard Woods-Saxon shape. We have observed that fewbody and Gaussian-shaped density distributions have given standard Fresnel-type diffraction results, a classical scattering pattern with Coulomb rainbow peak whereas the nuclear potential obtained by using the no-core shell-model density distribution has provided the reduction at Fresnel peak and has given more consistent results with the experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A microscopic study on shape transition and shape coexistence in superdeformed nuclei

Superdeformed nuclei at high-spin states in several mass regions are investigated within a microscopic approach using cranked Nilsson-Strutinsky formalism to explore the equilibrium deformations in the ground state and their evolution with spin. Shape transition from normal deformed to superdeformed states with increasing spin is studied and a clear picture of shape coexistence is provided. Detailed information on spin, rotational energy, dynamical moment of inertia, and rotational frequency of superdeformed rotational bands is presented and the general features of superdeformed bands in certain mass regions are outlined. Rotational energy and dynamical moment of inertia are compared with available experimental data and the impact of temperature and pairing on superdeformed configuration are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscopic study of the string breaking in QCD

Theory of strong decays defines in addition to decay widths also the channel coupling and the mass shifts of the levels above the decay thresholds. In the standard decay models of the {sup 3}P{sub 0} type the decay vertex is taken to be a phenomenological constant {gamma} and such a choice leads to large mass shifts of all meson levels due to real and virtual decays, the latter giving a divergent contribution. Here we show that taking the microscopic details of decay vertex into account, one obtains new string width effect coefficient, which strongly suppresses virtual decay contribution. In addition for a realistic space structure of the decay vertex of highly excited states, the decay matrix elements appear to be strongly different from those, where the constant {gamma} is used. From our analysis also follows that so-called flattening potential can imitate the effects of intermediate decay channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Searches for signals from microscopic black holes in processes of proton collisions at <##> } s $ /sqrt s $ √s </##> = 7 TeV in the CMS experiment at the LHC

If the fundamental scale of multidimensional gravity is about one or several TeV units, microscopic black holes or objects referred to as string balls may be produced at the LHC. The most recent results obtained by the CMS Collaboration at the LHC from searches for such signals at the c.m. protoninteraction energy of 7 TeV and for an integrated luminosity of 4.7 fb{sup −1}. Lower limits on the masses of objects of strongly acting gravity were set in the parameter region accessible to tests at the present time. Prospects for further research in this field are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microscopic interpretation of the results of new measurements for the {sup 3}He(α, γ){sup 7}Be reaction

A microscopic approach based on the algebraic version of the resonating group method was implemented by applying it to the radiative capture reaction {sup 3}He(α, γ){sup 7}Be. The astrophysical S-factor of the reaction and the branching ratio between the capture to the ground and the first excited states of the {sup 7}Be nucleus were calculated. A comparison of the theoretical results with the most recent experimental data was performed, and good agreement with these data was found. Advantages of the theoretical approach realized are indicated, and possible ways to refine upon it are outlined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗