Analysis of structure and deformation behavior of AISI 316L tensile specimens from the second operational target module at the Spallation Neutron Source

In an earlier publication, tensile testing was performed on specimens removed from the first two operational targets of the Spallation Neutron Source (SNS). There were several anomalous features in the results. First, some specimens had very large elongations (up to 57%) while others had significantly smaller values. Second, there was a larger than the usual amount of data scatter in the elongation results. Third, the stress-strain diagrams of nominally similar specimens spanned a wide range of behavior ranging from expected irradiation-induced hardening to varying levels of force drop after yield point and indirect signs of "traveling deformation wave" behavior associated with strain-induced martensite formation. To investigate the cause(s) of such variable tensile behavior, several specimens from Target 2, spanning the range of observed tensile behavior, were chosen for detailed microstructural examination using electron backscattering analysis (EBSD). It was also shown that the steel employed in the construction of the target contained an unexpected bimodal grain size distribution, containing very large out-of-specification grains surrounded by necklaces of grains of within-specification sizes. The large grains were frequently comparable to the width of the gauge section of the tensile specimen. Moreover, the propensity to form martensite during deformation was shown to be accelerated by radiation but also to be very sensitive to the relative orientation of the grains with respect to the tensile axis. Specimens having large grains in the gauge that were most favorably oriented for production of martensite strongly exhibited the traveling deformation wave phenomenon, while those specimens with less favorably oriented grains had lesser or no degree of the wave effect, thereby accounting for the larger than expected data scatter.

316L↗

Cu/Al Through Au Diffusion Characterized by KPFM

The nanometer scale characterization technique of Frequency Modulated Kelvin Probe Force Microscopy (FM-KPFM) will be used to assess a diffusion study on thin metal films that undergo accelerated aging. The KPFM technique provides a relatively easy, non-destructive methodology that does not require high-vacuum facilities to obtain nanometer-scale spatial resolution of surface chemistry changes. The KPFM technique will be exercised in an effort to explore its capacity to map surface potential contrast caused by diffusion in a manner that allows for a qualitative assessment of diffusion of Cu or Al through Au. Supporting data will be obtained from traditional techniques: AES, XPS and UPS. An aging study was conducted on thin metal test specimens comprised of 500nm Cu or Al then 500nm Au on Si. The accelerated aging process was performed under inert conditions at aging temperatures of 100°C for Cu/Au film stack and 175°C for Al/Au film stack at aging times of 8 hours, 24 hours, 96 hours (4 days), and 216 hours (9 days).A calibration method was developed using Au, Al and Cu standards to establish precision and repeatability of the KPFM technique. The average Contact Potential Difference (CPD)s and standard deviations for each metal were found and summarized. Averages from surface roughness of the AFM topography images and roughness analysis of KPFM potential images which yield an average CPD of each area of unaged vs aged coupon surfaces were compared and show trends that indicate surface chemistry.

36 MATERIALS SCIENCE↗

CYRANO3 the EDF fuel code performance: Global overview and recent developments on MOX fuel

CYRANO3 is the thermal mechanical industrial code developed and used by EDF to simulate the nuclear fuel rod performance in pile, and during the disposal storage period as well. This code has already been used successfully for the last ten years by the EDF engineering teams in justifying the overall reloading options covering various fuels: UO{sub 2}, UO{sub 2} + gadolinium, MOX, UO{sub 2} plus additives, and various cladding as well proposed by the nuclear fuel suppliers. Its particularity is related to a construction around a standard one-dimensional thermal and mechanical finite elements kernel with an appropriate architecture to plug in any new functionalities or models. Since the beginning it is developed as a module able integrating within a core calculation chain. Other constrain is to always guaranty a running time consistent with the calculation of a core within a reasonable time. The objective is to provide the EDF designers with a convivial and qualified code, with robust algorithms and able to quickly evolve with computer performances. Algorithms are able to account for adiabatic transients and are robust enough to avoid any undesirable overflows. The permanent challenge is indeed to provide with the more descriptive simulations not degrading to much the running time. Developments are obviously performed within the strict Quality Insurance rules. The code is then associated to a large documentation base, including model specification, realization, validation and test procedures. Maintenance is managed through a system of anomaly and improvement forms. Computers are still evolving quickly. Therefore, after an architecture adaptation, the CYRANO3 code is now integrated in the PLEIADES platform as a PWR industrial application. The platform is an exchange space allowing sharing functionalities, models and properties. In this paper, we will give a global overview of the capabilities of CYRANO3 code to simulate the thermomechanical behavior of fuel rods, and we will focus on recent developments realized on MOX fuel. In CYRANO3 code, heterogeneous models (neutronic model, micromechanical behavior law and fission gas model) are developed for MOX fuels and integrated in order to account for differential evolutions between phases under irradiation. The methodology and these models are presented in this paper. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Decoupling size and surface effects of intermetallic CuPd nanocrystals for electrocatalytic nitrate reduction to ammonia

Nitrate pollution poses a major environmental challenge, but its electrochemical conversion to ammonia offers a sustainable waste-to-value solution. Here, in this study, we synthesized monodisperse, size-tunable B2-phase CuPd intermetallic nanocrystals (6–46 nm) and studied their performance in the electrochemical nitrate reduction reaction (eNO 3 RR). By using bromide ions to modulate Pd reduction and applying mild annealing, we achieved phase-pure B2 structures across all sizes. Catalytic testing revealed a volcano-like trend in ammonia yield, peaking at 33 nm nanocubes with a rate of 6.97 mol h −1 g −1 at −0.6 V vs. reversible hydrogen electrode (RHE). This optimum reflects a balance between the increased surface area of smaller particles and the enhanced exposure of active (100) facets in larger ones. Theoretical calculations indicated that the B2-CuPd (100) facet is favorable for nitrate adsorption, thereby supporting the high activity of nanocubes. Our results highlight the critical role of tuning both nanoparticle size and surface structure to maximize eNO 3 RR efficiency.

36 MATERIALS SCIENCE↗

Crystalline Si Surface Passivation with Nafion for Bulk Defects Detection with Electron Paramagnetic Resonance

Here, in monocrystalline Si (c-Si) solar cells, identification and mitigation of bulk defects are crucial to achieving a high photoconversion efficiency. To spectroscopically detect defects in the c-Si bulk, it is desirable to passivate the surface defects. Passivation of the c-Si surface with dielectrics such as Al 2 O 3 and SiNx requires deposition at elevated temperatures, which can influence defects in the bulk. Herein, we report on the passivation of different Czochralski (Cz) Si wafer surfaces by an organic copolymer, Nafion. We test the efficacy of the surface passivation at temperatures ranging from 6 to 473 K to detect bulk defects using electron paramagnetic resonance (EPR) spectroscopy. By comparing with state-of-the-art passivation layers, including Al 2 O 3 and liquid HF/HCl, we found that at room temperature, Nafion can provide comparable passivation of n-type Cz Si with an implied open-circuit voltage (iV oc ) of 713 mV and a recombination current prefactor J o of 5 fA/cm 2 . For p-type Cz Si, we obtained an iV oc of 682 mV with a J o of 22.4 fA/cm 2 . Scanning electron microscopy and photoluminescence reveal that Nafion can also be used to passivate the surface of c-Si solar cell fragments scribed from a solar cell module by using a laser. Consistent with previous studies, analysis of the EPR spectroscopy data confirms that the H-terminated surface is necessary, and fixed negative charge in Nafion is responsible for the field-effect passivation. While the surface passivation quality was maintained for almost 24 h, which is sufficient for spectroscopic measurements, the passivation degraded over longer durations, which can be attributed to surface SiO x growth. These results show that Nafion is a promising room-temperature surface passivation technique to study bulk defects in c-Si.

14 SOLAR ENERGY↗

Reducing Radiation Damage in Soft Matter with Femtosecond-Timed Single-Electron Packets

In spite of the development of a myriad of mitigation methods, radiation damage continues to be a major limiting factor in transmission electron microscopy. Intriguing results have been reported using pulsed-laser driven and chopped electron beams for modulated dose delivery, but the underlying relationships and effects remain unclear. Indeed, delivering precisely timed single-electron packets to the specimen has yet to be systematically explored, and no direct comparisons to conventional methods within a common parameter space have been made. Here, using a model linear saturated hydrocarbon (n-hexatriacontane, C 36 H 74 ), we show that precisely timed delivery of each electron to the specimen, with a well-defined and uniform time between arrival, leads to a repeatable reduction in damage compared to conventional ultralow-dose methods for the same dose rate and the same accumulated dose. Using a femtosecond pulsed laser to confine the probability of electron emission to a 300 fs temporal window, we find damage to be sensitively dependent on the time between electron arrival (controlled with the laser repetition rate) and on the number of electrons per packet (controlled with the laser-pulse energy). Relative arrival times of 5, 20, and 100 μs were tested for electron packets comprised of, on average, 1, 5, and 20 electrons. In general, damage increased with decreasing time between electrons and, more substantially, with increasing electron number. Further, we find that improvements relative to conventional methods vanish once a threshold number of electrons per packet is reached. The results indicate that precise electron-by-electron dose delivery leads to a repeatable reduction in irreversible structural damage, and the systematic studies indicate this arises from control of the time between sequential electrons arriving within the same damage radius, all else being equal.

36 MATERIALS SCIENCE↗

Cooperative Atomically Dispersed Fe–N 4 and Sn–N x Moieties for Durable and More Active Oxygen Electroreduction in Fuel Cells

One grand challenge for deploying porous carbons with embedded metal–nitrogen–carbon (M–N–C) moieties as platinum group metal (PGM)-free electrocatalysts in proton-exchange membrane fuel cells is their fast degradation and inferior activity. Here, we report the modulation of the local environment at Fe–N 4 sites via the application of atomic Sn–N x sites for simultaneously improved durability and activity. We discovered that Sn–N x sites not only promote the formation of the more stable D2 FeN 4 C 10 sites but also invoke a unique D3 SnN x –Fe II N 4 site that is characterized by having atomically dispersed bridged Sn–N x and Fe–N 4 . This new D3 site exhibits significantly improved stability against demetalation and several times higher turnover frequency for the oxygen reduction reaction (ORR) due to the shift of the reaction pathway from a single-site associative mechanism to a dual-site dissociative mechanism with the adjacent Sn site facilitating a lower overpotential cleavage of the O–O bond. This mechanism bypasses the formation of the otherwise inevitable intermediate that is responsible for demetalation, where two hydroxyl intermediates bind to one Fe site. Lastly, a mesoporous Fe/Sn-PNC catalyst exhibits a positively shifted ORR half-wave potential and more than 50% lower peroxide formation. This, in combination with the stable D3 site and enriched D2 Fe sites, significantly enhanced the catalyst’s durability as demonstrated in membrane electrode assemblies using complementary accelerated durability testing protocols.

36 MATERIALS SCIENCE↗

Consensus Guidelines for Delineation of Clinical Target Volume for Intensity-Modulated Pelvic Radiotherapy for the Definitive Treatment of Cervix Cancer

Purpose: Accurate target definition is vitally important for definitive treatment of cervix cancer with intensity-modulated radiotherapy (IMRT), yet a definition of clinical target volume (CTV) remains variable within the literature. The aim of this study was to develop a consensus CTV definition in preparation for a Phase 2 clinical trial being planned by the Radiation Therapy Oncology Group. Methods and Materials: A guidelines consensus working group meeting was convened in June 2008 for the purposes of developing target definition guidelines for IMRT for the intact cervix. A draft document of recommendations for CTV definition was created and used to aid in contouring a clinical case. The clinical case was then analyzed for consistency and clarity of target delineation using an expectation maximization algorithm for simultaneous truth and performance level estimation (STAPLE), with kappa statistics as a measure of agreement between participants. Results: Nineteen experts in gynecological radiation oncology generated contours on axial magnetic resonance images of the pelvis. Substantial STAPLE agreement sensitivity and specificity values were seen for gross tumor volume (GTV) delineation (0.84 and 0.96, respectively) with a kappa statistic of 0.68 (p < 0.0001). Agreement for delineation of cervix, uterus, vagina, and parametria was moderate. Conclusions: This report provides guidelines for CTV definition in the definitive cervix cancer setting for the purposes of IMRT, building on previously published guidelines for IMRT in the postoperative setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CACTUS: CO 2 Aerogel Capture Towards Utilization and Sequestration

The CACTUS project aimed to develop a novel solid sorbent and sorption module prototype for direct air capture (DAC) of carbon dioxide, by a moisture-swing adsorption (MSA) mechanism. Because MSA uses changes in humidity, not temperature to switch the sorbent from capturing CO 2 to releasing concentrated CO 2 it is > 4X more energy-efficient than the thermal swing process. The goal was to develop a sorbent with a CO 2 capture capacity of 1 mmol CO 2 /g sorbent (or 0.75 mmol CO 2 /g structured sorbent), at a projected scaled cost of < $\$$15/kg sorbent and demonstration of a path to < $\$$100/ton CO 2 . At the end of the project, we achieved 0.8 mmol CO 2 /g sorbent powders, 0.37 mmol CO 2 /g structured sorbent (50% of target), at a projected cost of $\$$29/kg sorbent and an estimated cost of $\$$160/ton CO 2 . The key innovation was SRI’s patented polymer aerogel synthesis platform, which was adapted to produce a nanoporous aerogel with a high density of CO 2 -adsorbing quaternary ammonium groups. This research discovered a new ammonium polymer sorbent and identified a chemical path for its fabrication. The new process solved the monomer immiscibility challenge encountered with the initial method (ammonium is hydrophilic and the crosslinker is hydrophobic). The team fabricated structured sorbent sheets consisting of a non-woven porous substrate impregnated with ammonium polymer and demonstrated its operation in custom made breakthrough test setup MSA DAC built at SRI, and which operates similarly to the envisioned large-scale CO 2 capture plant, to provide data for techno-economic analysis (TEA). TEA sensitivity analysis indicated that ∼$\$$100/ton CO 2 can be achieved if the target capacity of 0.75 mmol CO 2 /g structured sorbent is met. Also identified routes to decrease sorbent manufacturing cost to ∼$\$$19/kg by reducing amounts and recycling the organic solvents. More work is needed on transitioning process manufacturing from powders (which showed a capacity of up to 0.8 mmol/g sorbent) to structured sheets which showed a capacity of 0.37 mmol CO 2 /g structured sorbent (or 0.44 mmol/g sorbent if one excludes the inert porous substrate). This is likely due to different micro/nano-structure of the sorbent and material processing constraints at the laboratory scale. Sorbent cycling studies (> 100 cycles) are needed to investigate its performance stability over time.

99 GENERAL AND MISCELLANEOUS↗

Sensitivity and uncertainty of the IFR-1 BISON benchmark

The fuel performance code BISON is being used to evaluate metallic fuel for a new fast-spectrum test reactor called the Versatile Test Reactor, which is being considered for adoption by the US Department of Energy. To quantify the accuracy of BISON predictions, researchers at Oak Ridge National Laboratory have been developing a series of benchmarks based on legacy metallic fuel experiments. As part of this effort, the sensitivity of BISON predictions to variations in model inputs and the uncertainties associated with BISON predictions must be established. This paper summarizes efforts to perform a comprehensive sensitivity analysis (SA) and uncertainty quantification (UQ) on a benchmark based on the IFR-1 experiment.For the SA, at least one input was chosen from every BISON model and physics module used in the benchmark. The inputs were varied individually in a series of BISON simulations. Here, the resulting variations in benchmark predictions were normalized to calculate sensitivities. These sensitivities were then used to inform input selections for the UQ.The UQ was performed using the Monte Carlo UQ method. A literature review was conducted to estimate uncertainty distributions for the selected inputs, and values were sampled randomly from each distribution in a series of BISON simulations. Variations in the benchmark predictions were used to estimate uncertainty distributions and confidence intervals. It was found that nearly 100% of the benchmark predictions matched the corresponding legacy values within the confidence intervals. However, this is at least partially because the confidence intervals associated with benchmark predictions were wide. The uncertainty contributions of assumptions in the benchmark, experimental uncertainties, and BISON models were quantified. Some analysis was performed to identify inputs that contributed to the uncertainties. Finally, recommendations are made for future benchmark and future BISON development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Phase II Trial of Arc-Based Hypofractionated Intensity-Modulated Radiotherapy in Localized Prostate Cancer

Purpose: To evaluate acute and late genitourinary (GU) and gastrointestinal (GI) toxicity and biochemical control of hypofractionated, image-guided (fiducial markers or ultrasound guidance), simplified intensity-modulated arc therapy for localized prostate cancer. Methods and Materials: This Phase II prospective clinical trial for T1a-2cNXM0 prostate cancer enrolled 66 patients who received 63.2 Gy in 20 fractions over 4 weeks. Fiducial markers were used for image guidance in 30 patients and daily ultrasound for the remainder. Toxicity was scored according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 3.0. Results: Median follow-up was 36 months. Acute Phase Grade 2 and 3 toxicity was 34% and 9% for GU vs. 25% and 10% for GI symptoms. One Grade 4 acute GI toxicity occurred in a patient with unrecognized Crohn's disease. Late Grade 2 and 3 toxicity for GU was 14% and 5%, and GI toxicity was 25% and 3%. One late GI Grade 4 toxicity was observed in a patient with significant comorbidities (anticoagulation, vascular disease). Acute GI toxicity {>=}Grade 2 was shown to be a predictor for late toxicity Grade {>=}2 (p < 0.001). The biochemical disease-free survival at 3 years was 95%. Conclusions: Hypofractionated simplified intensity-modulated arc therapy radiotherapy given as 63.2 Gy in 20 fractions demonstrated promising biochemical control rates; however, higher rates of acute Grade 3 GU and GI toxicity and higher late Grade 2 GU and GI toxicity were noted. Ongoing randomized controlled trials should ultimately clarify issues regarding patient selection and the true rate of severe toxicity that can be directly attributed to hypofractionated radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensitivity and Uncertainty of the IFR-1 BISON Benchmark

The fuel performance code BISON is being used to evaluate metallic fuel for a new fast-spectrum test reactor called the Versatile Test Reactor, which is being considered by the US Department of Energy. To quantify the accuracy of BISON predictions, researchers at Oak Ridge National Laboratory have been developing a series of benchmarks based on legacy metallic fuel experiments. As part of this effort, the sensitivity of BISON predictions to variations in model inputs and the uncertainties associated with BISON predictions must be established. This report summarizes efforts to perform a comprehensive sensitivity analysis (SA) and uncertainty quantification (UQ) on a benchmark based on the IFR-1 experiment. For the SA, at least one input was chosen from every BISON model and physics module used in the benchmark. The inputs were varied individually in a series of BISON simulations. The resulting variations in benchmark predictions were normalized to calculate sensitivities. The strongest sensitivities were identified and used to inform input selections for the UQ. The UQ was performed using the Monte Carlo UQ method. A literature review was conducted to estimate uncertainty distributions for the selected inputs, and values were sampled randomly from each distribution in a series of BISON simulations. Variations in the benchmark predictions were used to estimate uncertainty distributions and confidence intervals. It was found that nearly 100% of benchmark predictions matched the corresponding legacy values within the confidence intervals. However, this is at least partially because of the wide confidence intervals associated with the benchmark predictions. The uncertainty contributions of assumptions in the benchmark, experimental uncertainties, and BISON models were quantified. Some analysis was performed to identify inputs that contributed to the uncertainties. Finally, recommendations are made for future benchmark development and future BISON development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Moderation Module for High-Temperature Micro-Reactor Applications

Development and deployment of micro-reactors that provide competitive efficiency, prevailing compactness, and inherent safety is an immediate focus of the U.S. nuclear industry. For thermal neutron micro-reactors operating at elevated temperature for optimized efficiency, such as micro molten-salt reactors (MSRs), heat-pipe reactors, and very-high temperature reactors (VHTRs), high-performance moderator based on metal hydride can enhance the neutron economy and therefore achieve reduced weight and enhanced portability. As unclad metal hydride inevitably decomposes at elevated temperature, an enclosure is required for hydride moderator to deliver desired performance at elevated temperatures. Conventional moderator enclosure solutions based on high-temperature alloys introduce extraneous neutron penalty into the micro-reactor, affecting the neutronic benefits provided by the hydride moderator. Additionally, the compatibility between the high-temperature alloy enclosure and the micro-reactor matrix is also a potential issue. In this report, we disclose an Advanced Moderator Module (AMM) concept enabled by an innovative enclosure solution combining the advantages of refractory metals, ceramic matrix composites (CMCs), and advanced coating technology to serve as hydrogen permeation barrier up to very-high temperatures. A schematic description of the AMM structure is illustrated in Figure A1. The AMM contains a moderating material core made of metal hydride with high thermal stability, such as YH 2-x . The hydride core is enclosed by an H 2 barrier layer coated on a ductile refractory metal liner to minimize hydrogen loss during high-temperature operation. A ceramic matrix composite (CMC) cladding is adopted to provide further structural strength, especially during power transients. Between the CMC cladding and metal liner, an extra diffusion barrier coating is inserted to suppress the chemical interaction at elevated temperatures. Hence, based on a series of innovative material solutions, the AMM is capable of containing the metal hydride core at elevated temperature (>900oC) inside coated and lined CMC envelop with negligible hydrogen loss throughout the microreactor lifetime. The benefit of the AMM technology was assessed based on a comprehensive multi-stage reactor-physics analysis. Advanced moderation based on hydride metals (such as YH2-x) enables reaching optimum moderation with higher fuel content than traditional VHTR technology, which is required to design compact micro-reactor cores targeting long-life operation. The AMM enclosure technology provides lower thermal neutron absorption rates than traditional solutions (based on stainless steel or Mo-based alloy such as TZM), which reduces the fissile enrichment requirements by 6-8% on a TRISO-fueled design based on the EMPIRE core. Finally, combining the hydride moderator with neutron transparent enclosure solutions provides significant potential to boost neutronics performance of micro-reactors in terms of increased core lifetime or reduced size and weight by 30-50% on a micro-reactor based on the Holos Quad technology. The progress and plans for on-going development and demonstration efforts are also discussed in this report. The current demonstration of AMM is focused on the hydrogen diffusion barrier demonstration under thermal cycling, while radiation tolerance demonstration is planned. The next step of the demonstration plan will be the assembly of miniature AMM for high-temperature testing, which can be used as a prototype for future pilot scale demonstration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Crowder College MARET Center (Final Scientific Technical Report)

Following decades of success in solar energy projects, the Missouri Legislature designated Crowder College in 1992 as the State's renewable energy education center. The resulting Missouri Alternative and Renewable Energy Technology (MARET) Center is recognized internationally for its contributions to the energy field. The mission of the MARET Center is to expand renewable energy throughout the region with education, applied research, and economic development. Educational programs include certification and transfer degrees encompassing green construction, solar thermal energy, solar electricity, and wind. The MARET Center also assists in new product development and other business support services in renewable energy. The Missouri Alternative and Renewable Energy Technology (MARET) Center at Crowder College hopes to eventually develop a 27,500 ft 2 facility as a living laboratory to support solar and other renewable and sustainable energy development through professional degrees, new product development and commercialization, renewable energy business incubation, and consumer education. The primary objective of the current project was to complete Stage One of this building, with solar, wind, and geothermal technologies installed to power its 9,216 ft 2 office, classroom, and research spaces. This MARET Center includes a modular roof structure that permits both solar module mounting and daylighting, PV/thermal hybrid modules pioneered in Crowder Solar Decathlon homes, modular electrical management subsystems; and modular delivery systems for heating and cooling the structure. The MARET Facility will operate as a Net Positive energy building, consistently producing surplus energy for distributed generation on the utility grid. The modular design of the energy systems within the building is to serve as a scalable and repeatable model for a wide variety of building applications and climate zones. As a living laboratory of renewable energy, exploring and validating new applications of solar and other renewable technologies, the MARET Facility will house a wide variety of programs which will advance implementation of renewable energy throughout the region. These program goals include; Curriculum in renewable energy for pre-engineering transfer programs; Certification and degree programs for technical degrees for Energy Efficiency, Wind, Photovoltaic and Solar Thermal professionals; Short courses and workshops for building management and design professionals; Public education and demonstration projects in renewable energy through conferences and K-12 educational outreach; Technical degree offering in building construction incorporating “best practices” for energy efficiency and renewables; and Business incubators for new renewable energy businesses and new product development. The new MARET facility will support the mission of the US Department of Energy (DOE) Solar Program, “to improve America’s security, environmental quality, and economic prosperity through public-private partnerships that bring reliable and affordable solar energy technologies to the marketplace,” through a variety of educational and business assistance programs. Further, technical innovations planned for the MARET facility and its applied research activities will advance the Solar Program strategic goals to “reduce the cost of solar energy to the point it becomes competitive in relevant energy markets (e.g., buildings, power plants) and for solar technology to enable a sustainable solar industry.” Overarching Goals relative to program needs, future expansion, flexibility, quality of materials, and construction and operational costs:; Experimental: The structure and systems of the building operate as an educational resource. The systems are meant to be a source for data collection and study for building users and instructors; Educational: Part of the evolution of this building and its ongoing goals is to use the building as an educational tool, one where new ideas developed in the world and especially at Crowder can be tested further as part of MARET's curriculum; LEED Platinum: achieve highest level of LEED certification; Net Zero: The building will utilize existing wind and alternate energy sources on campus and add solar PVT panels and achieve as close as possible to a net zero energy usage; and Phase II: The phase II portion of this project will expand the Internet student area, additional classrooms, and labs, as well as an auditorium and exhibit area.

14 SOLAR ENERGY↗

Development of Surface Sampling Techniques for the Canister Deposition Field Demonstration (FY22 Update)

This report describes the proposed surface sampling techniques and plan for the multi-year Canister Deposition Field Demonstration (CDFD). The CDFD is primarily a dust deposition test that will use three commercial 32PTH2 NUHOMS welded stainless steel storage canisters in Advanced Horizontal Storage Modules, with planned exposure testing for up to 10 years at an operating ISFSI site. One canister will be left at ambient condition, unheated; the other two will have heaters to achieve canister surface temperatures that match, to the degree possible, spent nuclear fuel (SNF) loaded canisters with heat loads of 10 kW and 40 kW. Surface sampling campaigns for dust analysis will take place on a yearly or bi-yearly basis. The goal of the planned dust sampling and analysis is to determine important environmental parameters that impact the potential occurrence of stress corrosion cracking on SNF dry storage canisters. Specifically, measured dust deposition rates and deposited particle sizes will improve parameterization of dust deposition models employed to predict the potential occurrence and timing of stress corrosion cracks on the stainless steel SNF canisters. The size, morphology, and composition of the deposited dust and salt particles will be quantified, as well as the soluble salt load per unit area and the rate of deposition, as a function of canister surface temperature, location, time, and orientation. Previously, a preliminary sampling plan was developed, identifying possible sampling locations on the canister surfaces and sampling intervals; possible sampling methods were also described. Further development of the sampling plan has commenced through three different tasks. First, canister surface roughness, a potentially important parameter for air flow and dust deposition, was characterized at several locations on one of the test canisters. Second, corrosion testing to evaluate the potential lifetime and aging of thermocouple wires, spot welds, and attachments was initiated. Third, hand sampling protocols were developed, and initial testing was carried out. The results of those efforts are presented in this report. The information obtained from the CDFD will be critical for ongoing efforts to develop a detailed understanding of the potential for stress corrosion cracking of SNF dry storage canisters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methodology for accident analyses of fusion breeder blankets

'Fusion for Energy' (F4E) develops designs and implements the European Test Blanket Systems (TBS) in ITER - Helium-Cooled Lithium-Lead (HCLL) and Helium-Cooled Pebble-Bed (HCPB). Safety demonstration is an essential element for the integration of TBS in ITER and accident analyses are one of its critical segments. A systematic approach to the accident analyses had been acquired under the F4E contract on TBS safety analyses. F4E technical requirements and AMEC and INL efforts resulted in the development of a comprehensive methodology for fusion breeding blanket accident analyses. It addresses the specificity of the breeding blankets design, materials and phenomena and at the same time is consistent with the one already applied to ITER accident analyses. Methodology consists of several phases. At first the reference scenarios are selected on the base of FMEA studies. In the second place elaboration of the accident analyses specifications we use phenomena identification and ranking tables to identify the requirements to be met by the code(s) and TBS models. Thus the limitations of the codes are identified and possible solutions to be built into the models are proposed. These include among others the loose coupling of different codes or code versions in order to simulate multi-fluid flows and phenomena. The code selection and issue of the accident analyses specifications conclude this second step. Furthermore the breeding blanket and ancillary systems models are built on. In this work challenges met and solutions used in the development of both MELCOR and RELAP5 codes models of HCLL and HCPB TBSs will be shared. To continue the developed models are qualified by comparison with finite elements analyses, by code to code comparison and sensitivity studies. Finally, the qualified models are used for the execution of the accident analyses of specific scenario. When possible the methodology phases will be illustrated in the paper by limited number of tables and figures. Description of each phase and its results in detail as well the methodology applications to EU HCLL and HCPB TBSs will be published in separate papers. The developed methodology is applicable to accident analyses of other TBSs to be tested in ITER and as well to DEMO breeding blankets.

Fusion Safety↗

Tissue factor contributes to neutrophil CD11b expression in alpha-naphthylisothiocyanate-treated mice

Cholestatic liver injury induced by alpha-naphthylisothiocyanate (ANIT) is provoked by injury to intrahepatic bile ducts and the progression of hepatic necrosis requires the procoagulant protein tissue factor (TF) and extrahepatic cells including neutrophils. Recent studies have shown that myeloid cell TF contributes to neutrophil activation. We tested the hypothesis that myeloid cell TF contributes to neutrophil activation in ANIT-treated mice. TF activity in liver homogenates increased significantly in TF{sup flox/flox} mice treated with ANIT, but not in TF{sup flox/flox}/LysMCre mice (TF{sup {Delta}Myeloid} mice), which have reduced TF expression in monocytes/macrophages and neutrophils. Myeloid cell-specific TF deficiency did not alter expression of the chemokines KC or MIP-2 but reduced hepatic neutrophil accumulation in ANIT-treated mice at 48 h as indicated by tissue myeloperoxidase (MPO) activity. Myeloid cell TF deficiency significantly reduced CD11b expression by blood neutrophils in ANIT-treated mice, and this was associated with reduced plasma MPO protein levels, an index of neutrophil degranulation. However, myeloid cell-specific TF deficiency had no effect on ANIT-induced coagulation cascade activation. The increase in serum ALT and ALP activities in ANIT-treated mice was reduced by myeloid cell TF deficiency (p < 0.05), but the myeloid cell TF deficiency did not reduce hepatic necrosis at 48 h, as determined by histopathology and morphometry. The results suggest that myeloid cell TF contributes to neutrophil CD11b expression during cholestasis by a coagulation-independent pathway. However, the resultant reduction in neutrophil accumulation/activation is insufficient to substantially reduce ANIT hepatotoxicity, suggesting that myeloid cell TF is only one of many factors modulating hepatic necrosis during cholestasis. - Research Highlights: > Myeloid cell tissue factor contributes to liver procoagulant activity during acute cholestasis. > ANIT-induced coagulation cascade activation is independent of myeloid cell tissue factor. > Myeloid cell tissue factor contributes to neutrophil CD11b priming during cholestasis.

60 APPLIED LIFE SCIENCES↗

Daily Image Guidance With Cone-Beam Computed Tomography for Head-and-Neck Cancer Intensity-Modulated Radiotherapy: A Prospective Study

Purpose: To report on a prospective clinical trial of the use of daily kilovoltage cone-beam computed tomography (CBCT) to evaluate the interfraction and residual error motion of patients undergoing intensity-modulated radiotherapy for head-and-neck cancer. Methods and Materials: Patients were treated with intensity-modulated radiotherapy with an Elekta linear accelerator using a mounted CBCT scanner. CBCT was performed before every treatment, and translational (but not rotational) corrections were performed. At least once per week, a CBCT scan was obtained after intensity-modulated radiotherapy. Variations were measured in the medial-lateral, superoinferior, and anteroposterior dimensions, as well as in the rotation around these axes. Results: A total of 28 consecutive patients (1,013 CBCT scans) were studied. The average interfraction shift was 1.4 +- 1.4, 1.7 +- 1.9, and 1.8 +- 2.1 mm in the medial-lateral, superoinferior, and anteroposterior dimensions, respectively. The corresponding average residual error shifts were 0.7 +- 0.8, 0.9 +- 0.9, and 0.9 +- 0.9 mm. These data indicate that in the absence of daily CBCT image-guided radiotherapy, a clinical target volume to planning target volume margin of 3.9, 4.1, and 4.9 mm is needed in the medial-lateral, superoinferior, and anteroposterior dimensions, respectively. With daily CBCT, corresponding margins of 1.6, 2.5, and 1.9 mm should be acceptable. Subgroup analyses showed that larynx cancers and/or intratreatment weight loss indicate a need for slightly larger clinical target volume to planning target volume margins. Conclusion: The results of our study have shown that image-guided radiotherapy using CBCT for head-and-neck cancer is effective. These data suggest it allows a reduction in the clinical target volume to planning target volume margins by about 50%, which could facilitate future studies of dose escalation and/or improved toxicity reduction. Caution is particularly warranted for cases in which the targets are mobile (e.g., the tongue).

62 RADIOLOGY AND NUCLEAR MEDICINE↗