Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

A Simplified Building Modeling Approach for Identifying Whole Building Retrofits

Building Energy Modeling (BEM) is an effective strategy for optimizing new and retrofit building design, evaluating its energy savings potential and rating its energy performance. However, because of the complexity and expense of modeling, only a small percentage of buildings are simulated. Over 80% of buildings are <25,000 ft2, and the cost associated with BEM can be a big deterrent for reaching this subsector, which usually ends up complying with energy codes and qualifying for incentives using prescriptive measures or generalized design guides. Similarly, efficiency considerations for small building retrofits are often identified through deemed measures or Technical Reference Manuals, which though a scalable and convenient approach, can limit innovation in design and optimization of measures. Simplification of the modeling process, where appropriate, can lead to increased energy savings and more informed decision making. This paper will discuss the development of a ruleset for a simplified approach based on the Performance Rating Method (PRM) contained in ASHRAE Standard 90.1. The approach aims to simplify and lower the cost of the energy modeling process in a controlled and documented manner. An anticipated outcome is an increased use of BEM and its effectiveness in the design, retrofit and operation of commercial buildings. In addition, simplification of the modeling process will result in fewer errors from misinterpretations of both program requirements and program intent in simulation software. The paper will discuss the need and advantages of a simplified modeling approach for whole building retrofits and the technical process for achieving the same.

Goel, Supriya↗

Reactivity Coefficient Measurements to Aid in Reducing Compensating Errors in Plutonium Nuclear Data

Compensating errors between several nuclear data observables in a nuclear data library can adversely impact application simulations. The primary goal of the EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) is to reduce compensating errors between fast (0.1–5 MeV) 239Pu nuclear data for prompt fission neutron spectra (PFNS), average prompt fission neutron multiplicities, and neutron induced fission, capture, elastic, and inelastic cross sections. This work will focus on the design and execution of void reactivity coefficient measurements in the EUCLID experiment, performed on the Planet vertical lift critical assembly machine at the National Criticality Experiments Research Center (NCERC). Two different base configurations were designed and measured, one with high neutron leakage, and one with low neutron leakage. Both were primarily made up of plutonium metal (Zero Power Physics Reactor plates) without interstitial moderators and reflected by half-inch aluminum. Design optimization showed that void reactivity coefficient measurements in three locations per configuration was most impactful to reduce nuclear data uncertainties due to the varying impacts from elastic and inelastic scattering, as well as fission and capture. The locations for measurements were chosen based on preliminary studies which balanced measurement uncertainty and measurement practicality. The measurements were also selected to have sensitivities maximally complementary to previous arrangements. Comparisons across nuclear data libraries highlight the potential impact.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Off-Angle Iris Correction Methods

In many real world iris recognition systems obtaining consistent frontal images is problematic do to inexperienced or uncooperative users, untrained operators, or distracting environments. As a result many collected images are unusable by modern iris matchers. In this chapter we present four methods for correcting off-angle iris images to appear frontal which makes them compatible with existing iris matchers. The methods include an affine correction, a retraced model of the human eye, measured displacements, and a genetic algorithm optimized correction. The affine correction represents a simple way to create an iris image that appears frontal but it does not account for refractive distortions of the cornea. The other method account for refraction. The retraced model simulates the optical properties of the cornea. The other two methods are data driven. The first uses optical flow to measure the displacements of the iris texture when compared to frontal images of the same subject. The second uses a genetic algorithm to learn a mapping that optimizes the Hamming Distance scores between off-angle and frontal images. In this paper we hypothesize that the biological model presented in our earlier work does not adequately account for all variations in eye anatomy and therefore the two data-driven approaches should yield better performance. Results are presented using the commercial VeriEye matcher that show that the genetic algorithm method clearly improves over prior work and makes iris recognition possible up to 50 degrees off-angle.

iris recognition↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements: Preprint

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multisource modeling of flattening filter free (FFF) beam and the optimization of model parameters

Purpose: With the introduction of flattening filter free (FFF) linear accelerators to radiation oncology, new analytical source models for a FFF beam applicable to current treatment planning systems is needed. In this work, a multisource model for the FFF beam and the optimization of involved model parameters were designed. Methods: The model is based on a previous three source model proposed by Yang et al. [''A three-source model for the calculation of head scatter factors,'' Med. Phys. 29, 2024-2033 (2002)]. An off axis ratio (OAR) of photon fluence was introduced to the primary source term to generate cone shaped profiles. The parameters of the source model were determined from measured head scatter factors using a line search optimization technique. The OAR of the photon fluence was determined from a measured dose profile of a 40x40 cm{sup 2} field size with the same optimization technique, but a new method to acquire gradient terms for OARs was developed to enhance the speed of the optimization process. The improved model was validated with measured dose profiles from 3x3 to 40x40 cm{sup 2} field sizes at 6 and 10 MV from a TrueBeam STx linear accelerator. Furthermore, planar dose distributions for clinically used radiation fields were also calculated and compared to measurements using a 2D array detector using the gamma index method. Results: All dose values for the calculated profiles agreed with the measured dose profiles within 0.5% at 6 and 10 MV beams, except for some low dose regions for larger field sizes. A slight overestimation was seen in the lower penumbra region near the field edge for the large field sizes by 1%-4%. The planar dose calculations showed comparable passing rates (>98%) when the criterion of the gamma index method was selected to be 3%/3 mm. Conclusions: The developed source model showed good agreements between measured and calculated dose distributions. The model is easily applicable to any other linear accelerator using FFF beams as the required data include only the measured PDD, dose profiles, and output factors for various field sizes, which are easily acquired during conventional beam commissioning process.

60 APPLIED LIFE SCIENCES↗

A remote sensing algorithm for vertically resolved cloud condensation nuclei number concentrations from airborne and spaceborne lidar observations

Cloud condensation nuclei (CCN) are mediators of aerosol–cloud interactions (ACIs), contributing to the largest uncertainties in the understandings of global climate change. We present a novel remote-sensing-based algorithm that quantifies the vertically resolved CCN number concentrations (N CCN ) using aerosol optical properties measured by a multiwavelength lidar. The algorithm considers five distinct aerosol subtypes with bimodal size distributions. The inversion used the lookup tables developed in this study, based on the observations from the Aerosol Robotic Network, to efficiently retrieve optimal particle size distributions from lidar measurements. The method derives dry aerosol optical properties by implementing hygroscopic enhancement factors in lidar measurements. The retrieved optically equivalent particle size distributions and aerosol-type-dependent particle composition are utilized to calculate critical diameters using κ-Köhler theory and N CCN at six supersaturations ranging from 0.07 % to 1.0 %. Sensitivity analyses indicate that uncertainties in extinction coefficients and relative humidity greatly influence the retrieval error in N CCN . The potential of this algorithm is further evaluated by retrieving N CCN using airborne lidar from the NASA ObseRvations of Aerosols above CLouds and their intEractionS (ORACLES) campaign and is validated against simultaneous measurements from the CCN counter. The independent validation with robust correlation demonstrates promising results. Furthermore, the N CCN has been retrieved for the first time using a proposed algorithm from spaceborne lidar – Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) – measurements. The application of this new capability demonstrates the potential for constructing a 3D CCN climatology at a global scale, which helps to better quantify ACI effects and thus reduce the uncertainty in aerosol climate forcing.

54 ENVIRONMENTAL SCIENCES↗

TH-C-BRD-07: Minimizing Dose Uncertainty for Spot Scanning Beam Proton Therapy of Moving Tumor with Optimization of Delivery Sequence

Purpose: Intensity modulated proton therapy (IMPT) has been shown to be able to reduce dose to normal tissue compared to intensity modulated photon radio-therapy (IMRT), and has been implemented for selected lung cancer patients. However, respiratory motion-induced dose uncertainty remain one of the major concerns for the radiotherapy of lung cancer, and the utility of IMPT for lung patients was limited because of the proton dose uncertainty induced by motion. Strategies such as repainting and tumor tracking have been proposed and studied but repainting could result in unacceptable long delivery time and tracking is not yet clinically available. We propose a novel delivery strategy for spot scanning proton beam therapy. Method: The effective number of delivery (END) for each spot position in a treatment plan was calculated based on the parameters of the delivery system, including time required for each spot, spot size and energy. The dose uncertainty was then calculated with an analytical formula. The spot delivery sequence was optimized to maximize END and minimize the dose uncertainty. 2D Measurements with a detector array on a 1D moving platform were performed to validate the calculated results. Results: 143 2D measurements on a moving platform were performed for different delivery sequences of a single layer uniform pattern. The measured dose uncertainty is a strong function of the delivery sequence, the worst delivery sequence results in dose error up to 70% while the optimized delivery sequence results in dose error of <5%. END vs. measured dose uncertainty follows the analytical formula. Conclusion: With optimized delivery sequence, it is feasible to minimize the dose uncertainty due to motion in spot scanning proton therapy.

60 APPLIED LIFE SCIENCES↗

A General Purpose Real-Time Optimization Strategy Applied to Minimizing Simultaneous Heating and Cooling in Buildings

Supervisory control strategies in heating, ventilating, and air-conditioning (HVAC) systems hold the potential for significant energy savings but they are difficult to set up and often depend on unreliable sensor measurements. In this paper, we propose a sensor-free approach to minimizing the energy penalties due to simultaneous heating and cooling in variable-air-volume (VAV) systems with reheat. A general-purpose real-time optimizer is described that is easy to set-up and integrate with existing control logic. A cost function is derived that quantifies the simultaneous heating and cooling penalty that does not require any sensor measurements. The optimizer then minimizes this cost function by automatically adjusting the supply temperature setpoint in the air-handling unit. The paper describes the approach and shows results from application from field trials on a 27-zone building.

Salsbury, Timothy↗

Respirable Release Fraction Measurement Chamber (RRFMC) - 18321

The Respirable Release Fraction Measurement Chamber (RRFMC) is designed to hoist a container to a predetermined height, drop it, and then utilize aerosol particle counters to measure the mass of powder that is released from failed containers. The RRFMC hoist mechanism is located inside an airtight (6.1 m high) steel enclosure that isolates the released test aerosol from the surrounding lab room environment. Accurate measurement of the released test powder is necessary for estimating the total released mass of material. Cerium oxide will be used as a surrogate for plutonium oxide. The range of the aerodynamic diameter of cerium oxide test powder was characterized both by cascade impaction and aerodynamic sizing. The scope of this paper includes the physical parameters required for accurately measuring the total mass of released powder, the fabrication of the tower, various strategies to optimize concentration sampling, and developing methods to accurately measure the respirable fraction, airborne release fraction, and the damage ratio. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chapter 16: Retrocommissioning Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

Retrocommissioning (RCx) is a systematic process for optimizing energy performance in existing buildings. It specifically focuses on improving the control of energy-using equipment (e.g., heating, ventilation, and air conditioning [HVAC] equipment and lighting) and typically does not involve equipment replacement. Field results have shown proper RCx can achieve energy savings ranging from 5 percent to 20 percent, with a typical payback of two years or less (Thorne 2003). The method presented in this protocol provides direction regarding: (1) how to account for each measure's specific characteristics and (2) how to choose the most appropriate savings verification approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studies of Front-End Electronics for High-Precision Timing Measurements with LGADs [Poster]

In Time-of-Arrival (ToA) measurements, simulations can be used to optimize precision detection and implementation methods of front-end electronics. The simulation tested in this project takes the response of a filter (in the s-domain) from a noisy input current signal from the detector, an LGAD (Low-Gain Avalanche Diode), and uses a threshold to determine the ToA value for the signal. Measuring the ToA values for a large sample of events and comparing them to a reference statistically produces the timing precision of the simulation. Here, the sub-algorithm to model LGAD events with piecewise linear (PWL) approximations (for more efficient Laplace transforms) was optimized. Using the Fourier Discrete Cosine Transform, 25 points could be selected to describe the primary behavior of the signal. Results showed that timing precision is on par with previous methods. We also found that the new algorithm is faster and equally consistent in producing accurate PWL approximations. Testi ng with larger samples is required to fully verify the new algorithm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam emittance measurements and simulations of injector line for radio frequency quadrupole

A 400 keV deuteron (D{sup +}) radio frequency quadrupole (RFQ) accelerator has been designed, built, and commissioned at the Bhabha Atomic Research Centre, India. A beam line has been developed for injecting deuterons into the 400 keV RFQ. This comprises of a RF plasma ion source and a low energy beam transport (LEBT) system, consisting of two solenoid magnets and two steerer magnets. The ion source is characterized in terms of transverse beam emittance. A slit-wire scanner based emittance measurement setup has been developed for the transverse emittance measurements of H{sup +} and D{sup +} beams. The measured emittance values are found to be well within the acceptance value for the RFQ. These measured emittance parameters are used to optimize the solenoid fields in LEBT to match the beam from the ion source to RFQ. TRACEWIN simulation code is used for the beam transport simulations. The simulations show 99% transmission of D{sup +} beam through the RFQ, while 95% transmission has been measured experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics of superconducting qubit relaxation times

Superconducting qubits are a leading candidate for quantum computing but display temporal fluctuations in their energy relaxation times T 1 . This introduces instabilities in multi-qubit device performance. Furthermore, autocorrelation in these time fluctuations introduces challenges for obtaining representative measures of T 1 for process optimization and device screening. These T 1 fluctuations are often attributed to time varying coupling of the qubit to defects, putative two level systems (TLSs). In this work, we develop a technique to probe the spectral and temporal dynamics of T 1 in single junction transmons by repeated T 1 measurements in the frequency vicinity of the bare qubit transition, via the AC-Stark effect. Across 10 qubits, we observe strong correlations between the mean T 1 averaged over approximately nine months and a snapshot of an equally weighted T 1 average over the Stark shifted frequency range. These observations are suggestive of an ergodic-like spectral diffusion of TLSs dominating T 1 , and offer a promising path to more rapid T 1 characterization for device screening and process optimization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dissolution of Plutonium Metal in 8-10 M Nitric Acid

The H-Canyon facility will be used to dissolve Pu metal for subsequent purification and conversion to plutonium dioxide (PuO 2 ) using Phase II of HB-Line. To support the new mission, the development of a Pu metal dissolution flowsheet which utilizes concentrated (8-10 M) nitric acid (HNO 3 ) solutions containing potassium fluoride (KF) is required. Dissolution of Pu metal in concentrated HNO 3 is desired to eliminate the need to adjust the solution acidity prior to purification by anion exchange. The preferred flowsheet would use 8-10 M HNO 3 , 0.015-0.07 M KF, and 0.5-1.0 g/L Gd to dissolve the Pu up to 6.75 g/L. An alternate flowsheet would use 8-10 M HNO 3 , 0.1-0.2 M KF, and 1-2 g/L B to dissolve the Pu. The targeted average Pu metal dissolution rate is 20 mg/min-cm 2 , which is sufficient to dissolve a 'standard' 2250-g Pu metal button in 24 h. Plutonium metal dissolution rate measurements showed that if Gd is used as the nuclear poison, the optimum dissolution conditions occur in 10 M HNO 3 , 0.04-0.05 M KF, and 0.5-1.0 g/L Gd at 112 to 116°C (boiling). These conditions will result in an estimated Pu metal dissolution rate of ~11-15 mg/min-cm 2 and will result in dissolution times of 36-48 h for standard buttons. The recommended minimum and maximum KF concentrations are 0.03 M and 0.07 M, respectively. The maximum KF concentration is dictated by a potential room-temperature Pu-Gd-F precipitation issue at low Pu concentrations. The purpose of the experimental work described in this report was two-fold. Initially a series of screening experiments was performed to measure the dissolution rate of Pu metal as functions of the HNO 3 , KF, and Gd or B concentrations. The objective of the screening tests was to propose optimized conditions for subsequent flowsheet demonstration tests. Based on the rate measurements, this study found that optimal dissolution conditions in solutions containing 0.5-1.0 g/L Gd occurred in 8-10 M HNO 3 with 0.04-0.05 M KF at 112 to 116°C (boiling). The testing also showed that solutions containing 8-10 M HNO 3 , 0.1-0.2 M KF, and 1-2 g/L B achieved acceptable dissolution rates in the same temperature range. To confirm that conditions identified by the dissolution rate measurements for solutions containing Gd or B can be used to dissolve Pu metal up to 6.75 g/L in the presence of Fe, demonstration experiments were performed using concentrations in the optimal ranges. In two of the demonstration experiments using Gd and in one experiment using B, the offgas generation during the dissolution was measured and samples were analyzed for H 2 . The experimental methods used to perform the dissolution rate measurements and flowsheet demonstrations and a discussion of the results are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimal Estimation Retrievals and Their Uncertainties: What Every Atmospheric Scientist Should Know

Remote sensing instruments are heavily used to provide observations for both the operational and research communities. These sensors do not provide direct observations of the desired atmospheric variables, but instead, retrieval algorithms are necessary to convert the indirect observations into the variable of interest. It is critical to be aware of the underlying assumptions made by many retrieval algorithms, including that the retrieval problem is often ill posed and that there are various sources of uncertainty that need to be treated properly. In short, the retrieval challenge is to invert a set of noisy observations to obtain estimates of atmospheric quantities. The problem is often complicated by imperfect forward models, by imperfect prior knowledge, and by the existence of nonunique solutions. Optimal estimation (OE) is a widely used physical retrieval method that combines measurements, prior information, and the corresponding uncertainties based on Bayes’s theorem to find an optimal solution for the atmospheric state. Furthermore, OE also allows the relative contributions of the different sources of error to the uncertainty in the final retrieved atmospheric state to be understood. Here, we provide a novel Python library to illustrate the use of OE for inverse problems in the atmospheric sciences. We introduce two example problems: how to retrieve drop size distribution parameters from radar observations and how to retrieve the temperature profile from ground-based microwave sensors. Using these examples, we discuss common pitfalls, how the various error sources impact the retrieval, and how the quality of the retrieval results can be quantified.

54 ENVIRONMENTAL SCIENCES↗

State Dependent Optimization with Quantum Circuit Cutting

Quantum circuits can be reduced through optimization to better fit the constraints of quantum hardware. One such method, initial-state dependent optimization (ISDO), reduces gate count by leveraging knowledge of the input quantum states. Surprisingly, we found that ISDO is broadly applicable to the downstream circuits produced by circuit cutting. Circuit cutting also requires measuring upstream qubits and has some flexibility of selection observables to do reconstruction. Therefore, we propose a state-dependent optimization (SDO) framework that incorporates ISDO, our newly proposed measure-state dependent optimization (MSDO), and a biased observable selection strategy. Building on the strengths of the SDO framework and recognizing the scalability challenges of circuit cutting, we propose nonseparate circuit cutting-a more flexible approach that enables optimizing gates without fully separating them. We validate our methods on noisy simulations of QAOA, QFT, and BV circuits. Results show that our approach consistently mitigates noise and improves overall circuit performance, demonstrating its promise for enhancing quantum algorithm execution on near-term hardware.

Li, Xinpeng↗

Real-time Crystal Growth Visualization and Quantification by Energy-Resolved Neutron Imaging

Energy-resolved neutron imaging is investigated as a real-time diagnostic tool for visualization and in-situ measurements of "blind" processes. This technique is demonstrated for the Bridgman-type crystal growth enabling remote and direct measurements of growth parameters crucial for process optimization. The location and shape of the interface between liquid and solid phases are monitored in real-time, concurrently with the measurement of elemental distribution within the growth volume and with the identification of structural features with a ~100 μm spatial resolution. Such diagnostics can substantially reduce the development time between exploratory small scale growth of new materials and their subsequent commercial production. This technique is widely applicable and is not limited to crystal growth processes.

36 MATERIALS SCIENCE↗

Optimizing observables with machine learning for better unfolding

Most measurements in particle and nuclear physics use matrix-based unfolding algorithms to correct for detector effects. In nearly all cases, the observable is defined analogously at the particle and detector level. We point out that while the particle-level observable needs to be physically motivated to link with theory, the detector-level need not be and can be optimized. We show that using deep learning to define detector-level observables has the capability to improve the measurement when combined with standard unfolding methods.

47 OTHER INSTRUMENTATION↗