Sister Rod Destructive Examinations (FY23) Appendix C: Rod Internal Pressure, Void Volume, and Gas Transmission Tests

As a part of the DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWD/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called the sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin (LT) Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rod’s condition before dry storage and are focused on understanding overall SNF rod strength and durability. Both fuel rods and empty cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the postirradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and consolidation activities. This appendix documents the status of the ORNL Phase 1 DE activities related to rod internal pressure and void volume measurement techniques, fission gas stack flow measurements applied to selected sister rods, and fission gas release calculations in Phase 1 of the sister rod test program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enabling Digital Image Correlation for Deployment in the Hot Fuels Examination Facility

Digital image correlation (DIC) is a non-contact image-based technique for displacement and strain measurement. It is also a full-field method that can provide excellent spatial resolution. DIC has been widely used for measurements in many styles of mechanical tests and is desirable in part because of this flexibility to measure nearly any material across a range of time and length scales. Its ability to measure localized strain for tests and in environments not accessible to other strain measurement techniques makes it an ideal option for several mechanical test cases that exist in hot cell facilities such as the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). However, DIC has not been demonstrated at HFEF, and several barriers to implementation in the hot cell environment exist. This report outlines the possible paths for deploying DIC at HFEF, weighing the technical advantages and risks with each path. It also discusses the steps which must be taken to add this capability to the suite of post-irradiation examination (PIE) techniques available at HFEF. Finally, it concludes with recommendations for the best method to perform DIC at the facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A LENS on DUNE-PRISM: Characterizing a Neutrino Beam with Off-Axis Measurements

Upcoming precision long-baseline neutrino oscillation experiments will be severely limited by the large systematic uncertainties associated with neutrino flux predictions and neutrino--nucleus cross sections. A promising remedy is the PRISM (Precision Reaction Independent Spectrum Measurement) technique, whereby the near detector measures the neutrino spectrum at different angles with respect to the beam axis. These measurements are then linearly combined into a prediction of the oscillated neutrino flux at the far detector. This prediction is data-driven, but still dependent on some theoretical knowledge about the neutrino flux. In this paper, we study to what extent off-axis measurements themselves can be used to directly constrain neutrino flux models. In particular, we use them to extract separately the fluxes and spectra of different meson species in the beam. We call this measurement LENS (Lateral Extraction of Neutrino Spectra). Second, we demonstrate how the thus improved flux model helps to further constrain the far detector flux prediction, thereby ultimately improving oscillation measurements.

FOS: Physical sciences↗

Radiometry of water turbidity measurements

An examination of a number of measurements of turbidity reported in the literature reveals considerable variability in the definitions, units, and measurement techniques used. Many of these measurements differ radically in the optical quantity measured. The radiometric basis of each of the most common definitions of turbidity is examined. Several commercially available turbidimeters are described and their principles of operation are evaluated radiometrically. It is recommended that the term turbidity be restricted to measurements based upon the light scattered by the sample with that scattered by standard suspensions of known turbidity. It is also recommended that the measurement procedure be standardized by requiring the use of Formazin as the turbidity standardizing material and that the Formazin Turbidity Unit (FTU) be adopted as the standard unit of turbidity.

Mccluney, W. R.↗

A brief review of space flight calcium metabolism: Results and methodologies

Space flight induced osteoporosis was described. The techniques that were used to measure and detect the osteoporosis were also described. Areas of calcium metabolism were shown to be very important in the investigation into more sensitive detection and measurement techniques of bone demineralization.

Source record↗

Preliminary announcement of an 85 percent efficient reflector antenna

The aperture efficiency is defined in the usual way to include the spillovers, illumination, phase, and cross polarization efficiencies of the projected circular aperture. The antenna comprises a 157.1-lambda main reflector, a 47.1-lambda subreflector, and a 5.1-lambda aperture feedhorn. Both reflectors are shaped in such a way as to provide quasi-uniform aperture illumination with a degree of spillover control. By using an offset feed geometry, the configuration provides an unblocked main reflector. An analysis of expected performance yields a theoretical 86.5% aperture efficiency, whereas the measurement technique yields 84.9%. The estimated measurement tolerance is now + or - 3% (approximately + or - 0.15 dB) on a high confidence (approximately + or - 3sigma) basis.

Cha, A. G.↗

Diurnal variations of vegetation canopy structure

The significance and magnitude of diurnal variations of vegetation canopy structure are reviewed. Diurnal leaf inclination-azimuth angle distributions of a soybean and cotton canopy were documented using a simple measurement technique. The precision of the measurements was on the order of + or -5 deg for the inclination and + or -14 deg for the azimuth. The experimental results and a review of the literature showed that this distribution can vary significantly on a diurnal basis due to vegetation type, heliotropic leaf movement, environmental conditions, and vegetation stress. The study also showed that it is erroneous to treat two separate distributions of azimuth and inclination angles rather than one three-dimensional distribution of leaf orientation. The latter distribution needs to be routinely collected in studies which document variations of diurnal spectral reflectance with changes in solar zenith angle.

Kimes, D. S.↗

Intercomparison of stratospheric/mesospheric data; Proceedings of the Topical Meeting, Graz, Austria, June 25-July 7, 1984

Comparative analyses of various stratospheric and mesospheric species, including aerosols, ions, ozone, and some minor species, are presented, based on measurements obtained from rocket, balloon, aircraft, and satellite missions. In addition, studies concerning temperature and density characteristics of the stratosphere and mesosphere are included, as well as discussions on the various sensing and measurement techniques. Finally, dynamics and turbulence measurements are examined; consideration is given to radar winds, solar X-ray and HF radiowave absorption, and ionization irregularities.

Ghazi, A.↗

Laser Doppler velocimetry primer

Advanced research in experimental fluid dynamics required a familiarity with sophisticated measurement techniques. In some cases, the development and application of new techniques is required for difficult measurements. Optical methods and in particular, the laser Doppler velocimeter (LDV) are now recognized as the most reliable means for performing measurements in complex turbulent flows. And such, the experimental fluid dynamicist should be familiar with the principles of operation of the method and the details associated with its application. Thus, the goals of this primer are to efficiently transmit the basic concepts of the LDV method to potential users and to provide references that describe the specific areas in greater detail.

Bachalo, William D.↗

Global Reference Atmosphere Model-1988

Four-D Global Reference Atmosphere computer program (GRAM) developed from empirical mathematical model of atmosphere generating values for pressure, density, temperature, and winds from surface level to orbital altitudes. Generates altitude profiles of parameters of atmosphere along any simulated trajectory through atmosphere. Developed from design applications in Space Shuttle program. Other potential applications include studies of global circulation and diffusion and generation of profiles for comparison with results of other atmospheric-measurement techniques such as satellite-measured temperature profiles and wind profiles from infrasonic measurements. Written in STANDARD FORTRAN 77.

Johnson, D. L.↗

Quantitative three-dimensional low-speed wake surveys

Theoretical and practical aspects of conducting three-dimensional wake measurements in large wind tunnels are reviewed with emphasis on applications in low-speed aerodynamics. Such quantitative wake surveys furnish separate values for the components of drag, such as profile drag and induced drag, but also measure lift without the use of a balance. In addition to global data, details of the wake flowfield as well as spanwise distributions of lift and drag are obtained. The paper demonstrates the value of this measurement technique using data from wake measurements conducted by Boeing on a variety of low-speed configurations including the complex high-lift system of a transport aircraft.

Brune, G. W.↗

NASA EPSCoR Preparation Grant

The NASA EPSCoR project in Mississippi involved investigations into three areas of interest to NASA by researchers at the four comprehensive universities in the state. These areas involved: (1) Noninvasive Flow Measurement Techniques, (2) Spectroscopic Exhaust Plume Measurements of Hydrocarbon Fueled Rocket Engines and (3) Integration of Remote Sensing and GIS data for Flood Forecasting on the Mississippi Gulf Coast. Each study supported a need at the Stennis Space Center in Mississippi. The first two addressed needs in rocket testing, and the third, in commercial remote sensing. Students from three of the institutions worked with researchers at Stennis Space Center on the projects.

Sukanek, Peter C.↗

Anomalous Shocks on the Measured Near-Field Pressure Signatures of Low-Boom Wind-Tunnel Models

Unexpected shocks on wind-tunnel-measured pressure signatures prompted questions about design methods, pressure signature measurement techniques, and the quality of measurements in the flow fields near lifting models. Some of these unexpected shocks were the result of component integration methods. Others were attributed to the three-dimension nature of the flow around a lifting model, to inaccuracies in the prediction of the area-ruled lift, or to wing-tip stall effects. This report discusses the low-boom model wind-tunnel data where these unexpected shocks were initially observed, the physics of the lifting wing/body model's flow field, the wind-tunnel data used to evaluate the applicability of methods for calculating equivalent areas due to lift, the performance of lift prediction codes, and tip stall effects so that the cause of these shocks could be determined.

Mack, Robert J.↗

Near Real Time Prospecting for Lunar Volatiles: Demonstrating RESOLVE Science in the Field

The Regolith and Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) project aims to demonstrate the utility of "in situ resource utilization". In situ resource utilization (ISRU) is a way to rebalance the economics of spaceflight by reducing or eliminating materials that must be brought up from Earth and placed on the surface of the Moon for human use. RESOLVE is developing a rover-borne payload that (1) can locate near subsurface volatiles, (2) excavate and analyze samples of the volatile-bearing regolith, and (3) demonstrate the form, extractability and usefulness of the materials. Such investigations are important not only for ISRU but are also critically important for understanding the scientific nature of these intriguing lunar polar volatile deposits. Temperature models and orbital data suggest near surface volatile concentrations may exist at briefly lit lunar polar locations outside persistently shadowed regions. A lunar rover could be remotely operated at some of these locations for the 4-7 days of expected sunlight at relatively low cost. In July 2012 the RESOLVE project conducted a full-scale field demonstration. In particular, the ability to perform the real-time measurement analysis necessary to search for volatiles and the ability to combine the various measurement techniques to meet the mission measurement and science goals. With help from the Pacific International Space Center for Exploration Systems (PISCES), a lunar rover prototype (provided by the Canadian Space Agency) was equipped with prospecting instruments (neutron spectrometer and near-infrared spectrometer), subsurface access and sampling tools, including both an auger and coring drill (provided by CSA) and subsurface sample analysis instrumentation, including a sample oven system, the Oxygen and Volatile Extraction Node (OVEN), and Gas Chromatograph / Mass Spectrometer system, the Lunar Advanced Volatile Analysis (LAVA) system. Given the relatively short time period this lunar mission is being designed to, prospecting needs to occur in near real-time. The two prospecting instruments are the neutron and NIR spectrometers. In the field demo a small radioactive source was provided the neutron flux. The NIR spectrometer, which includes its own light source, looks at surface reflectance for signatures of bound H20/0H and general mineralogy. Once a "hot spot" was found by the prospecting instruments, the drill could either auger or core. The auger drill worked to a depth of 50 cm and is monitored with a drill camera and the NIR spectrometer. As cuttings are brought up the NIR spectra is monitored. If a particular location is considered of high -interest then the decision to core could be made. The coring drill (a push-tube) allowed a meter sample to be acquired processed by the OVEN/LAVA sys-tem. This presentation will provide details as how these instruments worked together and how and if the planned measurements and science was obtained.

Elphic, Richard↗

AVNG system objectives and concept

Any verification measurement performed on potentially classified nuclear material must satisfy two constraints. First and foremost, no classified information can be released to the monitoring party. At the same time, the monitoring party must gain sufficient confidence from the measurement to believe that the material being measured is consistent with the host's declarations concerning that material. The attribute measurement technique addresses both concerns by measuring several attributes of the nuclear material and displaying unclassified results through green (indicating that the material does possess the specified attribute) and red (indicating that the material does not possess the specified attribute) lights. The AVNG that we describe is an attribute measurement system built by RFNC-VNIIEF in Sarov, Russia. The AVNG measures the three attributes of 'plutonium presence,' 'plutonium mass >2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) <0.1' and was demonstrated in Sarov for a joint US/Russian audience in June 2009. In this presentation, we will outline the goals and objectives of the AVNG measurement system. These goals are driven by the two, sometimes conflicting, requirements mentioned above. We will describe the conceptual design of the AVNG and show how this conceptual design grew out of these goals and objectives.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of the $t\bar{t}$ Production Cross Section with an in situ Calibration of $b$-jet Identification Efficiency

A measurement of the top-quark pair-production cross section in p{bar p} collisions at {radical}s = 1.96 TeV using data corresponding to an integrated luminosity of 1.12 fb{sup -1} collected with the Collider Detector at Fermilab is presented. Decays of top-quark pairs into the final states e{nu} + jets and {mu}{nu} + jets are selected, and the cross section and the b-jet identification efficiency are determined using a new measurement technique which requires that the measured cross sections with exactly one and multiple identified b-quarks from the top-quark decays agree. Assuming a top-quark mass of 175 GeV/c{sup 2}, a cross section of 8.5 {+-} 0.6(stat.) {+-} 0.7(syst.) pb is measured.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Profiles of fatigue damage in graphite/epoxy composites from ultrasonic transmission power spectra

Early fatigue damage in non-unidirectional multi-ply graphite/epoxy composites is manifested by a distribution of cracks and disbonds through the bulk of the material. Such damage is subtle and is difficult to detect with conventional ultrasonic technology. Consequently, a new ultrasonic measurement technique called phase-insensitive tone-burst spectroscopy has been developed. The new technique eliminates problems associated with phase cancellation and pulse shape artifacts inherent to conventional broadband ultrasonic spectral measurement systems and produces clean spectral information irrespective of specimen inhomogeneity or irregularities in surface geometry. Application of the new technique to measurements of graphite/epoxy composites has yielded frequency-domain profiles that show distinct differences in ultrasonic attenuation, attenuation slope, and velocity for each specimen experiencing a different level of fatigue damage.

Cantrell, J. H., Jr.↗

Instantaneous velocity field imaging instrument for supersonic reacting flows

The technical tasks conducted to develop and demonstrate a new gas velocity measurement technique for high enthalpy reacting flows is described. The technique is based on Doppler-shifted Planar Laser-induced Fluorescence (PLIF) imaging of the OH radical. The imaging approach permits, in principle, single-shot measurements of the 2-D distribution of a single velocity component in the measurement plane, and is thus a technique of choice for applications in high enthalpy transient flow facilities. In contrast to previous work in this area, the present program demonstrated an approach which modified the diagnostic technique to function under the constraints of practical flow conditions of engineering interest, rather than vice-versa. In order to accomplish the experimental demonstrations, the state-of-the-art in PLIF diagnostic techniques was advanced in several ways. Each of these tasks is described in detail and is intended to serve as a reference in supporting the transition of this new capability to the fielded PLIF instruments now installed at several national test facilities. Among the new results of general interest in LlF-based flow diagnostics, a detailed set of the first measurements of the collisional broadening and shifting behavior of OH (1,0) band transitions in H7-air combustion environments is included. Such measurements are critical in the design of a successful strategy for PLIF velocity imaging; they also relate to accurate concentration and temperature measurements, particularly in compressible flow regimes. Furthermore, the results shed new light on the fundamental relationship between broadening and energy transfer collisions in OH A(sup 2)Sigma(+)v(sup ') = 1. The first single-pulse, spectrally-resolved measurements of the output of common pulsed dye lasers were also produced during the course of this effort. As with the OH broadening measurements, these data are a significant aspect of a successful velocity imaging strategy, and also have potential implications for many other LIF measurement techniques. Our results indicated the need to modify the commercially available laser cavity in order to accommodate the constraints imposed by typical SCRAMJET combustion characteristics as well as to increase the instrument's velocity dynamic range to span an intra-image range in excess of 2 km/s. The various technical efforts were brought together in a series of experiments demonstrating the applicability of the technique in a high pressure, high temperature H2-air combustion system. The resultant images were compared with 2-D flow simulations in order to determine the accuracy of the instrument. Mean velocity imaging in flows with an axis of symmetry was demonstrated with an accuracy of +/- 50 m/s out of an intra-image dynamic range of 1600 m/s, including reversed flow. A more complex configuration amenable to single-shot imaging in flows without an axis of symmetry was also demonstrated. Limitations imposed by available equipment resulted in an accuracy of about +/- 200 m/s out of 1750 m/s in these demonstrations. Minor modifications to the present configuration were suggested to improve this performance. Each technical task is described in detail, along with significance of the results for the overall imaging velocimeter configuration. This report should allow the user community to integrate this new measurement capability in their existing instrumentation platforms.