Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Second-order many-body perturbation and coupled-cluster singles and doubles study of ice VIII

The structure, equation of state, IR, Raman, and inelastic neutron scattering (INS) spectra of high-pressure, proton-ordered phase VIII of ice are calculated by the second-order many-body perturbation and coupled-cluster singles and doubles methods. Nearly all the observed features of the pressure-dependence of the structures and spectra are reproduced computationally up to 60 GPa insofar as the anharmonic effects can be neglected. The calculations display no sign of the hypothetical isostructural transition in 2–3 GPa to phase VIII{sup ′}, the existence of which has been a matter of controversy for over a decade, while they do not contradict the interpretation of the spectral anomaly at 10–14 GPa as a precursor of the VIII-X phase transition. The calculated INS spectra correct a systematic error in the peak positions of the observed spectra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Facility for fast neutron irradiation tests of electronics at the ISIS spallation neutron source

The VESUVIO beam line at the ISIS spallation neutron source was set up for neutron irradiation tests in the neutron energy range above 10 MeV. The neutron flux and energy spectrum were shown, in benchmark activation measurements, to provide a neutron spectrum similar to the ambient one at sea level, but with an enhancement in intensity of a factor of 10{sup 7}. Such conditions are suitable for accelerated testing of electronic components, as was demonstrated here by measurements of soft error rates in recent technology field programable gate arrays.

43 PARTICLE ACCELERATORS↗

Inelastic and deep inelastic neutron spectroscopy of water molecules under ultra-confinement

Water confined within sub-nanometer channels of silicate minerals presents an extreme case of confinement, where the restricted molecules are situated in channels whose diameter is not much larger than the water molecule itself. Recently, we discovered a new quantum tunneling state of the water molecule confined in 5 Å channels in the mineral beryl, characterized by extended proton and electron delocalization. Several peaks were observed in the inelastic neutron scattering (INS) spectra which were uniquely assigned to water quantum tunnelling. In addition, the water proton momentum distribution measured with deep inelastic neutron scattering (DINS) at 4.3 K directly showed coherent delocalization of the water protons in the ground state. The obtained average kinetic energy (EK ) of the water protons was found to be ~30% less than it is in bulk liquid water and ice phases. In the current work we present INS and DINS study of water in single crystal beryl in wider temperature range, T=5–260 K, where we observed significant increase of EK of the confined water protons with temperature increase. The obtained INS data also indicate that with increasing temperature water molecules are progressively involved in hydrogen bonding (HB) with the beryl cage, while HB is almost absent at low temperatures.

Kolesnikov, Alexander I.↗

RELATIVISTIC LINES AND REFLECTION FROM THE INNER ACCRETION DISKS AROUND NEUTRON STARS

A number of neutron star low-mass X-ray binaries (LMXBs) have recently been discovered to show broad, asymmetric Fe K emission lines in their X-ray spectra. These lines are generally thought to be the most prominent part of a reflection spectrum, originating in the inner part of the accretion disk where strong relativistic effects can broaden emission lines. We present a comprehensive, systematic analysis of Suzaku and XMM-Newton spectra of 10 neutron star LMXBs, all of which display broad Fe K emission lines. Of the 10 sources, 4 are Z sources, 4 are atolls, and 2 are accreting millisecond X-ray pulsars (also atolls). The Fe K lines are fit well by a relativistic line model for a Schwarzschild metric, and imply a narrow range of inner disk radii (6-15 GM/c {sup 2}) in most cases. This implies that the accretion disk extends close to the neutron star surface over a range of luminosities. Continuum modeling shows that for the majority of observations, a blackbody component (plausibly associated with the boundary layer) dominates the X-ray emission from 8 to 20 keV. Thus it appears likely that this spectral component produces the majority of the ionizing flux that illuminates the accretion disk. Therefore, we also fit the spectra with a blurred reflection model, wherein a blackbody component illuminates the disk. This model fits well in most cases, supporting the idea that the boundary layer illuminates a geometrically thin disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Use of MCNP + GADRAS in Generating More Realistic Gamma-Ray Spectra for Plutonium and HEU Objects

The ability to accurately simulate high-resolution gamma spectra from materials that emit both neutrons and gammas is very important to the analysis of special nuclear materials (SNM), e.g., uranium and plutonium. One approach under consideration has been to combine MCNP and GADRAS. This approach is expected to generate more accurate gamma ray spectra for complex three-dimensional geometries than can be obtained from one-dimensional deterministic transport simulations (e.g., ONEDANT). This presentation describes application of combining MCNP and GADRAS in simulating plutonium and uranium spectra.

07 ISOTOPE AND RADIATION SOURCES↗

Improvements in transport calculations by the optimized multigroup libraries for fast neutron systems

This paper shows how to improve the accuracy of the transport calculations using in the APOLLO2 code the optimized multigroup libraries calculated by AEMC for fast neutron systems. These ameliorations concern the fission source calculation and the self-shielding models. The calculation of the fission source was generalized to fission spectra including an incident neutron energy dependence. The subgroup self-shielding model was updated for a mixture of resonant nuclides. Some tests on a Pu-239 sphere without reflectors and a fast sodium cell show that the use of four fission spectra guarantees a correct representation of the fission source. The test on a Pu-239 sphere with a thick steel reflector proves that the subgroup self-shielding, accounting for the mutual shielding of several resonant nuclides, allows us to improve the accuracy of the neutron transport solution in the reflector. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

Calculation of vibrational spectra of an icosahedral quasicrystal AlCuFe

Vibrational spectra of an icosahedral quasicrystal AlCuFe have been calculated on the basis of a crystalline 1/1 approximant by the recurrence method. To describe the interaction of atoms in a quasicrystal, the semiempirical EAM model was used. It is shown that the calculated spectra are in satisfactory agreement with the experimental neutron inelastic scattering data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

LEIA: An Investigation of Radiation Risks to Biology at the Lunar South Pole

Radiation and reduced gravity pose biological risks to crewed deep space exploration. At the cellular level, radiation damage can be amplified by reduced gravity. Empirical evidence on cellular responses to beyond low Earth orbit (BLEO) environments is imperative to develop effective countermeasures for crew health and in-space biomanufacturing. The Lunar Explorer Instrument for Space Biology Applications (LEIA) project is developing an instrument suite to be delivered to the south polar region of the Moon by the Commercial Lunar Payload Services (CLPS) program. This presentation will provide an overview of the LEIA hardware, experiments, and mission timeline. The LEIA instruments include the BioSensor, the ARES charged particle detector, and the Mini-FND. The BioSensor is an autonomous light emitting diode (LED)-based spectrophotometer and microfluidic incubator. The BioSensor activates yeast cultures and can measure cell growth, metabolic activity, and carotenoid production. The ARES is a Timepix-based charged particle radiation detector that measures dose, dose rate, and linear energy transfer spectra. The Mini-FND is a fast neutron detector that measures albedo neutron flux and energy spectra. Combined, these instruments will be used for yeast genetics experiments to quantify growth, metabolism, and synthetic biology-enabled production of human nutrients, while taking real time measurements of biologically relevant radiation exposure on the lunar surface. These data will be used to test the importance of selected DNA damage repair and reactive oxygen species defense pathways in mitigating cellular damage from lunar surface radiation.

Yeast↗

LEIA: An Investigation of Radiation Risks to Biology at the Lunar South Pole

Radiation and reduced gravity pose biological risks to crewed deep space exploration. At the cellular level, radiation damage can be amplified by reduced gravity. Empirical evidence on cellular responses to beyond low Earth orbit (BLEO) environments is imperative to develop effective countermeasures for crew health and in-space biomanufacturing. The Lunar Explorer Instrument for Space Biology Applications (LEIA) project is developing an instrument suite to be delivered to the south polar region of the Moon by the Commercial Lunar Payload Services (CLPS) program. This presentation will provide an overview of the LEIA hardware, experiments, and mission timeline. The LEIA instruments include the BioSensor, the ARES charged particle detector, and the Mini-FND. The BioSensor is an autonomous light emitting diode (LED)-based spectrophotometer and microfluidic incubator. The BioSensor activates yeast cultures and can measure cell growth, metabolic activity, and carotenoid production. The ARES is a Timepix-based charged particle radiation detector that measures dose, dose rate, and linear energy transfer spectra. The Mini-FND is a fast neutron detector that measures albedo neutron flux and energy spectra. Combined, these instruments will be used for yeast genetics experiments to quantify growth, metabolism, and synthetic biology-enabled production of human nutrients, while taking real time measurements of biologically relevant radiation exposure on the lunar surface. These data will be used to test the importance of selected DNA damage repair and reactive oxygen species defense pathways in mitigating cellular damage from lunar surface radiation.

Yeast↗

Study on generating of thermal neutron scattering cross sections for LiH

LiH is designated as a promising moderator and shielding material because of its low density, high melting point and large fraction of H atoms. However, lack of the thermal neutron cross sections of LiH makes numerical calculation deviate from experimental data to some extent. As a result, it is necessary to study LiH thermal kernel effect. The phonon property of LiH has been investigated by first-principles calculations using the plane-wave pseudo potential method with CASTEP code. The scattering law and the thermal neutron scattering cross sections for Li and H have been generated using this distribution. The results have been compared with zirconium hydride data. The GASKET and NJOY/LEAPR codes have been used in the calculation of scattering law, whose results have been compared with the reference; the discrepancy mainly comes from phonon spectrums and its expansion. LEAPR had the capability to compute scattering through larger energy and momentum transfers than GASKET did. By studying LiH phonon spectrum and constructing the model of LiH thermal kernel and scattering matrix, the ACE format LiH thermal neutron cross sections for MCNP software could be made and used for reactor Neutronics calculation. (authors)

36 MATERIALS SCIENCE↗

Event-by-Event Evaluation of the Prompt Fission Neutron Spectrum From 239 Pu(n,f)

We have developed an improved evaluation method for the spectrum of neutrons emitted in fission of 239 Pu induced by incident neutrons with energies up to 20 MeV. The <v> covariance data, including incident energy correlations introduced by the <v> evaluation method, were used to fix the input parameters in our event-by-event model of fission, FREYA, by applying formal statistical methods. Formal estimates of uncertainties in the evaluation were developed by randomly sampling model inputs and calculating likelihood functions based on agreement with the evaluated <v>. Our approach is able to employ a greater variety of fission measurements than the relatively coarse spectral data alone. It also allows the study of numerous fission observables for more accurate model validation. The combination of an event-by-event Monte Carlo fission model with a statistical-likelihood analysis is thus a powerful tool for evaluation of fission-neutron data. Our empirical model FREYA follows the complete fission event from birth of the excited fragments through their decay via neutron emission until the fragment excitation energy is below the neutron separation energy when neutron emission can no longer occur. The most recent version of FREYA incorporates pre-equilibrium neutron emission, the emission of the first neutron before equilibrium is reached in the compound nucleus, and multi-chance fission, neutron evaporation prior to fission when the incident neutron energy is above the neutron separation energy. Energy, momentum, charge and mass number are conserved throughout the fission process. The best available values of fragment masses and total kinetic energies are used as inputs to FREYA. We fit three parameters that are not well under control from previous measurements: the shift in the total fragment kinetic energy; the energy scale of the asymptotic level density parameter, controlling the fragment 'temperature' for neutron evaporation; and the relative excitation of the light and heavy fragments, governing the number and energy of neutrons emitted from each fragment. The latter two parameters are assumed to be independent of the incident neutron energy while the first varies with incident energy. We describe our method and the subsequent spectral evaluation and present the results of several standard validation calculations that test our new evaluation. These benchmarks include critical assemblies, sensitive to criticality in fast systems; pulsed sphere measurements testing the spectra at incident neutron energies of 14 MeV; and other tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Prompt and Delayed Inelastic Scattering Reactions from Fission Neutron PGAA - First Results of FaNGaS

The new instrument Fast Neutron Gamma Spectroscopy (FaNGaS) has been installed at the SR10 beam line of the FRM II Research Reactor in Garching and tested successfully. Complimentary to cold neutron PGAA, with FaNGaS inelastic scattering reactions induced by fission neutrons can be studied. Gamma lines from (n,n'γ) reactions up to now have been rarely studied and no adequate compilation of the emitted gamma energies exist. In developing nondestructive analytical techniques using neutron generator based PGAA such data are badly needed for quantification of heavy metals and actinides in e.g. nuclear waste or safeguards samples. A number of elements and relevant actinides have been irradiated in the fast neutron beam SR10 at the FRM II reactor in Garching, Germany. A heavily shielded 50% eff. HPGe detector perpendicular to the beam is looking at the samples exposed to 2.3 E8 cm{sup -2}s{sup -1} fission neutrons. Prompt gamma spectra have been taken and evaluated using the available data in scattered sources. Additional gamma lines have been detected and are being compiled to create a data base for (n,n') reactions. Particular emphasis is given on actinides including {sup 238}U, {sup 232}Th, {sup 237}Np, {sup 242}Pu and {sup 241}Am. Some examples will be given and first results will be discussed in this contribution. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RX J1856.5-3754: A Strange Star with Solid Quark Surface?

The featureless spectra of isolated 'neutron stars' may indicate that they are actually bare strange stars but a definitive conclusion on the nature of the compact objects cannot be reached until accurate and theoretically calculated spectra of the bare quark surface are known. However due to the complex nonlinearity of quantum chromodynamics it is almost impossible to present a definitive and accurate calculation of the density-dominated quark-gluon plasma from the first principles. Nevertheless it was suggested that cold quark matter with extremely high baryon density could be in a solid state. Within the realms of this possibility we have fitted the 500ks Chandra LETG/HRC data for the brightest isolated neutron star RX 51856.5-3754 with a phenomenological spectral model and found that electric conductivity of quark matter on the stellar surface is about 1.5 x 10(exp 16)/s.

Zhang, Xiaoling↗

Spectra from nuclear-excited plasmas

The paper discusses the spectra taken from He-3(n,p)H-3 nuclear-induced plasmas under high thermal neutron flux, lasing conditions. Also, initial spectra are presented for U-235F6 generated plasmas. From an evaluation of these spectra, important atomic and molecular processes that occur in the plasma can be inferred. The spectra presented are the first to be generated by He-3 and U-235F6 nuclear reactions under high neutron flux, lasing conditions. The U-235(n,ff)FF reaction, which liberates 165 MeV of fission-fragment kinetic energy, creates plasmas that are of great interest, since at sufficiently high densities of U-235F6 the gas becomes self-critical; thus, there is no need for an external driving reactor (source of neutrons). The spectra from mixtures of He-3 and Ar, Xe, Kr, Ne, Cl2, F2 and N2 indicate little difference between high-pressure nuclear-induced plasmas and high-pressure electrically pulsed afterglow plasmas for noble-gas systems

De Young, R. J.↗

Thermal Neutron Die-Way-Time Studies for P and DGNAA of Radioactive Waste Drums at the MEDINA Facility

In Germany, radioactive waste with negligible heat production has to pass through a process of quality checking in order to check its conformance with national regulations prior to its transport, intermediate storage and final disposal. Additionally to its radioactive components, the waste may contain non-radioactive chemically toxic substances that can adversely affect human health and pollute the environment, especially the ground water. After an adequate decay time, the waste radioactivity will become harmless but the non-radioactive substances will persist over time. In principle, these hazardous substances may be quantified from traceability and quality controls performed during the production of the waste packages. As a consequence, a research and development program was initiated in 2007 with the aim to develop a nondestructive analytical technique for radioactive waste packages based on prompt and delayed gamma neutron activation analysis (P and DGNAA) employing a DT-neutron generator in pulsed mode. In a preliminary study it was experimentally demonstrated that P and DGNAA is suitable to determine the chemical composition of large samples. In 2010 a facility called MEDINA (Multi Element Detection based on Instrumental Neutron Activation) was developed for the qualitative and quantitative determination of nonradioactive, toxic elements and substances in 200-l steel drums. The determination of hazardous substances and elements is generally achieved measuring the prompt gamma-rays induced by thermal neutrons. Additional information about the composition of the waste matrix could be derived measuring the delayed gamma-rays from short life activation products. However a sensitive detection of these delayed gamma-rays requires that thermal neutrons have almost vanished. Therefore, the thermal neutron die-away-time has to be known in order to achieve an optimal discrimination between prompt and delayed gamma-ray spectra acquisition. Measurements Thermal neutron die-away times have been determined for the following cases: a) the empty chamber, b ) an empty 200-l steel drum, for a 200-l steel drum filled c) with concrete d) with polyethylene and e) with a mixture of polyethylene and concrete by measuring the prompt-gamma ray count rate of relevant isotopes like of {sup 1}H, {sup 10}B, {sup 12}C, {sup 28}Si, {sup 35}Cl, {sup 40}Ca and {sup 56}Fe which are emitted from different parts of the facility and the sample. Additionally, the average die-away-time was determined from the total detector count rate. The neutron generator was operated with a neutron emission of 8x10{sup 7} n.s{sup -1}, a neutron pulse with a length of 250 μs and a repetition time of 5 ms. The spectra were acquired between the neutron pulses over t{sub c}=500 μs after a pre-defined waiting time t{sub D} (multiple of 500 μs). The thermal neutron die-away time was ranging between 0.9 ms and 5 ms according to the sample composition. As an example the measured thermal neutron die-away-time Λ [μs] of a drum filled with concrete is presented. Detailed results of this study will be presented and discussed. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low temperature synthesis of {tau}-zirconium hydrogenophosphate [{tau}-Zr(HPO{sub 4}){sub 2}] and a new sodic form obtained by ion exchange

A new method for the synthesis of 3-D {tau}-zirconium hydrogenophosphate (TZP) was developed using solid-state reactions at low temperature and atmospheric pressure in a nitrogen atmosphere in a two-hour reaction time. The characterization of the compound was performed using X-ray diffraction, infrared spectroscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy, differential scanning calorimetric, thermochemical analysis and X-ray photoelectron spectroscopy. A sodic form of the compound obtained by the immersion of TZP in a sodium hydroxide solution was characterized using the same techniques along with neutron activation analysis. The XPS spectra confirm the binding energy value for sodium-oxygen, and the XRD diffraction reveals the formation of a new sodium compound. - Graphical abstract: DRX, XPS and MEB of {tau}-zirconium hydrogenophosphate and its sodic form on the surface of TZP. Highlights: Black-Right-Pointing-Pointer New method for the syntheses of 3-D {tau}-zirconium hydrogenophosphate (TZP). Black-Right-Pointing-Pointer A sodic form of the TZP was obtained by the immersion of TZP in a sodium hydroxide. Black-Right-Pointing-Pointer The sodium compound is only formed on the TZP surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Partial Charge Collection Induced by Neutron Damage in High-Purity Germanium Detectors

This paper investigates the correlation of damage induced by neutron interactions and degradation in the spectra of HPGe detectors. As neutrons kinetically interact with germanium crystals, they create interstitial and vacancy defects within the lattice. These defects then interfere with the charge migration of electron-hole pairs and reduce resolution in the observed energy spectrum. The partial charge collection produces observable spectral changes by increasing the peak width and reducing resolution (full width half maximum). A detailed characterization using various check sources was performed before and after iterations of neutron exposure in order to observe the effects of the neutron damage. An additional set of measurements was performed along with characterizations to show the detector’s response at discrete locations on the HPGe crystal. This was done to observe how the spectrum changes when the gamma rays are isolated to regions of various thicknesses of germanium. In order to impart damage, the detector was placed inside a californium shuffler with the face of the detector against the guide tube for the 252 Cf source. For irradiation of the HPGe, the source was then positioned in front of the face of the detector using the stepper motor of the shuffler. The neutron exposure time intervals were recorded and increased based on the initial damage observed. An MCNP simulation was performed to estimate the amount of interactions that occurred in the germanium crystal to ensure enough damage had occurred. Studying the effects that neutron damage imparts on a bullet-type HPGe detector can help provide necessary data to estimate total neutron exposure limits, reduce the likelihood of decisions made on suspect data, and aid in diagnostics of a damaged detector.

36 MATERIALS SCIENCE↗