Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Recent progress on spherical torus research

The spherical torus or spherical tokamak (ST) is a member of the tokamak family with its aspect ratio (A = R{sub 0}/a) reduced to A ∼ 1.5, well below the normal tokamak operating range of A ≥ 2.5. As the aspect ratio is reduced, the ideal tokamak beta β (radio of plasma to magnetic pressure) stability limit increases rapidly, approximately as β ∼ 1/A. The plasma current it can sustain for a given edge safety factor q-95 also increases rapidly. Because of the above, as well as the natural elongation κ, which makes its plasma shape appear spherical, the ST configuration can yield exceptionally high tokamak performance in a compact geometry. Due to its compactness and high performance, the ST configuration has various near term applications, including a compact fusion neutron source with low tritium consumption, in addition to its longer term goal of an attractive fusion energy power source. Since the start of the two mega-ampere class ST facilities in 2000, the National Spherical Torus Experiment in the United States and Mega Ampere Spherical Tokamak in UK, active ST research has been conducted worldwide. More than 16 ST research facilities operating during this period have achieved remarkable advances in all fusion science areas, involving fundamental fusion energy science as well as innovation. These results suggest exciting future prospects for ST research both near term and longer term. The present paper reviews the scientific progress made by the worldwide ST research community during this new mega-ampere-ST era.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and Characterization of a High-Energy Neutron Time-of-Flight Imaging System

We present that Los Alamos National Laboratory has developed a prototype of a high-energy neutron time-of-flight imaging system for the non-destructive evaluation of dense, massive, and/or high atomic number objects. High-energy neutrons provide the penetrating power, and thus the high dynamic range necessary to image internal features and defects of such objects. The addition of the time gating capability allows for scatter rejection when paired with a pulsed monoenergetic beam, or neutron energy selection when paired with a pulsed broad-spectrum neutron source. The Time Gating to Reject Scatter and Select Energy (TiGReSSE) system was tested at the Los Alamos Neutron Science Center’s (LANSCE) Weapons Nuclear Research (WNR) facility, a spallation neutron source, to provide proof of concept measurements and to characterize the instrument response. This paper will show results of several objects imaged during this run cycle. In addition, results from system performance metrics such as the Modulation Transfer Function and the Detective Quantum Efficiency measured as a function of neutron energy, characterize the current system performance and inform the next generation of neutron imaging instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing {theta}{sub 23} in neutrino telescopes

Among all neutrino mixing parameters, the atmospheric neutrino mixing angle {theta}{sub 23} introduces the strongest variation on the flux ratios of ultrahigh-energy neutrinos. We investigate the potential of these flux ratio measurements at neutrino telescopes to constrain {theta}{sub 23}. We consider astrophysical neutrinos originating from pion, muon-damped, and neutron sources and make a comparative study of their sensitivity reach to {theta}{sub 23}. It is found that neutron sources are most favorable for testing deviations from maximal {theta}{sub 23}. Using a {chi}{sup 2} analysis, we show, in particular, the power of combining (i) different flux ratios from the same type of source, and also (ii) combining flux ratios from different astrophysical sources. We include in our analysis 'impure' sources, i.e., deviations from the usually assumed initial (1 ratio 2 ratio 0), (0 ratio 1 ratio 0), or (1 ratio 0 ratio 0) flux compositions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wavelength-Shifting-Fiber Scintillation Detectors for Thermal Neutron Imaging at SNS

We have developed wavelength-Shifting-fiber Scintillator Detector (SSD) with 0.3 m2 area per module. Each module has 154 x 7 pixels and a 5 mm x 50 mm pixel size. Our goal is to design a large area neutron detector offering higher detection efficiency and higher count-rate capability for Time-Of-Flight (TOF) neutron diffraction in Spallation Neutron Source (SNS). A ZnS/6LiF scintillator combined with a novel fiber encoding scheme was used to record the neutron events. A channel read-out-card (CROC) based digital-signal processing electronics and position-determination algorithm was applied for neutron imaging. Neutron-gamma discrimination was carried out using pulse-shape discrimination (PSD). A sandwich flat-scintillator detector can have detection efficiency close to He-3 tubes (about 10 atm). A single layer flat-scintillator detector has count rate capability of 6,500 cps/cm2, which is acceptable for powder diffractometers at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Transmutation of Nuclear Waste in the Two-Zone Subcritical System Driven by High- Intensity Neutron Generator - 12098

The main problems of transmutation of high-level radioactive waste (minor actinides and long-lived fission products) are considered in our work. The range of radioactive waste of nuclear power is analyzed. The conditions under which the transmutation of radioactive waste will be most effective are analyzed too. The modeling results of a transmutation of the main radioactive isotopes are presented and discussed. The transmutation of minor actinides and long-lived fission products are modeled in our work (minor actinides - Np-237, Am-241, Am-242, Am-243, Cm-244, Cm-245; long-lived fission products - I-129, Tc-99). The two-zone subcritical system is calculated with help of different neutron-physical codes (MCNP, Scale, Montebarn, Origen). The ENDF/B-VI nuclear data library used in above calculations. Thus, radioactive wastes can be divided into two main groups that need to be transmuted. The minor actinides form the first group and the long-lived fission products form the second one. For the purpose of effective transmutation these isotopes must be extracted from the spent nuclear fuel with the help of either PUREX technology or pyrometallurgical technology. The two-zone reactor system with fast and thermal regions is more effective for nuclear waste transmutation than the one-zone reactor. Modeling results show that nearly all radioactive wastes can be transmuted in the two-zone subcritical system driven by a high-intensity neutron generator with the external neutron source strength of 1.10{sup 13} n/sec. Obviously, transmutation rate will increase with a rise of the external neutron source strength. From the results above we can also see that the initial loading of radioactive isotopes into the reactor system should exceed by mass those isotopes that are finally produced. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutron Cross Section Measurements at ORELA for Improved Nuclear Data and Their Application

Many older neutron cross-section evaluations from libraries such as ENDF/B-VI or JENDL-3.2 exhibit deficiencies or do not cover energy ranges that are important for criticality safety applications. These deficiencies may occur in the resolved and unresolved-resonance regions. Consequently, these evaluated data may not be adequate for nuclear criticality calculations where effects such as self-shielding, multiple scattering, or Doppler broadening are important. To support the Nuclear Criticality Predictability Program, neutron cross-section measurements have been initiated at the Oak Ridge Electron Linear Accelerator (ORELA). ORELA is the only high-power white neutron source with excellent time resolution still operating in the United States. It is ideally suited to measure fission, neutron total, and capture cross sections in the energy range from 1 eV to {approx}600 keV, which is important for many nuclear criticality safety applications.

43 PARTICLE ACCELERATORS↗

Californium-252 neutron capture and decay methods for elemental analysis

The feasibility of using a Cf-252 neutron source in conjunction with a capture and/or decay gamma ray method for elemental analysis on lunar or planetary missions was tested. The general problems of using a Cf-252 neutron source for both decay and capture gamma ray analysis in terrestrial environments included the determination of the capture gamma ray spectra by neutron absorption in various metals used for the space hardware, Cf-252 source encapsulation materials, shielding, geometry, and optimum source size for a space mission. Computer data reduction and data transmission techniques were also investigated.

Source record↗

RAMPING UP THE SNS BEAM CURRENT WITH THE LBNL BASELINE H- SOURCE

Over the last two years the Spallation Neutron Source (SNS) has ramped up the repetition rate, pulse length, and the beam current to reach 540 kW, which has challenged many subsystems including the H- source designed and built by Lawrence Berkeley National Laboratory (LBNL). This paper discusses the major modifications of the H- source implemented to consistently and routinely output the beam current required by the SNS beam power ramp up plan. At this time, 32 mA LINAC beam current are routinely produced, which meets the requirement for 690 kW planned for end of 2008. In June 2008, a 14-day production run used 37 mA, which is close to the 38 mA required for 1.44 MW. A medium energy beam transport (MEBT) beam current of 46 mA was demonstrated on September 2, 2008.

43 PARTICLE ACCELERATORS↗

Detecting cavitation in mercury exposed to a high-energy pulsed proton beam

The Oak Ridge National Laboratory Spallation Neutron Source employs a high-energy pulsed proton beam incident on a mercury target to generate short bursts of neutrons. Absorption of the proton beam produces rapid heating of the mercury, resulting in the formation of acoustic shock waves and the nucleation of cavitation bubbles. The subsequent collapse of these cavitation bubbles promote erosion of the steel target walls. Preliminary measurements using two passive cavitation detectors (megahertz-frequency focused and unfocused piezoelectric transducers) installed in a mercury test target to monitor cavitation generated by proton beams with charges ranging from 0.041 to 4.1 C will be reported on. Cavitation was initially detected for a beam charge of 0.082 C by the presence of an acoustic emission approximately 250 s after arrival of the incident proton beam. This emission was consistent with an inertial cavitation collapse of a bubble with an estimated maximum bubble radius of 0.19 mm, based on collapse time. The peak pressure in the mercury for the initiation of cavitation was predicted to be 0.6 MPa. For a beam charge of 0.41 C and higher, the lifetimes of the bubbles exceeded the reverberation time of the chamber (~300 s), and distinct windows of cavitation activity were detected, a phenomenon that likely resulted from the interaction of the reverberation in the chamber and the cavitation bubbles.

36 MATERIALS SCIENCE↗

Computing the moments of the neutron population using deterministic neutron transport

It is important to treat the inherent stochasticity of the fission process in systems where the behavior of the system is stochastic. This occurs when there are few neutrons in the system, or when the neutron source is weak. In order to characterize such systems, the capability to compute the first four moments of the neutron population distribution has been added to the deterministic neutral particle transport code, PARTISN. The moments are then fitted to probability density functions from the Pearson family. PARTISN is compared against MCNP6, with which it agrees well. (authors)

97 MATHEMATICS AND COMPUTING↗

Los Alamos Neutron Science Center (LANSCE) Nuclear Science Facilities

The Los Alamos Neutron Science Center (LANSCE) facilities for Nuclear Science consist of a high-energy "white" neutron source (Target 4) with 6 flight paths, three low-energy nuclear science flight paths at the Lujan Center, and a proton reaction area. The neutron beams produced at the Target 4 complement those produced at the Lujan Center because they are of much higher energy and have shorter pulse widths. The neutron sources are driven by the 800-MeV proton beam of the LANSCE linear accelerator. With these facilities, LANSCE is able to deliver neutrons with energies ranging from a milli-electron volt to several hundreds of MeV, as well as proton beams with a wide range of energy, time and intensity characteristics. The facilities, instruments and research programs are described briefly.

43 PARTICLE ACCELERATORS↗

Negative hydrogen ion sources for particle accelerators: Sustainability issues and recent improvements in long-term operations

High brightness, negative hydrogen ion sources are used extensively in scientific facilities operating worldwide. Negative hydrogen beams have become the preferred means of filling circular accelerators and storage rings as well as enabling efficient extraction from cyclotrons. Several well-known facilities now have considerable experience with operating a variety of sources such as RF-, filament-, magnetron- and Penning-type H- ion sources. These facilities include the US Spallation Neutron Source (SNS), Japan Proton Accelerator Research Complex (J-PARC), Rutherford Appleton Laboratory (RAL-ISIS), Los Alamos Neutron Science Center (LANSCE), Fermi National Accelerator Laboratory (FNAL), Brookhaven National Laboratory (BNL), numerous installations of D-Pace (licenced by TRIUMF) ion sources used mainly on cyclotrons and, most recently, the CERN-LINAC-1 injector. This report first summarizes the current performance of these ion sources in routine, daily operations with attention toward source service-periods and availability metrics. Sustainability issues encountered at each facility are also reported and categorized to identify areas of common concern and key issues. Recent ion source improvements to address these issues are also discussed as well as plans for meeting future facility upgrade requirements.

Welton, Robert F.↗

Reconstruction of fast neutron direction in segmented organic detectors using deep learning

A method for reconstructing the direction of a fast neutron source using a segmented organic scintillator-based detector and deep learning model is proposed and analyzed. Here, the model is based on recurrent neural network, which can be trained by a sequence of data obtained from an event recorded in the detector and suitably pre-processed. The performance of deep learning-based model is compared with the conventional double-scatter detection algorithm in reconstructing the direction of a fast neutron source. With the deep learning model, the uncertainty in source direction of 0.301 rad is achieved with 100 neutron detection events in a segmented cubic organic scintillator detector with a side length of 46 mm. To reconstruct the source direction with the same angular resolution as the double-scatter algorithm, the deep learning method requires 75% fewer events. Application of this method could augment the operation of segmented detectors operated in the neutron scatter camera configuration for applications such as special nuclear material detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report from the Inaugural Meeting on the Opportunities at the SEEMS Facility

An Inaugural Meeting on the Opportunities at the SEEMS Facility was held at the Spallation Neutron Source (SNS) on June 11 - 12, 2019. It focused on the second of the user communities - industrial and academic researchers. Indeed, the SEEMS design concept started with a Spallation Neutron Source (SNS) study conducted for the Federal Aviation Administration (FAA) that examines test facility options for providing neutron radiation simulating that in the atmosphere originating from cosmic rays and solar particles. The study was stimulated by earlier work calling for neutron radiation facilities with increased capacity and capabilities to meet current and future needs. Regulators, aircraft producers and avionics equipment suppliers recognize the growing urgent need for SEE testing in prototypical radiation fields. Industry standards formalizing procedures to assure that critical systems are robust against SEE phenomena have been issued. Regulatory bodies including the Federal Aviation Administration (FAA) and the European Union Aviation Safety Agency (EASA) now requiring that updated standards are met for aircraft certification.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A novel approach to correct the coded aperture misalignment for fast neutron imaging

Aperture alignment is crucial for the diagnosis of neutron imaging because it has significant impact on the coding imaging and the understanding of the neutron source. In our previous studies on the neutron imaging system with coded aperture for large field of view, “residual watermark,” certain extra information that overlies reconstructed image and has nothing to do with the source is discovered if the peak normalization is employed in genetic algorithms (GA) to reconstruct the source image. Some studies on basic properties of residual watermark indicate that the residual watermark can characterize coded aperture and can thus be used to determine the location of coded aperture relative to the system axis. In this paper, we have further analyzed the essential conditions for the existence of residual watermark and the requirements of the reconstruction algorithm for the emergence of residual watermark. A gamma coded imaging experiment has been performed to verify the existence of residual watermark. Based on the residual watermark, a correction method for the aperture misalignment has been studied. A multiple linear regression model of the position of coded aperture axis, the position of residual watermark center, and the gray barycenter of neutron source with twenty training samples has been set up. Using the regression model and verification samples, we have found the position of the coded aperture axis relative to the system axis with an accuracy of approximately 20 μm. Conclusively, a novel approach has been established to correct the coded aperture misalignment for fast neutron coded imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Improved Nuclear Data for Nuclear Criticality and Safety

The Geel Electron Linear Accelerator (GELINA) was used to measure neutron total and capture cross sections of 182,183,184,186 W and 63,65 Cu in the energy range from 100 eV to {approx}200 keV using the time-of-flight method. GELINA is the only high-power white neutron source with excellent timing resolution and ideally suited for these experiments. Concerns about the use of existing cross-section data in nuclear criticality calculations using Monte Carlo codes and benchmarks were a prime motivator for the new cross-section measurements. To support the Nuclear Criticality Safety Program, neutron cross-section measurements were initiated using GELINA at the EC-JRC-IRMM. Concerns about data deficiencies in some existing cross-section evaluations from libraries such as ENDF/B, JEFF, or JENDL for nuclear criticality calculations were the prime motivator for new cross-section measurements. Over the past years many troubles with existing nuclear data have emerged, such as problems related to proper normalization, neutron sensitivity backgrounds, poorly characterized samples, and use of improper pulse-height weighting functions. These deficiencies may occur in the resolved- and unresolved-resonance region and may lead to erroneous nuclear criticality calculations. An example is the use of the evaluated neutron cross-section data for tungsten in nuclear criticality safety calculations, which exhibit discrepancies in benchmark calculations and show the need for reliable covariance data. We measured the neutron total and capture cross sections of 182,183,184,186 W and 63,65 Cu in the neutron energy range from 100 eV to several hundred keV. This will help to improve the representation of the cross sections since most of the available evaluated data rely only on old measurements. Usually, these measurements were done with poor experimental resolution or only over a very limited energy range, which is insufficient for the current application.

43 PARTICLE ACCELERATORS↗

Improved neutron-gamma discrimination for a {sup 6}Li-glass neutron detector using digital signal analysis methods

A {sup 6}Li-glass scintillator (GS20) based neutron Anger camera was developed for time-of-flight single-crystal diffraction instruments at Spallation Neutron Source. Traditional Pulse-Height Analysis (PHA) for Neutron-Gamma Discrimination (NGD) resulted in the neutron-gamma efficiency ratio (defined as NGD ratio) on the order of 10{sup 4}. The NGD ratios of Anger cameras need to be improved for broader applications including neutron reflectometers. For this purpose, six digital signal analysis methods of individual waveforms acquired from photomultiplier tubes were proposed using (i) charge integration, (ii) pulse-amplitude histograms, (iii) power spectrum analysis combined with the maximum pulse-amplitude, (iv) two event parameters (a{sub 1}, b{sub 0}) obtained from a Wiener filter, (v) an effective amplitude (m) obtained from an adaptive least-mean-square filter, and (vi) a cross-correlation coefficient between individual and reference waveforms. The NGD ratios are about 70 times those from the traditional PHA method. Our results indicate the NGD capabilities of neutron Anger cameras based on GS20 scintillators can be significantly improved with digital signal analysis methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution Neutron Cross-Section Measurements at the Oak Ridge Electron Linear Accelerator

Over the last three decades, the Oak Ridge Electron Linear Accelerator (ORELA) has produced many neutron-induced cross-section data. ORELA is the only high-power white neutron source with excellent time resolution still operating in the United States and is ideally suited for experiments to measure neutron fission, total, (n,), and capture cross sections in the energy range from 1 eV to as high as several MeV. Recent measurements have included neutron capture measurements on 39,41K, 35,37Cl, F, Mn, 58,60Ni, 53Cr, natural Cr, 48Ti, natural Ti, and 95Mo and total cross-section measurements on natural Cl, natural K, 95Mo, Mn, 53Cr, natural Cr, 48Ti, natural Ti, and 64Zn(n,). Many of these measurements were carried out to support the U.S. Nuclear Criticality Safety Program. Concerns have been raised about many of the older nuclear data evaluations important for criticality safety. For example, the time-of-flight resolution and accuracy of some of the existing data are too poor for new evaluations and thus applications. Several of these data are also important input parameters for the ongoing nuclear astrophysics program, which investigates the s-process nucleosynthesis in asymptotic giant branch stars. Here the Maxwellian-averaged neutron capture cross sections at kT = 8 and 30 keV are of importance. This paper provides an overview of the high-resolution cross-section measurement facility ORELA and describes the current measurement activities.

43 PARTICLE ACCELERATORS↗