Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL MODES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Laser dissection sampling modes for direct mass spectral analysis [using a hybrid optical microscopy/laser ablation liquid vortex capture/electrospray ionization system

Here, laser microdissection coupled directly with mass spectrometry provides the capability of on-line analysis of substrates with high spatial resolution, high collection efficiency, and freedom on shape and size of the sampling area. Establishing the merits and capabilities of the different sampling modes that the system provides is necessary in order to select the best sampling mode for characterizing analytically challenging samples. The capabilities of laser ablation spot sampling, laser ablation raster sampling, and laser 'cut and drop' sampling modes of a hybrid optical microscopy/laser ablation liquid vortex capture electrospray ionization mass spectrometry system were compared for the analysis of single cells and tissue. Single Chlamydomonas reinhardtii cells were monitored for their monogalactosyldiacylglycerol (MGDG) and diacylglyceryltrimethylhomo-Ser (DGTS) lipid content using the laser spot sampling mode, which was capable of ablating individual cells (4-15 m) even when agglomerated together. Turbid Allium Cepa cells (150 m) having unique shapes difficult to precisely measure using the other sampling modes could be ablated in their entirety using laser raster sampling. Intact microdissections of specific regions of a cocaine-dosed mouse brain tissue were compared using laser 'cut and drop' sampling. Since in laser 'cut and drop' sampling whole and otherwise unmodified sections are captured into the probe, 100% collection efficiencies were achieved. Laser ablation spot sampling has the highest spatial resolution of any sampling mode, while laser ablation raster sampling has the highest sampling area adaptability of the sampling modes. In conclusion, laser ablation spot sampling has the highest spatial resolution of any sampling mode, useful in this case for the analysis of single cells. Laser ablation raster sampling was best for sampling regions with unique shapes that are difficult to measure using other sampling modes. Laser 'cut and drop' sampling can be used for cases where the highest sensitivity is needed, for example, monitoring drugs present in trace amounts in tissue.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visible radiation-induced connection of single-mode IR fibres in a photopolymerising composition

The properties of the optical connection of single-mode fibres by laser beams counterpropagating from the ends of these fibres are considered numerically and experimentally. It is shown that effective connection of single-mode fibres at the wavelength of 1.55 {mu}m is possible during self-channelling and interaction of optical beams at 0.63 {mu}m in a photopolymerising medium. In this case, the long exposure can lead to a decrease in the transmission coefficient, especially when the ends of the fibres being connected are positioned off-axially. It is obtained experimentally that for the 1-2-mm-long polymer connector and the {approx}15-{mu}m radial displacement, the efficiency of the optical connection of the SMF-28 and CS-980 single-mode fibres in a OCM-2 photopolymerising composition can achieve 80%-90% and 50%-60%, respectively. (optical fibres)

36 MATERIALS SCIENCE↗

Versatile cold atom target apparatus

We report on a compact and transportable apparatus that consists of a cold atomic target at the center of a high resolution recoil ion momentum spectrometer. Cold rubidium atoms serve as a target which can be operated in three different modes: in continuous mode, consisting of a cold atom beam generated by a two-dimensional magneto-optical trap, in normal mode in which the atoms from the beam are trapped in a three-dimensional magneto-optical trap (3D MOT), and in high density mode in which the 3D MOT is operated in dark spontaneous optical trap configuration. The targets are characterized using photoionization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exciton dressing by extreme nonlinear magnons in a layered semiconductor

Collective excitations presenting nonlinear dynamics are fundamental phenomena with broad applications. A prime example is nonlinear optics, where diverse frequency mixing processes are central to communication, sensing, wavelength conversion, and attosecond physics. Leveraging recent progress in van der Waals magnetic semiconductors, we demonstrate nonlinear opto-magnonic coupling by presenting exciton states dressed by up to 20 harmonics of magnons, resulting from their nonlinearities, in the layered antiferromagnetic semiconductor CrSBr. We also create tunable optical side bands from sum- and difference-frequency generation between two optically bright magnon modes under symmetry breaking magnetic fields. Moreover, the observed difference-frequency generation mode can be continuously tuned into resonance with one of the fundamental magnons, resulting in parametric amplification of magnons. These findings realize the modulation of the optical frequency exciton with the extreme nonlinearity of magnons at microwave frequencies, which could find applications in magnonics and hybrid quantum systems, and provide new avenues for implementing opto-magnonic devices.

Diederich, Geoffrey M.↗

Quasioptical modeling of wave beams with and without mode conversion. I. Basic theory

This work opens a series of papers where we develop a general quasi-optical theory for mode-converting electromagnetic beams in plasma and implement it in a numerical algorithm. Here, the basic theory is introduced. We consider a general quasimonochromatic multicomponent wave in a weakly inhomogeneous linear medium with no sources. For any given dispersion operator that governs the wave field, we explicitly calculate the approximate operator that governs the wave envelope ψ to the second order in the geometrical-optics parameter. Then, we further simplify this envelope operator by assuming that the gradient of ψ transverse to the local group velocity is much larger than the corresponding parallel gradient. This leads to a parabolic differential equation for ψ (“quasioptical equation”) on the basis of the geometrical-optics polarization vectors. Scalar and mode-converting vector beams are described on the same footing. Here, we also explain how to apply this model to electromagnetic waves in general. In the next papers of this series, we report successful quasioptical modeling of radio frequency wave beams in magnetized plasma based on this theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controlling slow and fast light and dynamic pulse-splitting with tunable optical gain in a whispering-gallery-mode microcavity

We report controllable manipulation of slow and fast light in a whispering-gallery-mode microtoroid resonator fabricated from Erbium (Er{sup 3+}) doped silica. We observe continuous transition of the coupling between the fiber-taper waveguide and the microresonator from undercoupling to critical coupling and then to overcoupling regimes by increasing the pump power even though the spatial distance between the resonator and the waveguide was kept fixed. This, in turn, enables switching from fast to slow light and vice versa just by increasing the optical gain. An enhancement of delay of two-fold over the passive silica resonator (no optical gain) was observed in the slow light regime. Moreover, we show dynamic pulse splitting and its control in slow/fast light systems using optical gain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Catastrophic optical degradation of the output facet of high-power single-transverse-mode diode lasers. 2. Calculation of the spatial temperature distribution and threshold of the catastrophic optical degradation

The temperature distribution and the power threshold during the catastrophic optical degradation are calculated within the framework of the developed model of the COD of the output facet in high-power single-transverse-mode diode lasers. Comparison of the calculation results and the experiment show the model adequacy. The contribution of different physical mechanisms into the heating of the laser output facet is analysed. It is shown that the model under study can help to develop the method for predicting the laser lifetime by the accelerated ageing tests. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency stabilization via the mixed mode in three mode HeNe lasers

This paper describes a three mode HeNe laser frequency stabilization technique using the mixed mode frequency to obtain a fractional frequency stability of 2 x 10{sup -11}. The mixed mode frequency occurs due to optical nonlinear interactions with the adjacent modes at each of the three modes. In precision displacement interferometry systems, the laser source frequency must be stabilized to provide an accurate conversion ratio between phase change and displacement. In systems, such as lithography applications, which require high speed, high accuracy and low data age uncertainty, it is also desirable to avoid periodic nonlinearities, which reduces computation time and errors. One method to reduce periodic nonlinearity is to spatially separate the measurement and reference beams to prevent optical mixing, which has been shown for several systems. Using spatially separated beams and the proper optical configuration, the interferometer can be fiber fed, which can increase the interferometer's stability by reducing the number of beam steering optical elements. Additionally, as the number of measurement axes increases, a higher optical power from the laser source is necessary.

42 ENGINEERING↗

Single-nanoparticle detection with slot-mode photonic crystal cavities

Optical cavities that are capable for detecting single nanoparticles could lead to great progress in early stage disease diagnostics and the study of biological interactions on the single-molecule level. In particular, photonic crystal (PhC) cavities are excellent platforms for label-free single-nanoparticle detection, owing to their high quality (Q) factors and wavelength-scale modal volumes. Here, we demonstrate the design and fabrication of a high-Q (>10{sup 4}) slot-mode PhC nanobeam cavity, which is able to strongly confine light in the slotted regions. The enhanced light-matter interaction results in an order of magnitude improvement in both refractive index sensitivity (439 nm/RIU) and single-nanoparticle sensitivity compared with conventional dielectric-mode PhC cavities. Detection of single polystyrene nanoparticles with radii of 20 nm and 30 nm is demonstrated in aqueous environments (D{sub 2}O), without additional laser and temperature stabilization techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Whispering gallery modes in a spherical microcavity with a photoluminescent shell

Whispering-gallery mode spectra in optical microcavities based on spherical silica particles coated with a thin photoluminescent shell of hydrogenated amorphous silicon carbide are studied. The spectral positions of the whispering-gallery modes for spherical microcavities with a shell are calculated. The dependence of the spectral distance between the TE and TM modes on the shell thickness is examined.

36 MATERIALS SCIENCE↗

Polarization ray tracing in anisotropic optically active media

Procedures for performing polarization ray tracing through birefringent media are presented in a form compatible with the standard methods of geometric ray tracing. The birefringent materials treated include the following: anisotropic optically active materials such as quartz, non-optically active uniaxial materials such as calcite, and isotropic optically active materials such as mercury sulfide or organic liquids. Refraction and reflection algorithms are presented which compute both ray directions and wave directions. Methods for computing polarization modes, refractive indices, optical path lengths, and Fresnel transmission and reflection coefficients are also specified.

Mcclain, Stephen C.↗

Measurement of Spatial Filtering Capabilities of Single Mode Infrared Fibers

Spatial filtering is necessary to achieve deep nulls in optical interferometer and single mode infrared fibers can serve as spatial filters. The filtering function is based on the ability of these devices to perform the mode-cleaning function: only the component of the input field that is coupled to the single bound (fundamental) mode of the device propagates to the output without substantial loss. In practical fiber devices, there are leakage channels that cause light not coupled into the fundamental mode to propagate to the output. These include propagation through the fiber cladding and by means of a leaky mode. We propose a technique for measuring the magnitude of this leakage and apply it to infrared fibers made at the Naval Research Laboratory and at Tel Aviv University.

infrared↗

Use of rate equations to describe laser excitation in flames

The region of validity of conventional rate equation formulations used to describe the excitation of flame gases for spectroscopic diagnostic purposes is examined by direct comparison with the density matrix formulation. The density matrix equations are formulated for an ensemble of atoms or molecules in the gas state. These equations are reduced to the steady-state limit for a two-level system under the effect of single-mode and multimode optical fields. The steady-state equations are shown to be valid only when the laser pulse rises slowly with respect to the collisional dephasing rate for single-mode excitation, and for certain special cases under multimode excitation.

Daily, J. W.↗

Real-Time Optical Receiver Decoder Architecture Changes for High-Speed Modes

The National Aeronautics and Space Administration (NASA) at Glenn Research Center (GRC) has developed an optical communications transmitter and receiver using Commercial-off-the-shelf (COTS) components. The goal of this project is to become fully compliant with Consultative Committee for Space Data Systems (CCSDS) High Photon Efficiency (HPE) Optical Communications Coding and Synchronization standard. The receive modem’s decoder has been modified using shift registers to enable the decoding of higher data rate pulse-position modulation (PPM) 4 and PPM-8 signals. PPM-4 and PPM-8 is then verified by comparing the codeword error rate (CWER) of a hardware implementation to a software simulation. The changes show the capability to decode PPM-4 and PPM-8 for a single decoder. This memorandum details the changes made, the performance achieved with the changes, and necessary future work.

PPM↗

High-power diode lasers for optical communications applications

High-power, single-mode, double-heterojunction AlGaAs diode lasers are being developed to meet source requirements for both fiber optic local area network and free space communications systems. An individual device, based on the channeled-substrate-planar (CSP) structure, has yielded single spatial and longitudinal mode outputs of up to 90 mW CW, and has maintained a single spatial mode to 150 mW CW. Phase-locked arrays of closely spaced index-guided lasers have been designed and fabricated with the aim of multiplying the outputs of the individual devices to even higher power levels in a stable, single-lobe, anastigmatic beam. The optical modes of the lasers in such arrays can couple together in such a way that they appear to be emanating from a single source, and can therefore be efficiently coupled into optical communications systems. This paper will review the state of high-power laser technology and discuss the communication system implications of these devices.

Carlin, D. B.↗

Self-consistent interaction of linear gravitational and electromagnetic waves in non-magnetized plasma

Here, this paper explores the hybridization of linear metric perturbations with linear electromagnetic (EM) perturbations in non-magnetized plasma for a general background metric. The local wave properties are derived from first principles for inhomogeneous plasma, without assuming any symmetries of the background metric. First, we derive the effective (“oscillation-center”) Hamiltonian that governs the average dynamics of plasma particles in a prescribed quasimonochromatic wave that involves metric perturbations and EM fields simultaneously. Then, using this Hamiltonian, we derive the backreaction of plasma particles on the wave itself and obtain gauge-invariant equations that describe the resulting self-consistent gravito-electromagnetic (GEM) waves in a plasma. The transverse tensor modes of gravitational waves are found to have no interaction with the plasma and the EM modes in the geometrical-optics limit. However, for $longitudinal$ GEM modes with large values of the refraction index, the interplay between gravitational and EM interactions in plasma can have a strong effect. In particular, the dispersion relation of the Jeans mode is significantly affected by electrostatic interactions. As a spin-off, our calculation also provides an alternative resolution of the so-called Jeans swindle.

79 ASTRONOMY AND ASTROPHYSICS↗

Picosecond streak camera display of an intermodal coupling matrix at a multimode fiber splice

A technique is developed that permits direct visualization of the coupling matrix for all guided modes of a moderately multimode fiber optic at a splice or mode coupler. The matrix is formed by an array of spots at the output of a picosecond streak camera. The technique also permits unambiguous determination of the phase velocity and group velocity of the modes.

Louradour, F.↗

Variations in dose distribution and optical properties of Gafchromic{sup TM} EBT2 film according to scanning mode

Purpose: The authors aim was to investigate the effects of using transmission and reflection scanning modes, the film orientation during scanning, and ambient room light on a dosimetry system based on the Gafchromic{sup TM} EBT2 film model. Methods: For calibration, the films were cut to 3 x 3 cm{sup 2} and irradiated from 20 to 700 cGy at the depth of maximum dose using 6 and 10 MV photon beams in a 10 x 10 cm{sup 2} field size. Absolute dose calibration of the linear accelerator was done according to the TRS398 protocol. An FG65-G ionization chamber was used to monitor the dose while irradiating the films in solid water. The film pieces were scanned with an EPSON Expression 1680 Pro flatbed scanner in transmission and reflection modes. Authors investigated the effect of orientation on films and examined the optical properties of EBT2 film using an ellipsometer and an ultraviolet (UV)/visible spectrometer to explain the dosimetric dependence of the film on orientation during the scanning process. To investigate the effect of ambient room light, films were preirradiated in 6 and 10 MV photon beams with intensity-modulated radiotherapy (IMRT) quality assurance (QA) plans, and then exposed to room light, either directly for 2 days in a workroom or for 2 months in a film box. Gamma index pass criteria of (3%, 3 mm) were used. Results: The dose response curves based on net optical density (NOD) indicated that the reflection scanning mode can provide a better dose sensitivity than the transmission scanning mode, whereas the standard deviation of the dose is greater in reflection mode than in transmission mode. When the film was rotated 90 deg. from the portrait orientation, the average dose of the EBT2 film decreased by 11.5-19.6% in transmission mode and by 1.5-2.3% in reflection mode. Using an ellipsometer, variation of the refractive index of EBT2 film--the birefringence property--was found to be the largest between 45 deg. (1.72 and 1.71) and 135 deg. (1.8 and 1.77) for 300 and 800 cGy. Absorption spectra of EBT2 films measured with spectrometer were the function of film orientation. The readings in reflection scanning mode were more stable against room light than those in transmission scanning mode, although dose readings increased in both modes after the films were exposed to room light. Conclusions: The transmission scanning mode exhibited a strong dependence on film orientation during scanning and a change in optical density resulting from room light exposure, so a constant scanning orientation and minimal exposure to light can reduce uncertainty in the measured dose (23 {+-} 3%). The angular dependence was analyzed using Jones matrices and optical properties of EBT2 film were obtained using an ellipsometer and an UV/visible spectrometer. The reflection scanning mode has relatively good stability with respect to room light and film orientation on a scanner, although the large standard deviation of dose is a disadvantage in measurements of absolute dose. Reflection scanning mode can offer a potential advantage for film dosimetry in radiotherapy, although transmission scanning mode is still recommended for dosimetry as it provides better uncertainty results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗