Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Retrospective comparison of outcomes and associated complications between large bore radiologically inserted gastrostomy tube types

Purpose: Multiple approaches to radiologically inserted gastrostomy (RIG) exist. The goal of this study was to compare 30-day outcomes and associated complications between large bore balloon-retained (BR), loop-retained (LR), and pull-type (PT) RIG devices. Methods: Data on 1477 patients who underwent RIG between January 1, 2005 and December 31, 2016 were collected retrospectively using a dedicated interventional radiology database and electronic medical record. Statistical analysis was performed to compare complication rates between BR, LR, and PT devices. Results: Ninety-eight percent (1477/1507) of the procedures were successfully performed. A total of 752 BR, 323 LR, and 402 PT gastrostomy tubes were placed. The overall complication rate for BR catheters was 5.7% (25 major [3.3%] and 18 minor [2.4%]). The overall complication rate for PT catheters was 3.7% (8 major [2.0%] and 7 minor [1.7%]). The overall complication rate for LR catheters was 1.6% (4 major [1.4%] and 1 minor [0.8%]). Compared to BR catheters, LR catheters had significantly fewer total complications (P = 0.01) but not minor complications (P = 0.052). There were no significant differences in the number of complications between LR and PT catheters or between BR and PT catheters. Conclusions: Use of BR, LR, and PT devices for RIG is safe with a low incidence of complications. Compared to BR catheters, primary insertion of a LR gastrostomy was associated with significantly fewer overall complications within the first 30 days. Therefore, for initial tube placement, large bore LR catheters may be preferred over BR devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Length-scale-dependent nanoindentation creep behaviour of Ti/Al multilayers by magnetron sputtering

This study presented length-scale-dependent room temperature creep behaviour of Ti/Al multilayers by nanoindentation. Ti/Al multilayers with individual layer thickness ranging from 10 nm to 250 nm were prepared by a direct current magnetron sputtering method. Microstructural analysis showed that the prepared Ti/Al multilayers were polycrystalline, with strong Ti (0002) and Al (111) texture. Nanoindentation creep tests were performed to examine the time-dependent creep deformation, stress exponent, creep strain rate sensitivity and contact creep compliance of the multilayers at room temperature. It was found that both the maximum creep deformation and the creep strain rate sensitivity increase with an increase in the individual layer thickness, indicating a length-scale-dependent creep behaviour of the Ti/Al multilayers. The values of stress exponent were found to lay in the range of 15.74–61.46, implying that the creep behaviour of the multilayers was controlled by the dislocation creep mechanism. Finally, the contact creep compliances of the Ti/Al multilayers were well modelled by a two-element Kelvin-Voigt model. From this, it was determined that the creep numbers and retardation times increased with increased individual layer thickness.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Classifying handedness in chiral nanomaterials using label error robust deep learning

Abstract High-throughput scanning electron microscopy (SEM) coupled with classification using neural networks is an ideal method to determine the morphological handedness of large populations of chiral nanoparticles. Automated labeling removes the time-consuming manual labeling of training data, but introduces label error, and subsequently classification error in the trained neural network. Here, we evaluate methods to minimize classification error when training from automated labels of SEM datasets of chiral Tellurium nanoparticles. Using the mirror relationship between images of opposite handed particles, we artificially create populations of varying label error. We analyze the impact of label error rate and training method on the classification error of neural networks on an ideal dataset and on a practical dataset. Of the three training methods considered, we find that a pretraining approach yields the most accurate results across label error rates on ideal datasets, where size and other morphological variables are held constant, but that a co-teaching approach performs the best in practical application.

36 MATERIALS SCIENCE↗

Resilience of the surface code to error bursts

Quantum error correction works effectively only if the error rate of gate operations is sufficiently low. However, some rare physical mechanisms can cause a temporary increase in the error rate that affects many qubits; examples include ionizing radiation in superconducting hardware and large deviations in the global control of atomic systems. We refer to such rare transient spikes in the gate error rate as error bursts. In this work, we investigate the resilience of the rotated surface code to generic error bursts. We assume that, after appropriate mitigation strategies, the spike in the error rate lasts for only a single syndrome-extraction cycle; we also assume that the enhanced error rate is uniform across the code block. Under these assumptions, and for a circuit-level depolarizing noise model, we perform Monte Carlo simulations to determine the regime in burst error rate and background error rate for which the memory time becomes arbitrarily long as the code block size grows. Our results indicate that suitable hardware mitigation methods combined with standard decoding methods may suffice to protect against transient error bursts in the rotated surface code.

Quantum error correction↗

Is Routine Splenectomy Justified for All Left-Sided Pancreatic Cancers? Histological Reappraisal of Splenic Hilar Lymphadenectomy

Background: Although splenectomy is recommended during resection for left-sided resectable pancreatic ductal adenocarcinoma (PDAC) to perform lymphadenectomy of station 10 (splenic hilum), no level I evidence justifies this procedure. This study aims to evaluate the rate of lymph node (LN) and contiguous involvement of the splenic hilum in resectable distal PDAC. Methods: We retrospectively reviewed all patients who underwent splenopancreatectomy for PDAC in the past 10 years. Station 10 LN were routinely isolated, and all corresponding microscopic slides were reinterpreted by a pathologist. The computed tomography (CT) results of patients with tumoral involvement of the spleen or splenic hilum by contiguity (TISOSH) and ≤ 10 mm between the tumor and spleen on pathology were blindly reviewed by two radiologists to evaluate CT for diagnosis of TISOSH. Results: We included 110 consecutive patients, including 104 with analyzable station 10 LN. The tumor was N+ in 58 (53%) patients. The median number of LN identified at station 10 was 2.0 ± 3.0. No station 10 LNs were detected in 42 (40%) patients. No patients had tumor-positive LN at station 10. TISOSH was found in nine (8%) patients, and was significantly associated with tail location (p = 0.001), tumor size (p = 0.005), and multivisceral involvement (p = 0.015). For diagnosis of TISOSH, the sensitivity and specificity of CT were respectively 89% and 95% for radiologist 1 and 89% and 100% for radiologist 2. Conclusions: Splenic preservation during resection of distal PDAC may be an option in selected patients with body tumors and no suspected splenic or splenic hilum involvement on preoperative CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overuse of Preoperative Staging of Patients Undergoing Neoadjuvant Chemotherapy for Breast Cancer

Background: Guidelines of the American Society of Clinical Oncology (ASCO), the National Comprehensive Cancer Network (NCCN), and the European Society for Medical Oncology (ESMO) discourage the use of imaging to stage newly diagnosed early breast cancer (stages 1 and 2). This study aimed to evaluate preoperative staging imaging rates among patients with stage 1 or 2 breast cancer treated with neoadjuvant chemotherapy (NAC). Methods: From a prospectively maintained database, 303 patients with stage 1 or 2 breast cancer who had NAC from 2008 to 2016 were identified. The main outcome measures were the rate and outcomes of staging imaging performed. Results: The mean age of the 303 patients with stage 1 or 2 breast cancer was 51 years (range, 26–87 years). Of these 303 patients, 278 (92.4%) had invasive ductal cancer. 90 (30.2%) had estrogen receptor (ER)-positive disease, 79 (26.5%) had triple-negative disease, and 127 (42.6%) had human epidermal growth factor receptor 2 (HER2)-positive disease. Staging positron emission tomography (PET) or computed tomography (CT) scan was performed for 258 patients (85.2%), brain imaging for 94 patients (31%), bone scans for 117 patients (38.6%), and all three for 48 patients (15.8%). As a result, 15 patients (4.9%) with a positive PET/CT scan were upstaged to stage 4 breast cancer. No difference was observed among the ER-positive (p = 1.000), HER2-positive (p = 0.259), or triple-negative (p = 0.369) receptor profiles of the patients upstaged to stage 4 disease. One patient (1.1%) had positive brain imaging. Five patients (4.3%) had a positive bone scan, and three of these patients (60%) had bone metastasis also shown on the PET/CT scan. Conclusion: Despite guideline recommendations, a high rate of preoperative staging imaging is completed for patients with clinical stage 1 or 2 breast cancer who receive NAC, with few positive results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Digital-computer normal shock position and restart control of a Mach 2.5 axisymmetric mixed-compression inlet

Digital computer control of a mixed-compression inlet is discussed. The inlet was terminated with a choked orifice at the compressor face station to dynamically simulate a turbojet engine. Inlet diffuser exit airflow disturbances were used. A digital version of a previously tested analog control system was used for both normal shock and restart control. Digital computer algorithms were derived using z-transform and finite difference methods. Using a sample rate of 1000 samples per second, the digital normal shock and restart controls essentially duplicated the inlet analog computer control results. At a sample rate of 100 samples per second, the control system performed adequately but was less stable.

Neiner, G. H.↗

Control systems synthesis for a large flexible space antenna

The problem of control systems synthesis is considered for controlling the rigid-body attitude and elastic motion of a large deployable space-based antenna. Two methods for control systems synthesis are considered. The first method utilizes the stability and robustness properties of the controller consisting of torque actuators and collocated attitude and rate sensors. The second method is based on the linear-quadratic-Gaussian (LQG) control theory. A combination of the two methods, which results in a two-level hierarchical control system, is also briefly discussed. The performance of the controllers is analyzed by computing the variances of pointing errors, feed misalignment errors and surface contour errors in the presence of sensor and actuator noise.

Joshi, S. M.↗

Structural Tailoring of SSME Blades (vanes)

The engine blade design optimization program STAEBL (Structural Tailoring of Engine Blades) is available at the NASA Lewis computer facility. The analysis capabilities of this program were extended to typical loading conditions for SSME turbopump blades including thermal and pressure loading. Input files for representative SSME blade designs were developed and sample optimization studies for these blades completed. The structural tailoring program combines a general optimization package and a finite element blade analysis package. The analysis package's capabilities include natural frequency, maximum stress, and forced response computation, and fatigue life and flutter analysis. Optimization is performed using the feasible directions method. The current design is modified by perturbing the design variables so that the design constraints are satisfied while the objective function, such as blade weight, is reduced at the maximum rate. The program's geometric design variables include blade thickness distribution, thickness to chord ratios, and root chord.

Rubinstein, R.↗

Development of a coded 16-ary CPFSK coherent demodulator

Theory and hardware are described for a proof-of-concept 16-ary continuous phase frequency shift keying (16-CPFSK) digital modem. The 16 frequencies are spaced every 1/16th baud rate for 2 bits/sec/Hz operation. Overall rate 3/4 convolutional coding is incorporated. The demodulator differs significantly from typical quadrature phase detector approaches in that phase is coherently measured by processing the baseband output of a frequency discriminator. Baud rate phase samples from the baseband processor are decoded to yield the original data stream. The method of encoding onto the 16-ary phase nodes, together with convolutional coding gain, results in near quad PSK (QPSK) performance. The modulated signal is of constant envelope; thus the power amplifier can be saturated for peak performance. The spectrum is inherently bandlimited and requires no RF filter.

Clarke, Ken↗

Atomic oxygen undercutting of defects on SiO2 protected polyimide solar array blankets

Low Earth Orbital (LEO) atomic oxygen can oxidize SiO2-protected polyimide kapton solar array blanket material which is not totally protected as a result of pinholes or scratches in the SiO2 coatings. The probability of atomic oxygen reaction upon initial impact is low, thus inviting oxidation by secondary impacts. The secondary impacts can produce atomic oxygen undercutting which may lead to coating mechanical failure and ever increasing mass loss rates of kapton. Comparison of undercutting effects in isotropic plasma asher and directed beam tests are reported. These experimental results are compared with computational undercutting profiles based on Monte Carlo methods and their implication on LEO performance of protected polymers.

Banks, Bruce A.↗

The temperature dependent variation of bulk and surface composition of In(x)Ga(1-x)As on GaAs grown by chemical beam epitaxy studied by RHEED, X-ray diffraction and XPS

The paper investigates the bulk as well as near-surface composition of In(x)Ga(1-x)As epilayers on GaAs grown by chemical beam epitaxy (CBE) as a function of triethylindium flow rate and substrate temperature by reflection high energy electron diffraction (RHEED), X-ray diffraction, and XPS. To clarify whether the bulk stoichiometry of CBE-grown ternaries can be extracted from the growth rate change as determined by the change in the period of RHEED oscillations from binary to ternary compound growth, a systematic study of growth rate change as a function of ternary bulk composition determined by X-ray diffraction was performed at various temperatures. It is shown that for low growth temperatures there is a linear relationship between the two methods of determination, whereas no correlation is found for higher growth temperatures, in contrast to the MBE case where the two methods of determination yield identical results. In the near surface region the epilayer composition is determined in situ by XPS.

Hansen, H. S.↗

Effects of through-the-thickness stitching on impact and interlaminar fracture properties of textile graphite/epoxy laminates

This study investigated the effects of through-the-thickness stitching on impact damage resistance, impact damage tolerance, and mode I and mode II fracture toughness of textile graphite/epoxy laminates. Uniweave resin-transfer-molded 48 ply graphite/epoxy (AS4/3501-6) laminates were stitched with Kevlar and glass yarns of different linear densities and stitch spacings. Delaminations were implanted during processing to simulate impact damage. Sublaminate buckling tests were performed to determine the effects of stitching on the compressive strength. The results showed outstanding improvements of up to 400 percent in the compression strength over the unstitched laminates. In impact and static indentation tests the onset of damage occurred at the same level, but the extent of damage was less in stitched laminates. Mode I fracture toughness of 24 ply Uniweave unidirectional (AS4/3501-6) stitched laminates was measured by conducting double-cantilever-beam tests. The critical strain energy release rate (G(sub Ic)) was found to be up to 30 times higher than the unstitched laminates. Mode II fracture toughness of the Uniweave laminates was measured by performing end-notched-flexure tests. Two new methods to compute the apparent G(sub IIc) are presented. The apparent G(sub IIc) was found to be at least 5-15 times higher for the stitched laminates.

Sharma, Suresh K.↗

A Parametric Study of a Plug Nozzle, Using the Liquid Propellant Program (LPP) Code

The Liquid Propellant Program (LPP) computer code is a super-set of the industry standard Two Dimensional Kinetics (TDK) computer code. The TDK code uses a two dimensional method of characteristics solution with fully coupled finite rate kinetics for axially symmetric nozzles. The chemical reactions are modeled with a generalized reaction package that include three dimensional body efficiencies and four reaction rate forms. The code performs optional solutions for frozen or equilibrium flow. TDK evaluates discrete shocks, both attached or induced. The Transonic module models variable mixture ratio profiles from the combustion chamber injector. The Mass Addition Boundary Layer module (MABL) calculates the boundary parameters with the same chemistry options, and includes transpiration or tangential slot injection of gas at the wall. The LPP upgrades include: planar nozzle, scarfed nozzles, plug nozzles, and scramjet nozzle configurations. The code evaluates both upper and lower wall flow simulation, and includes the interaction with the external flow. The MABL module evaluates equilibrium radiation heat transfer for both upper and lower walls. In addition, LPP code models combustion effects due to injector inefficiencies with the Spray Combustion Analysis Program (SCAP) module. The LPP package provides extensive post plotting capabilities for flow visualization. The LPP is sufficiently fast and robust to provide performance predictions for extensive parametric studies and sufficiently accurate to provide flow field and performance solutions for detailed studies.

Dunn, Stuart S.↗

Protein Crystal Growth With the Aid of Microfluidics

Protein crystallography is one of three well-known methods to obtain the structure of proteins. A major rate limiting step in protein crystallography is protein crystal nucleation and growth, which is still largely a process conducted by trial-and-error methods. Many attempts have been made to improve protein crystal growth by performing growth in microgravity. Although the use of microgravity appears to improve crystal quality in some attempts, this method has been inefficient because several reasons: we lack a fundamental understanding of macromolecular crystal growth in general and of the influence of microgravity in particular, we have to start with crystal growth conditions in microgravity based on conditions on the ground and finally the hardware does not allow for experimental iteration without reloading samples on the ground. To partially accommodate the disadvantages of the current hardware, we have used microfluidic technology (Lab-on-a-Chip devices) to design the concept of a more efficient crystallization device, suitable for use on the International Space Station and in high-throughput applications on the ground. The concept and properties of microfluidics, the application design process, and the advances in protein crystal growth hardware will be discussed in this presentation. Some examples of proteins crystallized in the new hardware will be discussed, including the differences between conventional crystallization versus crystallization in microfluidics.

vanderWoerd, Mark↗

DSMC Simulations of Hypersonic Flows and Comparison With Experiments

This paper presents computational results obtained with the direct simulation Monte Carlo (DSMC) method for several biconic test cases in which shock interactions and flow separation-reattachment are key features of the flow. Recent ground-based experiments have been performed for several biconic configurations, and surface heating rate and pressure measurements have been proposed for code validation studies. The present focus is to expand on the current validating activities for a relatively new DSMC code called DS2V that Bird (second author) has developed. Comparisons with experiments and other computations help clarify the agreement currently being achieved between computations and experiments and to identify the range of measurement variability of the proposed validation data when benchmarked with respect to the current computations. For the test cases with significant vibrational nonequilibrium, the effect of the vibrational energy surface accommodation on heating and other quantities is demonstrated.

Moss, James N.↗

MIT Participation in the Data Analysis of the XRS and XIS Instruments on the Astro-E2 Mission

Since the inception of this grant six weeks ago, we have completed the initial activation of the Suzaku X-ray Imaging Spectrometer (XIS) (on 13 August) and we have supported initial calibration observations. The instrument is performing very well in all respects. We have characterized the spectral resolution and effective area of each XIS sensor. We are especially excited about the scientific opportunities provided by the XIS'S back- illuminated sensor, which exhibits spectral resolution in the sub-keV band unmatched by any X-ray CCD currently in orbit. As specified in our proposal, we have established a web site (http://space.mit.edu/XIS) on which we maintain an up-to-date summary of instrument performance characteristics. Gain, spectral resolution and system noise, as well as residual background rates, are currently available on this site. Although the particle background level is low compared with Chandra and XMM, we are currently evaluating methods to reduce it still further. Techniques under study include use of 5x5 mode information and alternative grade selection methods. Although the primary responsibility for development of instrument response functions rests with our Japanese colleagues, we are incorporating our latest measurements of spectral resolution into some temporary response functions which we hope to make available to the Suzaku General Observer Facility and the Science Working Group(SWG). We are also preparing proposals for use of SWG observing time.

Bautz, Mark↗