Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Nonlinear waves in an array of zigzag waveguides with alternating positive and negative refractive indices

Interaction of coupled waves propagating in a system of waveguides with alternating positive and negative refractive indices is studied theoretically. The zigzag configuration of the waveguides in the array allows communication not only between the nearest neighbours, but also with the waveguides beyond them. It is shown that the spectrum of linear waves in such a waveguide system has a bandgap. Partial solutions are found to the system of coupled waves corresponding to a stationary electromagnetic field pulse that propagates along the array of tunnel-coupled waveguides as a whole. Investigation of the interaction of nonlinear solitary waves has demonstrated numerically the stability of their relatively weak disturbances and collisions with each other. (nanogradient dielectric coatings and metamaterials)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mu2e Solenoid Field Mapping System Design

The Mu2e experiment at Fermilab plans to search for charged-lepton flavor violation by looking for neutrino-less muon to electron conversion in the field of the nucleus. A complex solenoid system and precise knowledge of its magnetic field play a major role in the experimental approach Mu2e has chosen. It is essential to map the solenoid field up to 10 -4 accuracy. This article describes the design of the Field Mapping System Mu2e will use to measure the magnetic field. Two different mechanical mapper systems, a survey based position determination of the in-house calibrated 3D Hall probes, a motion control system, and a data acquisition and readout system are presented.

43 PARTICLE ACCELERATORS↗

Active optics null test system based on a liquid crystal programmable spatial light modulator

We present an active null test system adapted to test lenses and wavefronts with complex shapes and strong local deformations. This system provides greater flexibility than conventional static null tests that match only a precisely positioned, individual wavefront. The system is based on a cylindrical Shack-Hartmann wavefront sensor, a commercial liquid crystal programmable phase modulator (PPM), which acts as the active null corrector, enabling the compensation of large strokes with high fidelity in a single iteration, and a spatial filter to remove unmodulated light when steep phase changes are compensated. We have evaluated the PPM's phase response at 635 nm and checked its performance by measuring its capability to generate different amounts of defocus aberration, finding root mean squared errors below {lambda}/18 for spherical wavefronts with peak-to-valley heights of up to 78.7{lambda}, which stands as the limit from which diffractive artifacts created by the PPM have been found to be critical under no spatial filtering. Results of a null test for a complex lens (an ophthalmic customized progressive addition lens) are presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NRC technical basis for evaluation of its position on protection against common cause failure in digital systems used in nuclear power plants - 378

Digital technology has advantages over analog systems, including automated monitoring and alerts for standby safety functions, and predictive algorithms to maintain critical safety systems. Additionally, digital technology generally has higher reliability and can be designed to reduce single point vulnerabilities. For these reasons many nuclear plants have applied digital technology to safety and non-safety related applications, including reactor protection system, feedwater and turbine controls, etc. with a corresponding significant improvement in trip reduction. Nonetheless, digital instrumentation and control (I and C) systems also present potential new vulnerabilities that need to be assessed, including potential failures due to increased complexity of digital systems, the introduction of unique failure modes due to software (including software common cause failure (CCF)), and limited operating history of digital systems in nuclear safety related applications compared to analog systems. The fact that software is intangible means that common methods, such as analysis or testing, used for detecting CCF may not be effective when applied to software. Consequently, digital technology is perceived to pose a potential risk from the introduction of undetected systematic faults that could result in CCF. Despite the I and C system upgrades and modifications performed to date, the U.S. Nuclear Regulatory Commission (NRC) and industry stakeholders have identified the need to modernize the regulatory infrastructure to efficiently address risks associated with the use of digital technology for nuclear safety applications and address regulatory uncertainties. The NRC's current position on CCF is guided by the staff requirements memorandum (SRM) on SECY 93-087. The SRM provides specific acceptance criteria for the evaluation of CCF, which the staff implemented in the Branch Technical Position (BTP) 7-19. However, industry stakeholders have proposed using methods to characterize the likelihood of software CCF and eliminate it from further consideration in a defense-in-depth and diversity analysis. The NRC's current position does not consider these alternatives, and thus corresponding acceptance criteria is not currently available. The work discussed in this paper assesses the underlying technical basis associated with CCF, provides technical support for updating the NRC position and considers proposed methods for addressing potential CCF in digital systems while enhancing efficiency, clarity, and confidence. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technical Note: Spot characteristic stability for proton pencil beam scanning

Purpose: The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil beam scanning. Methods: A simple treatment plan was generated to produce an asymmetric 9-spot pattern distributed throughout a field of 16 × 18 cm for each of 18 proton energies (100.0–226.0 MeV). The delivered fluence distribution in air was measured using a phosphor screen based CCD camera at three planes perpendicular to the beam line axis (x-ray imaging isocenter and up/down stream 15.0 cm). The measured fluence distributions for each energy were analyzed using in-house programs which calculated the spot sizes and positional deviations of the Gaussian shaped spots. Results: Compared to the spot characteristic data installed into the treatment planning system, the 16-month averaged deviations of the measured spot sizes at the isocenter plane were 2.30% and 1.38% in the IEC gantry x and y directions, respectively. The maximum deviation was 12.87% while the minimum deviation was 0.003%, both at the upstream plane. After the collinearity of the proton and x-ray imaging system isocenters was optimized, the positional deviations of the spots were all within 1.5 mm for all three planes. During the site configuration update, spot positions were found to deviate by 6 mm until the tuning parameters file was properly restored. Conclusions: For this beam delivery system, it is recommended to perform a spot size and position check at least monthly and any time after a database update or cyclotron intervention occurs. A spot size deviation tolerance of <15% can be easily met with this delivery system. Deviations of spot positions were <2 mm at any plane up/down stream 15 cm from the isocenter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New printed circuit boards magnetic coils in the vacuum vessel of J-TEXT tokamak for position measurement

Four sets of magnetic diagnostic coils, which are printed on machinable ceramic printed circuit boards (PCB), are designed, fabricated, installed, and tested in the Joint Texas Experimental Tokamak (J-TEXT) vacuum vessel for detecting the plasma radial and vertical displacements relative to the geometric center of the vacuum vessel in Ohmic discharges. Each coordinate is determined by a pair of variable cross-section Rogowski and saddle coils, which measure the tangential and normal magnetic fields (relative to the coil surface). These coils are suitable for mass production and offer advantages in vacuum compatibility and temperature tolerance that are important for J-TEXT. Position measurements using PCB coils are compared with those from soft x-ray image system and match the position well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precessing Jet and Large Dust Grains in the V380 Ori NE Star-forming Region

The V380 Ori NE bipolar outflow was imaged in the SiO and CO J=1→0 lines, and dense cores in L1641 were observed in the 2.0–0.89 mm continuum. The highly collimated SiO jet shows point-symmetric oscillation patterns in both position and velocity, which suggests that the jet axis is precessing and the driving source may belong to a non-coplanar binary system. By considering the position and velocity variabilities together, accurate jet parameters were derived. The protostellar system is viewed nearly edge-on, and the jet has a flow speed of ∼35 km s{sup −1} and a precession period of ∼1600 years. The CO outflow length gives a dynamical timescale of ∼6300 years, and the protostar must be extremely young. The inferred binary separation of 6–70 au implies that this protobinary system may have been formed through the disk instability process. The continuum spectra of L1641 dense cores indicate that the emission comes from dust, and the fits with modified blackbody functions give emissivity power indices of β = 0.3–2.2. The emissivity index shows a positive correlation with the molecular line width, but no strong correlation with bolometric luminosity or temperature. V380 Ori NE has a particularly low value of β = 0.3, which tentatively suggests the presence of millimeter-sized dust grains. Because the dust growth takes millions of years, much longer than the protostellar age, this core may have produced large grains in the starless core stage. HH 34 MMS and HH 147 MMS also have low emissivity indices.

79 ASTRONOMY AND ASTROPHYSICS↗

Gaussian geometric discord of two-mode systems in a thermal environment

In the framework of the theory of open systems based on completely positive quantum dynamical semigroups, we give a description of the Gaussian geometric discord for a system consisting of two non-interacting non-resonant bosonic modes embedded in a thermal environment. We take as initial state of the system a two-mode squeezed thermal state and describe the time evolution of the Gaussian geometric discord under the influence of the thermal bath. By tracing the distance between the state of the considered subsystem and the closest classical-quantum Gaussian state we evaluate the Gaussian geometric discord for all times and temperatures. The geometric discord has finite values between 0 and 1 and decreases asymptotically to zero at large times and temperatures with oscillations on the time axis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Entanglement of formation in two-mode Gaussian systems in a thermal environment

In the framework of the theory of open systems based on completely positive quantum dynamical semigroups, we give a description of the continuous variable entanglement for a system consisting of two non-interacting bosonic modes embedded in a thermal environment. The calculated measure of entanglement is entanglement of formation. We describe the evolution of entanglement in terms of the covariance matrix for symmetric Gaussian input states. In the case of an entangled initial squeezed thermal state, entanglement suppression (entanglement sudden death) takes place, for all non-zero temperatures of the thermal bath. After that, the system remains for all times in a separable state. For a zero temperature of the thermal bath, the system remains entangled for all finite times, but in the limit of asymptotic large times the state becomes separable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Finite Hamiltonian systems: Linear transformations and aberrations

Finite Hamiltonian systems contain operators of position, momentum, and energy, having a finite number N of equally-spaced eigenvalues. Such systems are under the aeis of the algebra su(2), and their phase space is a sphere. Rigid motions of this phase space form the group SU(2); overall phases complete this to U(2). But since N-point states can be subject to U(N) superset of U(2) transformations, the rest of the generators will provide all N{sup 2} unitary transformations of the states, which appear as nonlinear transformations-aberrations-of the system phase space. They are built through the 'finite quantization' of a classical optical system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Local equilibrium and the second law of thermodynamics for irreversible systems with thermodynamic inertia

Validity of local equilibrium has been questioned for non-equilibrium systems which are characterized by delayed response. In particular, for systems with non-zero thermodynamic inertia, the assumption of local equilibrium leads to negative values of the entropy production, which is in contradiction with the second law of thermodynamics. In this paper, we address this question by suggesting a variational formulation of irreversible evolution of a system with non-zero thermodynamic inertia. We introduce the Lagrangian, which depends on the properties of the normal and the so-called “mirror-image” systems. We show that the standard evolution equations, in particular, the Maxwell-Cattaneo-Vernotte equation, can be derived from the variational procedure without going beyond the assumption of local equilibrium. We also argue that the second law of thermodynamics in non-equilibrium should be understood as a consequence of the variational procedure and the property of local equilibrium. For systems with instantaneous response this leads to the standard requirement of the local instantaneous entropy production being always positive. However, if a system is characterized by delayed response, the formulation of the second law of thermodynamics should be altered. In particular, the quantity, which is always positive, is not the instantaneous entropy production, but the entropy production averaged over a proper time interval.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial position optimization in molecular dynamics simulations for a Coulomb system

A new algorithm for molecular dynamics (MD) simulations is developed to optimize plasma particle distributions at given initial temperatures. By combining velocity scaling and reassignment, the method effectively eliminates the initial rise and oscillation in temperatures observed with randomly distributed positions. These rises and oscillations are undesired numerical artifacts observed in conventional plasma MD simulations, arising from unoptimized particle positions. The algorithm demonstrates temperature relaxation without initial rises or oscillations, as well as precise flow velocity relaxation, enabling accurate measurement of relaxation times. The code is accelerated using graphics processing units for parallel processing, enhancing the study of plasma dynamics. The proposed method for distributing physically valid particles in MD simulations enables accurate studies of intrinsic collision processes in plasmas, including the dynamics of strongly coupled plasmas, plasma–wave interactions, and transport phenomena in magnetized plasmas. The paper concludes with a discussion of potential applications and future enhancements to the algorithm.

Jo, Jawon (ORCID:0009000924193285)↗

Evolution of Quantum Entanglement in Open Systems

In the framework of the theory of open systems based on completely positive quantum dynamical semigroups, we give a description of the continuous-variable entanglement for a system consisting of two uncoupled harmonic oscillators interacting with a thermal environment. Using Peres-Simon necessary sufficient criterion for separability of two-mode Gaussian states, we show that for some values of diffusion coefficient, dissipation constant and temperature of the environment, the state keeps for all times its initial type: separable or entangled. In other cases, entanglement generation, entanglement sudden death or a periodic collapse revival of entanglement take place.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chaos control of parametric driven Duffing oscillators

Duffing resonators are typical dynamic systems, which can exhibit chaotic oscillations, subject to certain driving conditions. Chaotic oscillations of resonating systems with negative and positive spring constants are identified to investigate in this paper. Parametric driver imposed on these two systems affects nonlinear behaviours, which has been theoretically analyzed with regard to variation of driving parameters (frequency, amplitude). Systematic calculations have been performed for these two systems driven by parametric pumps to unveil the controllability of chaos.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Positive contraction mappings for classical and quantum Schrödinger systems

The classical Schrödinger bridge seeks the most likely probability law for a diffusion process, in path space, that matches marginals at two end points in time; the likelihood is quantified by the relative entropy between the sought law and a prior. Jamison proved that the new law is obtained through a multiplicative functional transformation of the prior. This transformation is characterised by an automorphism on the space of endpoints probability measures, which has been studied by Fortet, Beurling, and others. A similar question can be raised for processes evolving in a discrete time and space as well as for processes defined over non-commutative probability spaces. The present paper builds on earlier work by Pavon and Ticozzi and begins by establishing solutions to Schrödinger systems for Markov chains. Our approach is based on the Hilbert metric and shows that the solution to the Schrödinger bridge is provided by the fixed point of a contractive map. We approach, in a similar manner, the steering of a quantum system across a quantum channel. We are able to establish existence of quantum transitions that are multiplicative functional transformations of a given Kraus map for the cases where the marginals are either uniform or pure states. As in the Markov chain case, and for uniform density matrices, the solution of the quantum bridge can be constructed from the fixed point of a certain contractive map. For arbitrary marginal densities, extensive numerical simulations indicate that iteration of a similar map leads to fixed points from which we can construct a quantum bridge. For this general case, however, a proof of convergence remains elusive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-nanosecond delays of light emitted by streamer in atmospheric pressure air: Analysis of N{sub 2}(C{sup 3}Π{sub u}) and N{sub 2}{sup +}(B{sup 2}Σ{sub u}{sup +}) emissions and fundamental streamer structure

Theoretical analysis of ultra-short phenomena occurring during the positive streamer propagation in atmospheric pressure air is presented. Motivated by experimental results obtained with tens-of-picoseconds and tens-of-microns precision, it is shown that when the streamer head passes a spatial coordinate, emission maxima from N{sub 2} and N{sub 2}{sup +} radiative states follow with different delays. These different delays are caused by differences in the dynamics of populating the radiative states, due to different excitation and quenching rates. Associating the position of the streamer head with the maximum value of the self-enhanced electric field, a delay of 160 ps was experimentally found for the peak emission of the first negative system of N{sub 2}{sup +}. A delay dilatation was observed experimentally on early-stage streamers and the general mechanism of this phenomenon is clarified theoretically. In the case of the second positive system of N{sub 2}, the delay can reach as much as 400 ps. In contrast to the highly nonlinear behavior of streamer events, it is shown theoretically that emission maximum delays linearly depend on the ratio of the streamer radius and its velocity. This is found to be one of the fundamental streamer features and its use in streamer head diagnostics is proposed. Moreover, radially resolved spectra are synthesized for selected subsequent picosecond moments in order to visualize spectrometric fingerprints of radial structures of N{sub 2}(C{sup 3}Π{sub u}) and N{sub 2}{sup +}(B{sup 2}Σ{sub u}{sup +}) populations created by streamer-head electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Onboard functional and molecular imaging: A design investigation for robotic multipinhole SPECT

Purpose: Onboard imaging—currently performed primarily by x-ray transmission modalities—is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single photon emission computed tomography (SPECT), are premier modalities for molecular imaging. The purpose of this study is to investigate a robotic multipinhole approach to onboard SPECT. Methods: Computer-aided design (CAD) studies were performed to assess the feasibility of maneuvering a robotic SPECT system about a patient in position for radiation therapy. In order to obtain fast, high-quality SPECT images, a 49-pinhole SPECT camera was designed which provides high sensitivity to photons emitted from an imaging region of interest. This multipinhole system was investigated by computer-simulation studies. Seventeen hot spots 10 and 7 mm in diameter were placed in the breast region of a supine female phantom. Hot spot activity concentration was six times that of background. For the 49-pinhole camera and a reference, more conventional, broad field-of-view (FOV) SPECT system, projection data were computer simulated for 4-min scans and SPECT images were reconstructed. Hot-spot localization was evaluated using a nonprewhitening forced-choice numerical observer. Results: The CAD simulation studies found that robots could maneuver SPECT cameras about patients in position for radiation therapy. In the imaging studies, most hot spots were apparent in the 49-pinhole images. Average localization errors for 10-mm- and 7-mm-diameter hot spots were 0.4 and 1.7 mm, respectively, for the 49-pinhole system, and 3.1 and 5.7 mm, respectively, for the reference broad-FOV system. Conclusions: A robot could maneuver a multipinhole SPECT system about a patient in position for radiation therapy. The system could provide onboard functional and molecular imaging with 4-min scan times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗