Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Development of Protective Coatings for Co-Sequestration Processes and Pipelines

The program, entitled Development of Protective Coatings for Co-Sequestration Processes and Pipelines, examined the sensitivity of existing coating systems to supercritical carbon dioxide (SCCO2) exposure and developed new coating system to protect pipelines from their corrosion under SCCO2 exposure. A literature review was also conducted regarding pipeline corrosion sensors to monitor pipes used in handling co-sequestration fluids. Research was to ensure safety and reliability for a pipeline involving transport of SCCO2 from the power plant to the sequestration site to mitigate the greenhouse gas effect. Results showed that one commercial coating and one designed formulation can both be supplied as potential candidates for internal pipeline coating to transport SCCO2.

36 MATERIALS SCIENCE↗

Radiation Protection Instrument Reliability and Maintainability Data

This report is a collection of reliability and maintenance data on several types of radiation protection instrumentation. Some radiation detectors are used for personnel safety; others are used for environmental stewardship. Six types of instruments are addressed in this report. These are: continuous air monitors, tritium room air monitors, facility vent stack monitors, tritium bubbler monitors, tritium in effluent water monitors, and general purpose radiation survey meters. Literature searches, operating experience data, and occurrence reports were used to identify failure modes and to estimate quantitative failure rates for several general types of radiation protection instruments. Likewise, data on instrument repair has been found when possible and used to estimate the mean time to repair. These data can be useful for facility safety assessment, personnel safety assessment, environment assessment, and for equipment and labor planning purposes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Requirements for CEC POP Machine Protection System

The requirements of CEC POP machine protection system are meant to prevent damage to a vacuum chamber by a missteered electron beam. In this example, beam energy = 22 MeV, Maximal bunch charge = 5 nC, Maximal repetition rate = 78 kHz, Normalized emittance = 5 mm mrad, Minimal β-function = 1 m. From this information the requirements of the protection system can be calculated by factoring the information into equations to find beam densities and temperature excursions.

43 PARTICLE ACCELERATORS↗

Application of Advanced Wide Area Early Warning Systems with Adaptive Protection

Recent blackouts of power systems in North America and throughout the world have shown how critical a reliable power system is to modern societies, and the enormous economic and societal damage a blackout can cause. It has been noted that unanticipated operation of protection systems can contribute to cascading phenomena and, ultimately, blackouts. This project developed and field-tested two methods of Adaptive Protection systems utilizing synchrophasor data. One method detects conditions of system stress that can lead to unintended relay operation, and initiates a supervisory signal to modify relay response in real time to avoid false trips. The second method detects the possibility of false trips of impedance relays as stable system swings “encroach” on the relays’ impedance zones, and produces an early warning so that relay engineers can re-evaluate relay settings. In addition, real-time synchrophasor data produced by this project was used to develop advanced visualization techniques for display of synchrophasor data to utility operators and engineers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Office of River Protection Advanced Low-Activity Waste Glass Research and Development Plan

The U.S. Department of Energy Office of River Protection (ORP) has initiated and leads an integrated Advanced Waste Glass (AWG) program to increase the loading of Hanford tank wastes in glass while meeting melter lifetime expectancies and process, regulatory, and product performance requirements. The integrated ORP program is focused on providing a technical, science-based foundation for making key decisions regarding the successful operation of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) facilities in the context of an optimized River Protection Project (RPP) flowsheet. The fundamental data stemming from this program will support development of advanced glass formulations, key product performance and process control models, and tactical processing strategies to ensure safe and successful operations for both the low-activity waste (LAW) and high-level waste vitrification facilities. These activities will be conducted with the objective of improving the overall RPP mission by enhancing flexibility and reducing cost and schedule.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Office of River Protection Advanced Low-Activity Waste Glass Research and Development Plan

The U.S. Department of Energy Office of River Protection (ORP) has initiated and leads an integrated Advanced Waste Glass (AWG) program to increase the loading of Hanford tank wastes in glass while meeting melter lifetime expectancies and process, regulatory, and product performance requirements. The integrated ORP program is focused on providing a technical, science-based foundation for making key decisions regarding the successful operation of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) facilities in the context of an optimized River Protection Project (RPP) flowsheet. The fundamental data stemming from this program will support development of advanced glass formulations, key product performance and process control models, and tactical processing strategies to ensure safe and successful operations for both the low-activity waste (LAW) and high-level waste vitrification facilities. These activities will be conducted with the objective of improving the overall RPP mission by enhancing flexibility and reducing cost and schedule. The purpose of this advanced LAW glass research and development plan is to identify the near-term, mid-term, and longer-term research and development activities required to develop and validate advanced LAW glasses, property-composition models and their uncertainties, and an advanced glass algorithm to support WTP facility operations, including both Direct Feed LAW and full pretreatment flowsheets. Data are needed to develop, validate, and implement 1) new glass property-composition models and 2) a new glass formulation algorithm. Hence, this plan integrates specific studies associated with increasing the Na2O and SO3/halide concentrations in glass, because these components will ultimately dictate waste loadings for LAW vitrification. Of equal importance is the development of an efficient and economic strategy for 99Tc management. Specific and detailed studies are being implemented to understand the fate of Tc throughout the WTP flowsheet and the underlying mechanisms that dictate its partitioning between streams within the LAW vitrification facility. These studies are aimed at increasing the single-pass Tc retention in glass and the potential use of high-temperature mineral phases to capture Tc. The Tc-bearing mineral phases would be thermally stable and resistant to Tc release during feed melting reactions or they could serve as alternative waste forms. The LAW glass research and development is focused on reducing the total volume of LAW glass produced and minimizing the impact of (or potentially eliminating) the need for recycle.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Technical Meeting To Compare US/French Approaches for Physical Protection Test Beds

In September 2015, representatives of the US Department of Energy/National Nuclear Security Administration, including test bed professionals from Sandia National Laboratories, and representatives of the French Alternative Energies and Atomic Energy Commission participated in a one-week workshop to share best practices in design, organization, operations, utilization, improvement, and performance testing of physical protection test beds. The intended workshop outcomes were to (1) share methods of improving respective test bed methodologies and programs and (2) prepare recommendations for standards regarding creating and operating testing facilities for nations new to nuclear operations. At the workshop, the French and American subject matter experts compared best practices as developed at their respective test bed sites; discussed access delay test bed considerations; and presented the limitations/ constraints of physical protection test beds.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Strategies, Protections and Mitigations for Electric Grid from Electromagnetic Pulse Effects

The mission of DOE’s Office of Electricity Delivery and Energy Reliability (OE) is to lead national efforts to modernize the electricity delivery system, enhance the security and reliability of America’s energy infrastructure and facilitate recovery from disruptions to the energy supply. One of the threats OE is concerned about is a high-altitude electro-magnetic pulse (HEMP) from a nuclear explosion and eletro-magnetic pulse (EMP) or E1 pulse can be generated by EMP weapons. DOE-OE provides federal leadership and technical guidance in addressing electric grid issues. The Idaho National Laboratory (INL) was chosen to conduct the EMP study for DOE-OE due to its capabilities and experience in setting up EMP experiments on the electric grid and conducting vulnerability assessments and developing innovative technology to increase infrastructure resiliency. This report identifies known impacts to EMP threats, known mitigations and effectiveness of mitigations, potential cost of mitigation, areas for government and private partnerships in protecting the electric grid to EMP, and identifying gaps in our knowledge and protection strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HVOF Thermal Spray TiC/TiB 2 Coatings for AUSC Boiler/Turbine Components for Enhanced Corrosion Protection

The high temperatures of operations still pose significant risk of degradation and fatigue from oxidizing, corroding and eroding environment. In addition to unused O 2 , water from combustion and SO x from the coal sulfur oxidation that result in highly corrosive environment, acid gases such as HCl and other sulfur compounds may also be present. These adverse effects are further accelerated due to the elevated temperatures. In addition, ash particulates and unburnt carbon and pyritic sulfur can cause erosion of the surface and thus loss of material. Unburnt carbon and pyritic sulfur may also cause localized reduction sites. Thus, fireside corrosion protection and steam oxidation protection alternatives to currently used Ni-Cr overlays need to be identified and evaluated. Titanium carbide (TiC) is a suitable alternative on account of the material features such as the high hardness, the high melting point, the high strength and the low density for the substitution or to be used in conjunction with NiCr for enhancing the fireside corrosion and erosion of the materials. Another alternative is the use of titanium boride as a coating for chemical stability required for long-term service and high erosion resistance over the state-of-the-art, high fracture toughness (K 1C ~12 MPam 1/2 ) and excellent corrosion resistance (kp~1.9X10 -11 g 2 /cm 4 /s at 800°C in air). The overarching aim of the research endeavor was to synthesize oxidation, corrosion and wear resistant TiC and TiB 2 coating powders, apply thermal spray coating on existing boiler materials and characterize the coated substrates for corrosion resistance for applications at high temperatures (500 -750 °C) and high pressures (~350 bars) using the HVOF process and to demonstrate the feasibility of these coating to be used in AUSC boilers and turbines.

20 FOSSIL-FUELED POWER PLANTS↗

Protection of Lithium (Li) Anodes Using Dual Phase Electrolytes

Sion Power focused on metallic lithium anode protection, employing the Dual-Phase Electrolyte approach. The objective of this project was to develop a unique electrolyte providing two liquid phases having good Li+ conductivity, self-partitioning and immiscibility, serving separately the cathode and anode electrodes. This Dual-Phase Electrolyte was combined with thin film multi-layer, physical barrier membranes developed partially under a separate ARPA-E funded project. All these protective structures were stabilized by externally applied pressure. This strategy was used for Li-S cells. The development directly addressed cell safety, particularly higher thermal stability, while also allowing higher energies and cycle life. Safety tests showed that 100% of cells with Dual-Phase Electrolyte were intact and did not exhibit thermal runaway up to 178 °C and thus met the project objective of increasing the runaway temperature to >165°C. Cells also passed cycling at USABC Dynamic Stress Test conditions developed for Electric Vehicle applications and generated specific energy > 300 Wh/kg.

36 MATERIALS SCIENCE↗

Evaluate the role of organic acids in the protection of ligands from radiolytic degradation

In the Advanced TALSPEAK process, the bis(2-ethylhexyl)phosphoric acid (HDEHP) extractant used in the traditional TALSPEAK process is replaced by the extractant 2-ethylhexylphosphonic acid mono-2-ethylhexyl ester (HEH[EHP]). In addition, the aqueous phase complexant and buffer used in traditional TALSPEAK is replaced with the combination of N-(2-hydroxyethyl)ethylenediamine-N,N’,N’-triacetic acid (HEDTA) and citric acid. In order to evaluate the possible impacts of gamma radiolysis upon the efficacy of the Advanced TALSPEAK flowsheet, aqueous and organic phases corresponding to the extraction section of the proposed flowsheet were irradiated in the INL test loop under an ambient atmosphere. The results of these studies conducted at INL, led INL researchers to conclude that the scarcity of values of rate constants for the reaction of hydroxyl radical with the components of the Advanced TALSPEAK process chemistry was severely limiting the interpretation of the results of radiolysis studies performed at the INL. In this work, the rate of reaction of hydroxyl radical with citric acid at several pH values was measured using a competitive pulse radiolysis technique. This report describes those results and is written in completion of milestone M3FT-16IN030102028, the goal of which was to evaluate the role of organic acids in the protection of ligands from radiolytic degradation. The results reported here demonstrate the importance of obtaining hydroxyl radical reaction rate data for the conditions that closely resemble actual solution conditions expected to be used in an actual solvent extraction process. This report describes those results and is written in completion of milestone M3FT-16IN030102028, the goal of which was to evaluate the role of organic acids in the protection of ligands from radiolytic degradation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and Testing of Protection Scheme for Renewable-Rich Distribution System

As the penetration of renewables increases in the distribution systems, and microgrids are conceived with high penetration of such generation that connects through inverters, fault location and protection of microgrids needs consideration. This report proposes averaged models that help simulate fault scenarios in renewable-rich microgrids, models for locating faults in such microgrids, and comments on the protection models that may be considered for microgrids. Simulation studies are reported to justify the models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Cost HTS Based Magnet System with an Inductively Coupled Pulsed Energy Extraction Protection System

In this project, RadiaBeam Technologies was tasked with developing a novel solution for a cost effective quench protection based on fast expansion of the normal zone. By inductively coupling a strong electromagnetic pulse via a resonant LC circuit, we attempted to demonstrate accelerated normal zone propagation. The AC field induces currents in the superconducting layer with the current density exceeding that of the critical current density, J c . This creates a large normal zone, uniformly distributing the dissipation through the magnet body. The method does not rely on thermal heating of the conductor, thus enabling nearly instantaneous protection. Through the course of the Phase II project, RadiaBeam Technologies continued extensive numerical modeling of the inductive quench system, re-designed and built several iterations of the POC system for testing and observed evidence of a transient partial quench being induced. However the final device was not fabricated. This was a consequence of the fundamentally complex nature of the energy extraction process and the challenges associated even with demonstrating the proof of concept in a bench top device.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Considerations for NSLS-II Synchrotron Radiation Protection When Operating Damping Wigglers at Low Machine Energy

The NSLS-II storage ring vacuum chamber, including frontends (FE) and beamlines (BL), is protected from possible damage from synchrotron radiation (SR) emitted from insertion devices (IDs) by a dedicated active interlock system (AIS). The system monitors electron beam position and angle and triggers a beam dump if the beam orbit is outside of the active interlock envelope (AIE). The AIE was calculated under the assumptions of 3 GeV beam energy and ID gaps set to their minimum operating values (i.e. “fully closed”). Recently it was proposed to perform machine studies that would ramp the stored beam energy significantly below the nominal operational value of 3 GeV. These studies may potentially include the use of NSLS-II damping wigglers (DWs) for electron beam emittance reduction and control. These DWs have the minimum operating gap of g min =15 mm with the corresponding peak magnetic field B 0 =1.8 T. During regular machine operations or studies at 3 GeV, DWs are usually held at this minimum gap (thus maximum field), or, alternatively, they are fully opened to the gap of 150 mm, which corresponds to a negligible residual magnetic field. However, any intermediate values of wiggler gap can be easily set through the control system with micron level precision, so wiggler fields in the range of 0< B < B 0 can be precisely set and maintained. For the low energy studies two likely modes of DW operation must be considered: 1) the maximum allowable wiggler filed is proportional to the storage ring energy, B ( E )= B 0 E /E 0 ; and 2) the maximum allowable wiggler field (and thus the minimum allowable gap) is energy independent and is equal to its nominal 3 GeV value of 1.8 T (i.e. wiggler gap is fixed at 15 mm). The aim of this technical note is to consider the synchrotron radiation protection (SRP) implications of DW use during low energy machine studies, when DWs are operated in either of these two modes. For consistency with earlier SRP documents we will quote all the powers and power densities at the nominal NSLS-II design beam current of 500 mA, even though the low energy studies will be done at significantly lower beam currents, hence the SR power will be proportionally smaller.

36 MATERIALS SCIENCE↗

Equipment Protection System for CBETA

The ultimate goal of CBETA is to be the first high-current multi turn Energy Recovery Linac operating at 40 mA. The power of highest energy beam at this configuration is going to be 6 MW. Hence equipment protection against radiation is an important issue. Through our stages of commissioning we will slowly increase the beam current, starting from 100 pA all the way to 1 mA during the current commissioning phase. The electron beams hitting any in-vacuum component either on purpose (e.g. view screens, beam stops or during commissioning) or due to some component failure will generate a radiation shower which has the potential to damage various parts of the accelerator. In this document, we describe the various scenarios which generate unwanted radiation in our machine and list the damage thresholds of critical components. Then we discuss our diagnostic systems which can detect component failure and the resulting radiation generated. We further list the possible beam modes of the machine which we have designed taking into account the damage thresholds and the sensitivity of the diagnostics. Finally, we document our design of the Equipment Protection System (EPS) and outline protocols of calibration and operation.

43 PARTICLE ACCELERATORS↗

Evaluating Admittance Relaying for Inverter-Interfaced Microgrid Protection [Slides]

Admittance protection with current compensation is viable for inverter-interfaced microgrids. A downside is that pilot relaying is likely required given short line lengths & change in system configuration from switching – operating area will be large compared to the line impedance. If a communications channel is required, there are more sophisticated methods such as state-estimation based protection that can operate with the failure of one or more sensors.

42 ENGINEERING↗

Evaluation of an Additively Manufactured Respirator for Personnel Protection from Particulates

Additively manufactured respirators (AMRs) made using rigid plastic can be fitted with repurposed filter media to yield a wearable mask capable of passing a quantitative fit test with criteria set for commercial, N95 health care particulate respirators. This has been verified through an evaluation study assessing AMR masks fabricated using open-source design files and a commercial fused-filament fabrication machine, using N95 filter cloth and a P100 respirator cartridge. A few examples of filter media not designed for human respiratory protection were also evaluated in an AMR mask but did not demonstrate filtering sufficient to pass the N95 test criteria. All attributes of an AMR mask system must be considered during design and when testing performance, including the mask frame, gasket, and the cord used to secure the mask to the face. AMR masks are not the same as commercially available respiratory masks. If AMR masks are used as personal protective equipment (PPE) during a crisis when there is a shortage of regular PPE it is important that wearers are fully informed of the differences, tradeoffs, and risks associated with their use. Quantitative fit testing and proper training on how to don and doff the AMR mask are important to help achieve the best possible outcome when they are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HEMP Testing of Substation Yard Circuit Breaker Control and Protective Relay Circuits

There are concerns about the effects of High-Altitude Electromagnetic Pulses (HEMP) on the electric power grid. Activities to date tested and analyzed vulnerability of digital protective relays (DPRs) used in power substations, but the effect of HEMP on the greater substation environment is not well known. This work establishes a method of testing the vulnerability of circuit breaker control and protective relay circuits to the radiated E1 pulse associated with HEMP based on coupling to the cables in a substation yard. Two DPRs from Schweitzer Engineering Laboratories, Inc. were independently tested. The test setup also included a typical cable in a substation yard with return plane to emulate the ground grid and other ground conductors near the yard cable, cabinetry housing the installed DPRs, station battery and battery charger, terminal block elements, and a breaker simulator to emulate a substation yard configuration. The DPRs were powered from the station battery and the transformer inputs energized with a three-phase source to maintain typical operating conditions during the tests. Vulnerability testing consisted of a conducted E1 pulse injected into the center of the yard cable of the DPR circuits. Current measurements on the yard cable and DPR inputs indicated significant attenuation of the conducted pulse arriving at the control house equipment from the emulated substation yard. This reduction was quantified with respect to the equivalent open-circuit voltage on the yard cable. No equipment damage or undesired operation occurred on the tested circuits for values below 180 kV, which is significantly higher than the anticipated coupling to a substation yard cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗