Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Mild Toxicity and Favorable Prognosis of High-Dose and Extended Involved-Field Intensity-Modulated Radiotherapy for Patients With Early-Stage Nasal NK/T-Cell Lymphoma

Purpose: The value of intensity-modulated radiotherapy (IMRT) for early-stage nasal NK/T-cell lymphoma has not been previously reported. The aim of the present study was to assess the dosimetric parameters, toxicity, and treatment outcomes of patients with nasal NK/T-cell lymphoma. Methods and Materials: Between 2003 and 2008, 42 patients with early-stage nasal NK/T-cell lymphoma underwent definitive high-dose and extended involved-field IMRT with or without combination chemotherapy. The median radiation dose to the primary tumor was 50 Gy. The dose-volume histograms of the target volume and critical normal structures were evaluated in all patients. The locoregional control, overall survival, and progression-free survival were calculated using the Kaplan-Meier method. Results: The average mean dose delivered to the planning target volume was 55.5 Gy. Only 1.3% and 2.5% of the planning target volume received <90% and 95% of the prescribed dose, respectively, indicating excellent planning target volume coverage. The mean dose and average dose to the parotid glands was 15 Gy and 14 Gy, respectively. With a median follow-up time of 27 months, the 2-year locoregional control, overall survival, and progression-free survivalrate was 93%, 78%, and 74%, respectively. No Grade 4 or 5 acute or late toxicity was reported. Conclusions: High-dose and extended involved-field IMRT for patients with early-stage nasal NK/T-cell lymphoma showed favorable locoregional control, overall survival, and progression-free survival, with mild toxicity. The dose constraints of IMRT for the parotid glands can be limited to <20 Gy in these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Escalation Study for Cardiac Radiosurgery in a Porcine Model

Purpose: To perform a proof-of-principle dose-escalation study to radiosurgically induce scarring in cardiac muscle tissue to block veno-atrial electrical connections at the pulmonary vein antrum, similar to catheter ablation. Methods and Materials: Nine mini-pigs underwent pretreatment magnetic resonance imaging (MRI) evaluation of heart function and electrophysiology assessment by catheter measurements in the right superior pulmonary vein (RSPV). Immediately after examination, radiosurgery with randomized single-fraction doses of 0 and 17.5-35 Gy in 2.5-Gy steps were delivered to the RSPV antrum (target volume 5-8 cm{sup 3}). MRI and electrophysiology were repeated 6 months after therapy, followed by histopathologic examination. Results: Transmural scarring of cardiac muscle tissue was noted with doses ≥32.5 Gy. However, complete circumferential scarring of the RSPV was not achieved. Logistic regressions showed that extent and intensity of fibrosis significantly increased with dose. The 50% effective dose for intense fibrosis was 31.3 Gy (odds ratio 2.47/Gy, P<.01). Heart function was not affected, as verified by MRI and electrocardiogram evaluation. Adjacent critical structures were not damaged, as verified by pathology, demonstrating the short-term safety of small-volume cardiac radiosurgery with doses up to 35 Gy. Conclusions: Radiosurgery with doses >32.5 Gy in the healthy pig heart can induce circumscribed scars at the RSPV antrum noninvasively, mimicking the effect of catheter ablation. In our study we established a significant dose-response relationship for cardiac radiosurgery. The long-term effects and toxicity of such high radiation doses need further investigation in the pursuit of cardiac radiosurgery for noninvasive treatment of atrial fibrillation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-45: Sparing Normal Tissue with Ultra-High Dose Rate in Radiation Therapy

Purpose: To spare normal tissue by reducing the location uncertainty of a moving target, we proposed an ultra-high dose rate system and evaluated. Methods: High energy electrons generated with a linear accelerator were injected into a storage ring to be accumulated. The number of the electrons in the ring was determined based on the prescribed radiation dose. The dose was delivered within a millisecond, when an online imaging system found that the target was in the position that was consistent with that in a treatment plan. In such a short time period, the displacement of the target was negligible. The margin added to the clinical target volume (CTV) could be reduced that was evaluated by comparing of volumes between CTV and ITV in 14 cases of lung stereotactic body radiation therapy (SBRT) treatments. A design of the ultra-high dose rate system was evaluated based clinical needs and the recent developments of low energy (a few MeV) electron storage ring. Results: This design of ultra-high dose rate system was feasible based on the techniques currently available. The reduction of a target volume was significant by reducing the margin that accounted the motion of the target. ∼50% volume reduction of the internal target volume (ITV) could be achieved in lung SBRT treatments. Conclusion: With this innovation of ultra-high dose rate system, the margin of target is able to be significantly reduced. It will reduce treatment time of gating and allow precisely specified gating window to improve the accuracy of dose delivering.

60 APPLIED LIFE SCIENCES↗

Effects of sparse sampling schemes on image quality in low-dose CT

Purpose: Various scanning methods and image reconstruction algorithms are actively investigated for low-dose computed tomography (CT) that can potentially reduce a health-risk related to radiation dose. Particularly, compressive-sensing (CS) based algorithms have been successfully developed for reconstructing images from sparsely sampled data. Although these algorithms have shown promises in low-dose CT, it has not been studied how sparse sampling schemes affect image quality in CS-based image reconstruction. In this work, the authors present several sparse-sampling schemes for low-dose CT, quantitatively analyze their data property, and compare effects of the sampling schemes on the image quality.Methods: Data properties of several sampling schemes are analyzed with respect to the CS-based image reconstruction using two measures: sampling density and data incoherence. The authors present five different sparse sampling schemes, and simulated those schemes to achieve a targeted dose reduction. Dose reduction factors of about 75% and 87.5%, compared to a conventional scan, were tested. A fully sampled circular cone-beam CT data set was used as a reference, and sparse sampling has been realized numerically based on the CBCT data.Results: It is found that both sampling density and data incoherence affect the image quality in the CS-based reconstruction. Among the sampling schemes the authors investigated, the sparse-view, many-view undersampling (MVUS)-fine, and MVUS-moving cases have shown promising results. These sampling schemes produced images with similar image quality compared to the reference image and their structure similarity index values were higher than 0.92 in the mouse head scan with 75% dose reduction.Conclusions: The authors found that in CS-based image reconstructions both sampling density and data incoherence affect the image quality, and suggest that a sampling scheme should be devised and optimized by use of these indicators. With this strategic approach, one can acquire optimally sampled sparse data so that the CS-based algorithms can best perform in terms of image quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-166: On the Nature of the Background Visible Light Observed in Fiber Optic Dosimetry of Proton Beams

Purpose: The nature of the background visible light observed during fiber optic dosimetry of proton beams, whether it is due to Cherenkov radiation or not, has been debated in the literature recently. In this work, experimentally and by means of Monte Carlo simulations, we shed light on this problem and investigated the nature of the background visible light observed in fiber optics irradiated with proton beams. Methods: A bare silica fiber optics was embedded in tissue-mimicking phantoms and irradiated with clinical proton beams with energies of 100–225 MeV at Roberts Proton Therapy Center. Luminescence spectroscopy was performed by a CCD-coupled spectrograph to analyze in detail the emission spectrum of the fiber tip across the visible range of 400–700 nm. Monte Carlo simulation was performed by using FLUKA Monte Carlo code to simulate Cherenkov light and ionizing radiation dose deposition in the fiber. Results: The experimental spectra of the irradiated silica fiber shows two distinct peaks at 450 and 650 nm, whose spectral shape is different from that of Cherenkov radiation. We believe that the nature of these peaks are connected to the point defects of silica including oxygen-deficiency center (ODC) and non-bridging oxygen hole center (NBOHC). Monte Carlo simulations confirmed the experimental observations that Cherenkov radiation cannot be solely responsible for such a signal. Conclusion: We showed that Cherenkov radiation is not the dominant visible signal observed in bare fiber optics irradiated with proton beams. We observed two distinct peaks at 450 and 650 nm whose nature is connected with the point defects of silica fiber including oxygen-deficiency center and non-bridging oxygen hole center.

60 APPLIED LIFE SCIENCES↗

On the role of ion-based imaging methods in modern ion beam therapy

External beam radiotherapy techniques have the common aim to maximize the radiation dose to the target while sparing the surrounding healthy tissues. The inverted and finite depth-dose profile of ion beams (Bragg peak) allows for precise dose delivery and conformai dose distribution. Furthermore, increased radiobiological effectiveness of ions enhances the capability to battle radioresistant tumors. Ion beam therapy requires a precise determination of the ion range, which is particularly sensitive to range uncertainties. Therefore, novel imaging techniques are currently investigated as a tool to improve the quality of ion beam treatments. Approaches already clinically available or under development are based on the detection of secondary particles emitted as a result of nuclear reactions (e.g., positron-annihilation or prompt gammas, charged particles) or transmitted high energy primary ion beams. Transmission imaging techniques make use of the beams exiting the patient, which have higher initial energy and lower fluence than the therapeutic ones. At the Heidelberg Ion Beam Therapy Center, actively scanned energetic proton and carbon ion beams provide an ideal environment for the investigation of ion-based radiography and tomography. This contribution presents the rationale of ion beam therapy, focusing on the role of ion-based transmission imaging methods towards the reduction of range uncertainties and potential improvement of treatment planning.

60 APPLIED LIFE SCIENCES↗

On-Chip p-MOSFET Dosimetry

On-chip p-FETs were developed to monitor the radiation dose of n-well CMOS ICs by monitoring threshold voltage shifts due to radiation induced oxide and interface charge.

FETs↗

TH-AB-207A-06: The Use of Realistic Phantoms to Predict CT Dose to Pediatric Patients

Purpose: To predict pediatric patient dose from diagnostic CT scans using Monte Carlo simulation of realistic reference phantoms of various ages, weights, and heights. Methods: A series of deformable pediatric reference phantoms using Non-Uniform Rational B-Splines (NURBS) was developed for a large range of ages, percentiles, and reference anatomy. Individual bones were modeled using age-dependent factors, and red marrow was modeled as functions of age and spatial distribution based on Cristy1. Organ and effective doses for the phantom series were calculated using Monte Carlo simulation of chest, abdominopelvic, and chest-abdomen-pelvis CT exams. Non-linear regression was performed to determine the relationship between dose-length-product (DLP)-normalized organ and effective doses and phantom diameter. Patient-specific voxel computational phantoms were also created by manual segmentation of previously acquired CT images for 40 pediatric patients (0.7 to 17 years). Organ and effective doses were determined by Monte Carlo simulation of these patient-specific phantoms. Each patient was matched to the closest pediatric reference phantom based primarily on age and diameter for all major organs within the torso. Results: A total of 80 NURBS phantoms were created ranging from newborn to 15 years with height/weight percentiles from 10 to 90%. Organ and effective dose normalized by DLP correlated strongly with exponentially decreasing average phantom diameter (R{sup 2} > 0.95 for most organs). A similar relationship was determined for the patient-specific voxel phantoms. Differences between patient-phantom matched organ-dose values ranged from 0.37 to 2.39 mGy (2.87% to 22.1%). Conclusion: Dose estimation using NURBS-based pediatric reference phantoms offers the ability to predict patient dose before and after CT examinations, and physicians and scientists can use this information in their analysis of dose prescriptions for particular subjects and study types. This may lead to practices that minimize radiation dose while still achieving high quality images and, ultimately, improved patient care. NIH/NCI 1 R01 CA155400-01A1.

60 APPLIED LIFE SCIENCES↗

Physiologically gated microbeam radiation using a field emission x-ray source array

Purpose: Microbeam radiation therapy (MRT) uses narrow planes of high dose radiation beams to treat cancerous tumors. This experimental therapy method based on synchrotron radiation has been shown to spare normal tissue at up to 1000 Gy of peak entrance dose while still being effective in tumor eradication and extending the lifetime of tumor-bearing small animal models. Motion during treatment can lead to significant movement of microbeam positions resulting in broader beam width and lower peak to valley dose ratio (PVDR), which reduces the effectiveness of MRT. Recently, the authors have demonstrated the feasibility of generating microbeam radiation for small animal treatment using a carbon nanotube (CNT) x-ray source array. The purpose of this study is to incorporate physiological gating to the CNT microbeam irradiator to minimize motion-induced microbeam blurring. Methods: The CNT field emission x-ray source array with a narrow line focal track was operated at 160 kVp. The x-ray radiation was collimated to a single 280 μm wide microbeam at entrance. The microbeam beam pattern was recorded using EBT2 Gafchromic{sup ©} films. For the feasibility study, a strip of EBT2 film was attached to an oscillating mechanical phantom mimicking mouse chest respiratory motion. The servo arm was put against a pressure sensor to monitor the motion. The film was irradiated with three microbeams under gated and nongated conditions and the full width at half maximums and PVDRs were compared. An in vivo study was also performed with adult male athymic mice. The liver was chosen as the target organ for proof of concept due to its large motion during respiration compared to other organs. The mouse was immobilized in a specialized mouse bed and anesthetized using isoflurane. A pressure sensor was attached to a mouse's chest to monitor its respiration. The output signal triggered the electron extraction voltage of the field emission source such that x-ray was generated only during a portion of the mouse respiratory cycle when there was minimum motion. Parallel planes of microbeams with 12.4 Gy/plane dose and 900 μm pitch were delivered. The microbeam profiles with and without gating were analyzed using γ-H2Ax immunofluorescence staining. Results: The phantom study showed that the respiratory motion caused a 50% drop in PVDR from 11.5 when there is no motion to 5.4, whereas there was only a 5.5% decrease in PVDR for gated irradiation compared to the no motion case. In thein vivo study, the histology result showed gating increased PVDR by a factor of 2.4 compared to the nongated case, similar to the result from the phantom study. The full width at tenth maximum of the microbeam decreased by 40% in gating in vivo and close to 38% with phantom studies. Conclusions: The CNT field emission x-ray source array can be synchronized to physiological signals for gated delivery of x-ray radiation to minimize motion-induced beam blurring. Gated MRT reduces valley dose between lines during long-time radiation of a moving object. The technique allows for more precise MRT treatments and makes the CNT MRT device practical for extended treatment.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-08: A Validation Study of a Commercially Available Software Package's Absorbed Dose Estimates in a Physical Phantom

Purpose: This study assesses the accuracy of the absorbed dose estimates from CT scans generated by Monte Carlo (MC) simulation using a commercially available radiation dose monitoring software program. Methods: Axial CT studies of an anthropomorphic abdomen phantom with dose bores at a central location and 4 peripheral locations were conducted using a fixed tube current at 120 kV. A 100 mm ion chamber and a 0.6 cc ion chamber calibrated at diagnostic energy levels were used to measure dose in the phantom at each of the 5 dose bore locations. Simulations using the software program's Monte Carlo engine were run using a mathematical model of the anthropomorphic phantom to determine conversion coefficients between the CTDIvol used for the study and the dose at the location of the dose bores. Simulations were conducted using both the software's generic CT beam model and a refined model generated using HVL and bow tie filter profile measurements made on the scanner used for the study. Results: Monte Carlo simulations completed using the generalized beam model differed from the measured conversion factors by an absolute value average of 13.0% and 13.8% for the 100 mm and 0.6 cc ion chamber studies, respectively. The MC simulations using the scanner specific beam model generated conversion coefficients that differed from the CTDIvol to measured dose conversion coefficients by an absolute value average of 7.3% and 7.8% for the 100 mm and 0.6 cc ion chamber cases, respectively. Conclusion: A scanner specific beam model used in MC simulations generates more accurate dose conversion coefficients in an anthropomorphic phantom than those generated with a generalized beam model. Agreement between measured conversion coefficients and simulated values were less than 20% for all positions using the universal beam model.

07 ISOTOPE AND RADIATION SOURCES↗

Hypopharyngeal Dose Is Associated With Severe Late Toxicity in Locally Advanced Head-and-Neck Cancer: An RTOG Analysis

Purpose: Concurrent chemoradiation therapy (CCRT) for squamous cell carcinoma of the head and neck (SCCHN) increases local tumor control but at the expense of increased toxicity. We recently showed that several clinical/pretreatment factors were associated with the occurrence of severe late toxicity. This study evaluated the potential relationship between radiation dose delivered to the pharyngeal wall and toxicity. Methods and Materials: This was an analysis of long-term survivors from 3 previously reported Radiation Therapy Oncology Group (RTOG) trials of CCRT for locally advanced SCCHN (RTOG trials 91-11, 97-03, and 99-14). Severe late toxicity was defined in this secondary analysis as chronic grade 3-4 pharyngeal/laryngeal toxicity and/or requirement for a feeding tube {>=}2 years after registration and/or potential treatment-related death (eg, pneumonia) within 3 years. Radiation dosimetry (2-dimensional) analysis was performed centrally at RTOG headquarters to estimate doses to 4 regions of interest along the pharyngeal wall (superior oropharynx, inferior oropharynx, superior hypopharynx, and inferior hypopharynx). Case-control analysis was performed with a multivariate logistic regression model that included pretreatment and treatment potential factors. Results: A total of 154 patients were evaluable for this analysis, 71 cases (patients with severe late toxicities) and 83 controls; thus, 46% of evaluable patients had a severe late toxicity. On multivariate analysis, significant variables correlated with the development of severe late toxicity, including older age (odds ratio, 1.062 per year; P=.0021) and radiation dose received by the inferior hypopharynx (odds ratio, 1.023 per Gy; P=.016). The subgroup of patients receiving {<=}60 Gy to the inferior hypopharynx had a 40% rate of severe late toxicity compared with 56% for patients receiving >60 Gy. Oropharyngeal dose was not associated with this outcome. Conclusions: Severe late toxicity following CCRT is common in long-term survivors. Age is the most significant factor, but hypopharyngeal dose also was associated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reduction of 1/f noise in graphene after electron-beam irradiation

We investigated experimentally the effect of the electron-beam irradiation on the level of the low-frequency 1/f noise in graphene devices. It was found that 1/f noise in graphene reduces with increasing concentration of defects induced by irradiation. The increased amount of structural disorder in graphene under irradiation was verified with micro-Raman spectroscopy. The bombardment of graphene devices with 20-keV electrons reduced the noise spectral density, S{sub I}/I{sup 2} (I is the source-drain current) by an order-of magnitude at the radiation dose of 10{sup 4} {mu}C/cm{sup 2}. We analyzed the observed noise reduction in the limiting cases of the mobility and carrier number fluctuation mechanisms. The obtained results are important for the proposed graphene applications in analog, mixed-signal, and radio-frequency systems, integrated circuits and sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Duodenal Toxicity After Fractionated Chemoradiation for Unresectable Pancreatic Cancer

Purpose: Improving local control is critical to improving survival and quality of life for patients with locally advanced unresectable pancreatic cancer (LAPC). However, previous attempts at radiation dose escalation have been limited by duodenal toxicity. In order to guide future studies, we analyzed the clinical and dosimetric factors associated with duodenal toxicity in patients undergoing fractionated chemoradiation for LAPC. Methods and Materials: Medical records and treatment plans of 106 patients with LAPC who were treated with chemoradiation between July 2005 and June 2010 at our institution were reviewed. All patients received neoadjuvant and concurrent chemotherapy. Seventy-eight patients were treated with conventional radiation to 50.4 Gy in 28 fractions; 28 patients received dose-escalated radiation therapy (range, 57.5-75.4 Gy in 28-39 fractions). Treatment-related toxicity was graded according to Common Terminology Criteria for Adverse Events, version 4.0. Univariate and multivariate analyses were performed to assess prognostic influence of clinical, pathologic, and treatment-related factors by using Kaplan-Meier and Cox regression methods. Results: Twenty patients had treatment-related duodenal toxicity events, such as duodenal inflammation, ulceration, and bleeding. Four patients had grade 1 events, 8 had grade 2, 6 had grade 3, 1 had grade 4, and 1 had grade 5. On univariate analysis, a toxicity grade ≥2 was associated with tumor location, low platelet count, an absolute volume (cm{sup 3}) receiving a dose of at least 55 Gy (V{sub 55} {sub Gy} > 1 cm{sup 3}), and a maximum point dose >60 Gy. Of these factors, only V{sub 55} {sub Gy} ≥1 cm{sup 3} was associated with duodenal toxicity on multivariate analysis (hazard ratio, 6.7; range, 2.0-18.8; P=.002). Conclusions: This study demonstrates that a duodenal V{sub 55} {sub Gy} >1 cm{sup 3} is an important dosimetric predictor of grade 2 or greater duodenal toxicity and establishes it as a dosimetric constraint when treating patients with unresectable pancreatic cancer with concurrent chemoradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Celiac Node Failure Patterns After Definitive Chemoradiation for Esophageal Cancer in the Modern Era

Purpose: The celiac lymph node axis acts as a gateway for metastatic systemic spread. The need for prophylactic celiac nodal coverage in chemoradiation therapy for esophageal cancer is controversial. Given the improved ability to evaluate lymph node status before treatment via positron emission tomography (PET) and endoscopic ultrasound, we hypothesized that prophylactic celiac node irradiation may not be needed for patients with localized esophageal carcinoma. Methods and Materials: We reviewed the radiation treatment volumes for 131 patients who underwent definitive chemoradiation for esophageal cancer. Patients with celiac lymph node involvement at baseline were excluded. Median radiation dose was 50.4 Gy. The location of all celiac node failures was compared with the radiation treatment plan to determine whether the failures occurred within or outside the radiation treatment field. Results: At a median follow-up time of 52.6 months (95% CI 46.1-56.7 months), 6 of 60 patients (10%) without celiac node coverage had celiac nodal failure; in 5 of these patients, the failures represented the first site of recurrence. Of the 71 patients who had celiac coverage, only 5 patients (7%) had celiac region relapse. In multivariate analyses, having a pretreatment-to-post-treatment change in standardized uptake value on PET >52% (odds ratio [OR] 0.198, p = 0.0327) and having failure in the clinical target volume (OR 10.72, p = 0.001) were associated with risk of celiac region relapse. Of those without celiac coverage, the 6 patients that later developed celiac failure had a worse median overall survival time compared with the other 54 patients who did not fail (median overall survival time: 16.5 months vs. 31.5 months, p = 0.041). Acute and late toxicities were similar in both groups. Conclusions: Although celiac lymph node failures occur in approximately 1 of 10 patients, the lack of effective salvage treatments and subsequent low morbidity may justify prophylactic treatment in distal esophageal cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost-Effectiveness Analysis of Single Fraction of Stereotactic Body Radiation Therapy Compared With Single Fraction of External Beam Radiation Therapy for Palliation of Vertebral Bone Metastases

Purpose: Stereotactic body radiation therapy (SBRT) has been proposed for the palliation of painful vertebral bone metastases because higher radiation doses may result in superior and more durable pain control. A phase III clinical trial (Radiation Therapy Oncology Group 0631) comparing single fraction SBRT with single fraction external beam radiation therapy (EBRT) in palliative treatment of painful vertebral bone metastases is now ongoing. We performed a cost-effectiveness analysis to compare these strategies. Methods and Materials: A Markov model, using a 1-month cycle over a lifetime horizon, was developed to compare the cost-effectiveness of SBRT (16 or 18 Gy in 1 fraction) with that of 8 Gy in 1 fraction of EBRT. Transition probabilities, quality of life utilities, and costs associated with SBRT and EBRT were captured in the model. Costs were based on Medicare reimbursement in 2014. Strategies were compared using the incremental cost-effectiveness ratio (ICER), and effectiveness was measured in quality-adjusted life years (QALYs). To account for uncertainty, 1-way, 2-way and probabilistic sensitivity analyses were performed. Strategies were evaluated with a willingness-to-pay (WTP) threshold of $100,000 per QALY gained. Results: Base case pain relief after the treatment was assumed as 20% higher in SBRT. Base case treatment costs for SBRT and EBRT were $9000 and $1087, respectively. In the base case analysis, SBRT resulted in an ICER of $124,552 per QALY gained. In 1-way sensitivity analyses, results were most sensitive to variation of the utility of unrelieved pain; the utility of relieved pain after initial treatment and median survival were also sensitive to variation. If median survival is ≥11 months, SBRT cost <$100,000 per QALY gained. Conclusion: SBRT for palliation of vertebral bone metastases is not cost-effective compared with EBRT at a $100,000 per QALY gained WTP threshold. However, if median survival is ≥11 months, SBRT costs ≤$100,000 per QALY gained, suggesting that selective SBRT use in patients with longer expected survival may be the most cost-effective approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Control For High-Grade Nonrhabdomyosarcoma Soft Tissue Sarcoma Assigned to Radiation Therapy on ARST0332: A Report From the Childrens Oncology Group

The ARST0332 trial for pediatric and young adults with nonrhabdomyosarcoma soft tissue sarcoma (NRSTS) used risk-based treatment including primary resection with lower-than-standard radiation doses to optimize local control (LC) while minimizing long-term toxicity in those requiring radiation therapy (RT). RT for high-grade NRSTS was based on extent of resection (R0: negative margins, R1: microscopic margins, R2/U: gross disease/unresectable); those with >5 cm tumors received chemotherapy (CT; ifosfamide/doxorubicin). This analysis evaluates LC for patients assigned to RT and prognostic factors associated with local recurrence (LR).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On-Chip p-MOSFET Dosimetry

On-chip p-FETs were developed to monitor the radiation dose of n-well CMOS ICs by monitoring the threshold voltage shifts due to radiation induced oxide and interface charge.

FET's↗