Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Plug-and-Play Priors for Bright Field Electron Tomography and Sparse Interpolation

Many material and biological samples in scientific imaging are characterized by nonlocal repeating structures. These are studied using scanning electron microscopy and electron tomography. Sparse sampling of individual pixels in a two-dimensional image acquisition geometry, or sparse sampling of projection images with large tilt increments in a tomography experiment, can enable high speed data acquisition and minimize sample damage caused by the electron beam. In this paper, we present an algorithm for electron tomographic reconstruction and sparse image interpolation that exploits the nonlocal redundancy in images. We adapt a framework, termed plug-and-play priors, to solve these imaging problems in a regularized inversion setting. The power of the plug-and-play approach is that it allows a wide array of modern denoising algorithms to be used as a “prior model” for tomography and image interpolation. We also present sufficient mathematical conditions that ensure convergence of the plug-and-play approach, and we use these insights to design a new nonlocal means denoising algorithm. Finally, we demonstrate that the algorithm produces higher quality reconstructions on both simulated and real electron microscope data, along with improved convergence properties compared to other methods.

47 OTHER INSTRUMENTATION↗

SU-E-T-609: Evaluation of Transit Dosimetry Software Using Heterogeneous Phantom

Purpose: The purpose of this work was to evaluate limits and capabilities in the transit dosimetry software for use with the TomoTherapy system by irradiating a heterogeneous phantom. Methods: Helical TomoTherapy plan was created using CIRS phantom (model 062M) with nine various tissue equivalent inserts (lung inhale 0.2 g/cm{sup 3}, lung exhale 0.5 g/cm{sup 3}, adipose 0.96 g/cm{sup 3}, breast 0.99 g/cm{sup 3}, water 1.01 g/cm{sup 3}, muscle 1.06 g/cm{sup 3}, liver 1.07 g/cm{sup 3}, trabecular bone 1.16 g/cm{sup 3}, and dense bone 1.53 g/cm{sup 3}). Targets were contoured within every insert. The phantom was scanned with a 50 cm field of view and 3 mm slice width. Images were imported into the TomoTherapy TPS. A plan was generated to deliver 20 Gy to every insert (2 Gy per fraction) with a jaw width of 2.5 cm, a pitch of 0.430 and an actual modulation factor of 2.621. After the radiation delivery the planning CT, the RT structure, the RT plan, and the RT dose (DICOM format) as well as the exit detector sinogram were imported into the Dosimetry Check software (Math Resolutions, LLC). The 3D delivered doses were reconstructed from the exit detector data by correcting for phantom and couch attenuation. The resulting dose distribution were compared with the TPS planned dose using gamma index. Results: Using the clinical gamma criteria, 3% and 3 mm, all tissue equivalent inserts had a passing percentage of 100% except for 0.2 g/cm{sup 3} and 0.5 g/cm{sup 3} density inserts (gamma value of 81.67% and 99.18% respectively). Conclusion: The evaluated transit dosimetry software provides an independent verification of helical TomoTherapy plans giving additional confidence in the treatment delivery, however, an overestimation of the reconstructed dose in low density materials has been revealed. Implementation of Monte Carlo algorithm for exit dose reconstruction should improve dosimetric accuracy in heterogeneous patient tissues. Agreement with Math Resolutions.

60 APPLIED LIFE SCIENCES↗

SU-D-207-04: GPU-Based 4D Cone-Beam CT Reconstruction Using Adaptive Meshing Method

Purpose: Due to the limited number of projections at each phase, the image quality of a four-dimensional cone-beam CT (4D-CBCT) is often degraded, which decreases the accuracy of subsequent motion modeling. One of the promising methods is the simultaneous motion estimation and image reconstruction (SMEIR) approach. The objective of this work is to enhance the computational speed of the SMEIR algorithm using adaptive feature-based tetrahedral meshing and GPU-based parallelization. Methods: The first step is to generate the tetrahedral mesh based on the features of a reference phase 4D-CBCT, so that the deformation can be well captured and accurately diffused from the mesh vertices to voxels of the image volume. After the mesh generation, the updated motion model and other phases of 4D-CBCT can be obtained by matching the 4D-CBCT projection images at each phase with the corresponding forward projections of the deformed reference phase of 4D-CBCT. The entire process of this 4D-CBCT reconstruction method is implemented on GPU, resulting in significantly increasing the computational efficiency due to its tremendous parallel computing ability. Results: A 4D XCAT digital phantom was used to test the proposed mesh-based image reconstruction algorithm. The image Result shows both bone structures and inside of the lung are well-preserved and the tumor position can be well captured. Compared to the previous voxel-based CPU implementation of SMEIR, the proposed method is about 157 times faster for reconstructing a 10 -phase 4D-CBCT with dimension 256×256×150. Conclusion: The GPU-based parallel 4D CBCT reconstruction method uses the feature-based mesh for estimating motion model and demonstrates equivalent image Result with previous voxel-based SMEIR approach, with significantly improved computational speed.

60 APPLIED LIFE SCIENCES↗

Mu2e Calorimeter Clustering Studies [Slides]

aMu2e (muon-to-electron-conversion), an Intensity Frontier experiment at Fermilab set to begin data taking in 2022, will search for flavor violation in charged leptons with a muon decaying to only an electron without any neutrinos. Protons will be accelerated by the 8GeV proton beam before reaching Mu2e’s production target. From there, pions enter an S-shaped Transport Solenoid and travel through a series of absorbers and collimators to select low-energy negatively charged muons from pion decay that will hit the stopping target. Downstream from the stopping target are a curved straw tracker and two annular disk crystal calorimeters. The signal will be a mono-energetic e- with an energy close to the rest mass of a muon. The Mu2e expected single event sensitivity is 2.87e-17. The complimentary trigger strategy will take advantage of both online track searches from the tracker and calorimeter reconstruction. The trigger requires a rejection factor greater than 100 and m ust make its decision within a 3ms time budget. In order to provide high efficiency on signal events, our calorimeter clustering algorithms must be accurate and meet the timing performance. I will discuss the expected performance of two clustering algorithms: a fast algorithm to be used at the trigger level and a more accurate clustering algorithm to be used in the offline reconstruction. The fast algorithm defines clusters by only selecting crystals adjacent to a high energy crystal seed. The full-blown algorithm can find smaller clusters separated from the main cluster, within a distance and timing window, and combine them into one cluster. We have analyzed the topology of the reconstructed clusters by the two algorithms on events with only a conversion electron and combined signal and background events. The goal of these studies is to improve the performance of the fast algorithm to better reconstruct the cluster energy and work within the strict timing budget.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction from Uniformly Attenuated SPECT Projection Data Using the DBH Method

An algorithm was developed for the two-dimensional (2D) reconstruction of truncated and non-truncated uniformly attenuated data acquired from single photon emission computed tomography (SPECT). The algorithm is able to reconstruct data from half-scan (180o) and short-scan (180?+fan angle) acquisitions for parallel- and fan-beam geometries, respectively, as well as data from full-scan (360o) acquisitions. The algorithm is a derivative, backprojection, and Hilbert transform (DBH) method, which involves the backprojection of differentiated projection data followed by an inversion of the finite weighted Hilbert transform. The kernel of the inverse weighted Hilbert transform is solved numerically using matrix inversion. Numerical simulations confirm that the DBH method provides accurate reconstructions from half-scan and short-scan data, even when there is truncation. However, as the attenuation increases, finer data sampling is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporal X-ray Reconstruction using Temporal and Spectral Measurements at LCLS

Transverse deflecting structures (TDSs) are widely used in accelerator physics to measure the longitudinal density of particle bunches. When used in combination with a dispersive section, the whole longitudinal phase space density can be imaged. At the Linac Coherent Light Source (LCLS), the installation of such a device downstream of the undulators enables the reconstruction of the X-ray temporal intensity profile by comparing longitudinal phase space distributions with lasing on and lasing off. However, the resolution of this TDS is limited to around 1 fs rms (root mean square), and therefore, it is not possible to resolve single self-amplified spontaneous emission (SASE) spikes within an X-ray photon pulse. By combining the power spectrum from a high resolution photon spectrometer and the temporal structure from the TDS, the overall resolution is enhanced, thus allowing the observation of temporal, single SASE spikes. The combined data from the spectrometer and the TDS is analysed using an iterative algorithm to obtain the actual intensity profile. In this paper, we present some improvements to the reconstruction algorithm as well as real data taken at LCLS.

47 OTHER INSTRUMENTATION↗

SU-F-SPS-06: Implementation of a Back-Projection Algorithm for 2D in Vivo Dosimetry with An EPID System

Purpose: To implement a back-projection algorithm for 2D dose reconstructions for in vivo dosimetry in radiation therapy using an Electronic Portal Imaging Device (EPID) based on amorphous silicon. Methods: An EPID system was used to calculate dose-response function, pixel sensitivity map, exponential scatter kernels and beam hardenig correction for the back-projection algorithm. All measurements were done with a 6 MV beam. A 2D dose reconstruction for an irradiated water phantom (30×30×30 cm{sup 3}) was done to verify the algorithm implementation. Gamma index evaluation between the 2D reconstructed dose and the calculated with a treatment planning system (TPS) was done. Results: A linear fit was found for the dose-response function. The pixel sensitivity map has a radial symmetry and was calculated with a profile of the pixel sensitivity variation. The parameters for the scatter kernels were determined only for a 6 MV beam. The primary dose was estimated applying the scatter kernel within EPID and scatter kernel within the patient. The beam hardening coefficient is σBH= 3.788×10{sup −4} cm{sup 2} and the effective linear attenuation coefficient is µAC= 0.06084 cm{sup −1}. The 95% of points evaluated had γ values not longer than the unity, with gamma criteria of ΔD = 3% and Δd = 3 mm, and within the 50% isodose surface. Conclusion: The use of EPID systems proved to be a fast tool for in vivo dosimetry, but the implementation is more complex that the elaborated for pre-treatment dose verification, therefore, a simplest method must be investigated. The accuracy of this method should be improved modifying the algorithm in order to compare lower isodose curves.

60 APPLIED LIFE SCIENCES↗

Automated selection of the optimal cardiac phase for single-beat coronary CT angiography reconstruction

Purpose: Reconstructing a low-motion cardiac phase is expected to improve coronary artery visualization in coronary computed tomography angiography (CCTA) exams. This study developed an automated algorithm for selecting the optimal cardiac phase for CCTA reconstruction. The algorithm uses prospectively gated, single-beat, multiphase data made possible by wide cone-beam imaging. The proposed algorithm differs from previous approaches because the optimal phase is identified based on vessel image quality (IQ) directly, compared to previous approaches that included motion estimation and interphase processing. Because there is no processing of interphase information, the algorithm can be applied to any sampling of image phases, making it suited for prospectively gated studies where only a subset of phases are available. Methods: An automated algorithm was developed to select the optimal phase based on quantitative IQ metrics. For each reconstructed slice at each reconstructed phase, an image quality metric was calculated based on measures of circularity and edge strength of through-plane vessels. The image quality metric was aggregated across slices, while a metric of vessel-location consistency was used to ignore slices that did not contain through-plane vessels. The algorithm performance was evaluated using two observer studies. Fourteen single-beat cardiac CT exams (Revolution CT, GE Healthcare, Chalfont St. Giles, UK) reconstructed at 2% intervals were evaluated for best systolic (1), diastolic (6), or systolic and diastolic phases (7) by three readers and the algorithm. Pairwise inter-reader and reader-algorithm agreement was evaluated using the mean absolute difference (MAD) and concordance correlation coefficient (CCC) between the reader and algorithm-selected phases. A reader-consensus best phase was determined and compared to the algorithm selected phase. In cases where the algorithm and consensus best phases differed by more than 2%, IQ was scored by three readers using a five point Likert scale. Results: There was no statistically significant difference between inter-reader and reader-algorithm agreement for either MAD or CCC metrics (p > 0.1). The algorithm phase was within 2% of the consensus phase in 15/21 of cases. The average absolute difference between consensus and algorithm best phases was 2.29% ± 2.47%, with a maximum difference of 8%. Average image quality scores for the algorithm chosen best phase were 4.01 ± 0.65 overall, 3.33 ± 1.27 for right coronary artery (RCA), 4.50 ± 0.35 for left anterior descending (LAD) artery, and 4.50 ± 0.35 for left circumflex artery (LCX). Average image quality scores for the consensus best phase were 4.11 ± 0.54 overall, 3.44 ± 1.03 for RCA, 4.39 ± 0.39 for LAD, and 4.50 ± 0.18 for LCX. There was no statistically significant difference (p > 0.1) between the image quality scores of the algorithm phase and the consensus phase. Conclusions: The proposed algorithm was statistically equivalent to a reader in selecting an optimal cardiac phase for CCTA exams. When reader and algorithm phases differed by >2%, image quality as rated by blinded readers was statistically equivalent. By detecting the optimal phase for CCTA reconstruction, the proposed algorithm is expected to improve coronary artery visualization in CCTA exams.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improving reproducibility in synchrotron tomography using implementation-adapted filters

For reconstructing large tomographic datasets fast, filtered backprojection-type or Fourier-based algorithms are still the method of choice, as they have been for decades. These robust and computationally efficient algorithms have been integrated in a broad range of software packages. The continuous mathematical formulas used for image reconstruction in such algorithms are unambiguous. However, variations in discretization and interpolation result in quantitative differences between reconstructed images, and corresponding segmentations, obtained from different software. This hinders reproducibility of experimental results, making it difficult to ensure that results and conclusions from experiments can be reproduced at different facilities or using different software. In this paper, a way to reduce such differences by optimizing the filter used in analytical algorithms is proposed. These filters can be computed using a wrapper routine around a black-box implementation of a reconstruction algorithm, and lead to quantitatively similar reconstructions. Use cases for this approach are demonstrated by computing implementation-adapted filters for several open-source implementations and applying them to simulated phantoms and real-world data acquired at the synchrotron. Our contribution to a reproducible reconstruction step forms a building block towards a fully reproducible synchrotron tomography data processing pipeline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray nano-holotomography reconstruction with simultaneous probe retrieval

In conventional tomographic reconstruction, the pre-processing step includes flat-field correction, where each sample projection on the detector is divided by a reference image taken without the sample. When using coherent X-rays as a probe, this approach overlooks the phase component of the illumination field (probe), leading to artifacts in phase-retrieved projection images, which are then propagated to the reconstructed 3D sample representation. The problem intensifies in nano-holotomography with focusing optics, which, due to various imperfections creates high-frequency components in the probe function. Here, we present a new iterative reconstruction scheme for holotomography, simultaneously retrieving the complex-valued probe function. Implemented on GPUs, this algorithm results in 3D reconstruction resolving twice thinner layers in a 3D ALD standard sample measured using nano-holotomography.

Nikitin, Viktor↗

Image reconstruction from sparse data ion synchrotron-radiation-based micro-tomography.

Synchrotron-radiation-based microcomputed-tomography (SR-{micro}CT) is a powerful tool for yielding 3D structural information of high spatial and contrast resolution about a specimen preserved in its natural state. A large number of projection views are required currently for yielding SR-{micro}CT images by use of existing algorithms without significant artifacts. When a wet biological specimen is imaged, synchrotron x-ray radiation from a large number of projection views can result in significant structural deformation within the specimen. A possible approach to reducing imaging time and specimen deformation is to decrease the number of projection views. In the work, using reconstruction algorithms developed recently for medical computed tomography (CT), we investigate and demonstrate image reconstruction from sparse-view data acquired in SR-{micro}CT. Numerical results of our study suggest that images of practical value can be obtained from data acquired at a number of projection views significantly lower than those used currently in a typical SR-{micro}CT imaging experiment.

99 GENERAL AND MISCELLANEOUS↗

Calorimetry with deep learning: particle simulation and reconstruction for collider physics

Using detailed simulations of calorimeter showers as training data, we investigate the use of deep learning algorithms for the simulation and reconstruction of single isolated particles produced in high-energy physics collisions. We train neural networks on single-particle shower data at the calorimeter-cell level, and show significant improvements for simulation and reconstruction when using these networks compared to methods which rely on currently-used state-of-the-art algorithms. We define two models: an end-to-end reconstruction network which performs simultaneous particle identification and energy regression of particles when given calorimeter shower data, and a generative network which can provide reasonable modeling of calorimeter showers for different particle types at specified angles and energies. We investigate the optimization of our models with hyperparameter scans. Furthermore, we demonstrate the applicability of the reconstruction model to shower inputs from other detector geometries, specifically ATLAS-like and CMS-like geometries. These networks can serve as fast and computationally light methods for particle shower simulation and reconstruction for current and future experiments at particle colliders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-Phase Solid Oxide Fuel Cell Anode Microstructure Realization Using Two-Point Correlation Functions

A Monte Carlo methodology is developed as a means for three-dimensional (3D) reconstruction of the microstructure of a three-phase anode used in solid oxide fuel cells, based on two-point statistical functions. The salient feature of the presented reconstruction methodology is the ability to realize the 3D microstructure from its 2D SEM image for a three-phase medium extendable to n-phase media. In the realization procedure, different phases of the heterogeneous medium are represented by different cells which are allowed to grow. The growth of cells, however, are controlled via several optimization parameters related to rotation, shrinkage, translation, distribution and growth rates of the cells. Indeed, the proposed realization algorithm can be categorized as a member of dynamic programming methods and is designed so comprehensive that can realize any desired microstructure. To be more specific, at first the initial 2D image is successfully reconstructed and then the final optimization parameters are used as the initial values for the initiation of the 3D reconstruction algorithm. This paper presents a novel hybrid stochastic methodology based on the colony and kinetic algorithm for the simulation of the virtual microstructure. The simulation procedure involves repeated realizations where each realization in turn consists of nucleation and growth of cells. For each of the subsequent realizations, the controlling parameters get updated by minimization of an objective function at the end of the preceding realization. Here, the objective function is defined based on the two-point correlation functions from the simulated and real microstructures. The kinetic growth algorithm is established on the cellular automata approach which facilitates the simulation procedure. Comparison of the two-point correlation functions from different sections of the final 3D reconstructed microstructure with the initial real microstructure shows a satisfactory agreement which confirms the proposed methodology.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identification of hadronic tau lepton decays using a deep neural network

A new algorithm is presented to discriminate reconstructed hadronic decays of tau leptons ($\tau_\mathrm{h}$) that originate from genuine tau leptons in the CMS detector against $\tau_\mathrm{h}$ candidates that originate from quark or gluon jets, electrons, or muons. The algorithm inputs information from all reconstructed particles in the vicinity of a $\tau_\mathrm{h}$ candidate and employs a deep neural network with convolutional layers to efficiently process the inputs. This algorithm leads to a significantly improved performance compared with the previously used one. For example, the efficiency for a genuine $\tau_\mathrm{h}$ to pass the discriminator against jets increases by 10-30% for a given efficiency for quark and gluon jets. Furthermore, a more efficient $\tau_\mathrm{h}$ reconstruction is introduced that incorporates additional hadronic decay modes. The superior performance of the new algorithm to discriminate against jets, electrons, and muons and the improved $\tau_\mathrm{h}$ reconstruction method are validated with LHC proton-proton collision data at $\sqrt{s} =$ 13 TeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of reconstruction-free static magnetic control of DIII-D plasma with deep reinforcement learning

This paper presents the development and experimental validation of a reinforcement learning (RL)-based magnetic controller on the DIII-D tokamak. The controller directly maps raw magnetic diagnostic signals to actuator commands, replacing the traditional isoflux control algorithm based on equilibrium reconstruction. Four RL controllers are trained using the Soft Actor–Critic algorithm with an asymmetric Actor–Critic architecture in the NSFsim simulator. All controllers are deployed in the DIII-D Plasma Control System and operated with a 4 kHz feedback loop. Two randomization strategies are evaluated during training: evolving kinetic profiles and fixed kinetic profiles within each episode. The latter approach is found to better capture experimental deviations in the current density profile and to provide overall improved control performance. Robust operation is demonstrated across heating power scans in both L- and H-mode plasmas, as well as during transient events such as L–H transitions and pellet injections. Control errors in plasma shape and radial position remained within 1.5–2.0 cm and 1 cm, respectively. A notable discrepancy was observed in the vertical X-point position, with errors of up to approximately 4 cm, attributed to the current density distribution mismatches between simulations and experiments.

DIII-D↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗

Spacetime encodings. I. A spacetime reconstruction problem

This paper explores features of an idealized mathematical machine (algorithm) that would be capable of reconstructing the gravitational nature (the multipolar structure or spacetime metric) of a compact object, by observing gravitational radiation emitted by a small object that orbits and spirals into it. An outline is given of the mathematical developments that must be carried out in order to construct such a machine.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗