Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Moderator design studies for a new neutron reference source based on the $\mathrm{D}$–$\mathrm{T}$ fusion reaction

The radioactive isotope Californium-252 ( 252 Cf) is relied upon internationally as a neutron calibration source for ionizing radiation dosimetry because of its high specific activity. The source may be placed within a heavy-water (D 2 O) moderating sphere to produce a softened spectrum representative of neutron fields common to commercial nuclear power plant environments, among others. Due to termination of the U.S. Department of Energy loan/lease program in 2012, the expense of obtaining 252 Cf sources has undergone a significant increase, rendering high output sources largely unattainable. On the other hand, the use of neutron generators in research and industry applications has increased dramatically in recent years. Neutron generators based on deuterium-tritium (D-T) fusion reaction provide high neutron fluence rates and, therefore, could possibly be used as a replacement for 252 Cf. To be viable, the 14.6 MeV D-T output spectrum must be significantly moderated to approximate common workplace environments. Here this paper presents the results of an effort to select appropriate moderating materials and design a configuration to reshape the primary neutron field toward a spectrum approaching that from a nuclear power plant workplace. A series of Monte-Carlo (MCNP) simulations of single layer high- and low-Z materials are used to identify initial candidate moderators. Candidates are refined through a similar series of simulations involving combinations of 2 to 5 different materials. The simulated energy distribution using these candidate moderators are rated in comparison to a target spectrum. Other properties, such as fluence preservation and/or enhancement, prompt gamma production and other characteristics are also considered.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Performance and wake flow characterization of a 1:8.7-scale reference USDOE MHKF1 hydrokinetic turbine to establish a verification and validation test database

As hydrokinetic turbine technologies continue to advance towards commercialization, public datasets on the performance characteristics for these devices and their flow field effects are invaluable to advance our understanding of these technologies and to validate analytical and numerical models. The Applied Research Laboratory at The Pennsylvania State University (ARL Penn State) collaborated with Sandia National Laboratories and the University of California at Davis to design, fabricate (at a 1:8.7 scale), and experimentally test a novel hydrokinetic turbine rotor design to provide an open platform and dataset for further study and development. The water tunnel test of this three-bladed, horizontal-axis rotor recorded power production, blade loading, the near-wake flow, cavitation effects, and noise generation. These state-of-the-art measurements demonstrate much of the complex physics associated with the flow through an unducted, horizontal-axis turbine, and they elucidate the performance characteristics and flow field effects at an unprecedented fidelity, accuracy and resolution. Measurements of powering coefficients (power, torque and thrust) as a function of tip-speed-ratio were performed. The dataset also includes unsteady measurements of driveshaft loading, blade strain, tower pressures, and radiated noise. Detailed flow mapping using laser Doppler velocimetry, and planar and stereo particle image velocimetry includes measurements of mean velocity and Reynolds stresses. Although the wake measurements are limited to less than half a diameter, they reveal the complex flow patterns in the near-wake structure of the rotor. The full database, available at the United States Department of Energy’s marine and hydrokinetic data repository, includes tunnel and model Computer Aided Design geometry files and inflow data sufficient for a “Model-the-Test” computational Verification and Validation study.

13 HYDRO ENERGY↗

Expanding the genomic encyclopedia of Actinobacteria with 824 isolate reference genomes

The phylum Actinobacteria includes important human pathogens like Mycobacterium tuberculosis and Corynebacterium diphtheriae and renowned producers of secondary metabolites of commercial interest, yet only a small part of its diversity is represented by sequenced genomes. Here, we present 824 actinobacterial isolate genomes in the context of a phylum-wide analysis of 6,700 genomes including public isolates and metagenome-assembled genomes (MAGs). We estimate that only 30%–50% of projected actinobacterial phylogenetic diversity possesses genomic representation via isolates and MAGs. A comparison of gene functions reveals novel determinants of host-microbe interaction as well as environment-specific adaptations such as potential antimicrobial peptides. We identify plasmids and prophages across isolates and uncover extensive prophage diversity structured mainly by host taxonomy. Analysis of >80,000 biosynthetic gene clusters reveals that horizontal gene transfer and gene loss shape secondary metabolite repertoire across taxa. Our observations illustrate the essential role of and need for high-quality isolate genome sequences.

59 BASIC BIOLOGICAL SCIENCES↗

KETCHUP: Parameterizing of large-scale kinetic models using multiple datasets with different reference states

Large-scale kinetic models provide the computational means to dynamically link metabolic reaction fluxes to metabolite concentrations and enzyme levels while also conforming to substrate level regulation. However, the development of broadly applicable frameworks for efficiently and robustly parameterizing models remains a challenge. Challenges arise due to both the heterogeneity, paucity, and difficulty in obtaining flux and/or concentration data but also due to the computational difficulties of the underlying parameter identification problem. Both the computational demands for parameterization, degeneracy of obtained parameter solutions and interpretability of results has so far limited widespread adoption of large-scale kinetic models despite their potential. Herein, we introduce the Kinetic Estimation Tool Capturing Heterogeneous Datasets Using Pyomo (KETCHUP), a flexible parameter estimation tool that leverages a primal-dual interior-point algorithm to solve a nonlinear programming (NLP) problem that identifies a set of parameters capable of recapitulating the (non)steady-state fluxes and concentrations in wild-type and perturbed metabolic networks. KETCHUP is benchmarked against previously parameterized large-scale kinetic models demonstrating an at least an order of magnitude faster convergence than the tool K-FIT while at the same time attaining better data fits. Finally, this versatile toolbox accepts different kinetic descriptions, metabolic fluxes, enzyme levels and metabolite concentrations, under either steady-state or instationary conditions to enable robust kinetic model construction and parameterization. KETCHUP supports the SBML format and can be accessed at https://github.com/maranasgroup/KETCHUP.

59 BASIC BIOLOGICAL SCIENCES↗

Synthesis of cerium oxide (CeO 2 ) by co-precipitation for application as a reference material for X-ray powder diffraction peak widths

Several methods can be used to obtain, from powder diffraction patterns, crystallite size and lattice strain of polycrystalline samples. Some examples are the Scherrer equation, Williamson–Hall plots, Warren/Averbach Fourier decomposition, Whole Powder Pattern Modeling, and Debye function analysis. To apply some of these methods, it is necessary to remove the contribution of the instrument to the widths of the diffraction peaks. Nowadays, one of the main samples used for this purpose is the LaB6 SRM660b commercialized by the National Institute of Standard Technology; the width of the diffraction peak of this sample is caused only by the instrumental apparatus. However, this sample can be expensive for researchers in developing countries. In this work, the authors present a simple route to obtain micron-sized polycrystalline CeO 2 that have a full width at half maximum comparable with the SRM660b and therefore it can be used to remove instrumental broadening.

de Lima Batista, Anderson Márcio↗