Search NASA⌕ Search

SEARCH · Search NASA

Results for “Response Spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Collective cavity quantum electrodynamics with multiple atomic levels

We study the transmission spectra of ultracold rubidium atoms coupled to a high-finesse optical cavity. Under weak probing with {pi}-polarized light, the linear response of the system is that of a collective spin with multiple levels coupled to a single mode of the cavity. By varying the atom number, we change the collective coupling of the system. We observe the change in transmission spectra when going from a regime where the collective coupling is much smaller than the separation of the atomic levels to a regime where both are of comparable size. The observations are in good agreement with a reduced model we developed for our system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved spectral data unfolding for radiochromic film imaging spectroscopy of laser-accelerated proton beams

An improved method to unfold the space-resolved proton energy distribution function of laser-accelerated proton beams using a layered, radiochromic film (RCF) detector stack has been developed. The method takes into account the reduced RCF response near the Bragg peak due to a high linear energy transfer (LET). This LET dependence of the active RCF layer has been measured, and published data have been re-interpreted to find a nonlinear saturation scaling of the RCF response with stopping power. Accounting for the LET effect increased the integrated particle yield by 25% after data unfolding. An iterative, analytical, space-resolved deconvolution of the RCF response functions from the measured dose was developed that does not rely on fitting. After the particle number unfold, three-dimensional interpolation is performed to determine the spatial proton beam distribution for proton energies in-between the RCF data points. Here, image morphing has been implemented as a novel interpolation method that takes into account the energy-dependent, changing beam topology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-607: Performance Quantification of the Nine Detectors Used for Dosimetry Measurements in Advanced Radiation Therapy Treatments

Purpose: The purpose of this study was to quantify performance of the nine detectors used for dosimetry measurements in advanced radiation therapy treatments. Methods: The 6 MV beam was utilized for measurements of the field sizes with the lack of lateral charge particle equilibrium. For dose fidelity aspect, energy dependence was studied by measuring PDD and profiles at different depths. The volume effect and its influence on the measured dose profiles have been observed by measuring detector’s response function. Output factor measurements with respect to change in energy spectrum have been performed and collected data has been analyzed. The linearity of the measurements with the dose delivered has been evaluated and relevant comparisons were done. Results: The measured values of the output factors with respect to change in energy spectrum indicated presence of the energy dependence. The detectors with active volume size ≤ 0.3 mm3 maximum deviation from the mean is 5.6% for the field size 0.5 x 0.5 cm2 while detectors with active volume size > 0.3 mm3 have maximum deviation from the mean 7.1%. Linearity with dose at highest dose rate examined for diode detectors showed maximum deviation of 4% while ion chambers showed maximum deviation of 2.2%. Dose profiles showed energy dependence at shallow depths (surface to dmax) influenced by low energy particles with 12 % maximum deviation from the mean for 5 mm2 field size. In relation to Monte Carlo calculation, the detector’s response function σ values were between (0.42±0.25) mm and (1.2±0.25) mm. Conclusion: All the detectors are appropriate for the dosimetry measurements in advanced radiation therapy treatments. The choice of the detectors has to be determined by the application and the scope of the measurements in respect to energy dependence and ability to accurately resolve dose profiles as well as to it’s intrinsic characteristics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Calculations from Source Models and Gamma-Ray Spectra

Gamma-ray dose rates computed by two radiation source model-based methods and five measured spectrum-based methods are compared. With the exception of a Detective DX-100, which reported dose rates that are about 25% less than the mean, dose rates are generally within 10% of mean values. Methods for computation of dose rates employed by the Gamma Detector Response and Analysis Software (GADRAS) are described and critically evaluated. Results are presented for a feasibility evaluation that seeks to use spectra recorded inside vehicles to estimate the minimum dose outside the vehicles.

61 RADIATION PROTECTION AND DOSIMETRY↗

Permanent-magnet energy spectrometer for electron beams from radiotherapy accelerators

Purpose: The purpose of this work was to adapt a lightweight, permanent magnet electron energy spectrometer for the measurement of energy spectra of therapeutic electron beams. Methods: An irradiation geometry and measurement technique were developed for an approximately 0.54-T, permanent dipole magnet spectrometer to produce suitable latent images on computed radiography (CR) phosphor strips. Dual-pinhole electron collimators created a 0.318-cm diameter, approximately parallel beam incident on the spectrometer and an appropriate dose rate at the image plane (CR strip location). X-ray background in the latent image, reduced by a 7.62-cm thick lead block between the pinhole collimators, was removed using a fitting technique. Theoretical energy-dependent detector response functions (DRFs) were used in an iterative technique to transform CR strip net mean dose profiles into energy spectra on central axis at the entrance to the spectrometer. These spectra were transformed to spectra at 95-cm source to collimator distance (SCD) by correcting for the energy dependence of electron scatter. The spectrometer was calibrated by comparing peak mean positions in the net mean dose profiles, initially to peak mean energies determined from the practical range of central-axis percent depth-dose (%DD) curves, and then to peak mean energies that accounted for how the collimation modified the energy spectra (recalibration). The utility of the spectrometer was demonstrated by measuring the energy spectra for the seven electron beams (7–20 MeV) of an Elekta Infinity radiotherapy accelerator. Results: Plots of DRF illustrated their dependence on energy and position in the imaging plane. Approximately 15 iterations solved for the energy spectra at the spectrometer entrance from the measured net mean dose profiles. Transforming those spectra into ones at 95-cm SCD increased the low energy tail of the spectra, while correspondingly decreasing the peaks and shifting them to slightly lower energies. Energy calibration plots of peak mean energy versus peak mean position of the net mean dose profiles for each of the seven electron beams followed the shape predicted by the Lorentz force law for a uniform z-component of the magnetic field, validating its being modeled as uniform (0.542 ± 0.027 T). Measured Elekta energy spectra and their peak mean energies correlated with the 0.5-cm (7–13 MeV) and the 1.0-cm (13–20 MeV) R{sub 90} spacings of the %DD curves. The full-width-half-maximum of the energy spectra decreased with decreasing peak mean energy with the exception of the 9-MeV beam, which was anomalously wide. Similarly, R{sub 80–20} decreased linearly with peak mean energy with the exception of the 9 MeV beam. Both were attributed to suboptimal tuning of the high power phase shifter for the recycled radiofrequency power reentering the traveling wave accelerator. Conclusions: The apparatus and analysis techniques of the authors demonstrated that an inexpensive, lightweight, permanent magnet electron energy spectrometer can be used for measuring the electron energy distributions of therapeutic electron beams (6–20 MeV). The primary goal of future work is to develop a real-time spectrometer by incorporating a real-time imager, which has potential applications such as beam matching, ongoing beam tune maintenance, and measuring spectra for input into Monte Carlo beam calculations.

60 APPLIED LIFE SCIENCES↗

Empirical Refinement of the GADRAS Detector Response Function

The Gamma Detector Response and Analysis Software (GADRAS) was augmented to enable empirical refinement of the Detector Response Function (DRF) for gamma-ray detectors. This capability is included in GADRAS starting with Version 18.8.2, which was released in February 2019 Empirical refinement enables improved computational accuracy for gamma-ray spectra when detectors exhibit characteristics that are essentially unique to a particular sensor. This report discusses how to perform the empirical refinement, and examples are presented for the following scenarios where empirical refinement is appropriate: Large plastic scintillators, which are generally composed of polyvinyl toluene (PVT), often exhibit low-energy peaks that are not associated with incident gamma rays. Regardless of whether they are artifacts produced by poor light collection or pulse processing methods, accurate spectral synthesis requires replication of these features; Some detectors, particularly those using Silicon Photomultipliers (SiPM), exhibit energy shifts of Compton edges and escape peaks relative to the same scintillator material attached to a photomultiplier tube. Empirical refinement compensates for these effects, which derive from nonlinearities in the detector response; The change in the DRF as a function of displacement of the source relative to the detector axis cannot always be replicated adequately using only the few shielding parameters that are used by the response function. Empirical refinement enables improved accuracy for computation of spectra during linear transits or when the detector is close to a large radiation source. This is a particularly important consideration for collimated detectors; and, Gamma-ray imagers exhibit complex relationships between spectral response and spatial locations. Empirical refinement enables substantial improvement of the DRF accuracy for imagers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar response of the BATSE instrument on the gamma-ray observatory

The Burst and Transient Source Experiment (BATSE) on board the gamma ray observatory (GRO) aims at comprehensive observations of time profiles, spectra, and locations of high-energy transient sources. The mysterious cosmic gamma ray bursts provided the main motivation for the observations, but BATSE will make excellent observations of many classes of sources, and in particular solar flares. The solar response of BATSE, as inferred from its design parameters, is analyzed for two purposes: the optimization of the solar observations themselves, and the characterization of the solar effects on ordinary nonsolar observations.

Fishman, G. J.↗

Quantitative comparison of noise texture across CT scanners from different manufacturers

Purpose: To quantitatively compare noise texture across computed tomography (CT) scanners from different manufacturers using the noise power spectrum (NPS). Methods: The American College of Radiology CT accreditation phantom (Gammex 464, Gammex, Inc., Middleton, WI) was imaged on two scanners: Discovery CT 750HD (GE Healthcare, Waukesha, WI), and SOMATOM Definition Flash (Siemens Healthcare, Germany), using a consistent acquisition protocol (120 kVp, 0.625/0.6 mm slice thickness, 250 mAs, and 22 cm field of view). Images were reconstructed using filtered backprojection and a wide selection of reconstruction kernels. For each image set, the 2D NPS were estimated from the uniform section of the phantom. The 2D spectra were normalized by their integral value, radially averaged, and filtered by the human visual response function. A systematic kernel-by-kernel comparison across manufacturers was performed by computing the root mean square difference (RMSD) and the peak frequency difference (PFD) between the NPS from different kernels. GE and Siemens kernels were compared and kernel pairs that minimized the RMSD and |PFD| were identified. Results: The RMSD (|PFD|) values between the NPS of GE and Siemens kernels varied from 0.01 mm{sup 2} (0.002 mm{sup -1}) to 0.29 mm{sup 2} (0.74 mm{sup -1}). The GE kernels 'Soft,''Standard,''Chest,' and 'Lung' closely matched the Siemens kernels 'B35f,''B43f,''B41f,' and 'B80f' (RMSD < 0.05 mm{sup 2}, |PFD| < 0.02 mm{sup -1}, respectively). The GE 'Bone,''Bone+,' and 'Edge' kernels all matched most closely with Siemens 'B75f' kernel but with sizeable RMSD and |PFD| values up to 0.18 mm{sup 2} and 0.41 mm{sup -1}, respectively. These sizeable RMSD and |PFD| values corresponded to visually perceivable differences in the noise texture of the images. Conclusions: It is possible to use the NPS to quantitatively compare noise texture across CT systems. The degree to which similar texture across scanners could be achieved varies and is limited by the kernels available on each scanner.

60 APPLIED LIFE SCIENCES↗

Synthesis, crystal structures and properties of lead phosphite compounds

Here, we report the preparation and characterization of two lead(II) phosphites, namely, Pb{sub 2}(HPO{sub 3}){sub 2} and Pb{sub 2}(HPO{sub 3})(NO{sub 3}){sub 2} through hydrothermal reaction or simple solution synthesis, respectively. A new lead phosphite, namely, Pb{sub 2}(HPO{sub 3}){sub 2}, crystallizes in the noncentrosymmetric space group Cmc2{sub 1} (no. 36), which features 3D framework formed by the interconnection of 2D layer of lead(II) phosphites and 1D chain of [Pb(HPO{sub 3}){sub 5}]{sub ∞}. The nonlinear optical properties of Pb{sub 2}(HPO{sub 3})(NO{sub 3}){sub 2} have been studied for the first time. The synergistic effect of the stereo-active lone-pairs on Pb{sup 2+} cations and π-conjugated NO{sub 3} units in Pb{sub 2}(HPO{sub 3})(NO{sub 3}){sub 2} produces a moderate second harmonic generation (SHG) response of ∼1.8×KDP (KH{sub 2}PO{sub 4}), which is phase matchable (type I). IR, UV–vis spectra and thermogravimetric analysis (TGA) for the two compounds were also measured. - Graphical abstract: Two lead phosphites Pb{sub 2}(HPO{sub 3}){sub 2} and Pb{sub 2}(HPO{sub 3})(NO{sub 3}){sub 2} are studied. A new lead phosphite Pb{sub 2}(HPO{sub 3}){sub 2} features a unique 3D framework structure and Pb{sub 2}(HPO{sub 3})(NO{sub 3}){sub 2} shows a moderate SHG response of ∼1.8×KDP (KH{sub 2}PO{sub 4}). - Highlights: • A new lead phosphite, Pb{sub 2}(HPO{sub 3}){sub 2} is reported. • Pb{sub 2}(HPO{sub 3}){sub 2} features a unique 3D framework structure. • NLO property of Pb{sub 2}(HPO{sub 3})(NO{sub 3}){sub 2} is investigated. • Pb{sub 2}(HPO{sub 3})(NO{sub 3}){sub 2} produces a moderate SHG response of ∼1.8×KDP (KH{sub 2}PO{sub 4}).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hibonite: Crystal Chemistry and Origin of Blue Coloration in Meteoritic Assemblages

The blue color and optical spectra of hibonite, a common constituent of refractory inclusions in carbonaceous chondrites, are discussed. Because they may be manifestations of exotic cation species stabilized in unusual coordination sites in the hibonite crystalstructure. Hibonite, ideally CaAl12O19, is conducive to atomic substitution of host Ca2+ and Al3+ ions by a variety of lanthanide and first series transition elements. The latter cations are responsible for the colors of many rock-forming minerals as a result of intraelectronic or intervalence transitions. The visible-region spectra of most oxide and silicate minerals are generally well understood. Assignments of absorption bands in meteoritic hibonite optical spectra due to uncertainties of cation valencies and complexities in the crystal structure are examined. The crystal chemistry of hibonite is reviewed, Mossbauer spectral measurements of iron-bearing hibonite and electronic transitions that may be responsible for the blue coloration of meteoritic hibonites are discussed.

Burns, R. G.↗

Molecular-level origin of the carboxylate head group response to divalent metal ion complexation at the air-water interface

We exploit gas-phase cluster ion techniques to provide insight into the local interactions underlying divalent metal ion-driven changes in the spectra of carboxylic acids at the air-water interface. This information is used to clarify the experimental findings of surface sensitive spectroscopies that the CO stretching bands of long chain acids appear at very similar energies when the head group is deprotonated by high sub-phase pH or is exposed to relatively high concentrations of Ca2+ divalent metal ions (e.g., Ca2+ and Mg2+). To this end, we report the evolution of the vibrational spectra of size-selected [Ca2+·RCO2¯]+·(H2O)n=0-14 and RCO2¯·(H2O)n=0-14 cluster ions obtained using infrared photofragmentation mass spectrometry toward the features observed at the air-water interface. The carboxylate with R = -CD2CD3 was chosen in order to capture the longer chain behavior and to suppress band congestion that complicates the spectra of the light isotopologue. Surprisingly, not only does stepwise hydration of the RCO2¯ anion and the [Ca2+·RCO2¯]+ contact ion pair yield solvatochromic responses in opposite directions, but in both cases the responses of the two CO bands (?_s^COO and ?_as^COO) to hydration are opposite to each other! The result is that the two CO bands evolve toward their interfacial and bulk asymptotes from opposite directions. Theoretical simulations of the [Ca2+·RCO2¯]+·(H2O)n clusters indicate that the metal ion remains directly bound to the head group in a contact ion pair motif as the asymmetric CO stretch converges at the bulk value by n = 12, establishing that direct metal complexation can account for the interfacial and bulk behavior. We discuss these effects in the context of a qualitative model that invokes the water network-dependent local electric field along the C-C bond connecting the head group to the tail as the key parameter driving the observed trends. M.A.J. and H.C.A. thank the National Science Foundation through the NSF Center for Aerosol Impacts on Chemistry of the Environment (NSF-CAICE), CHE-1305427 for supporting this work. M.A.J. thanks the Air Force Office of Scientific Research for the cryogenic spectrometer used in the gas phase experiments. K.D.J. thanks the Department of Energy under grant no. DE-FG02-00ER15066. C.J. Mundy and S.M. Kathmann are supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences & Biosciences. M.D. Baer was supported by the U.S. Department of Energy, Office of Basic Energy Sciences, Biomolecular Materials Program at PNNL. PNNL is operated by Battelle Memorial Institute for the U.S. Department of Energy under Contract No. DE-AC05- 76RL01830. Computing resources for the calculation of harmonic spectra were allocated by PNNL’s Institutional Computing program.

Denton, Joanna↗

Application of the BINS superheated drop detector spectrometer to the {sup 9}Be(p,xn) neutron energy spectrum determination

In the framework of TRASCO-BNCT project, a Bubble Interactive Neutron Spectrometer (BINS) device was applied to the characterization of the angle-and energy-differential neutron spectra generated by the {sup 9}Be(p,xn)reaction. The BINS spectrometer uses two superheated emulsion detectors, sequentially operated at different temperatures and thus provides a series of six sharp threshold responses, covering the 0.1-10 MeV neutron energy range. Spectrum unfolding of the data was performed by means of MAXED code. The obtained angle, energy-differential spectra were compared with those measured with a Bonner sphere spectrometer, a silicon telescope spectrometer and literature data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heterometal silver/copper(I) modulated thermochromism of two isostructural iodoplumbates

Two isostructrual heterometallic iodoplumbates [Y(DMF){sub 8}]{sub 2n}[Pb{sub 7}M{sub 2}I{sub 22}]{sub n} [M=Cu(1), Ag(2)] have been prepared. Chargely balanced by [Y(DMF){sub 8}]{sup 3+}, [Pb{sub 7}M{sub 2}I{sub 22}]{sub n}{sup 6n−} displays a 1D zigzag chain constructed from MI{sub 4} tetrahedron and Pb{sub 7}I{sub 24} unit similar to a fragment of commonly observed (PbI{sub 3}){sub n}{sup n−} chain. Their band gaps (Eg) can be estimated as 2.66 and 2.72 eV, revealing potential semiconducting properties. Interestingly, thermochromism exhibits different response to the temperature for two compounds, which is verified by the diffuse-reflectance UV–visible spectra and crystallographic data at different temperatures. Moreover, this phenomenon is attributed to the difference of heterometal Ag and Cu(I). - Graphical abstract: Two isostructrual heterometallic iodoplumbates [Y(DMF){sub 8}]{sub 2n}[Pb{sub 7}M{sub 2}I{sub 22}]{sub n} [M=Cu(1),Ag(2)] have been prepared. [Pb{sub 7}M{sub 2}I{sub 22}]{sub n}{sup 6n−} displays a 1D zigzag chain constructed from MI{sub 4} tetrahedron and Pb{sub 7}I{sub 24} unit similar to a fragment of commonly observed (PbI{sub 3}){sub n}{sup n−} chain. Interestingly, the thermochromism for two compounds exhibits different response to the temperature, which is attributed to the difference of heterometal Ag and Cu. - Highlights: • Two isostructrual heterometallic iodoplumbates have been prepared. • Single-crystal-X-ray diffraction data were collected at different temperatures. • Spectroscopic characterization showed semiconducting and thermochromic properties. • The difference of thermochromic properties for two compounds was studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cardiovascular regulation in humans in response to oscillatory lower body negative pressure

The frequency response characteristics of human cardiovascular regulation during hypotensive stress have not been determined. We therefore exposed 10 male volunteers to seven frequencies (0.004-0.1 Hz) of oscillatory lower body negative pressure (OLBNP; 0-50 mmHg). Fourier spectra of arterial pressure (AP), central venous pressure (CVP), stroke volume (SV), cardiac output (CO), heart rate (HR), and total peripheral resistance (TPR) were determined and first harmonic mean, amplitude, and phase angles with respect to OLBNP are presented. AP was relatively well regulated as demonstrated by small oscillations in half amplitude (3.5 mmHg) that were independent of OLBNP frequency and similar to unstressed control spectra. Due to the biomechanics of the system, the magnitudes of oscillations in calf circumference (CC) and CVP decreased with increasing frequency; therefore, we normalized responses by these indexes of the fluid volume shifted. The ratios of oscillations in AP to oscillations in CC increased by an order of magnitude, whereas oscillations in CVP to oscillations in CC and oscillations in AP to oscillations in CVP both tripled between 0.004 and 0.1 Hz. Therefore, even though the amount of fluid shifted by OLBNP decreased with increasing frequency, the magnitude of both CVP and AP oscillations per volume of fluid shifted increased (peaking at 0.08 Hz). The phase relationships between variables, particularly the increasing lags in SV and TPR, but not CVP, indicated that efferent responses with lags of 5-6 s could account for the observed responses. We conclude that, at frequencies below 0.02 Hz, the neural system of humans functioned optimally in regulating AP; OLBNP-induced decreases in SV (by as much as 50%) were counteracted by appropriate oscillations in HR and TPR responses. As OLBNP frequency increased, SV, TPR, and HR oscillations increasingly lagged the input and became less optimally timed for AP regulation.

NASA Discipline Cardiopulmonary↗

Effect of conjugation with biomolecules on photoluminescence and structural characteristics of CdSe/ZnS quantum dots

The photoluminescence and photoluminescence excitation spectra, the X-ray diffraction patterns, and the effect of conjugation with biomolecules upon these characteristics are studied for silanized CdSe/ZnS quantum dots. Along with the band of annihilating excitons in the quantum dots, the luminescence spectra exhibit emission associated with defects. It is established that the emission spectrum of defects involves at least two components. It is shown that the defects are located mainly at the small-sized quantum dots; the defects responsible for the long-wavelength component are located mainly at the quantum dots larger in size than the quantum dots, at which the defects responsible for the short-wavelength component are located. It is found that conjugation with biomolecules induces not only the blue shift of the excitonic band, but transformation of the emission spectra of defects and an increase in the contribution of defects to the luminescence spectrum as well. The changes observed in the emission spectrum of defects are attributed to the formation of certain emission centers. It is shown that, when conjugated with biomolecules, the quantum dots experience increasing compression strains. This effect is responsible for the blue shift of the luminescence band of the quantum dots.

36 MATERIALS SCIENCE↗

Fabrication and characterization of brookite-rich, visible light-active TiO2 films for water splitting

We report that mild oxidation of Ti foils in air results in brookite-rich titanium oxide (TiO2) films withsimilar spectral response to that of dye-sensitized TiO2. X-ray powder diffraction and Ramanspectroscopy show that the onset of brookite formation occurs at 500 8C, and the material ischaracterized by a strong absorption band in the visible spectral range. The first-principle calculationsshow that enhanced visible light absorption correlates with the presence of Ti interstitials. Photocurrentdensity measurements of water splitting reveal that the brookite-rich TiO2 exhibits the highestphotocatalytic performance among the different forms of TiO2 produced by oxidation of Ti foils. Withincreasing oxidation temperature transformation to the rutile phase accompanied by declining visiblerange photoactivity is observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The mass-metallicity and fundamental metallicity relations at z > 2 using very large telescope and Subaru near-infrared spectroscopy of zCOSMOS galaxies

In the local universe, there is good evidence that, at a given stellar mass M, the gas-phase metallicity Z is anti-correlated with the star formation rate (SFR) of the galaxies. It has also been claimed that the resulting Z(M, SFR) relation is invariant with redshift—the so-called 'fundamental metallicity relation' (FMR). Given a number of difficulties in determining metallicities, especially at higher redshifts, the form of the Z(M, SFR) relation and whether it is really independent of redshift is still very controversial. To explore this issue at z > 2, we used VLT-SINFONI and Subaru-MOIRCS near-infrared spectroscopy of 20 zCOSMOS-deep galaxies at 2.1 < z < 2.5 to measure the strengths of up to five emission lines: [O II] λ3727, Hβ, [O III] λ5007, Hα, and [N II] λ6584. This near-infrared spectroscopy enables us to derive O/H metallicities, and also SFRs from extinction corrected Hα measurements. We find that the mass-metallicity relation (MZR) of these star-forming galaxies at z ≈ 2.3 is lower than the local Sloan Digital Sky Survey (SDSS) MZR by a factor of three to five, a larger change than found by Erb et al. using [N II]/Hα-based metallicities from stacked spectra. We discuss how the different selections of the samples and metallicity calibrations used may be responsible for this discrepancy. The galaxies show direct evidence that the SFR is still a second parameter in the MZR at these redshifts. However, determining whether the Z(M, SFR) relation is invariant with epoch depends on the choice of extrapolation used from local samples, because z > 2 galaxies of a given mass have much higher SFRs than the local SDSS galaxies. We find that the zCOSMOS galaxies are consistent with a non-evolving FMR if we use the physically motivated formulation of the Z(M, SFR) relation from Lilly et al., but not if we use the empirical formulation of Mannucci et al.

79 ASTRONOMY AND ASTROPHYSICS↗