Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Spatially resolved ballistic electron spectroscopy of subsurface interfaces

Buried interfaces have traditionally been inaccessible to direct investigation by surface-sensitive techniques. A unique and novel electronic probe, which is sensitive to subsurface electronic structure, has been utilized to probe Schottky barrier interfaces. The method, ballistic electron emission microscopy (BEEM), is based on scanning tunnelling microscopy (STM) techniques. A theoretical treatment has been developed to describe the ballistic electron spectra obtained by BEEM and this treatment is applied to data obtained on the Au-Si Schottky barrier interface system. Excellent agreement between experiment and theory is obtained. In addition, the treatment predicts nanometer spatial resolution for interface imaging by BEEM.

Bell, L. D.↗

Computer image analysis of etched tracks from ionizing radiation

I proposed to continue a cooperative research project with Dr. David S. McKay concerning image analysis of tracks. Last summer we showed that we could measure track densities using the Oxford Instruments eXL computer and software that is attached to an ISI scanning electron microscope (SEM) located in building 31 at JSC. To reduce the dependence on JSC equipment, we proposed to transfer the SEM images to UHCL for analysis. Last summer we developed techniques to use digitized scanning electron micrographs and computer image analysis programs to measure track densities in lunar soil grains. Tracks were formed by highly ionizing solar energetic particles and cosmic rays during near surface exposure on the Moon. The track densities are related to the exposure conditions (depth and time). Distributions of the number of grains as a function of their track densities can reveal the modality of soil maturation. As part of a consortium effort to better understand the maturation of lunar soil and its relation to its infrared reflectance properties, we worked on lunar samples 67701,205 and 61221,134. These samples were etched for a shorter time (6 hours) than last summer's sample and this difference has presented problems for establishing the correct analysis conditions. We used computer counting and measurement of area to obtain preliminary track densities and a track density distribution that we could interpret for sample 67701,205. This sample is a submature soil consisting of approximately 85 percent mature soil mixed with approximately 15 percent immature, but not pristine, soil.

Blanford, George E.↗

Enhancing Ion Migration in Grain Boundaries of Hybrid Organic-Inorganic Perovskites by Chlorine

Ionicity plays an important role in determining material properties, as well as optoelectronic performance of organometallic trihalide perovskites (OTPs). Ion migration in OTP films has recently been under intensive investigation by various scanning probe microscopy (SPM) techniques. Controversial findings regarding the role of grain boundaries (GBs) associated with ion migration are often encountered, likely as a result of feedback errors and topographic effects common in to SPM. In this work, electron microscopy and spectroscopy (scanning transmission electron microscopy/electron energy loss spectroscopy) are combined with a novel, open-loop, band-excitation, (contact) Kelvin probe force microscopy (BE-KPFM and BE-cKPFM), in conjunction with ab initio molecular dynamics simulations to examine the ion behavior in the GBs of CH 3 NH 3 PbI 3 perovskite films. Furthermore, this combination of diverse techniques provides a deeper understanding of the differences between ion migration within GBs and interior grains in OTP films. Our work demonstrates that ion migration can be significantly enhanced by introducing additional mobile Cl - ions into GBs. The enhancement of ion migration may serve as the first step toward the development of high-performance electrically and optically tunable memristors and synaptic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The development of efficient coding for an electronic mail system

Techniques for efficiently representing scanned electronic documents were investigated. Major results include the definition and preliminary performance results of a Universal System for Efficient Electronic Mail (USEEM), offering a potential order of magnitude improvement over standard facsimile techniques for representing textual material.

Rice, R. F.↗

Synthesis, network structure and morphology of s-triazine-organosilane glassy hybrid materials

A series of five hybrid materials are synthesized by the reaction of cyanuric chloride (C{sub 3}N{sub 3}Cl{sub 3}) with different alkoxysilanes (R{sub x}Si(OC{sub 2}H{sub 5}){sub 4-x}, R=CH{sub 3}, C{sub 6}H{sub 5} and x=0, 1, 2) in ethanol using sol-gel technique. The resulting s-triazine-organosilane products were examined using spectroscopic (UV-visible, FT-IR), thermal (thermogravimetric analysis, TGA), powder X-ray diffraction (P-XRD), BET analysis and microscopic (scanning electron microscopy, SEM) techniques. These hybrid materials exhibit globular and two-dimensional morphological textures with varying degrees of crystalline microstructures. Depending on the functionality of the organosilane building blocks the obtained hybrid materials exhibit different material characteristics including their solid state, Vicat softening point (Vicat hardness), density and porosity. BET surface area measurements indicate that these materials possess small specific surface areas of 0.36-2.3 m{sup 2}/g with external surface area of approx0.02 m{sup 2}/g. The phenyl-containing hybrids exhibit pronounced hydrolytic stability compared to the methyl- and silica-based analogs. The DMSO and sulfolane solutions of the prepared hybrids are transparent to visible light whereas their cold-compressed discs are optically opaque. - Graphical abstract: Network structure of s-triazine-organosilane glassy hybrid materials.

36 MATERIALS SCIENCE↗

Physical vapor deposition synthesis of tungsten monocarbide (WC) thin films on different carbon substrates

The synthesis of tungsten monocarbide (WC) thin films has been performed by physical vapor deposition on various substrates including glassy carbon, carbon fiber sheet, carbon foam, and carbon cloth. The WC and W{sub 2}C phase contents of these films have been evaluated with bulk and surface analysis techniques such as x-ray diffraction, x-ray photoelectron spectroscopy, and scanning electron microscopy. These characterization techniques were also used to determine the effects of synthesis by nonreactive and reactive sputtering. The synthesis of WC particles supported on the carbon fiber substrate has also been accomplished using the temperature programmed reaction method. Overall, the results demonstrate that the phase purity of tungsten carbides can be controlled by the deposition environment and annealing temperatures.

36 MATERIALS SCIENCE↗

Plasma etching of superconducting Niobium tips for scanning tunneling microscopy

We have developed a reproducible technique for the fabrication of sharp superconducting Nb tips for scanning tunneling microscopy (STM) and scanning tunneling spectroscopy. Sections of Nb wire with 250 μm diameter are dry etched in an SF₆ plasma in a Reactive Ion Etcher. The gas pressure, etching time, and applied power are chosen to control the ratio of isotropic to anisotropic etch rates and produce the desired tip shape. The resulting tips are atomically sharp, with radii of less than 100 nm, mechanically stable, and superconducting. They generate good STM images and spectroscopy on single crystal samples of Au(111), Au(100), and Nb(100), as well as a doped topological insulator Bi₂Se₃ at temperatures ranging from 30 mK to 9 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First-Principles Simulation of Beam-Induced Processes Underlying Atomic Manipulation in Electron Microscopes

The development of experimental methods and apparatuses capable of promoting atomically precise material manipulations holds great promise for realizing the ultimate limit of feature miniaturization in materials and devices. The ability to modify materials atom by atom is anticipated to usher in new technologies in areas as diverse as separation science, medicine, and quantum information science. Historically, scanning probe-based techniques have been the most prominent approaches in this space. However, these methods are best suited for the manipulation of surface-exposed regions of materials, as the strong perturbations required for bond scission are delivered most effectively to atoms in the near-proximity to the scanning probe. In contrast, convergent electron beams with energies tuned slightly below the threshold for inducing irreversible knock-on damage have recently been employed (within scanning transmission electron microscopy) to promote atomic-scale bond rearrangements in various beam-stable solids. Currently, however, the efficiency and selectivity of beam-induced atomic manipulation processes with focused electron beams are such that long irradiation times are required to induce a desired atomic rearrangement. With a better understanding of the underlying physics dictating the outcome of a given irradiation event, methods can be devised to improve the efficiency of these techniques so that their promise can be fully realized through widespread adoption.To this end, this Account details our recent efforts to develop and apply tractable first-principles simulation approaches for studying the response of materials to electric beam-like external electric potentials applied in real space. We briefly review the concepts and capabilities in the area of atomically precise materials manipulation and review the early demonstrations of accomplishments in this area, focusing on studies using scanned convergent electron beam probes in particular. We expound upon the depth of the challenge and identify critical shortcomings of theoretical methods that have previously been employed in the simulation of beam-induced processes. We then describe the computational methods that we have generalized from the concepts and tools most commonly applied to the study of molecular photochemistry and how our adaptations of these methods can be employed to capture the relevant dynamical phenomena for beam-induced processes ranging from the initial electron scattering to the ensuing multistate reactions. Here, we contextualize these methods within the current state of the art in this area, which has historically focused primarily on the simulation of inelastic image formation in the electron microscope for the purpose of interpreting the results of quantitative electron microscopy experiments. We demonstrate that the spatial distribution of state-specific excitation rates due to the presence of an external (probe) electric charge is inhomogeneous, such that irradiation at particular locations in materials can favor specific electronic transitions (and disallow others). In addition to the potential for excited-state reaction pathways to be accessed through the initial inelastic scattering of the tightly focused electron beam from the targeted atoms, we also identify favorable conditions for the electronically nonadiabatic evolution of the highly vibrationally excited system to open complex multistate reaction pathways. Implications of the early results for understanding the mechanisms and potential routes to improved efficiency and selectivity in beam-induced reactions are discussed. We conclude with a summary of the current state of theory and modeling capabilities in this area and provide our perspective on future directions for theoretical and experimental developments that we view as crucial to advancing the use of convergent electron beams in mode-specific, atomically precise platforms for direct-write materials modifications.

36 MATERIALS SCIENCE↗

Microstructures and properties of rapidly solidified alloys

The microstructure and properties of rapidly solidified aluminum alloys were researched. The effects of powder and flake chemistry and morphology and alternative consolidation processing parameters are being conducted. Samples of the powders being utilized were obtained for comprehensive metallurgical characterization. Seven aluminum alloys in the form of thin foils were studied by a variety of techniques including optical metallography, scanning electron microscope, and transmission electron microscope. Details of the microstructural characteristics are presented along with a discussion of the solidification process. A better understanding of the microstructure of the rapidly solidified aluminum alloys prepared by a variety of techniques such as roller quenching, the vacuum atomized procedure, ultrasonically atomized in inert atmospheres, and atomized in flue gas was provided.

Shechtman, D.↗

Preface to Special Topic: Piezoresponse Force Microscopy

Almost two decades beyond the inception of piezoresponse force microscopy (PFM) and the seminal papers by G€uthner and Dransfeld1 and Gruverman et al., the technique has become the prevailing approach for nanoscale functional characterization of polar materials and has been extended to the probing of other electromechanical effects through the advent of electrochemical strain microscopy (ESM). This focus issue celebrates some of the recent advances in the field and offers a wider outlook of polar materials and their overall characterization. In this paper, we cover topics that include discussions of the properties of traditional ferroelectrics, such as lead zirconate titanate (PZT) and lithium niobate, relaxorferroelectrics, as well as more “exotic” ferroelectric oxides such as hafnia, ferroelectric biological matter, and multiferroic materials. Technique-oriented contributions include papers on the coupling of PFM with other characterization methods such as x-ray diffraction (XRD) and superconducting quantum interface device (SQUID), in addition to considerations on the open questions on the electromechanical response in biased scanning probe microscopy (SPM) techniques, including the effects of the laser spot placement on the readout cantilever displacement, the influence of the tip on the creation of the domain shapes, and the impact of ionic and electronic dynamics on the observed nanoscale hysteretic phenomena.

36 MATERIALS SCIENCE↗

Error analysis applied to several inversion techniques used for the retrieval of middle atmospheric constituents from limb-scanning MM-wave spectroscopic measurements

The formal retrieval error analysis of Rodgers (1990) allows the quantitative determination of such retrieval properties as measurement error sensitivity, resolution, and inversion bias. This technique was applied to five numerical inversion techniques and two nonlinear iterative techniques used for the retrieval of middle atmospheric constituent concentrations from limb-scanning millimeter-wave spectroscopic measurements. It is found that the iterative methods have better vertical resolution, but are slightly more sensitive to measurement error than constrained matrix methods. The iterative methods converge to the exact solution, whereas two of the matrix methods under consideration have an explicit constraint, the sensitivity of the solution to the a priori profile. Tradeoffs of these retrieval characteristics are presented.

Puliafito, E.↗

Nano-Scale Fission Product Phases in an Irradiated U-7Mo Alloy Nuclear Fuel

Irradiated nuclear fuel is a very difficult material to characterize. Due to the large radiation fields associated with these materials, they are hard to handle and typically have to be contained in large hot cells. Even the equipment used for performing characterization is housed in hot cells or shielded glove boxes. The result is not only a limitation in the techniques that can be employed for characterization, but also a limitation in the size of features that can be resolved The most standard characterization techniques include light optical metallography (WM), scanning electron microscopy (SEM), and electron probe microanalysis (EPMA). These techniques are applied to samples that are typically prepared using grinding and polishing approaches that will always generate some mechanical damage on the sample surface. As a result, when performing SEM analysis, for example, the analysis is limited by the quality of the sample surface that can be prepared. However, a new approach for characterizing irradiated nuclear fuel has recently been developed at the Idaho National Laboratory (INL) in Idaho Falls, Idaho. It allows for a dramatic improvement in the quality of characterization that can be performed when using an instrument like an SEM. This new approach uses a dual-beam scanning microscope, where one of the beams isa focused ion beam (FIB), which can be used to generate specimens of irradiated fuel (-10µm x 10µm) for microstructural characterization, and the other beam is the electron beam of an SEM. One significant benefit of this approach is that the specimen surface being characterized has received much less damage (and smearing) than is caused by the more traditional approaches, which enables the imaging of nanometer­ sized microstructural features in the SEM. The process details are for an irradiated low-enriched uranium (LEU) U-Mo alloy fuel Another type of irradiated fuel that has been characterized using this technique is a mixed oxide fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Annealing Temperature on Structure and Magnetic Properties of Zn{sub 0.94}Mg{sub 0.01}Mn{sub 0.05}O Nanoparticles

Structural and magnetic characteristics of Zn{sub 0.94}Mg{sub 0.01}Mn{sub 0.05}O (ZnMgMnO) nanoparticles synthesized by Sol-Gel preparation technique in a wide temperature range were reported. The influence of annealing temperature on the crystal structure of ZnMgMnO nanoparticles was figured out by X-ray diffraction technique (XRD). To optimize the annealing temperature and reveal the particle formation and size, Scanning Electron Microscope (SEM) imaging technique was performed. The required stoichiometry of the synthesized samples was obtained by an energy dispersive X-ray analysis technique (EDX). Quantum Design Vibrating Sample Magnetometer (QDVSM) tool was used for the magnetic characterizations of Zn{sub 0.94}Mg{sub 0.01}Mn{sub 0.05}O composition. Magnetization measurements as a function of magnetic field (M-H) were performed in the magnetic field up to 10 kOe. Temperature dependence of magnetization measurements (M-T) was taken between 10 and 320 K temperature ranges.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Structure and Magnetization of Polycrystalline La{sub 0.66}Ca{sub 0.33}MnO{sub 3} and La{sub 0.66}Ba{sub 0.33}MnO{sub 3} Films Prepared Using Sol-Gel Technique

The structure and static magnetization of polycrystalline La{sub 0.66}Ca{sub 0.33}MnO{sub 3} (LCMO) and La{sub 0.66}Ba{sub 0.33}MnO{sub 3} (LBMO) films grown on glass substrate using sol-gel technique have been investigated. X-ray diffraction (XRD) analysis revealed the average grain sizes of about 12 and 10 nm for granular LCMO and LBMO samples, respectively. The root mean square (RMS) surface roughness of about 100 nm has been obtained for both films by using scanning electron microscope (SEM) technique. The temperature dependences of the magnetization of LCMO and LBMO films registered in zero field cooling (ZFC) and field cooling (FC) regimes revealed a superparamagnetic state in both samples with remarkable distribution of blocking temperatures in a wide temperature interval, the average values of which have been estimated to be about 120 and 90 K for LCMO and LBMO, respectively. The average magnetic crystallite sizes obtained from the magnetizations studies coincide with the values revealed from the structural studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Implementation of Precursor and Neutral Loss Scans on a Miniature Ion Trap Mass Spectrometer and Performance Comparison to a Benchtop Linear Ion Trap

Implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 miniature rectilinear ion trap mass spectrometer is described, and performance is compared to that of a commercial Thermo linear trap quadropole (LTQ) linear ion trap. The ac frequency scan version of the technique at constant rf voltage is used here because it is operationally much simpler to implement. Remarkably, the Mini 12 shows up to two orders of magnitude higher sensitivity compared to that of the LTQ. Resolution on the LTQ is better than unit at scan speeds of ~ 400 Th/s, whereas peak widths on the Mini 12, on average, range from 0.5 to 2.0 Th full width at half maximum and depend heavily on the precursor ion Mathieu q parameter as well as the pump down time that precedes the mass scan. Both sensitivity and resolution are maximized under higher pressure conditions (short pump down time) on the Mini 12. The effective mass range of the product ion ejection waveform was found to be 5.8 Th on the Mini 12 in the precursor ion scan mode vs. that of 3.9 Th on the LTQ. In the neutral loss scan mode, the product ion selectivity was between 8 and 11 Th on the Mini 12 and between 7 and 8 Th on the LTQ. The effects of nonlinear resonance lines on the Mini 12 were also explored. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗