Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Frequency Dependence of Trapped Flux Sensitivity in SRF Cavities

In this letter, we present the frequency dependence of the vortex surface resistance of bulk niobium accelerating cavities as a function of different state-of-the-art surface treatments. Higher flux surface resistance per amount of trapped magnetic field—sensitivity—is observed for higher frequencies, in agreement with our theoretical model. Higher sensitivity is observed for N-doped cavities, which possess an intermediate value of the electron mean-free-path, compared to 120 °C and EP/BCP cavities. Experimental results from our study showed that the sensitivity has a non-monotonic trend as a function of the mean-free-path, including frequencies other than 1.3 GHz, and that the vortex response to the rf field can be tuned from the pinning regime to flux-flow regime by manipulating the frequency and/or the mean-free-path of the resonator, as reported in our previous studies. The frequency dependence of the trapped flux sensitivity to the amplitude of the accelerating gradient is also highlighted.

43 PARTICLE ACCELERATORS↗

Prediction of impact sensitivity, heat of formation and heat of explosion using atomic connectivity

In these proceedings we revisit a large collection of explosives and explosive descriptors with the goal of predicting impact sensitivity using only local atomic environments that can be deciphered from molecular SMILES strings as descriptors without utilizing empirically measured values or computationally expensive electronic structure calculations. From the original database of nearly 500 descriptors, removing empirically measured and electronic structure values decreased the number of descriptors to 135, which we reduced to 18 the most important descriptors using Random Forests. The condensed model predicted impact sensitivity with essentially the same accuracy as the existing, more complex model (R 2 = 0.788 and RSME = 0.312), while remaining applicable to all types of explosives (Peroxides, azides, C-Nitros, Nitroamines, Nitrate Esters, etc.). In addition to impact sensitivity, we proposed similar models to accurately predict values heat of formation (ΔH f ) and heat of explosion (Q), with R 2 = 0.966 and 0.916, respectively. In conclusion, the work in these proceedings allows for prediction of explosive performance and sensitivity with only chemical structure information and an estimate of density.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A robust high sensitivity scanning thermal probe for simultaneous microscale thermal and thermoelectric property mapping

Scanning Thermal Microscopy (SThM) provides efficient thermal property measurement with micro- or nanoscale spatial resolution. However, the sensitivity and accuracy of state-of-the-art thermal probes have been limited by excessive thermal contact resistance between the probe and sample. Introduced herein is a robust thermal microprobe that can increase the probe-sample contact force by more than two orders of magnitude, thereby reducing the probe-sample thermal contact resistance by as much as 96% and increasing measurement sensitivity by more than 240% compared to a commercial thermal probe with the same dimensions and measurement principle. The relationship between the probe-sample thermal contact resistance, thermal exchange radius, and sample thermal conductivity is determined experimentally. Simultaneous measurement of thermal conductivity and Seebeck coefficient with unprecedented sensitivity is demonstrated using the enhanced scanning thermal microprobe on samples of an extended range of thermal conductivity up to 18 W/m K, increasing the range of samples applicable to SThM when compared to the conventional commercial probe with diminished measurement sensitivity above ~10 W/m K. The probe is further demonstrated by simultaneously mapping thermal conductivity and Seebeck coefficient as a function of depth from the irradiated surface of an ion-irradiated bulk nanostructured thermoelectric material. In addition to enabling microscale thermal conductivity and Seebeck coefficient measurement of materials previously not applicable to SThM, the probe can also facilitate high-throughput characterization of combinatorial materials to aid the rapid discovery of compositions and processing conditions that yield highly desired thermal and thermoelectric properties.

36 MATERIALS SCIENCE↗

Electric field sensitivity of molecular color centers

Molecular color centers with S=1 ground states are promising candidates for quantum sensing of electric fields. These molecules have an electronic structure similar to solid state color centers, but they allow for processing modalities that permit direct interfacing with an analyte. Currently, it is unknown how sensitive these molecules are to electric fields and what molecular properties affect their sensitivity. We perform density functional theory calculations to understand the impact of electric fields on the electronic structure of five nominally tetrahedral molecular color centers exhibiting variable transition metal chemistry and ligand densities. We then extract the Stark parameters from each of these molecules and compare them to molecular properties such as the dipole moment and inner shell stiffness and find that the dipole moment of the molecule largely governs sensitivity. We predict that polar heteroleptic molecules may have electric field sensitivities comparable to solid state color centers such as nitrogen-vacancy centers in diamond.

Physics↗

New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the HIBEAM/NNBAR experiment at the European Spallation Source

The violation of baryon number, , is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the Universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR program is a proposed two-stage experiment at the European Spallation Source to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron–antineutron oscillation () via mixing, neutron–antineutron oscillation via regeneration from a sterile neutron state (), and neutron disappearance (n → n′); the effective process of neutron regeneration () is also possible. The program can be used to discover and characterize mixing in the neutron, antineutron and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis and the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-sensitivity operation of single-beam optically pumped magnetometer in a kHz frequency range

Here, optically pumped magnetometers (OPM) can be used in various applications, from magnetoencephalography to magnetic resonance imaging and nuclear quadrupole resonance (NQR). OPMs provide high sensitivity and have the significant advantage of non-cryogenic operation. To date, many magnetometers have been demonstrated with sensitivity close to 1 fT, but most devices are not commercialized. Most recently, QuSpin developed a model of OPM that is low cost, high sensitivity, and convenient for users, which operates in a single-beam configuration. Here we developed a theory of single-beam (or parallel two-beam) magnetometers and showed that it is possible to achieve good sensitivity beyond their usual frequency range by tuning the magnetic field. Experimentally we have tested and optimized a QuSpin OPM for operation in the frequency range from DC to 1.7 kHz, and found that the performance was only slightly inferior despite the expected decrease due to deviation from the spin-exchange relaxation-free regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing spin dressing sensitivity for the nEDMSF experiment

nEDMSF aims to measure the neutron electric dipole moment (d n ) with unprecedented precision. In this paper we explore the experiment's sensitivity when operating with an implementation of the critical dressing method in which the angle between the neutron and Helium-3 spins (ϕ 3n ) is subjected to a square modulation by an amount ϕ d (the “dressing angle”). Several parameters can be tuned to optimize sensitivity. We find roughly 10% improvement over a previous estimate, resulting primarily from the addition of a waiting period between the π/2 pulse that initiates d n -driven ϕ 3n growth and the start of ϕ3n modulation. We find negligible further improvement by allowing ϕ d to vary continuously over the course of a run, and no degradation resulting from the addition of an in situ background measurement into each ϕ3n modulation sequence. A complete simulation confirms a 300 live-day sensitivity ofσ = 1.45×10 -28 e ·cm. At this level of sensitivity, σ ϕ3n0 = 1 mrad precision on the initial n/ 3 He angle difference is not negligible.

47 OTHER INSTRUMENTATION↗

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators↗

Sensitivity Analysis of Genome-Scale Metabolic Flux Prediction

TRIMER, Transcription Regulation Integrated with MEtabolic Regulation, is a genome-scale modeling pipeline targeting at metabolic engineering applications. Using TRIMER, regulated metabolic reactions can be effectively predicted by integrative modeling of metabolic reactions with a Transcription Factor (TF)-gene regulatory network (TRN), which is modeled via a Bayesian network (BN). In this paper, we focus on sensitivity analysis of metabolic flux prediction for uncertainty quantification of BN structures for TRN modeling in TRIMER. We propose a computational strategy to construct the uncertainty class of TRN models based on the inferred regulatory order uncertainty given transcriptomic expression data. With that, we analyze the prediction sensitivity of the TRIMER pipeline for the metabolite yields of interest. The obtained sensitivity analyses can guide Optimal Experimental Design (OED) to help acquire new data that can enhance TRN modeling and achieve specific metabolic engineering objectives, including metabolite yield alterations. Here we have performed small- and large-scale simulated experiments, demonstrating the effectiveness of our developed sensitivity analysis strategy for BN structure learning to quantify the edge importance in terms of metabolic flux prediction uncertainty reduction and its potential to effectively guide OED.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity Analysis of Primary-Side LCC and Secondary-Side Series Compensated Wireless Charging System

This paper presents the sensitivity analysis of primary-side LCC tuned and secondary-side series tuned wireless charging system with experimental validation. The primary and secondary coils have been modeled as a loosely coupled transformer to obtain a circuit model which can be analyzed for parametric sensitivity. Furthermore, sensitivity to variation in coupling coefficient and load are presented. To prove the effectiveness of the theoretical analyses, a test setup was built and tested up to 10kW, demonstrating the operation of the primary-side LCC and secondary-side series wireless power transfer system. The circuit model derived using the loosely coupled transformer model is verified experimentally by using a frequency response analyzer. The experimental results confirmed that the sensitivity analysis can be accurately used for future system designs.

Galigekere, Veda Prakash↗

Analytical Voltage Sensitivity Analysis for Unbalanced Power Distribution System

Large scale integration of distributed energy resources and electric vehicles in a transactive energy environment present new challenges in terms of voltage stability and fluctuations in a power distribution system. The impact of different level of DER/EV penetration on the voltages across the network is typically quantified through voltage sensitivity analyses. Existing methods of voltage sensitivity analysis are computationally expensive and prior efforts to develop analytical approximation lacks generality and have not been effectively validated. The objective of this work is to provide a new analytical method of voltage sensitivity analysis that has low computational cost and also allows for stochastic analysis of voltage change. This paper first derives an analytical approximation of change in voltage at a particular bus due to change in power consumption at other bus in a radial three phase unbalanced power distribution system. Then, the proposed method is shown to be valid for different load configurations, which demonstrates its generality. The results from our analytical approach is validated via classical load flow simulation of the test system based on IEEE 37 bus network. The proposed method is shown to have good accuracy, and computation complexity is of order O(1), compared to O(n3) in classical sensitivity analysis approaches.

Munikoti, Sai↗

A Comparative Study of the Perceptual Sensitivity of Topological Visualizations to Feature Variations

Color maps are a commonly used visualization technique in which data are mapped to optical properties, e.g., color or opacity. Color maps, however, do not explicitly convey structures (e.g., positions and scale of features) within data. Topology-based visualizations reveal and explicitly communicate structures underlying data. Although our understanding of what types of features are captured by topological visualizations is good, our understanding of people's perception of those features is not. Further, this paper evaluates the sensitivity of topology-based isocontour, Reeb graph, and persistence diagram visualizations compared to a reference color map visualization for synthetically generated scalar fields on 2-manifold triangular meshes embedded in 3D. In particular, we built and ran a human-subject study that evaluated the perception of data features characterized by Gaussian signals and measured how effectively each visualization technique portrays variations of data features arising from the position and amplitude variation of a mixture of Gaussians. For positional feature variations, the results showed that only the Reeb graph visualization had high sensitivity. For amplitude feature variations, persistence diagrams and color maps demonstrated the highest sensitivity, whereas isocontours showed only weak sensitivity. These results take an important step toward understanding which topology-based tools are best for various data and task scenarios and their effectiveness in conveying topological variations as compared to conventional color mapping.

97 MATHEMATICS AND COMPUTING↗

Synthesis, Characterization, Photophysics and Photochemistry of Pyrylogen Electron Transfer Sensitizers

A series of new dicationic sensitizers that are hybrids of pyrylium salts and viologens has been synthesized. The electrochemical and photophysical properties of these "pyrylogen" sensitizers are reported in sufficient detail to allow rationale design of new photoinduced electron transfer reactions. The range of their reduction potentials (+0.37-+0.05V vs SCE) coupled with their range of singlet (48-63 kcal mol(-1)) and triplet (48-57kcalmol(-1)) energies demonstrate that they are potent oxidizing agents in both their singlet and triplet excited states, thermodynamically capable of oxidizing substrates with oxidation potentials as high as 3.1eV. The pyrylogens are synthesized in three steps from readily available starting materials in modest overall 11.4-22.3% yields. These sensitizers have the added advantages that: (1) their radical cations do not react on the CV timescale with oxygen bypassing the need to run reactions under nitrogen or argon and (2) have long wavelength absorptions between 413 and 523nm well out of the range where competitive absorbance by most substrates would cause a problem. These new sensitizers do react with water requiring special precautions to operate in a dry reaction environment.

Clennan, Edward L.↗

Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning

Treatment plans optimized for intensity modulated proton therapy (IMPT) may be very sensitive to setup errors and range uncertainties. If these errors are not accounted for during treatment planning, the dose distribution realized in the patient may by strongly degraded compared to the planned dose distribution. The authors implemented the probabilistic approach to incorporate uncertainties directly into the optimization of an intensity modulated treatment plan. Following this approach, the dose distribution depends on a set of random variables which parameterize the uncertainty, as does the objective function used to optimize the treatment plan. The authors optimize the expected value of the objective function. They investigate IMPT treatment planning regarding range uncertainties and setup errors. They demonstrate that incorporating these uncertainties into the optimization yields qualitatively different treatment plans compared to conventional plans which do not account for uncertainty. The sensitivity of an IMPT plan depends on the dose contributions of individual beam directions. Roughly speaking, steep dose gradients in beam direction make treatment plans sensitive to range errors. Steep lateral dose gradients make plans sensitive to setup errors. More robust treatment plans are obtained by redistributing dose among different beam directions. This can be achieved by the probabilistic approach. In contrast, the safety margin approach as widely applied in photon therapy fails in IMPT and is neither suitable for handling range variations nor setup errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-562: Scanned Percent Depth Dose Curve Discrepancy for Photon Beams with Physical Wedge in Place (Varian IX) Using Different Sensitive Volume Ion Chambers

Purpose: To investigate and report the discrepancy of scanned percent depth dose (PDD) for photon beams with physical wedge in place when using ion chambers with different sensitive volumes. Methods/Materials: PDD curves of open fields and physical wedged fields (15, 30, 45, and 60 degree wedge) were scanned for photon beams (6MV and 10MV, Varian iX) with field size of 5x5 and 10x10 cm using three common scanning chambers with different sensitive volumes - PTW30013 (0.6cm3), PTW23323 (0.1cm3) and Exradin A16 (0.007cm3). The scanning system software used was OmniPro version 6.2, and the scanning water tank was the Scanditronix Wellhoffer RFA 300.The PDD curves from the three chambers were compared. Results: Scanned PDD curves of the same energy beams for open fields were almost identical between three chambers, but the wedged fields showed non-trivial differences. The largest differences were observed between chamber PTW30013 and Exradin A16. The differences increased as physical wedge angle increased. The differences also increased with depth, and were more pronounced for 6MV beam. Similar patterns were shown for both 5x5 and 10x10 cm field sizes. For open fields, all PDD values agreed with each other within 1% at 10cm depth and within 1.62% at 20 cm depth. For wedged fields, the difference of PDD values between PTW30013 and A16 reached 4.09% at 10cm depth, and 5.97% at 20 cm depth for 6MV with 60 degree physical wedge. Conclusion: We observed a significant difference in scanned PDD curves of photon beams with physical wedge in place obtained when using different sensitive volume ion chambers. The PDD curves scanned with the smallest sensitive volume ion chamber showed significant difference from larger chamber results, beyond 10cm depth. We believe this to be caused by varying response to beam hardening by the wedges.

07 ISOTOPE AND RADIATION SOURCES↗

Poster - 24: Characterization of the energy dependence of high-sensitivity MCP-N TLD and Al2O3:C OSLD in-vivo dosimetry systems for 40–100 kVp energies

Purpose: To characterize the energy dependence of high-sensitivity MCP-N TLD and Al{sub 2}O{sub 3}:C OSLD dosimetry systems at low (40–100 kVp) energies for in-vivo dosimetry. Methods: We assessed the variation of response with energy of two detectors in the 40–100 kVp energy range: high-sensitivity MCP-N TLDs (LiF:Mg,Cu,P) and OSLDs (Al{sub 2}O{sub 3}:C). The detectors were irradiated with an XRad 320ix biological irradiator under reference conditions. The delivered dose was 10 cGy for 7 beam qualities ranging from 40–100 kVp, 1.7–4.0 mm Al, and effective energies 26.9–37.9 keV. Both sets of detectors were also irradiated under reference conditions at 6 MV using a Varian Clinac 21Ex to assess the change in response from high-energy beams. Results: The MCP-N high-sensitivity TLDs were relatively insensitive to energies in the kV range, as their response varied by ±5%, i.e. well within the reproducibility limits of these detectors. However, the OSLDs exhibited a linearly-decreasing response with energy with a response 18.7% higher at 40 kVp than at 100 kVp for the same nominal dose. Compared to the 6 MV beams used in conventional radiotherapy, OSLDs responded 3.3–3.9 times higher depending on beam quality while the MCP-N TLD response was unchanged within experimental uncertainty. Conclusions: Unlike the more commonly used TLD-100, the high-sensitivity MCP-N TLDs exhibit little to no energy response. OSLDs are shown to be highly energy-dependent, both from MV to kV and within the kV range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Freestanding VO 2 membranes on epidermal nanomesh for ultra-sensitive correlated breathable sensors

The interest in highly sensitive sensors is rapidly increasing for detecting very tiny signals for Internet of Things devices. Here, we achieve ultra-sensitive correlated breathable sensors based on freestanding VO 2 membranes. We fabricate the membranes by growing VO 2 films onto sacrificial Sr 3 Al 2 O 6 layer grown on SrTiO 3 , selectively dissolving the Sr 3 Al 2 O 6 in water, and then rendering freestanding VO 2 membrane on nanomesh. The nanomeshes are extremely flexible, sweat permeable, and readily skin-adhesive. The resistance of the VO 2 membranes is reversibly tuned by human’s tiny mechanical stimuli and breath stimuli. The stimuli modulate the Peierls dimerization of one-dimensional V-V chains in the VO 2 lattice which concomitantly controls the electron correlation and hence resistivity. Since our breathable sensors operate based on quantum-mechanical correlation effects, their sensitivity is 1-2 orders of magnitude higher than conventional tactile and respiratory sensors based on other materials. Thus, the freestanding membranes of correlated oxides on epidermal nanomeshes are multifunctional platforms for developing ultra-sensitive correlated breathable sensors.

36 MATERIALS SCIENCE↗